• 제목/요약/키워드: The coefficient of variability

검색결과 361건 처리시간 0.028초

FIR CV-EWMA 관리도 (FIR CV-EWMA Control Chart)

  • 홍의표;강해운;강창욱;백재원
    • 산업경영시스템학회지
    • /
    • 제33권3호
    • /
    • pp.146-153
    • /
    • 2010
  • When the production run is short and process parameters change frequently, it is difficult to monitor the process using traditional control charts. In such a case, the coefficient of variation (CV) is very useful for monitoring the process variability. The CV control chart is an effective tool to control the mean and variability of process simultaneously. The CV control chart, however, is not sensitive at small shifts in the magnitude of CV. The CV-EWMA(exponentially weighted moving average) control chart which was developed recently is effective in detecting a small shifts of CV. Since the CV-EWMA control chart scheme can be viewed as a weighted average of all past and current CV values, it is very sensitive to small change of mean and variability of the process. In this paper, we propose an FIR(Fast initial response) CV-EWMA control chart to improve the sensitivity of a CV-EWMA scheme at process start-up or out-of-control process. Moreover, we suggest the values of design parameters and show the results of the performance study of FIR CV-EWMA control chart by the use of average run length(ARL). Also, we compared the performance of FIR CV-EWMA control chart with that of the CV-EWMA control chart and we found that the CV-EWMA control chart gives longer in-control ARL and much shorter out-of-control ARL.

EWMA 기법을 적용한 CV 관리도의 개발 (Development of CV Control Chart Using EWMA Technique)

  • 홍의표;강창욱;백재원;강해운
    • 산업경영시스템학회지
    • /
    • 제31권4호
    • /
    • pp.114-120
    • /
    • 2008
  • The control chart is widely used statistical process control(SPC) tool that searches for assignable cause of variation and detects any change of process. Generally, ${\bar{X}}-R$ control chart and ${\bar{X}}-S$ are most frequently used. When the production run is short and process parameter changes frequently, it is difficult to monitor the process using traditional control charts. In such a case, the coefficient of variation (CV) is very useful for monitoring the process variability. The CV control chart is an effective tool to control the mean and variability of process simultaneously. The CV control chart, however, is not sensitive at small shift in the magnitude of CV. In this paper, we propose an CV-EWMA (exponentially weighted moving average) control chart which is effective in detecting a small shift of CV. Since the CV-EWMA control chart scheme can be viewed as a weighted average of all past and current CV values, it is very sensitive to small change of mean and variability of the process. We suggest the values of design parameters and show the results of the performance study of CV-EWMA control chart by the use of average run length (ARL). When we compared the performance of CV-EWMA control chart with that of the CV control chart, we found that the CV-EWMA control chart gives longer in-control ARL and much shorter out-of-control ARL.

혁신채택 및 확산이론의 통신방송융합(위성DMB) 서비스 수요추정 응용 (Applications of Innovation Adoption and Diffusion Theory to Demand Estimation for Communications and Media Converging (DMB) Services)

  • 송영화;한현수
    • 경영과학
    • /
    • 제22권1호
    • /
    • pp.179-197
    • /
    • 2005
  • This study examines market acceptance for DMB service, one of the touted new business models in Korea's next-generation mobile communications service market, using adoption end diffusion of innovation as the theoretical framework. Market acceptance for DMB service was assessed by predicting the demand for the service using the Bass model, and the demand variability over time was then analyzed by integrating the innovation adoption model proposed by Rogers (2003). In our estimation of the Bass model, we derived the coefficient of innovation and coefficient of imitation, using actual diffusion data from the mobile telephone service market. The maximum number of subscribers was estimated based on the result of a survey on satellite DMB service. Furthermore, to test the difference in diffusion pattern between mobile phone service and satellite DMB service, we reorganized the demand data along the diffusion timeline according to Rogers' innovation adoption model, using the responses by survey subjects concerning their respective projected time of adoption. The comparison of the two demand prediction models revealed that diffusion for both took place forming a classical S-curve. Concerning variability in demand for DMB service, our findings, much in agreement with Rogers' view, indicated that demand was highly variable over time and depending on the adopter group. In distinguishing adopters into different groups by time of adoption of innovation, we found that income and lifestyle (opinion leadership, novelty seeking tendency and independent decision-making) were variables with measurable impact. Among the managerial variables, price of reception device, contents type, subscription fees were the variables resulting in statistically significant differences. This study, as an attempt to measure the market acceptance for satellite DMB service, a leading next-generation mobile communications service product, stands out from related studies in that it estimates the nature and level of acceptance for specific customer categories, using theories of innovation adoption and diffusion and based on the result of a survey conducted through one-to-one interviews. The authors of this paper believe that the theoretical framework elaborated in this study and its findings can be fruitfully reused in future attempts to predict demand for new mobile communications service products.

