치과 임플랜트 지대나사의 풀림 현상에 관한 연구 (A STUDY ON THE ABUTMENT SCREW LOOSENINE OF DENTAL IMPLANTS)

  • 강윤모;임주환;조인호
    • 대한치과보철학회지
    • /
    • 제34권1호
    • /
    • pp.1-14
    • /
    • 1996
  • Abutment screw loosening of dental implant is a major problem in the treatment of dental implant. The purpose of this study was to examine the effect on the prevention of screw loosening according to tightening method and using of washer. In the first experiment, using a implant fixture and precisely fabricated temporary cylinder, the loosening torque was measured by tightening the screw 5 times repeatedly. In the second experiment, the fabricated crown and implant fixture was tightened by the screw that is attatched washer and then the loosening torque was measured after loading it 1800, 12600 times under the force of 150N. The results were as follows. 1. The highest loosening torque appeared after tightening 3 times repeatedly(p<0.01). 2. When the washer was used, the loosening torque was increased significantly under the loading 1800 times(p<0.01), 3. When the washer was used, the loosening torque was increaed under the loading 12600 times, but it is statistically not significant(p<0.01). The first experiment results mean that 3 times repeated tightening screw is most effective clinically. The second results mean that washer is effective in prevention screw loosening, but the effect is decreased with increasing load.

  • PDF

COMPARATIVE ACCURACY OF THE SPLINTED AND UNSPLINTED IMPRESSION METHODS FOR INTERNAL CONNECTION

  • Choi, Jung-Han;Kim, Chang-Whe;Jang, Kyung-Soo;Lim, Young-Jin
    • 대한치과보철학회지
    • /
    • 제43권3호
    • /
    • pp.352-362
    • /
    • 2005
  • Statement of problem. Accurate impression is essential to success of implant prostheses. But there have been few studies about the accuracy of fixture-level impression techniques in internal connection implant systems. Purpose. The purpose of this study was to compare the accuracy of two fixture-level impression techniques in two conditions (parallel and divergent) and to assess the effect of tightening sequences and forces on stresses generated on superstructures in internal connection implant system (Astra Tech). Material and methods. Two metal master frameworks made from two abutments (Cast-to Abutment ST) each and a corresponding, passively fitting, dental stone master cast with four fixture replicas (Fixture Replica ST) were fabricated. Ten dental stone casts for each impression techniques (direct unsplinted & splinted technique) were made with vinyl polysiloxane impressions from the master cast. Strain gauges for each framework were fixed midway between abutments to measure the degree of framework deformation on each stone cast. Pairs of strain gauges placed opposite each other constituted one channel (half Wheatstone bridge) to read deformation in four directions (superior, inferior, anterior, and posterior). Deformation data were analyzed using one-way ANOVA and the Tukey test at the .01 level of significance. And the effect of tightening sequences (right-to-left and left-to-right) and forces (10 Ncm and 20 Ncm) were assessed with ten stone casts made from parallel condition by the splinted technique. Deformation data were analyzed using paired t-test at the .01 level of significance. Conclusions. Within the limitations of this study, the following conclusions could be drawn. 1. Frameworks bent toward the inferior side on all casts made by both direct unsplinted and splinted impression techniques in both parallel and divergent conditions. 2. There was no statistically significant difference of accuracy between the direct unsplinted and splinted impression techniques in both parallel and divergent conditions (P>.01). 3. There was no statistically significant difference of stress according to screw tightening sequences in casts made by the splinted impression technique in parallel condition (P>.01). 4. Greater tightening force resulted in greater stress in casts made by the splinted impression technique in parallel condition (P<.01).

선박용 판형 열교환기의 볼트풀림방지 및 수량최소화기법 개발 (Development of a Technique to Prevent Bolt Looseness and to Decrease in Quantity for the Plate Type Heat Exchanger Used in Large Craft)

  • 김호윤;배원병;장영준;한승무;김철
    • 한국정밀공학회지
    • /
    • 제24권9호
    • /
    • pp.44-51
    • /
    • 2007
  • There are many methods to assemble various parts of a product, and one of them is the bolting system widely used in a industrial field due to the merits; easiness to obtain strong tightening force, simplicity of assemble or disassemble in order to repair, substitution or cleaning, and so on. But this bolting system needs attachments not to let a bolt loose and they are an important factor to cost a great deal. In this study, some equations are suggested and FE analyses are carried out to verify the cause of the bolt looseness occurring in the tightening process. And because the number of bolts in the bolting system has been decided by empirical know-how of designers in the field, safety rate in the plate type heat exchanger is often too high. Therefore the equations to decrease in quantity are suggested in consideration of the relationship between a critical shearing force acting on the screw and a normal force acting on the cooling plate by the working fluid.

