• Title/Summary/Keyword: TiO

Search Result 9,056, Processing Time 0.035 seconds

Mineral chemistry and texture of the zoned amphiboles of the amphibolites in the Hwanggangri area, the northeastern region of Ogcheon metamorphic belt, Korea (옥천변성대 북동부 황강리 지역내 앰피볼라이트에 나타나는 대상 각섬석의 광물화학 및 조직)

  • 유영복;권용완;김형식
    • The Journal of the Petrological Society of Korea
    • /
    • v.9 no.2
    • /
    • pp.99-118
    • /
    • 2000
  • The variation of Na(A), K, Na(M4), A l O and Al(VI)+Fe3++Ti+Cr in the zonal amphiboles from the amphibolites of the Hwanggangri area indicates that the tschermakite-, edenite- and glaucophane substitutions are higher in the rim than in the core, in which actinolite changes to hornblende with going outward from core to rim. The contents of substitutional elements of hornblende~ of three samples@l29-2, M76-2, M78), which include diopside and greenish brown hornblende and are thought to represent the highest metamorphic grade, are lower than those of rim homblendes of the lower metamorphic grade and are higher than those of core actinolite that they conform to the middle domain in those of the whole amphiboles. Considerations about the origin of zonal amphiboles are as follows. Firstly, two samples(R102-1, R210-9) have the same amphibole composition like core is actinolitic hornblende, and rim is magnesian hastingsite although plagioclases such as albite(R102-1) and labradorite (R210-9) show the wide compositional difference. It is impossible to produce both albite and labradorite by one metamorphic event. Judging from this wide compositional difference, the existence of zonal amphiboles does not indicate the miscibility gap but is thought to be the result of the polymetamorphism. Secondly, the crystallographically sharp and gradational interfaces between actinolite and hornblende fonned in the amphibolites rgardless of the distance from the granite. In case of the samples(R210-9, M128, M130) having the sharp interface between two amphiboles, the plagioclase show the compositions produced at the low grade and the medium grade. Because such variable compositions of plagioclase indicates the overprinting of metamorphism of higher metamorphic grade than that of the formation of miscibility gap, it implies that zonal amphiboles were formed by polymetarnorphism. In case of the gradational interface between two amphiboles, this texture is also thought to be the effect of polymetamorphism from the fact that this texture mainly occur near the granite and from the consideration of the metamporphic grade. The relationship between the compositional variations of the amphiboles and the pressure types of metamorphism suggests that actinolitic core is considered to be grown by the metamorphism of medium pressure, while hornblende rim is shown to have genetic relations with the metamorphism of low pressure type.

  • PDF

Quantitative Elemental Analysis in Soils by using Laser Induced Breakdown Spectroscopy(LIBS) (레이저유도붕괴분광법을 활용한 토양의 정량분석)

  • Zhang, Yong-Seon;Lee, Gye-Jun;Lee, Jeong-Tae;Hwang, Seon-Woong;Jin, Yong-Ik;Park, Chan-Won;Moon, Yong-Hee
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.42 no.5
    • /
    • pp.399-407
    • /
    • 2009
  • Laser induced breakdown spectroscopy(LIBS) is an simple analysis method for directly quantifying many kinds of soil micro-elements on site using a small size of laser without pre-treatment at any property of materials(solid, liquid and gas). The purpose of this study were to find an optimum condition of the LIBS measurement including wavelengths for quantifying soil elements, to relate spectral properties to the concentration of soil elements using LIBS as a simultaneous un-breakdown quantitative analysis technology, which can be applied for the safety assessment of agricultural products and precision agriculture, and to compare the results with a standardized chemical analysis method. Soil samples classified as fine-silty, mixed, thermic Typic Hapludalf(Memphis series) from grassland and uplands in Tennessee, USA were collected, crushed, and prepared for further analysis or LIBS measurement. The samples were measured using LIBS ranged from 200 to 600 nm(0.03 nm interval) with a Nd:YAG laser at 532 nm, with a beam energy of 25 mJ per pulse, a pulse width of 5 ns, and a repetition rate of 10 Hz. The optimum wavelength(${\lambda}nm$) of LIBS for estimating soil and plant elements were 308.2 nm for Al, 428.3 nm for Ca, 247.8 nm for T-C, 438.3 nm for Fe, 766.5 nm for K, 85.2 nm for Mg, 330.2 nm for Na, 213.6 nm for P, 180.7 nm for S, 288.2 nm for Si, and 351.9 nm for Ti, respectively. Coefficients of determination($r^2$) of calibration curve using standard reference soil samples for each element from LIBS measurement were ranged from 0.863 to 0.977. In comparison with ICP-AES(Inductively coupled plasma atomic emission spectroscopy) measurement, measurement error in terms of relative standard error were calculated. Silicon dioxide(SiO2) concentration estimated from two methods showed good agreement with -3.5% of relative standard error. The relative standard errors for the other elements were high. It implies that the prediction accuracy is low which might be caused by matrix effect such as particle size and constituent of soils. It is necessary to enhance the measurement and prediction accuracy of LIBS by improving pretreatment process, standard reference soil samples, and measurement method for a reliable quantification method.

