• Title/Summary/Keyword: Threshold temperature

Search Result 779, Processing Time 0.022 seconds

Radiation Effects on the Power MOSFET for Space Applications

  • Lho, Young-Hwan;Kim, Ki-Yup
    • ETRI Journal
    • /
    • v.27 no.4
    • /
    • pp.449-452
    • /
    • 2005
  • The electrical characteristics of solid state devices such as the bipolar junction transistor (BJT), metal-oxide semiconductor field-effect transistor (MOSFET), and other active devices are altered by impinging photon radiation and temperature in the space environment. In this paper, the threshold voltage, the breakdown voltage, and the on-resistance for two kinds of MOSFETs (200 V and 100 V of $V_{DSS}$) are tested for ${\gamma}-irradiation$ and compared with the electrical specifications under the pre- and post-irradiation low dose rates of 4.97 and 9.55 rad/s as well as at a maximum total dose of 30 krad. In our experiment, the ${\gamma}-radiation$ facility using a low dose, available at Korea Atomic Energy Research Institute (KAERI), has been applied on two commercially available International Rectifier (IR) products, IRFP250 and IRF540.

  • PDF

The Pulsed Id-Vg methodology and Its Application to the Electron Trapping Characterization of High-κ gate Dielectrics

  • Young, Chadwin D.;Heh, Dawei;Choi, Ri-No;Lee, Byoung-Hun;Bersuker, Gennadi
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.10 no.2
    • /
    • pp.79-99
    • /
    • 2010
  • Pulsed current-voltage (I-V) methods are introduced to evaluate the impact of fast transient charge trapping on the performance of high-k dielectric transistors. Several pulsed I-V measurement configurations and measurement requirements are critically reviewed. Properly configured pulsed I-V measurements are shown to be capable of extracting such device characteristics as trap-free mobility, trap-induced threshold voltage shift (${\Delta}V_t$), as well as effective fast transient trap density. The results demonstrate that the pulsed I-V measurements are an essential technique for evaluating high-$\kappa$ gate dielectric devices.

Evaluation of Characteristics and Useful Life of Rubber Spring for Railway Vehicle

  • Woo, Chang-Su;Park, Hyun-Sung;Park, Dong-Chul
    • International Journal of Railway
    • /
    • v.1 no.3
    • /
    • pp.122-127
    • /
    • 2008
  • Rubber components are widely used in many application such as vibration isolators, damping, ride quality. Rubber spring is used in primary suspension system for railway vehicle. Characteristics and useful life prediction of rubber spring was very important in design procedure to assure the safety and reliability. Non-linear properties of rubber material which are described as strain energy function are important parameter to design and evaluate of rubber spring. These are determined by physical tests which are uniaxial tension, equi-biaxial tension and pure shear test. The computer simulation was executed to predict and evaluate the load capacity and stiffness for rubber spring. In order to investigate the useful life, the acceleration test were carried out. Acceleration test results changes as the threshold are used for assessment of the useful life and time to threshold value were plotted against reciprocal of absolute temperature to give the Arrhenius plot. By using the acceleration test, several useful life prediction for rubber spring were proposed.

  • PDF

Characteristics Evaluation and Useful Life Prediction of Rubber Spring for Railway Vehicle (전동차용 방진고무스프링 특성평가 및 사용수명 예측)

  • Woo, Chang-Su;Park, Dong-Chul
    • Proceedings of the KSR Conference
    • /
    • 2006.11b
    • /
    • pp.104-111
    • /
    • 2006
  • The non-linear properties of rubber material which are described as strain energy function are important parameter to design and evaluate of rubber spring. These are determined by material tests which are uni-axial tension and bi-axial tension. The computer simulation using the nonlinear element analysis program executed to predict and evaluate the load capacity and stiffness for chevron spring. In order to investigate the heat-aging effects on the rubber material properties, the acceleration test were carried out. Compression set results changes as the threshold are used for assessment of the useful life and time to threshold value were plotted against reciprocal of absolute temperature to give the Arrhenius plot. By using the compression set test, several useful life prediction for rubber material were proposed.

