삼상 자속구속형 한류기의 동작모드분석 (The Analysis of Operation Mode of Three-Phase Flux-Lock Type Superconducting Fault Currents Limiter)

  • 황종선;최효상;박형민;조용선;이나영;남긍현;한태희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 영호남 합동 학술대회 및 춘계학술대회 논문집 센서 박막 기술교육
    • /
    • pp.46-48
    • /
    • 2006
  • We investigated the analysis of operation mode of three-phase flux-lake type superconducting fault current limiter(SFCL). The structure of the integrated three-phase flux-lock type SFCL consisted of three-phase flux-lock reactor wound on an iron core with the same turn between coil 1 and coil 2 in each phase. When the SFCL is operated under the normal condition, the flux generated in the iron core is zero because the flux generated between two coils of each single phase is canceled out. Therefore, the SFCL's impedance is zero and the SFCL has negligible influence on the power system, However, if a fault occurs in any single-phase among three phases, the flux generated in the iron core is not zero any more. The flux makes elements of all phase-quench irrespective of the fault type, which reduces the current of fault phase as well as the current of sound phase.

  • PDF

YBCO CC를 이용한 분리된 삼상 자속구속형 고온초전도 전류제한기의 전압 증가에 따른 전류제한 특성 (Current Limiting Characteristics According to the Increase of Voltage in Separated Three-Phase Flux-Lock Type Superconducting Fault Current Limiter Using YBCO CC)

  • 두승규;두호익;김민주;김용진;이동혁;한병성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 하계학술대회 논문집
    • /
    • pp.355-356
    • /
    • 2009
  • In this paper, we investigated the fault current limiting characteristics according to the increase of voltage in the separates three-phase flux-lock type high-Tc superconducting fault current limiter using YBCO CC. The separated three-phase flux-lock type SFCL consists of single-phase flux-phase type SFCL in each phase. Superconductor was using the YBCO CC. To analyze the current limiting characteristics of a three-phase flux-lock type SFCL, the short circuit experiments were carded out fault such as the triple line-to-ground fault. The experimental result shows that fault current limiting characteristics was improved on the high voltage level.

  • PDF

대역폭이 향상된 직접변환 Six-port 위상 상관기 성능분석 (Performance Analysis of Improved Direct Conversion Six-port Phase Correlator)

  • 유재두;김영완
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2007년도 춘계종합학술대회
    • /
    • pp.91-94
    • /
    • 2007
  • 본 논문에서는 $90^{\circ}$ hybrid branch-line coupler와 three-arm branch $90^{\circ}$ hybrid coupler를 이용하여 설계한 six-port 위상 상관기를 ADS2003A을 사용하여 모의 실험하고 성능을 분석하였다. Three-arm branch $90^{\circ}$ hybrid coupler를 이용한 six-port 위상 상관기가 기존의 $90^{\circ}$ hybrid coupler를 이용한 six-port 위상 상관기보다 약 5배정도의 광대역 특성을 보였다. 두 개의 six-port 위상 상관기의 성능을 비교 검증하기 위하여 six-port 위상 상관기를 제작 평가하였다 측정된 두 개의 six-port 위상 상관기의 특성은 시뮬레이션 데이터와 거의 일치하였다.

  • PDF

Design and Implementation of a Multi Level Three-Phase Inverter with Less Switches and Low Output Voltage Distortion

  • Ahmed, Mahrous E.;Mekhilef, Saad
    • Journal of Power Electronics
    • /
    • 제9권4호
    • /
    • pp.593-603
    • /
    • 2009
  • This paper proposes and describes the design and operational principles of a three-phase three-level nine switch voltage source inverter. The proposed topology consists of three bi-directional switches inserted between the source and the full-bridge power switches of the classical three-phase inverter. As a result, a three-level output voltage waveform and a significant suppression of load harmonics contents are obtained at the inverter output. The harmonics content of the proposed multilevel inverter can be reduced by half compared with two-level inverters. A Fourier analysis of the output waveform is performed and the design is optimized to obtain the minimum total harmonic distortion. The full-bridge power switches of the classical three-phase inverter operate at the line frequency of 50Hz, while the auxiliary circuit switches operate at twice the line frequency. To validate the proposed topology, both simulation and analysis have been performed. In addition, a prototype has been designed, implemented and tested. Selected simulation and experimental results have been provided.

결상 시 누전전류 발생과 오동작 방지 기능을 갖는 결상보호기 개발에 관한 연구 (A Study on Development of Open-Phase Protector Having Leakage Current Generation and Incapable Operation Prevention at Open-Phase Accident)

  • 곽동걸
    • 전기학회논문지
    • /
    • 제64권1호
    • /
    • pp.182-187
    • /
    • 2015
  • In the three-phase power system, when any one-phase or two-phases is open-phase, the unbalanced current flows and the single-phase power supplies to three-phase loads. Specially, motor coil and transformer coil receive over-current. As a result, great damage as well as electrical fire can occur to the power system. In order to improve these problems, this paper proposes that an open-phase detection device is designed by a new algorithm using electric potential difference between the resultant voltage of neutral point and ground, and a control circuit topology of open-phase protector is composed of highly efficient semiconductor devices. It improves response speed and reliability. The control algorithm circuit also operates the cut-off of a conventional residual current protective device (RCD) which flows an enforced leakage current to ground wire at open-phase accident. Furthermore, time delay circuit is added to prevent the incapable operation of open-phase protector about instantaneous open-phase not open-phase fault. The time delay circuit improves more reliability.