Loosening torque of Universal Abutment screws after cyclic loading: influence of tightening technique and screw coating

  • Bacchi, Atais;Regalin, Alexandre;Bhering, Claudia Lopes Brilhante;Alessandretti, Rodrigo;Spazzin, Aloisio Oro
    • The Journal of Advanced Prosthodontics
    • /
    • 제7권5호
    • /
    • pp.375-379
    • /
    • 2015
  • PURPOSE. The purpose of this study was to evaluate the influence of tightening technique and the screw coating on the loosening torque of screws used for Universal Abutment fixation after cyclic loading. MATERIALS AND METHODS. Forty implants (Titamax Ti Cortical, HE, Neodent) (n=10) were submerged in acrylic resin and four tightening techniques for Universal Abutment fixation were evaluated: A - torque with 32 Ncm (control); B - torque with 32 Ncm holding the torque meter for 20 seconds; C - torque with 32 Ncm and retorque after 10 minutes; D - torque (32 Ncm) holding the torque meter for 20 seconds and retorque after 10 minutes as initially. Samples were divided into subgroups according to the screw used: conventional titanium screw or diamond like carbon-coated (DLC) screw. Metallic crowns were fabricated for each abutment. Samples were submitted to cyclic loading at $10^6$ cycles and 130 N of force. Data were analyzed by two-way ANOVA and Tukey's test (5%). RESULTS. The tightening technique did not show significant influence on the loosening torque of screws (P=.509). Conventional titanium screws showed significant higher loosening torque values than DLC (P=.000). CONCLUSION. The use of conventional titanium screw is more important than the tightening techniques employed in this study to provide long-term stability to Universal Abutment screws.

체결력 산포와 마찰계수의 감소를 위한 가진기의 진동량 변화 실험 (An Experimental Study of Vibrator Amplitude Change for a Clamping Force Dispersion and Friction Coefficient Decrease)

  • 이금강;문석만;조용주
    • Tribology and Lubricants
    • /
    • 제27권6호
    • /
    • pp.332-337
    • /
    • 2011
  • The object of this experimental study is to investigate influences of vibrator amplitude on clamping force in vibration for bolted joint. The experiment is that change the vibrator amplitude to check clamping force. also the friction coefficient calculated by equation to use an obtained in experiments. The main purpose of generation vibrations is decreasing the clamping force dispersion. also If vibration occurs while tightening the bolt is reduced coefficient of friction. In this paper, In experiments to measure the clamping force before vibrator's amplitude changing. Vibrator's amplitude changes to 5.5mm from 4.4mm. As a result, under various vibration condition, relationship of clamping force and Vibrator amplitude.

Experimental investigation of novel pre-tightened teeth connection technique for composite tube

  • Li, Fei;Zhao, Qilin;Chen, Haosen;Xu, Longxing
    • Steel and Composite Structures
    • /
    • 제23권2호
    • /
    • pp.161-172
    • /
    • 2017
  • A new composite tube connection method called the pre-tightened teeth connection technique is proposed to improve the composite tube connection efficiency. This paper first introduces the manufacturing process of the proposed technique. It then outlines how the mechanical properties of this technology were tested using four test groups. The factors that influence the load-bearing capacity and damage model of the connection were analyzed, and finally, the transfer load mechanism was investigated. The following conclusions can be obtained from the research results. (1) The new technique improves the compressive connection efficiency by a maximum of 79%, with the efficiency exceeding that of adhesive connections of the same thickness. (2) Changing the depth of teeth results in two types of damage: local compressive damage and shear damage. The bearing capacity can be improved by increasing the depth, length, and number of teeth as well as the pre-tightening force. (3) The capacity of the technique to transfer high loads is a result of both the relatively high interlaminar shear strength of the pultruded composite and the interlaminar shear strength increase provided by the pre-tightening force. The proposed technique shows favorable mechanical properties, and therefore, it can be extensively applied in the engineering field.