The Feasibility Study of photoconductor materials for the use of a dosimeter in Radiotherapy (광도전체 물질의 치료 방사선 선량계 적용을 위한 가능성 연구)

  • Jang, Giwon;Shin, Jungwook;Oh, Kyungmin;Park, Sungkwang;Kim, Jinyoung;Park, Jikoon;Nam, Sanghee
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.1
    • /
    • pp.81-84
    • /
    • 2013
  • The use of the dosimetry have been increasingly recognized as high radiation energy and radiation treatment planning(RTP) have rapidly developed in radiotherapy. There are many types of detectors for the dosimetry such as ionization chamber, film, TLD, diode, and etc. Among such detectors, the diode detector uses a photoconductor materials that generate electrical signals by the incident radiation energy. Though many research groups are recently interested in such materials, there is few experimental results except for silicon in the radiation therapy field. In this study, the feasibility of photoconductor materials was verified as a dosimeter through the evaluation of response properties at a high radiation energy. For the fabricated detectors based on $HgI_2$ and $PbI_2$, reproducibility, linearity, and pulse-rate response were analyzed. Such evaluations are essential factors for the use of dosimeter. From results, linearity and reproducibility of the fabricated $HgI_2$ detector indicated about 7% error. The fabricated $PbI_2$ detector showed 1.7% error in linearity, and 12.2% error in reproducibility.

Impedance Spectroscopy Models for X5R Multilayer Ceramic Capacitors

  • Lee, Jong-Sook;Shin, Eui-Chol;Shin, Dong-Kyu;Kim, Yong;Ahn, Pyung-An;Seo, Hyun-Ho;Jo, Jung-Mo;Kim, Jee-Hoon;Kim, Gye-Rok;Kim, Young-Hun;Park, Ji-Young;Kim, Chang-Hoon;Hong, Jeong-Oh;Hur, Kang-Heon
    • Journal of the Korean Ceramic Society
    • /
    • v.49 no.5
    • /
    • pp.475-483
    • /
    • 2012
  • High capacitance X5R MLCCs based on $BaTiO_3$ ceramic dielectric layers exhibit a single broad, asymmetric arc shape impedance and modulus response over the wide frequency range between 1 MHz to 0.01 Hz. Analysis according to the conventional brick-layer model for polycrystalline conductors employing a series connection of multiple RC parallel circuits leads to parameters associated with large errors and of little physical significance. A new parametric impedance model is shown to satisfactorily describe the experimental spectra, which is a parallel network of one resistor R representing the DC conductivity thermally activated by 1.32 eV, one ideal capacitor C exactly representing bulk capacitance, and a constant phase element (CPE) Q with complex capacitance $A(i{\omega})^{{\alpha}-1}$ with ${\alpha}$ close to 2/3 and A thermally activated by 0.45 eV or ca. 1/3 of activation energy of DC conductivity. The feature strongly indicate the CK1 model by J. R. Macdonald, where the CPE with 2/3 power-law exponent represents the polarization effects originating from mobile charge carriers. The CPE term is suggested to be directly related to the trapping of the electronic charge carriers and indirectly related to the ionic defects responsible for the insulation resistance degradation.