지니계수를 통한 농촌어메니티 자원 집중화 연구 (Understanding Distributional Attributes of Rural Amenity Resources using Gini's Coefficient)

  • 이상현;최진용;오윤경;배승종
    • 농촌계획
    • /
    • 제16권2호
    • /
    • pp.57-64
    • /
    • 2010
  • This study aims to understand the degree of inequality of surveyed amenity resources and identify which resource and region have the highest concentration by estimating Lorenz Curve and the Gini's Coefficient. The Lorenz Curve and Gini's Coefficient derived from economics are introduced as tools for investigating and quantifying regional variability of amenity resources concentration. This study describes the concepts underlying the application of the Gini's coefficient to measure the concentration of amenity resources in 11 regions, Chungbuk Province, Korea. The Lorenz Curve presents a graphical view of the cumulative distribution of amenity resources and the Gini's Coefficient provides a single-parameter measure of the distributional concentration of amenity resources. Also the Gini's Coefficient is compared to the number of amenity resource for understanding distributional difference between concentration and quantitative distribution of amenity resources. The results demonstrate significantly different regional variation according to the amenity variables: almost intact nature, interaction between nature and man, man-made.

우리나라 해역별 해양환경에 최적화된 확률모형 개발 (Development of Probabilistic Models Optimized for Korean Marine Environment Varying from Sea to Sea Based on the Three-parameter Weibull Distribution)

  • 조용준
    • 한국해안·해양공학회논문집
    • /
    • 제36권1호
    • /
    • pp.20-36
    • /
    • 2024
  • 요 지 : 본 연구에서는 먼저 우리나라 해역별 해양환경 특성이 담긴 장기 파랑 관측자료로부터 Goda 모형을 활용하여 파력과 양력 시계열자료를 생성하였다. 이어 이렇게 생성된 시계열자료부터 Three-parameter Weibull distribution에 기반한 파력과 양력 확률모형을 개발하였다. 해역별로 다른 우리나라 해양환경은 파력과 양력 확률모형 모수에서도 그 차이를 확연하게 드러내었다. 충분히 발달한 풍성 파가 우월한 남해안의 경우 큰 Scale Coefficient, 작은 Location Coefficient, 1.3 전후의 Shape Coefficient로 특정되는 것을 확인하였다. 이에 비해 파랑의 성장이 취송거리에 의해 제한되는 서해를 마주하고 있는 군산의 경우 작은 Scale Coefficient, 큰 Location Coefficient, 2.0 전후의 Shape Coefficient로 특정되었다. 서해와 남해가 만나는 해역을 마주하고 있는 목포의 경우 작은 Scale Coefficient, 큰 Location Coefficient, 제일 작은 Shape Coefficient를 지녀 남해와 서해의 해양환경이 혼재한다는 사실도 확인할 수 있었다.

Echocardiography Core Laboratory Validation of a Novel Vendor-Independent Web-Based Software for the Assessment of Left Ventricular Global Longitudinal Strain

  • Ernest Spitzer;Benjamin Camacho;Blaz Mrevlje;Hans-Jelle Brandendburg;Claire B. Ren
    • Journal of Cardiovascular Imaging
    • /
    • 제31권3호
    • /
    • pp.135-141
    • /
    • 2023
  • BACKGROUND: Global longitudinal strain (GLS) is an accurate and reproducible parameter of left ventricular (LV) systolic function which has shown meaningful prognostic value. Fast, user-friendly, and accurate tools are required for its widespread implementation. We aim to compare a novel web-based tool with two established algorithms for strain analysis and test its reproducibility. METHODS: Thirty echocardiographic datasets with focused LV acquisitions were analyzed using three different semi-automated endocardial GLS algorithms by two readers. Analyses were repeated by one reader for the purpose of intra-observer variability. CAAS Qardia (Pie Medical Imaging) was compared with 2DCPA and AutoLV (TomTec). RESULTS: Mean GLS values were -15.0 ± 3.5% from Qardia, -15.3 ± 4.0% from 2DCPA, and -15.2 ± 3.8% from AutoLV. Mean GLS between Qardia and 2DCPA were not statistically different (p = 0.359), with a bias of -0.3%, limits of agreement (LOA) of 3.7%, and an intraclass correlation coefficient (ICC) of 0.88. Mean GLS between Qardia and AutoLV were not statistically different (p = 0.637), with a bias of -0.2%, LOA of 3.4%, and an ICC of 0.89. The coefficient of variation (CV) for intra-observer variability was 4.4% for Qardia, 8.4% 2DCPA, and 7.7% AutoLV. The CV for inter-observer variability was 4.5%, 8.1%, and 8.0%, respectively. CONCLUSIONS: In echocardiographic datasets of good image quality analyzed at an independent core laboratory using a standardized annotation method, a novel web-based tool for GLS analysis showed consistent results when compared with two algorithms of an established platform. Moreover, inter- and intra-observer reproducibility results were excellent.

