• Title/Summary/Keyword: Thermal infrared sensors

Search Result 71, Processing Time 0.028 seconds

The performance evaluation of Stirling cryocooler for thermal imaging system (IV) : Vibration, Noise, Leak test (열상장비용 스터링 극저온 냉동기 특성평가 (IV) : 진동, 소음, 누설시험)

  • 박성제;홍용주;김효봉;김양훈;최상규;나종문
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.10a
    • /
    • pp.167-170
    • /
    • 2003
  • This paper presents the results of a series of performance tests for the Stilting cryocooler. A free piston and free displacer(FPFD) Stilting cryocooler for cooling infrared and cryo-sensors is currently under development at KIMM. Our coolers are specifically designed to work in the thermal imaging device and to meet requirements such as cooling capacity, COP and high reliability. In this work, Stilting cryocooler is designed, manufactured and fabricated, and performance characteristics for the vibration, acoustic noise, EMI and leak rate are evaluated. Vibration outputs are measured to 20KHz for compressor and expander, respectively. And, the objective of noise test is a noise level, less than 30㏈ at 5 m. EMI tests are carried out according to the standard MIL-STD-461C tests RE01 and RE02. Leak test for the Stilting cryocooler is performed by bombing method.

  • PDF

Common Optical System for the Fusion of Three-dimensional Images and Infrared Images

  • Kim, Duck-Lae;Jung, Bo Hee;Kong, Hyun-Bae;Ok, Chang-Min;Lee, Seung-Tae
    • Current Optics and Photonics
    • /
    • v.3 no.1
    • /
    • pp.8-15
    • /
    • 2019
  • We describe a common optical system that merges a LADAR system, which generates a point cloud, and a more traditional imaging system operating in the LWIR, which generates image data. The optimum diameter of the entrance pupil was determined by analysis of detection ranges of the LADAR sensor, and the result was applied to design a common optical system using LADAR sensors and LWIR sensors; the performance of these sensors was then evaluated. The minimum detectable signal of the $128{\times}128-pixel$ LADAR detector was calculated as 20.5 nW. The detection range of the LADAR optical system was calculated to be 1,000 m, and according to the results, the optimum diameter of the entrance pupil was determined to be 15.7 cm. The modulation transfer function (MTF) in relation to the diffraction limit of the designed common optical system was analyzed and, according to the results, the MTF of the LADAR optical system was 98.8% at the spatial frequency of 5 cycles per millimeter, while that of the LWIR optical system was 92.4% at the spatial frequency of 29 cycles per millimeter. The detection, recognition, and identification distances of the LWIR optical system were determined to be 5.12, 2.82, and 1.96 km, respectively.

Full Aperture Black Body Design, Fabrication and Validation for Infrared Detector Calibration (적외선 검출기 검보정을 위한 대구경흑체 설계, 제작 및 검증)

  • Cho, Hyokjin;Seo, Hee-Jun;Kim, Keun-Shik;Park, Sung-Wook;Moon, Guee-Won
    • Aerospace Engineering and Technology
    • /
    • v.12 no.1
    • /
    • pp.40-45
    • /
    • 2013
  • Satellite's infrared detector shall be calibrated under thermal vacuum environment using a reference black body before a launch. The full aperture black body (FABB) as an infrared calibration reference shall be composed of vacuum compatible materials and temperature controlled from $-40^{\circ}C$ to $+40^{\circ}C$ with emissivity higher than 0.95. The temperature homogeneity over the central 80 % area of the FABB front surface shall be better than 2 K. The FABB designed by thermal and flow analysis was $1m{\times}1m{\times}8mm$ copper plate on which black painted aluminum honeycomb core was attached. Copper tubes were welded on the opposite side of the honeycomb core to allow temperature regulated gaseous nitrogen to flow through them. By the FABB validation test, the temperature homogeneity was observed around 1 K using 20 PT100 sensors and modified COTS infrared camera. The emissivity value was 0.975 at $40^{\circ}C$ under atmospheric pressure.