대역폭이 향상된 Six-port 위상 상관기 설계 및 성능 분석 (Design and Performance Analysis of Wideband Six-port Phase correlator)

  • 김영완;유재두
    • 한국정보통신학회논문지
    • /
    • 제12권3호
    • /
    • pp.414-419
    • /
    • 2008
  • Six-port 위상 상관기는 한 개의 power divider 와 세 개의 hybrid coupler로 구성되어 진다. 본 논문에서는 광대역 특성을 갖는 three-arm branch $90^{\circ}$ hybrid coupler를 사용한 six-port 위상 상관기를 ADS2003A을 사용하여 중심 주파수 11.85 GHz에서 설계하여 시뮬레이션을 통해 성능을 분석하였다. 모의 실험결과 three-arm branch $90^{\circ}$ hybrid coupler를 이용한 six-port 위상 상관기의 대역폭은 약 1.5GHz$(10.8{\sim}12.3)$로 기존의 $90^{\circ}$ hybrid branch-line coupler를 이용한 six-port 위상 상관기보다 약 5배 정도의 광대역 특성을 보였다. Six-port 위상 상관기의 port간 위상 오차는 $5^{\circ}$ 이하로 양호한 특성을 보였으며, 모의 실험한 결과를 바탕으로 six-port 위상 상관기의 실질적인 성능을 비교 검증하기 위하여 six-port 위상 상관기를 제작하고 성능을 측정하였다. 측정된 six-port 위상 상관기의 특성은 시뮬레이션 데이터와 거의 일치하였다.

Input AC Voltage Sensorless Control Scheme for a Three-Phase PWM Rectifier in Wind Power Generation System

  • Wu, YanJun
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제1권4호
    • /
    • pp.472-476
    • /
    • 2012
  • In this paper, a sensorless control scheme for a three-phase bi-directional voltage-type PWM rectifier in wind power generation system that operates without the input AC voltage sensors (generator side) is described. The basic principles and classification of the PWM rectifier are analyzed, and then the three-phase mathematical model of the input AC voltage sensorless PWM rectifier control system is established. The proposed scheme has been developed in order to lower the cost of the three-phase PWM rectifier but still achieve excellent output voltage regulation, limited current harmonic content, and unity input power factor.

예측 전류를 적용한 3 션트 PWM 인버터의 전류 복원 기법 (three phase current reconstruction method applying predictive current in three shunt sensing PWM inverter)

  • 홍성우;김도윤;원일권;김영렬;원충연
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2016년도 전력전자학술대회 논문집
    • /
    • pp.99-100
    • /
    • 2016
  • In a AC motor used by three phase inverter, the phase current must be measured to control instantaneous torque. It is expensive to use current sensor for measuring current in low cost motor. So, shunt resistor is used to measure current. But, the method sensing the phase current using shunt resistor cannot perform the vector control in high speed because of the area that impossible to restore three phase current. In this paper, predictive current is proposed for reconstructing the current in the impossible current sensing area that reduce the current ripple in TSSI(Three shunt sensing inverter) for PMSM.

  • PDF

Space Vector Modulated Three-Phase Soft-Switching Active Rectifier and Its Performance Evaluations

  • Fujii Yuma;Ahmed Tarek;Imamura Kosuke;Hiraki Eiji;Nakaoka Mutsuo
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 춘계전력전자학술대회 논문집(1)
    • /
    • pp.213-215
    • /
    • 2003
  • This paper presents an instantaneous space vector modulated voltage source type three-phase soft-switching PFC rectifier using a single auxiliary resonant DC Link snubber for alternative energy utilizations. in the first place, the operating principle of an active auxiliary resonant DC link snubber circuit is described including its unique features. In the next place, the simulation analysis of three-phase soft-switching PWM rectifier is implemented, and the operating performances or the three-phase voltage-fed PWM rectifier treated here, which can operate under the conditions of sinewave line current shaping and utility power factor are evaluated and discussed on tile basis of this simulation results.

  • PDF

UPS 기능을 가지는 배터리 기반의 삼상 전력 평준화 시스템 (Three-phase Power Equalizing System with UPS Function based on Battery Storage)

  • 권정민
    • 전력전자학회논문지
    • /
    • 제17권4호
    • /
    • pp.353-358
    • /
    • 2012
  • In this paper, three-phase power equalizing system (PES) with UPS function is proposed. This system is based on NiMH battery with battery management system. The power conversion circuit is composed with the three-phase converter/inverter, the bi-directional converter, and the thyristor switches. The three-phase converter/inverter provides the power to the grid or get the power from the grid. Also, it operates as a UPS. The bi-directional converter charges or discharges the battery. The thyristor switches are used for connecting/disconnecting with the grid and the load. A 15 kW prototype is implemented for the verifying the performance of the proposed system.