Effect of spatial variability of concrete materials on the uncertain thermodynamic properties of shaft lining structure

  • Wang, Tao;Li, Shuai;Pei, Xiangjun;Yang, Yafan;Zhu, Bin;Zhou, Guoqing
    • Structural Engineering and Mechanics
    • /
    • 제81권2호
    • /
    • pp.205-217
    • /
    • 2022
  • The thermodynamic properties of shaft lining concrete (SLC) are important evidence for the design and construction, and the spatial variability of concrete materials can directly affect the stochastic thermal analysis of the concrete structures. In this work, an array of field experiments of the concrete materials are carried out, and the statistical characteristics of thermophysical parameters of SLC are obtained. The coefficient of variation (COV) and scale of fluctuation (SOF) of uncertain thermophysical parameters are estimated. A three-dimensional (3-D) stochastic thermal model of concrete materials with heat conduction and hydration heat is proposed, and the uncertain thermodynamic properties of SLC are computed by the self-compiled program. Model validation with the experimental and numerical temperatures is also presented. According to the relationship between autocorrelation functions distance (ACD) and SOF for the five theoretical autocorrelation functions (ACFs), the effects of the ACF, COV and ACD of concrete materials on the uncertain thermodynamic properties of SLC are analyzed. The results show that the spatial variability of concrete materials is subsistent. The average temperatures and standard deviation (SD) of inner SLC are the lowest while the outer SLC is the highest. The effects of five 3-D ACFs of concrete materials on uncertain thermodynamic properties of SLC are insignificant. The larger the COV of concrete materials is, the larger the SD of SLC will be. On the contrary, the longer the ACD of concrete materials is, the smaller the SD of SLC will be. The SD of temperature of SLC increases first and then decreases. This study can provide a reliable reference for the thermodynamic properties of SLC considering spatial variability of concrete materials.

계단보행 시 계단 너비가 지면반력 파라미터에 미치는 영향 -비대칭 지수 및 일관성 지수- (The Effect of Stair Depth on Ground Reaction Force Parameters - Asymmetric and Variability Indices -)

  • 윤석훈
    • 한국운동역학회지
    • /
    • 제18권1호
    • /
    • pp.169-178
    • /
    • 2008
  • 본 연구는 계단 보행 중 연속적인 두 스텝의 3차원적 지면반력 파라미터를 제공하고, 계단의 너비에 따른 지면 반력 파라미터의 차이 및 비대칭성과 일관성을 규명하는데 있다. 10명의 성인 대상자가 본 실험에 참여하였으며, 각 10번의 평지, 상향 및 하향보행을 3가지의 다른 너비의 계단에서 실시하였다. 본 연구를 수행한 결과 다음과 같은 결론을 얻었다. 첫째, 계단의 너비는 대부분의 지면반력 파라미터들의 패턴이나 일관성, 비대칭지수에 영향을 미치지 않았다. 둘째, 평지 보행과 계단보행은 지면반력 파라미터의 패턴에서 큰 차이를 보였다. 평지보행과 상향보행은 Fz1, Fz2, 그리고 Fz3로 구성되는 "M" 형태를 보인 반면에 하향보행에서는 Fz2가 거의 없고 큰 Fz1과 작은 Fz3로 구성된 패턴을 보였다. 또한 계단 보행은 평지보행과 매우 다른 전 후 지면반력 패턴을 보였다. 즉 상향보행은 Fy1이 존재하지 않는 패턴을, 하향보행은 Fy2가 존재하나 매우 작은 크기를 보였다. 셋째, 계단보행의 수직 지면반력 파라미터들은 적용가능한 일관성 지수 및 비대칭 지수를 나타내었다.