An 1 year prospective comparative study evaluating the effect of microthread on the maintenance of marginal bone level (임프란트 미세나사선이 주위골 수준변화에 미치는 영향에 대한 1년간의 전향적 비교 연구)

  • Shin, Dong-Hwan;Cho, Kyoo-Sung;Park, Kwang-Ho;Moon, Ik-Sang
    • Journal of Periodontal and Implant Science
    • /
    • v.33 no.3
    • /
    • pp.349-358
    • /
    • 2003
  • The success of dental implant therapy relies mainly upon the presence and maintenance of bone adjacent to implant. An 1-year prospective study was performed, upon the patients who were diagnosed as having chronic adult periodontitis, and had been treated with dental implant. The purpose of this study was to measure the radiographic bone level changes proximal to Astra Tech Single Tooth Implants (ATST, Astra Tech AB, $M{\"{o}}lndal$, Sweden) with microthread and Astra Tech TiOblast Implant (ATTB) without microthread supporting fixed partial prosthesis. Measurements were used to determine mean marginal bone loss during the first year of loading, 17 subjects with its partial prosthesis supported by 37 implants were followed up for an 1-year period. The marginal bone loss of implants was positively correlated with the retention factor, microthread($Microthread^{TM}$) in crestal area of ATST. The results were as follows. 1. The mean marginal bone loss of ATST was 0.226${\pm}$0.395mm, while ATTB was 0.440${\pm}$0.360mm. There was a statistically significant difference between ATST and ATTB (p<0.05). 2. The mean bone loss of the upper jaw fixtures was 0.269${\pm}$0.265mm for ATST and 0.529${\pm}$0.417mm for ATTB . There was a statistically significant difference between ATST and ATTB (p<0.05). In the lower jaw the corresponding figures were 0.167${\pm}$0.231mm and 0.313${\pm}$0.214mm, respectively. There was no significant difference between ATST and ATTB (p>0.05). 3. The mean bone loss of ATST was lower than that of ATTB at all sites according to bone quality. There was a statistically significant difference between ATST and ATTB at bone quality type III(p <0.05). In conclusion, the mean bone loss of ATST was smaller than that of ATTB . Therefore, the retention factor of crestal area, microthread ($Microthread^{TM}$) was effective to maintenance of marginal bone level around fixture.

Synthesis and Characterization of The Electrolessly Deposited Co(Re,P) Film for Cu Capping Layer (무전해 도금법으로 제조된 Co(Re,P) capping layer제조 및 특성 평가)

  • Han, Won-Kyu;Kim, So-Jin;Ju, Jeong-Woon;Cho, Jin-Ki;Kim, Jae-Hong;Yeom, Seung-Jin;Kwak, Noh-Jung;Kim, Jin-Woong;Kang, Sung-Goon
    • Korean Journal of Materials Research
    • /
    • v.19 no.2
    • /
    • pp.61-67
    • /
    • 2009
  • Electrolessly deposited Co (Re,P) was investigated as a possible capping layer for Cu wires. 50 nm Co (Re,P) films were deposited on Cu/Ti-coated silicon wafers which acted as a catalytic seed and an adhesion layer, respectively. To obtain the optimized bath composition, electroless deposition was studied through an electrochemical approach via a linear sweep voltammetry analysis. The results of using this method showed that the best deposition conditions were a $CoSO_4$ concentration of 0.082 mol/l, a solution pH of 9, a $KReO_4$ concentration of 0.0003 mol/l and sodium hypophosphite concentration of 0.1 mol/L at $80^{\circ}C$. The thermal stability of the Co (Re,P) layer as a barrier preventing Cu was evaluated using Auger electron spectroscopy and a Scanning calorimeter. The measurement results showed that Re impurities stabilized the h.c.p. phase up to $550^{\circ}C$ and that the Co (Re,P) film efficiently blocked Cu diffusion under an annealing temperature of $400^{\circ}C$ for 1hr. The good barrier properties that were observed can be explained by the nano-sized grains along with the blocking effect of the impurities at the fast diffusion path of the grain boundaries. The transformation temperature from the amorphous to crystal structure is increased by doping the Re.

Dry etch of Ta thin film on MTJ stack in inductively coupled plasma (ICP를 이용한 MTJ stack 위의 Ta 박막의 식각 특성 연구)

