• Title/Summary/Keyword: Testing and Inspection

Search Result 814, Processing Time 0.025 seconds

Improvement of Acid Digestion Method by Microwave for Hazardous Heavy Metal Analysis of Solid Refuse Fuel (고형연료제품의 유해중금속 분석을 위한 마이크로파 산 분해법의 개선)

  • Yang, Won-Seok;Park, Ho-Yeun;Kang, Jun-Gu;Lee, Young-Jin;Lee, Young-Kee;Yoon, Young-Wook;Jeon, Tae-Wan
    • Journal of Korea Society of Waste Management
    • /
    • v.35 no.7
    • /
    • pp.616-626
    • /
    • 2018
  • The quality standards of solid refuse fuel (SRF) define the values for 12 physico-chemical properties, including moisture, lower heating value, and metal compounds, according to Article 20 of the Enforcement Rules of the Act on Resource Saving and Recycling Promotion. These parameters are evaluated via various SRF Quality Test Methods, but problems related to the heavy metal content have been observed in the microwave acid digestion method. Therefore, these methods and their applicability need improvement. In this study, the appropriate testing conditions were derived by varying the parameters of microwave acid digestion, such as microwave power and pre-treatment time. The pre-treatment of SRF as a function of the microwave power revealed an incomplete decomposition of the sample at 600 W, and the heavy metal content analysis was difficult to perform under 9 mL of nitric acid and 3 mL of hydrochloric acid. The experiments with the reference materials under nitric acid at 600 W lasted 30 minutes, and 1,000 W for 20 or 30 minutes were considered optimal conditions. The results confirmed that a mixture of SRF and an acid would take about 20 minutes to reach $180^{\circ}C$, requiring at least 30 minutes of pre-treatment. The accuracy was within 30% of the standard deviation, with a precision of 70 ~ 130% of the heavy metal recovery rate. By applying these conditions to SRF, the results for each condition were not significantly different and the heavy metal standards for As, Pb, Cd, and Cr were satisfied.

A Validation Study on the Drive Ability Cognitive Assessment Tool of Elderly Drivers (고령자 운전능력 인지 검사 도구의 타당화 연구)

  • Cheong, Moon Joo;Lee, Young Mi;Seo, Puluna
    • The Journal of the Korea Contents Association
    • /
    • v.20 no.3
    • /
    • pp.298-308
    • /
    • 2020
  • This study was designed to verify reliability and feasibility by analyzing elderly drivers' ability test tools for older drivers aged 65 or older, which were improved in 2018 and are currently being conducted by the Korea Highway Traffic Authority. Only those aged 65 or older who voluntarily applied to the elderly driving ability evaluation system implemented by the Seoul branch of the Korea Highway Traffic Authority. The research was conducted for about 50 days until Aug. 31, 2018, starting with the registration and inspection of the first study subjects. The analysis performed a correlation analysis with existing tools and cognitive testing tools (MMSE_K) to determine their feasibility and reliability as an improved tool in 2018. As a result, the first, the speed distance, time-space memory, and dispersionism of each sub-component of the old version showed statistically significant static correlation with the sub-factor of the current version. Persistence, on the other hand, was not statistically significant to the current version. The limitations of this study were as follows. Most of the people in the study were highly educated and residents in the metropolitan area. Therefore, it is likely that the results of MSE_K, which checks cognitive and judgment skills, have been upgraded. Also, cognitive tools that are measured by computers are likely to have real measurement errors for generations who are not familiar with computers. Therefore, it is expected that improvement and development of tools for improving the limit points at the site and assessing actual operation capability will be required.

The method of development for enhancing reliability of missile assembly test set (유도탄 점검 장비의 신뢰성 향상을 위한 개발 방법)

  • Koh, Sang-Hoon;Han, Seok-Choo;Lee, Kye-Shin;Lee, You-Sang;Kim, Young-Kuk;Park, Dong-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.8
    • /
    • pp.37-43
    • /
    • 2018
  • A developer solves problems with isolating failures if faults are detected when inspecting missiles using the missile assembly test set (MATS) and then resumes the testing. In order to identify faults, it is necessary to analyze the data coming from the equipment, but the information received may not be sufficient, depending on the inspection environment. In this case, the developer repeats the test until the problem is reproduced or checks the performance of each piece of equipment that is related to the fault. When this task is added, schedule management becomes problematic, and development costs rise. To solve this problem, we need to design a MATS in a systematic way to increase fault coverage while satisfying the required reliability. By designing the necessary processes for each procedure, it is possible to reduce the fault identification time when a fault is detected during operations. But it is not possible to guarantee 100% fault coverage, so we provide another method by comparing costs and effects. This paper describes a development method to enhance the reliability of the missile assembly test set; it describes the expected effects when it is adapted, and describes the limitations of this method.

Prevalence of Abnormal Cervical Cytology in HIV-Negative Women Participating in a Cervical Cancer Screening Program in Calmette Hospital, Cambodia