Morphometric Variations in the Volar Aspect of the Distal Radius

  • Kwon, Bong Cheol;Lee, Joon Kyu;Lee, Suk Yoon;Hwang, Jae Yeun;Seo, Jang-Hyeon
    • Clinics in Orthopedic Surgery
    • /
    • 제10권4호
    • /
    • pp.462-467
    • /
    • 2018
  • Background: Significant discrepancy exists between anatomical plate designs and the anatomy of the native distal radius, which may be attributable to considerable morphometric variations in the volar aspect of the distal radius. We aimed to evaluate the degree of variability in the morphometry of the distal radius and identify factors associated with this variability. Methods: We measured the volar surface angle (VSA) of the intermediate and lateral columns and the volar surface width (VSW) in the distal radius from three-dimensional computed tomography scans acquired from 81 cadaveric forearms. These morphometric parameters were compared between the lateral and intermediate columns, between males and females, and between Koreans and Caucasians. Caucasian morphometric data were obtained and pooled from the previous studies. The coefficient of variation was used to assess the variability of the parameters and Cohen's d to estimate the effect size of the difference between groups. Results: The average VSA of the lateral column was $22^{\circ}{\pm}6^{\circ}$, and that of the intermediate column was $29^{\circ}{\pm}8^{\circ}$ in Koreans (p < 0.001). The variability was high for both VSAs. The VSA of the intermediate column was significantly larger in males than in females (p < 0.001) and in Caucasians than in Koreans (p < 0.001). The average VSW of distal radius was $30{\pm}3mm$ at the watershed line, and it became narrower proximally. The VSW was significantly larger in males than in females (p < 0.001) and in Koreans than in Caucasians (p < 0.001). The effect sizes of the difference for the VSA and VSW between sexes, races and columns were medium to large. Conclusions: Considerable variability exists in the morphometry of the volar distal radius, with sex, race, and column as contributing factors. These results suggest that surgeons should carefully choose an anatomical volar locking plate with appropriate angulation characteristics for each patient to achieve patient-specific alignment of the distal radius.

Reliability and responsiveness of Equivital Lifemonitor and photoplethysmography based wristwatch for the assessment of physiological parameters during a simulated fatigue task

  • Anwer, Shahnawaz;Li, Heng;Umer, Waleed;Antwi-Afari, Maxwell Fordjour;Wong, Arnold YL
    • 국제학술발표논문집
    • /
    • The 8th International Conference on Construction Engineering and Project Management
    • /
    • pp.257-264
    • /
    • 2020
  • Objective: To investigate test-retest reliability and responsiveness of Equivital Lifemonitor and photoplethysmography based wristwatch tools in assessing physiological parameters during a simulated fatigue task. Methods: Ten university students (Mean age, 30.6 ± 1.7 years) participated in this pilot study. Participants were asked to perform a 30-minute of a simulated fatigue task in an experimental setup in a lab. The physiological parameters (e.g., heart rate, heart rate variability, respiratory rate, electrodermal activity, and skin temperature) were measured at baseline and immediately after the fatigue task. An intraclass correlation coefficient (ICC2,1) was used to evaluate the test-retest reliability of each tool in assessing physiological measures. In addition, the responsiveness of each tool to measure changes from baseline to posttest was calculated using a standardized response mean. Results: The Equivital Lifemonitor has shown good to excellent test-retest reliability for the assessment of heart rate (ICC, 0.97), heart rate variability (ICC, 0.86), respiratory rate (ICC, 0.77), and local skin temperature (ICC, 0.76). However, photoplethysmography based wristwatch showed moderate to good test-retest reliability for the assessment of heart rate (ICC, 0.71), heart rate variability (ICC, 0.73), electrodermal activity (ICC, 0.80), and skin temperature (ICC, 0.72). A large standardized response mean (>0.8) indicates that both tools can capture the changes in heart rate, heart rate variability, respiratory rate, skin temperature, and electrodermal activity after a 30-minute of fatigue task. Conclusions: The Equivital Lifemonitor and photoplethysmography based wristwatch devices are reliable in measuring physiological parameters after the fatigue task. Additionally, both devices can capture the fatigue response after a simulated construction task. Future field studies with a larger sample should investigate the sensitivity and validity of these tools in measuring physiological parameters for fatigue assessment at construction sites.

  • PDF