  • Kim, Dong-Pyo;Woo, Jong-Chang;Kim, Chang-Il
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.29-29
    • /
    • 2009
  • 현재 고집적 비휘발성 메모리 소자로는 MRAM (Magnetic Random Access Memory)과 PRAM (Phase Magnetic Random Access Memory)이 활발하게 미국과 일본, 한국 등에서 다양한 연구가 진행되어 오고 있다. 이 중에서 MRAM은 DRAM과 비슷한 10 ns의 빠른 읽기/쓰기 속도와 비휘발성 특성을 가지고 있으며, 전하를 저장할 커패시터가 필요 없고, 두 개의 자성충에 약 10 mA 정도의 전류를 가하면 그때 발생하는 약 10 Oe의 자장을 개개의 비트를 write하고, read 시에는 각 비트의 자기저항을 측정함으로써 데이터를 저장하고 읽을 있으므로, 고집적화가 가능성하다 [1]. 현재 우수한 박막 재료가 개발 되었으나, 고집적 MRAM 소자의 양산에는 해결 하여야 하는 문제점이 있다. 특히 다층 박막으로 구성되어 있으므로 식각 공정의 개발이 필수적이다. 지금까지 MRAM 재료의 식각은 주로 Ion milling, ICP, ECR등의 플라즈마 장치를 되었고, 식각 가스로는 할로겐 기체와 금속카보닐 형성을 위한 Co/$NH_3$$Ch_3OH$ 기체가 이용되고 있다. 그러나 할로겐 계열의 기체를 사용할 경우, 식각 부산물들의 높은 끓는점 때문에 식각 부산물이 박막의 표면에서 열적 탈착에 의하여 제거되지 않기 때문에 높은 에너지를 가지는 이온의 도움에 의한 식각이 필요하다. 또한 Cl 계열의 기체를 사용할 경우, 식각 공정 후, 시료가 대기에 노출되면 대기 중의 수분과 식각 부산물이 결합하여 부식 현상이 발생하게 된다. 그러므로 이를 방지하기 위한 추가 공정이 요구된다. 최근에는 부식 현상이 없고, MTJ 상부에 사용되는 Ta 또는 Ti Hard mask와의 높은 선택비를 가지는 $CH_3OH$ 또는 CO/$NH_3$가 사용되고 있다. 하부 박막에 따른 식각 특성에 연구와 다층의 박막의 식각 공정에 발생에 관한 발표는 거의 없다. MRAM을 양산에 적용하기 위하여서는 Main etch 공정에서 빠른 식각 공정이 필요하고, Over etch 공정에서 하부박막에 대한 높은 선택비가 요구된다. 그러므로 본 논문에서는 식각 변수에 따른 플라즈마 측정과 표면 반응을 비교하여 각 공정의 식각 메커니즘을 규명하고, Main Etch 공정에서는 $Cl_2$/Ar 또는 $BCl_3$/Ar 가스를 이용하여 식각 실험을 수행하고, Over etch 공정에는 낮은 Ta 박막 식각 속도를 가지는 $Ch_4/O_2$/Ar 또는 $Ch_3OH$/Ar 가스를 이용하고자 한다. 플라즈마 내의 식각종과 Ta 박막과의 반응을 XPS와 AES를 이용하여 분석하고, 식각 공정 변수에 따른 식각 속도, 식각 선택비와 식각 프로파일 변화를 SEM을 이용하여 관찰한다.

  • PDF

A Study on Surface Characteristics and Stability of Implants Treated with Anodic Oxidation and Fluoride Incorporation (양극 산화와 불소 화합물로 처리한 임플랜트의 표면 특성 및 골유착 안정성에 관한 연구)

  • Lim, Jae-Bin;Cho, In-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.22 no.4
    • /
    • pp.349-365
    • /
    • 2006
  • State of problem : A number of investigation about increase of surface area via various surface treatments and modification of surface constituent have been carried out. Purpose : The surface characteristics and stability of implants treated with anodic oxidation, fluoride ion incorporation, and groups treated with both methods were evaluated. Material and method : Specimens were divided into six groups, group 1 was the control group with machined surface implants, groups 2 and 3 were anodic oxidized implants (group 2 was treated with 1M $H_2SO_4$ and 185V, group 3 was treated with 0.25M $H_2SO_4$ and $H_3PO_4$ and 300V). Groups 4, 5 and 6 were treated with fluoride. Group 4 was machined implants treated with 0.1% HF, and groups 5 and 6 were groups 2 and 3 treated with 10% NaF respectively. Using variable methods, implant surface characteristics were observed, and the implant stability was evaluated on rabbit tibia at 0, 4, 8 and 12 weeks. Result : 1. In comparison of the surface characteristics of anodic oxidized groups, group 2 displayed delicate and uniform oxidation layer with small pore size containing Ti, C, O and showed mainly rutile, but group 3 displayed large pore size and irregular oxidation layer with many crators. 2. In comparison of the surface characteristics of fluoride treated groups 4, 5, 6 and non-fluoride treated groups 1, 2, 3, the configurations were similar but the fluoride treated groups displayed rougher surfaces and composition analysis revealed fluoride in groups 4, 5, 6. 3. The fluoride incorporated anodic oxidized groups showed the highest resonance frequency values and removal torque values, and the values decreased in the order of anodic oxidized groups, fluoride treated group, control group. 4. According to implant stability tests, group 2 and 3 showed significantly higher values than the control group (P<.05). The fluoride treated groups showed relatively higher values than the non fluoride treated groups and there were significant difference between group 4 and group 1 (P<.05). Conclusion : From the results above, it can be considered that the anodic oxidation method is an effective method to increase initial bone stability and osseointegration and fluoride containing implant surfaces enhance new bone formation. Implants containing both of these methods should increase osseointegration, and reduce the healing period.

