Acknowledgement
Supported by : 오스템
References
- Branemark P-I. Osseointegration and its experimental background. J Prosthet Dent 1983; 50: 399-410 https://doi.org/10.1016/S0022-3913(83)80101-2
- Albrektsson T, Branemark P-I, Hasson HA, Lindstrom J. Osseointegrated titanium implants. Acta Orthp Scand 1981; 52: 155-170 https://doi.org/10.3109/17453678108991776
- Wennerberg A, Albrektsson T. Suggested guidelines for the topographic evaluation of implant surfaces. Int J Oral Maxillofac Implants 2000; 15: 331-344
- Eliades T. Passive film growth on titanium alloys : Physico-chemical and biological consideration. Int J Oral Maxillofac Implants 1997; 12: 621-627
- Pan J, Thierry D, Leygraf C. Electrochemical impedance spectroscopy study of the passive oxide film on titanium for implant application. Electrochim Acta 1996; 41: 1143-1153 https://doi.org/10.1016/0013-4686(95)00465-3
- Lausmaa J, Linder L. Surface spectroscopic characterization of titanium implants after separation from plastic-embedded tissue. Biomaterials 1988; 9: 277-280 https://doi.org/10.1016/0142-9612(88)90098-1
- Keller JC, Stanford CM, Wightman JP, Draughn RA, Zaharias R. Characterization of titanium implant surfaces. J Biomed Mater Res 1994; 28: 939-946 https://doi.org/10.1002/jbm.820280813
- Kieswetter K, Schwarz Z, Dean DD, Boyan BD. The role of implant surface characteristics in the healing of bone. Crit Rev Oral Biol Med 1996; 7: 329-345 https://doi.org/10.1177/10454411960070040301
- Pouilleau J, Devilliers D, Garrido F, Durand-Vidal S, Mahe E. Structure and composition of passive titanium oxide film. Mater Sci Eng 1997; 47: 235-243 https://doi.org/10.1016/S0921-5107(97)00043-3
- Sui YT, Johansson CB, Petronics S, Krozer A, Jeong YS, Wennerberg A, Albrektsson T. Characteristics of the surface oxides on turned and electrochemically oxidized pure titanium implants up to dielectric breakdown the oxide thickness, micropore configurations, surface roughness, crystal structure and chemical composition. Biomaterials 2002; 23: 491-501 https://doi.org/10.1016/S0142-9612(01)00131-4
- Choi JW, Kim KN, Heo SJ, Chang IT, Han JH, Baik HK, Choi YC, Wennerberg A. The effects of various surface treatment methods on the osseointegration. J Korean Acad Prosthodont 2001; 39: 71-83
- Ivanoff CJ, Widmark G, Johanssen C, Wennerberg A. Histologic evaluation of bone response to oxidized and turned titanium micro-implnants in human jaw bone. Int J Oral Maxillofac Implants 2003; 18: 341-348
- Sui YT, Johansson CB, Jeong Y, Roser K, Wennerberg A, Albrektsson T. Oxidized implants and their influence on the bone response. J Mater Sci Mater Med 2001; 12: 1025-1031 https://doi.org/10.1023/A:1012837905910
- Sul YT, Johansson CB, Jeong Y, Wennerberg A, Albrektsson T. Resonance frequency and removal torque analysis of implants with turned and anodized surface oxides. Clin Oral Implants Res 2002; 13: 252-259 https://doi.org/10.1034/j.1600-0501.2002.130304.x
- Ishizawa H, Ogino M. Characterization of thin hydroxyapatite layers formed on anodic titanium oxide films containing Ca and P by hydrothermal treatment. J Biomed Mater Res 1995; 29: 1071-1079 https://doi.org/10.1002/jbm.820290907
- Li LH, Kong YM, Kim HW, Kim YW, Kim HE, Heo SJ, Koak JY. Improved biological performance of Ti implants due to surface modification by micro-arc oxidation. Biomaterials 2004; 25: 2867-2876 https://doi.org/10.1016/j.biomaterials.2003.09.048
- Yang B, Uchida M, Kim HM, Zhang X, Kokubo T. Preparation of bioactive metal via anodic oxidation treatment. Biomaterials 2004; 25: 1003-1010 https://doi.org/10.1016/S0142-9612(03)00626-4
- Cho DH, Lim JH. A study on the surface roughness and initial stability of various dental implants. J Korean Acad Stomatognathic Function and Occlusion 2000; 16: 197-210
- Kang BS, Cho IH. A histomorphometric and stability of two kinds of implants with different surface roughness. J Korean Acad Oral Maxillofac Implants 2001; 5: 42-69
- Wong M, Eulenberger J, Schenk R, Hunziker E. Effect of surface topography on the osseointegration of implant materials in trabecular bone. J Biomed Mater Res 1995; 29: 1567-1575 https://doi.org/10.1002/jbm.820291213
- Ungersbock A, Pohler O, Perren SM. Evaluation of the soft tissue interface at titaniwn implants with different surface treatments : experimental study on rabbits. Biomed Mater Eng 1994; 4: 317-325