  • PDF

Preliminary study on the visual sensitivity of Oreochromis niloticus using LED light source for the aquaculture development in Uganda

  • Esther Kagoya;Kyoungmi Kang
    • Fisheries and Aquatic Sciences
    • /
    • v.26 no.8
    • /
    • pp.514-523
    • /
    • 2023
  • The visible threshold of Oreochromis niloticus responded to high light intensity under short wavelengths, whereas the response to low light intensity under long wavelengths was low, with a minimum visual threshold of 574 nm of LED lights. Movement distance of O. niloticus was dropped at 31℃ and increased abnormally at 37℃ under natural light. Comparing movement distance under red (622 nm) and green (518 nm) lights of LED, movement distance and swimming speed under red and green lights were higher than under natural light. However, the movement distance decreased rapidly at 31℃ under red light and lowest at 33℃ under green light. After that, there was a tendency to adapt to high water temperatures gradually. Consequently, red and green lights may be recommended for O. niloticus's aquaculture because the red and green lights have a positive effect on growth performance, survival rate, and metabolism, as shown in previous studies. It is necessary to control the water temperature below 32℃ because abnormal behavior above 32℃ revealed under red and green LED lights and natural light.

A Study on The Effect of High Temperature on Fatigue Life of The Vehicle Spring Steel (쇼트피이닝 가공된 차량용 스프링강의 피로수명에 미치는 고온의 영향)

  • Park, Keyoung-Dong;Ha, Keyoung-Jun
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.167-172
    • /
    • 2002
  • In this study, CT specimens were prepared from spring steel(SUP9) processed shot peening which was room temperature, high temperature experiment. And ire got the following characteristics from fatigue crack growth test carried out in the environment of room, and high temperature at $25^{\circ}C,\;100^{\circ}C,\;150^{\circ}C$ and $180^{\circ}C$ in the range of stress ratio of 0.3 by means of opening mode displacement. The threshold stress intensity factor range ${\Delta}Kth$ in the early stage of fatigue crack growth (Region I) and stress intensity (actor range ${\Delta}K$ in the stable of fatigue crack growth (Region II) was decreased in proportion to descend temperature. It assumed that the fatigue resistance characteristics and fracture strength at high temperature is considerable higher than that of room temperature in the early stage and stable of fatigue crack growth region.

  • PDF

The Effects of Transcutaneous Electrical Nerve Stimulation on the Pain Threshold and the Plasma Beta-endorphin Level (경피(經皮) 신경(神經) 자극(刺戟)이 통증역치(痛症閾値)와 혈장(血漿) Beta-endorphine치(値)에 미치는 영향(影響))

  • Kil, Ho-Yeong;Lee, Doo-Ik;Kim, Chul-Ho;Kim, Keon-Sik;Choi, Young-Kyoo;Shin, Kwang-Il
    • The Korean Journal of Pain
    • /
    • v.2 no.2
    • /
    • pp.145-154
    • /
    • 1989
  • Pain is a common and important clinical symptom, and treatments aimed at relieving pain have a central position in medical practice. Recently Transcutaneous Electrical Nerve Stimulation (TENS) has been effectively used to control acute and chronic conditions that produce pain. But the mechanism of analgesia resulting from TENS remains obscure. In order to investigate the analgesic effect of TENS and it's action mechanism, TENS was applied in 40 rabbits with different frequencies, low frequency (2Hz) and high frequency (100Hz), for 20 minutes. And the pain threshold was measured by the temperature before and after stimulation, and an attempt was made to antagonize the stimulation effect with naloxone pretreatment (0.4 mg/kg) The results are as follows: 1) Both low frequency and high frequency TENS resulted in increasing the pain threshold significantly (Both p<0.01). 2) Naloxone pretreatment could antagonize the effect of increasing the pain threshold with low frequency TENS significantly (p<0.01), but not with high frequency TENS. Plasma beta-endorphin was measured by radioimmunoassay using an Beta-Endorphin Kit (Immunonuclear Corporation, Stillwater, Minnesota, USA) and Automatic Gamma Scintillation Counter (Micromedic System 4/2000) before and after stimulation. An attempt was made to reverse the stimulation effect with naloxone pretreatment (0.4 mg/kg). The results are as follows: 1) Low frequency TENS resulted in increasing the level of plasma beta.endorphin significantly (p<0.01), but high frequency TENS did not. 2) Naloxone pretreatment could reverse the effect of increasing the plasma beta-endorphin level with low frequency TENS significantly (p<0.01).