A Study on the Nylon Wire Holding and Release Mechanism for Cube Satellites by Applying Constant Holding

  • Koo, KeonWoo
    • 항공우주시스템공학회지
    • /
    • 제15권4호
    • /
    • pp.1-6
    • /
    • 2021
  • The non-explosive holding and release mechanism is used to prevent damage to the mission component caused by explosives when the deployment structure for Cube Satellites is separated. However, among the several types available, the non-explosive holding and release mechanism system using nylon wires depend on the nylon wire knot method and tightening power of the worker. Therefore, in this study, we conducted experiments with the operation of a new holding and release mechanism system by conceptualizing the Boa System Dial, which can provide a constant tightening force regardless of worker proficiency and deploying a imitational solar panel. In this study, the process of binding and unbinding with constant tension was recorded while applying the novel non-explosive holding and release mechanism using the Boa System Dial proposed. In addition, required advances are indicated for the application of the proposed system to actual Cube Satellites.

볼트 조임력에 의한 와이어로프의 휨 보강 (Flexural Strengthening with Wire Rope Using the Tightening Force of Bolts)

  • 김선영;송진규;이영욱;변항용
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제10권2호
    • /
    • pp.165-176
    • /
    • 2006
  • 본 연구는 볼트의 조임력을 이용한 와이어로프의 휨보강 효과에 대한 실험 및 사례에 대한 것이다. 본 공법은 와이어로프에 볼트와 너트를 이용해 긴장응력을 도입하며, 이 방법은 시공성이 매우 우수하다. 제안된 방법에 대한 휨보강 효과에 대한 검증을 위해 실험을 수행하였다. 콘크리트 압축강도는 24MPa이고 전단스팬비(a/d)가 2.8인 실험체의 주요변수로는 초기 긴장응력과 새들 수량으로 하였다. 실험결과, 무보강 실험체에 비해서 휨내력은 약 160% 증가하였으며, 초기 긴장력에 따라서 균열 및 극한모멘트가 증가하였다. 그러나 새들의 수량은 균열 및 극한모멘트에는 영향을 주지 않았다. 실제 구조물의 보강공사에 적용한 사례를 통해서 제안된 공법은 다른 보강방법보다 매우 경쟁력 있는 방법임을 알 수 있었다.

내구 열화에 따른 샤시계 볼트 체결력 변화 인자 연구 (A Study of Bolt Tightening Changing Factor according to Durability Degradation)

  • 최동영;최재칠;한종욱
    • 자동차안전학회지
    • /
    • 제7권1호
    • /
    • pp.20-26
    • /
    • 2015
  • In vehicle development process, durability test should be carried out in field condition. Nowadays there are many customer live there multiple conditions. It makes change of the car's material. Such change causes to lose a bolt. Diversifications of climatic conditions are also a matter of loosening the bolt. To avoid this problem, to identify the cause of the problem, and the solution should be applied. To avoid problems during the durability development test should be measured by the clamping force. Ultrasonic instruments clamping force without affecting the torque can be measured. This instrument is part of the problem by monitoring the clamping force required to obtain objective data.

정밀고속 PRESS 하사점 변위량에 영향을 최소화 하는 금형 EMBO 장치에 관한 구조 연구 (A structural study on mold EMBO equipment to minimize the influence on the bottom dead center displacement of precision high-speed press)

  • 김승수
    • Design & Manufacturing
    • /
    • 제10권3호
    • /
    • pp.46-50
    • /
    • 2016
  • Laminate products for motor core are developed with a structure in which the importance of quality level and clamping force is influenced by the recent performance and safety of the product. It has been confirmed that the accuracy of the mold is emphasized, and that the accuracy of the tightening force produced by the stacked product for the motor core is greatly influenced by the change in the bottom dead center displacement of the aged high speed press. The reason why setting the mold, and test the effect of bottom dead center of high speed press is to improve product pull force in embossing process at mold. We have applied the system to minimize the effect on the damping displacement under the dynamical degree of the equipment by applying the emboss complement device which can test the influence and complement in the process.