Matching Points Extraction Between Optical and TIR Images by Using SURF and Local Phase Correlation (SURF와 지역적 위상 상관도를 활용한 광학 및 열적외선 영상 간 정합쌍 추출)

  • Han, You Kyung;Choi, Jae Wan
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.23 no.1
    • /
    • pp.81-88
    • /
    • 2015
  • Various satellite sensors having ranges of the visible, infrared, and thermal wavelengths have been launched due to the improvement of hardware technologies of satellite sensors development. According to the development of satellite sensors with various wavelength ranges, the fusion and integration of multisensor images are proceeded. Image matching process is an essential step for the application of multisensor images. Some algorithms, such as SIFT and SURF, have been proposed to co-register satellite images. However, when the existing algorithms are applied to extract matching points between optical and thermal images, high accuracy of co-registration might not be guaranteed because these images have difference spectral and spatial characteristics. In this paper, location of control points in a reference image is extracted by SURF, and then, location of their corresponding pairs is estimated from the correlation of the local similarity. In the case of local similarity, phase correlation method, which is based on fourier transformation, is applied. In the experiments by simulated, Landsat-8, and ASTER datasets, the proposed algorithm could extract reliable matching points compared to the existing SURF-based method.

Stealth, electromagnetic interception, and electrical properties of aluminum sputtered clothing materials - Focusing on the density change - (알루미늄 스퍼터링 처리 의류소재의 스텔스 특성과 전자파 차단 및 전기적 특성에 관한 연구 - 밀도 변화를 중심으로 -)

  • Han, Hye Ree
    • The Research Journal of the Costume Culture
    • /
    • v.30 no.4
    • /
    • pp.579-593
    • /
    • 2022
  • This study examines the surface characteristics, electrical conductivity, electromagnetic wave blocking characteristics, infrared (IR) transmittance, stealth function, thermal characteristics, and moisture characteristics of IR thermal imaging cameras. Nylon film (NFi), nylon fabric (NFa), and 5 types of nylon mesh were selected as the base materials for aluminum sputtering, and aluminum sputtering was performed to study IR thermal imaging, color difference, temperature change, and so on, and the relationship with infrared transmittance was assessed. The electrical conductivity was measured and the aluminum-sputtered nylon film demonstrated 25.6kΩ of surface resistance and high electrical conductivity. In addition, the electromagnetic wave shielding characteristics of the sputtering-treated nylon film samples were noticeably increased as a result of aluminum sputtering treatment as measured by the electromagnetic wave blocking characteristics. When NFi and NFa samples with single-sided sputtering were placed on the human body (sputtering layer faced the outside air) and imaged using IR thermographic cameras, the sputtering layer displayed a color similar to the surroundings, showing a stealth effect. Moreover, the tighter the sample density, the better the stealth function. According to the L, a, b measurements, when the sputtering layer of NFi and NFa samples faced the outside air, the value of a was generally high, thereby demonstrating a concealing effect, and the △E value was also high at 124.2 and 93.9, revealing a significant difference between the treated and untreated samples. This research may be applicable to various fields, such as the military wear, conductive sensors, electromagnetic wave shielding film, and others.

The fabrication of bolometric IR detector for glucose concentration detection (글루코오스 농도 측정을 위한 볼로미터 타입의 적외선 센서 제작)

  • Choi, Ju-Chan;Jung, Ho;Park, Kun-Sik;Park, Jong-Moon;Koo, Jin-Gun;Kang, Jin-Yeong;Kong, Seong-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.17 no.4
    • /
    • pp.250-255
    • /
    • 2008
  • A vanadium pentoxide ($V_2O_5$)-based bolometric infrared (IR) sensor has been designed and fabricated using micro electro mechanical systems (MEMS) technology for glucose detection and its resistive characteristics has been illustrated. The proposed bolometric infrared sensor is composed of the vanadium pentoxide array that shows superior temperature coefficient of resistance (TCR) and standard silicon micromachining compatibility. In order to achieve the best performance, deposited $V_2O_5$ thin film is optimized by adequate rapid thermal annealing (RTA) process. Annealed vanadium oxide thin film has demonstrated a linear characteristic and relatively high TCR value (${-4}%/^{\circ}C$). The resistance of vanadium oxide is changed by IR intensity based on glucose concentration.