  • PDF

Theoretical models of threshold stress intensity factor and critical hydride length for delayed hydride cracking considering thermal stresses

  • Zhang, Jingyu;Zhu, Jiacheng;Ding, Shurong;Chen, Liang;Li, Wenjie;Pang, Hua
    • Nuclear Engineering and Technology
    • /
    • v.50 no.7
    • /
    • pp.1138-1147
    • /
    • 2018
  • Delayed hydride cracking (DHC) is an important failure mechanism for Zircaloy tubes in the demanding environment of nuclear reactors. The threshold stress intensity factor, $K_{IH}$, and critical hydride length, $l_C$, are important parameters to evaluate DHC. Theoretical models of them are developed for Zircaloy tubes undergoing non-homogenous temperature loading, with new stress distributions ahead of the crack tip and thermal stresses involved. A new stress distribution in the plastic zone ahead of the crack tip is proposed according to the fracture mechanics theory of second-order estimate of plastic zone size. The developed models with fewer fitting parameters are validated with the experimental results for $K_{IH}$ and $l_C$. The research results for radial cracking cases indicate that a better agreement for $K_{IH}$ can be achieved; the negative axial thermal stresses can lessen $K_{IH}$ and enlarge the critical hydride length, so its effect should be considered in the safety evaluation and constraint design for fuel rods; the critical hydride length $l_C$ changes slightly in a certain range of stress intensity factors, which interprets the phenomenon that the DHC velocity varies slowly in the steady crack growth stage. Besides, the sensitivity analysis of model parameters demonstrates that an increase in yield strength of zircaloy will result in a decrease in the critical hydride length $l_C$, and $K_{IH}$ will firstly decrease and then have a trend to increase with the yield strength of Zircaloy; higher fracture strength of hydrided zircaloy will lead to very high values of threshold stress intensity factor and critical hydride length at higher temperatures, which might be the main mechanism of crack arrest for some Zircaloy materials.

Respiration in the Adult of the Water Striders, Gerris paludum insuralis(Insecta, Hemiptera, Gerridae) (소금쟁이(G. paludum insuralis)성체의 흐름)

  • Park, Sang-Ock;Joo, Eun-Young
    • The Korean Journal of Zoology
    • /
    • v.29 no.3
    • /
    • pp.201-207
    • /
    • 1986
  • The authors attempted to investigate the oxygen consumption rate of sexuals in the water-striders, Gerris paludum insuralis, at four temperature groups of 25, 30, 35 and $40^\\circ C$ in a series of studies on respiration of a heminetabolous insects. THe results are summarised as follows: (1) At $30^\\circ C$, the change of oxygen consumption rate according to the lapse of time was small in comparison with the other three temperature groups which shows a cyclic decreasing pattern. The rate during initial and final 5 minutes was much alike. Thereupon, the optimum temperature was regarded as $30^\\circ C$. (2) The oxygen consumption rate of male was higher than that of female. (3) The oxygen consumption rates at 25, 30, 35 and $40^\\circ C$ were 0.42, 0.49, 0.79 and 1.11 $\\mu$l/mg/h respectively. That is, the rate was increased as the temperature was increased. (4) The $Q_10$ of male showed a high value in the lower temperature interval ($25^\\circ C \\sim 35^\\circ C$), but the female showed a high value in the higher temperature interval ($30^\\circ C \\sim 40^\\circ C$). The mean $Q_10$ was 2.12. (5) The respiratory rate was decreased as the body weight was increased in the above fresh weight of 10mg and dry weight 5 mg. (6) The upper temperature threshold for respiration was $48.31^\\circ C$ and the lower temperature threshold was $17.68^\\circ C$. (7) The ceasing time of breathing at the other three temperature groups except $30^\\circ C$ was infered to be about 110 minutes after the start of experiment.

  • PDF

Analysis of the electrical characteristics of HV-MOSFET under various temperature (고내압 MOSFET의 고온 영역에서의 전기적 특성 분석)

  • Koo, Yong-Seo
    • Journal of IKEEE
    • /
    • v.11 no.3
    • /
    • pp.95-99
    • /
    • 2007
  • In this study, the electrical characteristics of Symmetric and Asymmetric High Voltage MOSFET(HV-MOSFET) under high temperature were investigated. And, the specific on-resistance, threshold voltage, transconductance, drain current of the HV-MOSFETs were measured over a temperatures range of 300K ${\leq}$ T ${\leq}$400K. From the result of measured data, specific on-resistance increases slightly with increasing temperature. Especially, at high temperature(at 400K) specific on-resistance was increased about 30% than that in room temperature. And, in high temperature condition (at 400K), drain current was decreased about 30%, Also, transconductance(gm) was decreases with increasing temperature.

  • PDF