- Sul YT, Johansson CB, Wennerberg A, Cho LR, Chang BS, Albrektsson T. Optimal surface proporties of oxidized implants for reinforcement of osseointegration : surface chemistry, oxide thickness, porosity, roughness, and crystal structure. Int J Oral Maxillofac Implants 2005; 20: 349-359
- De Maeztu MA, Alava JI, Gay-Escoda C. Ion implantation: Surface treatment for improving the bone integration of titanium and Ti6A14V dental implants. Clin Oral Implants Res 2003; 14: 57-62 https://doi.org/10.1034/j.1600-0501.2003.140108.x
- Sul YT, Byon ES, Jeong Y. Biochemical measurements of calcium-incorporated oxidized implants in rabbit bone: effect of calcium surface chemistry of a novel implant. Clin Implant Dent Relat Res 2004; 6: 101-110 https://doi.org/10.1111/j.1708-8208.2004.tb00032.x
- Ellingsen JE, Johansson CB, Wennerberg A, Holmen A. Improved retention and bone-to-implant contact with fluoride-modified titanium implants. Int J Oral Maxillofac Implants 2004; 19: 659-666
- Ellingsen JE. On the properties of surface-modified titanium. In: Davies JE(ed). Bone Engineering. Toronto: EmSquared, 2000; 183-189
- Gedalia I, Zipkin I. The role of fluoride in bone structure. St. Louis: Warren H. Green, 1973
- Ellingsen JE. Pre-treatment of titanium implants with fluoride improves their retention in bone. J Mater Sci Mater Med 1995; 6: 749-753 https://doi.org/10.1007/BF00134312
- Shteyer A, Liberman R, Simkin A. Gedalia I. Effect of local application of fluoride on healing of experimental bone fractures in rabbits. Calcif Tissue Res 1977; 22: 297-302 https://doi.org/10.1007/BF02010368
- Kasemo B, Lausmaa J. Biomaterials and implant surfaces; A surface science approach. Int J Oral Maxillofac Implants 1988; 3: 247-259
- Larsson C, Thomsen P, Aronsson BO, Rodahl M, Lausmaa J. Bone response to surface modified titanium implants with different oxide thickness and morphology. Biomaterials 1994; 15: 1062-1074 https://doi.org/10.1016/0142-9612(94)90092-2
- Lim YJ, Oshida Y, Andres CJ, Barco MT. Surface characterizations of variously treated titanium materials. Int J Oral Maxillofac Implants 2001; 16: 333-342
- Buser D, Schenk RK, Steinmann S, Fiorollini JP, Fox CH, Stich H. Influence of surface characteristics on bone integration of titanium implants. A histomorphometric study in miniature. J Biomed Mater Res 1991; 25: 889-902 https://doi.org/10.1002/jbm.820250708
- Taylor GC, Waddington RJ, Moseley R, Williams KR, Embery G. Influence of titanium oxide and titanium peroxy gel on the breakdown of hyaluronan by reactive oxygen species. Biomaterials 1996; 13: 1313-1319
- Lee SH, Cho IH. Surface characteristics and bioactivity of anodically oxidized titanium surfaces. Ph.D Thesis in 2004; College of Dentistry, Dankook University, Korea
- Bosetti M, Masse A, Tobin E, Cannas M. In vivo evaluation of bone tissue behavior on ion implanted surfaces. J Mater Sci Mater Med 2001; 12: 431-435 https://doi.org/10.1023/A:1011253121063
- Nishiguchi S, Kato H, Hujita H, Oka M, Kim HM, Kokubo T. Titanium metals form direct bonding to bone after alkali and heat treatments, Biomaterials 2001; 22: 2525-2533 https://doi.org/10.1016/S0142-9612(00)00443-9
- Kim HM. Ceramic bioactivity and related biomimetic strategy. Current Opinion in Solid State and Materials Science 2003; 7: 289-299 https://doi.org/10.1016/j.cossms.2003.09.014
- Kokubo T, Kim HM, Kawashita M, Nakamura T. Bioactive metals: preparation and properties. J Mater Sci Mater Med 2004; 15: 99-107 https://doi.org/10.1023/B:JMSM.0000011809.36275.0c
- Uchida M, Kim HM, Kokubo T, Fujibayashi S, Nakamura T. Structural dependence of apatite formation on titania gels in a simulated body fluid. J Biomed Mater Res 2003; 64: 164-170
- Hero H, Wie H, Jorgensen RB, Ruyter IE. Hydroxyapatite coating on Ti produced by hot isostatic pressing. J Biomed Mater Res 1994 Mar; 28: 343-348 https://doi.org/10.1002/jbm.820280308
- Savarino L, Fini M, Ciapetti G, Cenni E, Granchi D, Baldimi N, Greco M, Rizzi G, Giardino R, Giunti A. Biologic effects of surface roughness and fluorhydroxyapatite coating on osteointegration in external fixation systems : an in vivo experimental study. J Biomed Mater Res A 2003; 66: 652-662