Water Detection in an Open Environment: A Comprehensive Review

  • Muhammad Abdullah, Sandhu;Asjad, Amin;Muhammad Ali, Qureshi
    • International Journal of Computer Science & Network Security
    • /
    • v.23 no.1
    • /
    • pp.1-10
    • /
    • 2023
  • Open surface water body extraction is gaining popularity in recent years due to its versatile applications. Multiple techniques are used for water detection based on applications. Different applications of Radar as LADAR, Ground-penetrating, synthetic aperture, and sounding radars are used to detect water. Shortwave infrared, thermal, optical, and multi-spectral sensors are widely used to detect water bodies. A stereo camera is another way to detect water and different methods are applied to the images of stereo cameras such as deep learning, machine learning, polarization, color variations, and descriptors are used to segment water and no water areas. The Satellite is also used at a high level to get water imagery and the captured imagery is processed using various methods such as features extraction, thresholding, entropy-based, and machine learning to find water on the surface. In this paper, we have summarized all the available methods to detect water areas. The main focus of this survey is on water detection especially in small patches or in small areas. The second aim of this survey is to detect water hazards for unmanned vehicles and off-sure navigation.

Development of Vision based Passenger Monitoring System for Passenger's Safety in Railway Station (철도 승강장 승객 안전을 위한 영상처리식 모니터링시스템 개발)

  • Oh, Seh-Chan;Park, Sung-Hyuk;Lee, Han-Min;Kim, Gil-Dong;Lee, Chang-Mu
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.1354-1359
    • /
    • 2008
  • In this paper, we propose a vision based passenger monitoring system for passenger's safety in railway station. Since 2005, Korea Railroad Research Institute (KRRI) has developed a vision based monitoring system, funded by Korean government, for passenger's safety in railway station. The proposed system uses various types of sensors, such as, stereo camera, thermal-camera and infrared sensor, in order to detects danger situations in platform area. Especially, detection process of the system exploits the stereo vision algorithm to improve detection accuracy. The paper describes the overall system configuration and proposed detection algorithm, and then verifies the system performance with extensive experimental results in a real station environment.

  • PDF

A study on the performance characteristics of rotary type Stirling cryocooler (일체형 스터링 냉동기의 설계, 제작 및 성능특성에 관한 연구)

  • Park, S.J.;Hong, Y.J.;Kim, H.B.;Kim, Y.H.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.8 no.1
    • /
    • pp.54-58
    • /
    • 2006
  • Stirling cryocooler is relatively compact, reliable, commercially available. and uses helium as a working fluid. Over the past decade and a half, there has been rapid development of Stirling cryocooler, mainly for military and space applications. Stirling cryocoolers have been widely used lot the cooling of infrared sensors and high temperature superconducting filters to the temperature of the liquid nitrogen. The Stirling cryocooler with the rotary compressor is applicable to the cooling device for the compact mobile thermal imaging system, because the cryocoolers have the compact structure and light weight. In this paper, integral Stirling cryocooler is designed, manufactured and fabricated, and performance characteristics are investigated. This cooler delivers approximately 0.6W cooling at 80K for 20W of input power from 24V DC power supply.

Structure optimization and characterization of a microbolometer for a CO2 detector (이산화탄소 감지소자를 위한 마이크로볼로미터 구조 최적화 및 특성연구)

  • Seo, Ho-Won;Kim, Tae-Geun;Moon, Sung
    • Journal of Sensor Science and Technology
    • /
    • v.17 no.1
    • /
    • pp.75-80
    • /
    • 2008
  • In this work, we optimized a microbolometer for application of a $CO_2$ detector by using MEMS technology. We fabricated a stable thermal isolation structure by varying the lengths of supporting legs which affect bolometer performance. We could fabricate more stable thermal isolation structure for the microbolometer through the results of ANSYS simulations, and minimize the fabrication processes by using bulk micromachining to use a $CO_2$ detector. The microbolometer shows a detectivity of $2.5{\times}109$ cmHz$^{1/2}$/W at a chopper frequency of 8 Hz and a bias current of $6.25\;{\mu}A$ with a vacuum package of about $3.0{\times}10.3$ torr. Therefore, we put to conclusion that the microbolometer optimized in this experiment could be useful for the application of a $CO_2$ detector.