A Numerical Analysis of the Pressure Drop according to the Shape of TiO2 Photocatalyst-coated Module in a HVAC Duct (HVAC 덕트 내에 설치된 광촉매코팅 모듈의 형상이 압력강하에 미치는 영향)

  • Hwang, Kwang-Il;Koo, Jae-Hyoek;Kim, Da-Hye;Lee, Hyun-In;Choi, Young-Guk
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.8
    • /
    • pp.1055-1062
    • /
    • 2011
  • The purpose of this study is to develop the shape of photocatalyst-coated module for improve the IAQ, which is installed at inside of ductwork and detachable. Including 3 column types(square, circle, diamond) and 2 fin types(diamond and square), totally 5 types are previously declared for numerical analysis and comparison, 5 types are. As the results of numerical analysis, almost the velocity varied at the range of ${\pm}0.3m$ from the module, except the Type A-3(diamond column type) which is affected to ${\pm}0.4m$ range and shows the biggest velocity differences. Among the 5 types, the diamond fin type(Type B-1) is analyzed as the most stable in velocity. And the results of local pressure drop show that the difference of pressure coefficient of Type B-1 is computed as 0.59, and that of Type A-3 is 2.44. Meanwhile, from the effect analysis of the number of module, the flow conflict happens and the pressure difference between before and after the module increases if there are over 3 modules inserted.

Effect of Feeding Probiotics on Performance and Intestinal Microflora of Broiler Chicks (생균제의 급여가 육계의 생산성과 장내 미생물의 변화에 미치는 영향)

  • 류경선;박홍석
    • Korean Journal of Poultry Science
    • /
    • v.25 no.1
    • /
    • pp.31-37
    • /
    • 1998
  • Two experiment were conducted to evaluate the feeding value of probiotics for the broiler chicks. Basal diets based on corn and soybean meal with no supplemental probiotics contained 21% dietary crude protein for the first 3 weeks and 19% for the rest of two weeks. In experiment 1, 0.2 % probiotics containing 2X 10 6 cfu /ml of Saccharomyces cerevisiae(S), Clostridium butyricum(C), Lactobacillus acidophilus(L), Bacillus polyfermenticus(B) were respectively supplemented to control groups. Two hundred day-olo chicks were randomly assigned to five treatments which had four replicates of 10 chicks each per treatment. Weight gain, feed consurnption, feed conversion ratio (FCR) were weekly measured for 5 weeks. The number of intestinal microflora was examined at the end of experiment. In experiment 1, Weight gain and feed intake of chicks fed probiotics exhibited a significant response compared to those of control for the first three weeks(P<0.01). Weight gain of S or C treatments was higher than that of control for the rest of two weeks, whereas it was significantly lower in L and B treatments than S or C treatments (P<0.01). Chicks fed S or C was significantly increased weight gain(P <0.05) compared to that of control at five weeks of age. FCR of C treatment seemed to improve relative to other supplemental probiotics groups, but was not significantly different. The number of intestinal anaerobes and Lactobacillus in large intestine of chicks fed probiotics supplements was significantly decreased compared to control groups(P<0.01). In experiment 2, there were six treatments: Ti, control; T2, 0.2%S; T3, 0.2%S + 0.2%C; T4, 0.2%S + 0.2%L; T5, 0.2%S + 0.2%B; T6, 0.2%S + 0.1%C + o.i%L + 0.1%B. Control diet based on corn soybean meal contained 21% CP and 3,2OOca1 /g ME with no probiotics. There were four replicates of 10 chicks each per treatment. Weight gain of chicks fed probiotics tended to increase compared to control groups, but were not significantly different between them. FCR was also improved in probiotics treatments. However, there were no significant differences between probiotics supplementation and control groups. The results of these experiments indicated that dietary supplemental probiotics improved weight gain, feed efficiency for the first three weeks of young broiler chicks, whereas supplementation of C, L, B combined probiotics to young broiler chicks was not superior to those of single or two probiotics.

  • PDF