References
- Jemt T, Lekholm U, Grondahl K. 3-year followup study of early single implant restorations ad modum Branemark. Int J Periodontics Restorative Dent 1990;10:340-9.
- Jemt T, Laney WR, Harris D, Henry PJ, Krogh PH Jr, Polizzi G, Zarb GA, Herrmann I. Osseointegrated implants for single tooth replacement: a 1-year report from a multicenter prospective study. Int J Oral Maxillofac Implants 1991;6:29-36.
- Michalakis KX, Hirayama H, Garefis PD. Cement-retained versus screw-retained implant restorations: a critical review. Int J Oral Maxillofac Implants 2003;18:719-28.
- Torrado E, Ercoli C, Al Mardini M, Graser GN, Tallents RH, Cordaro L. A comparison of the porcelain fracture resistance of screw-retained and cement-retained implant-supported metal-ceramic crowns. J Prosthet Dent 2004;91:532-7. https://doi.org/10.1016/j.prosdent.2004.03.014
- Binon PP. Evaluation of the effectiveness of a technique to prevent screw loosening. J Prosthet Dent 1998;79:430-2. https://doi.org/10.1016/S0022-3913(98)70157-X
- Weiss EI, Kozak D, Gross MD. Effect of repeated closures on opening torque values in seven abutment-implant systems. J Prosthet Dent 2000;84:194-9. https://doi.org/10.1067/mpr.2000.108069
- Siamos G, Winkler S, Boberick KG. Relationship between implant preload and screw loosening on implant-supported prostheses. J Oral Implantol 2002;28:67-73. https://doi.org/10.1563/1548-1336(2002)028<0067:TRBIPA>2.3.CO;2
- Spazzin AO, Henrique GE, Nobilo MA, Consani RL, Correr-Sobrinho L, Mesquita MF. Effect of retorque on loosening torque of prosthetic screws under two levels of fit of implant-supported dentures. Braz Dent J 2010;21:12-7. https://doi.org/10.1590/S0103-64402010000100002
- Kim SK, Lee JB, Koak JY, Heo SJ, Lee KR, Cho LR, Lee SS. An abutment screw loosening study of a Diamond Like Carbon-coated CP titanium implant. J Oral Rehabil 2005;32: 346-50. https://doi.org/10.1111/j.1365-2842.2004.01475.x
- Bhering CL, Takahashi JM, Luthi LF, Henriques GE, Consani RL, Mesquita MF. Influence of the casting technique and dynamic loading on screw detorque and misfit of single unit implant-supported prostheses. Acta Odontol Scand 2013;71:404-9. https://doi.org/10.3109/00016357.2012.690528
- Farina AP, Spazzin AO, Consani RL, Mesquita MF. Screw joint stability after the application of retorque in implantsupported dentures under simulated masticatory conditions. J Prosthet Dent 2014;111:499-504. https://doi.org/10.1016/j.prosdent.2013.07.024
- Bulaqi HA, Mousavi Mashhadi M, Safari H, Samandari MM, Geramipanah F. Dynamic nature of abutment screw retightening: finite element study of the effect of retightening on the settling effect. J Prosthet Dent 2015;113:412-9. https://doi.org/10.1016/j.prosdent.2014.09.017
- Bulaqi HA, Mousavi Mashhadi M, Geramipanah F, Safari H, Paknejad M. Effect of the coefficient of friction and tightening speed on the preload induced at the dental implant complex with the finite element method. J Prosthet Dent 2015; 113:405-11. https://doi.org/10.1016/j.prosdent.2014.09.021
- Monties JR, Dion I, Havlik P, Rouais F, Trinkl J, Baquey C. Cora rotary pump for implantable left ventricular assist device: biomaterial aspects. Artif Organs 1997;21:730-4. https://doi.org/10.1111/j.1525-1594.1997.tb03731.x
- Tang L, Tsai C, Gerberich WW, Kruckeberg L, Kania DR. Biocompatibility of chemical-vapour-deposited diamond. Biomaterials 1995;16:483-8. https://doi.org/10.1016/0142-9612(95)98822-V
- Park JK, Choi JU, Jeon YC, Choi KS, Jeong CM. Effects of abutment screw coating on implant preload. J Prosthodont 2010;19:458-64. https://doi.org/10.1111/j.1532-849X.2010.00595.x
- Basilio Mde A, Butignon LE, Arioli Filho J. Effectiveness of screw surface coating on the stability of zirconia abutments after cyclic loading. Int J Oral Maxillofac Implants 2012;27: 1061-7.
- Cantwell A, Hobkirk JA. Preload loss in gold prosthesis-retaining screws as a function of time. Int J Oral Maxillofac Implants 2004;19:124-32.
- Jaarda MJ, Razzoog ME, Gratton DG. Providing optimum torque to implant prostheses: a pilot study. Implant Dent 1993;2:50-2. https://doi.org/10.1097/00008505-199304000-00010
- Dixon DL, Breeding LC, Sadler JP, McKay ML. Comparison of screw loosening, rotation, and deflection among three implant designs. J Prosthet Dent 1995;74:270-8. https://doi.org/10.1016/S0022-3913(05)80134-9
- Hagiwara M, Chashi N. New tightening technique for threaded fasteners. Materials and Engineering Proceedings of the International Offshore mechanics and Artic Engineering Symposium. New York; American Society of Mechanical Engineers 1992, p. 371-6.
- Jaarda MJ, Razzoog ME, Gratton DG. Geometric comparison of five interchangeable implant prosthetic retaining screws. J Prosthet Dent 1995;74:373-9. https://doi.org/10.1016/S0022-3913(05)80377-4
- Jaarda MJ, Razzoog ME, Gratton DG. Effect of preload torque on the ultimate tensile strength of implant prosthetic retaining screws. Implant Dent 1994;3:17-21. https://doi.org/10.1097/00008505-199404000-00002
Cited by
- Stability of the prosthetic screws of three types of craniofacial prostheses retention systems vol.42, pp.6, 2016, https://doi.org/10.5125/jkaoms.2016.42.6.352
- Influence of Screw Surface Treatment on Retention of Implant-Supported Fixed Partial Dentures vol.43, pp.4, 2017, https://doi.org/10.1563/aaid-joi-D-16-00145
- Effect of Coated Surfaces influencing Screw Loosening in Implants: A Systematic Review and Meta-analysis vol.8, pp.6, 2015, https://doi.org/10.5005/jp-journals-10015-1493
- A Comparison of Torque Stress on Abutment Screw of External Hexagon and Morse Taper Implant vol.19, pp.11, 2018, https://doi.org/10.5005/jp-journals-10024-2423
- Morse taper implant macrodesign, loading protocol and site of installation - retrospective study of 5,601 implants vol.48, pp.None, 2015, https://doi.org/10.1590/1807-2577.06919
- A Completely Cast-Free, Digital Workflow for Fabricating an Implant-Supported Prosthesis with a New Coded Healing Abutment vol.23, pp.1, 2015, https://doi.org/10.32542/implantology.2019003
- Abutment screw loosening in implants: A literature review vol.9, pp.11, 2020, https://doi.org/10.4103/jfmpc.jfmpc_1343_20
- Can ceramic veneer spark erosion and mechanical cycling affect the accuracy of milled complete-arch frameworks supported by 6 implants? vol.126, pp.6, 2015, https://doi.org/10.1016/j.prosdent.2020.05.038