  • Hav, Monirath;Eav, Sokha;Heang, Nicole;Pich, Pintuna;Lim, Davy;Leang, Vitou;Korn, Aun;Lay, Sanine;Pluot, Michel;Kruy, Leangsim
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.7
    • /
    • pp.3101-3103
    • /
    • 2016
  • Background: According to the most recent estimation of GLOBOCAN, Cambodia has the highest incidence and mortality rate of cervical cancer in Southeast Asia. A screen-and-treat strategy using visual inspection with acetic acid (VIA test) and cryotherapy has been implemented in Cambodia's national cervical cancer screening program since 2013. However, where resources are available, cervical cytology with or without high-risk HPV DNA testing is the preferred screening method used in this country. Aim: This study aims to calculate the prevalence of abnormal cervical cytology and explain the possible factors contributing to a reduced quality of cervical cytology among women participating in a hospital-based cervical cancer screening program in Cambodia. Materials and Methods: A descriptive study was conducted using information from the cytology and pathology database in the Department of Pathology of Calmette Hospital between January 2012 and December 2015. Prevalence of abnormal cervical cytology, based on the Bethesda 2001 classification, was calculated. Data on the adequacy of cytological specimens were analyzed in order to explain the factors contributing to a reduced quality of cervical cytology interpretation. Results: Among 6,207 women who participated in the cervical cancer screening program at Calmette Hospital during 2012 and 2015, 388 (6.25%) had abnormal cytology, which could be classified into Atypical Squamous Cells of Undetermined Significance (92 cases; 1.48%), Atypical Squamous Cells - Cannot Exclude High-Grade Intraepithelial Lesion (13 cases; 0.21%), Atypical Glandular Cells (11 cases; 0.18%), Low-Grade Squamous Intraepithelial Lesion (221 cases; 3.56%), High-Grade Squamous Intraepithelial Lesion (26 cases; 0.42%), and Squamous Cell Carcinoma (25 cases; 0.40%). Unsatisfactory smears made up 12.2% of the total cases. The most frequently identified factor leading to unsatisfactory smears was the absence of cells from the transformation zone. Conclusions: The present study showed an overall prevalence of abnormal cervical cytology of 6.25%, which is comparable to that in many large population-based studies in the Asia Pacific region. Nevertheless, the remarkably high rate of unsatisfactory smears in this study justifies further improvement in specimen sampling among Cambodian gynecologists.

Rheological Behavior of Lyotropilc Solutions of Cellulose in the $NH_3/NH_4SCN$ Solvent System

  • Jo, Jae-Jeong;Cuculo, J.A.;Theil, M.H.
    • Proceedings of the Korean Fiber Society Conference
    • /
    • 1990.06b
    • /
    • pp.36-37
    • /
    • 1990
  • In the past, facile dissolution of cellulose has been hampered by the lack of suitable nondegrading solvents. Recently, this problem has been solved in our laboratory by the discovery of an inexpensive, convenient solvent system, that is the mixture of $NH_3\;and\;NH_4SCN$, for cellulose. Also, the $cellulose/NH_3/NH_4SCN$ solution system has been found to form the anisotropic, i.e., liquid crystalline phase. It is believed that both the cholesterio and the nematic phase occur. This finding has prompted extensive on-going researoh on the formation of the liquid crystalline phase from an inexpensive natural source such as cellulose since the nematic phase is envisioned as an excellent precursor sources for products with desirable properties, for example, high modulus and high strength. This interest naturally leads to a desire to understand the theological properties of the nematic phase so that the transformation of the nematic phase to the solid state with desirable properties can be efficiently accomplished, ;From this point of view, the theological behavior of the $cellulose/NH3_/NH_4SCN$ system has been studied as a function of shear rate and shear stress over a wide range of solvent compositions, cellulose concentration, centrifugation and urea contents, Results indicate that the viscosity decreases with increasing shear rate. A marked shear thinning behavior and a quasi-Newtonian behavior were observed in the low shear rate region and in the high shear rate region, respectively for all solvent compositions. The $cellulose/NH_3/NH_4SCN$ solution system only exhibited the viscosity increase with increasing cellulose concentration and failed to show the viscosity drop generally observed at the point of incipience of liquid crystal formation, This may be due to the gel-like nature of the solution by the association of the rodlike molecules into bundles which may serve as crosslinking points giving the cellulose solution a network structure. Also, simply hydrogen bonding may be so restrictive of molecular mobility that a viscosity drop is blocked. In addition to the above results, yield stress and thixotropy were also observed in the $cellulose/NH_3/NB_4SCN$ solution system which are characteristics of liquid crystal and gel, The results of the effect of centrifugation on viscosity show that viscosity decreases by the application of centrifugation. This may be explained by the change of the piled polydomain structure to the dispersed polydomain structure due to the pressure gradient generated during centrifugation.ation.

  • PDF

Testing and Analysis of Tube Voltage and Tube Current in The Radiation Generator for Mammography (유방촬영용 방사선발생장치의 관전압과 관전류 시험 분석)

  • Jung, Hong-Ryang;Hong, Dong-Hee;Han, Beom-Hui
    • Journal of radiological science and technology
    • /
    • v.37 no.1
    • /
    • pp.1-6
    • /
    • 2014
  • Breast shooting performance management and quality control of the generator is applied to the amount of current IEC(International Electrotechnical Commission) 60601-2-45 tube voltage and tube current are based on standards that were proposed in the analysis of the test results were as follows. Tube voltage according to the value of the standard deviation by year of manufacture from 2001 to 2010 as a 42-3.15 showed the most significant, according to the year of manufacture by tube amperage value of the standard deviation to 6.38 in the pre-2000 showed the most significant, manufactured after 2011 the standard deviation of the devices, the PAE(Percent Average Error) was relatively low. This latest generation device was manufactured in the breast of the tube voltage and tube diagnosed shooting the correct amount of current to maintain the performance that can be seen. The results of this study as the basis for radiography diagnosed breast caused by using the device's performance and maintain quality control, so the current Food and Drug Administration "about the safety of diagnostic radiation generator rule" specified in the test cycle during three years of self-inspection radiation on a radiation generating device ensure safety and performance of the device using a coherent X-ray(constancy) by two ultimately able to keep the radiation dose to the public to reduce the expected effect is expected.

Characterization of Interfacial Adhesion of Cu-Cu Bonding Fabricated by Thermo-Compression Bonding Process (열가압 접합 공정으로 제조된 Cu-Cu 접합의 계면 접합 특성 평가)

  • Kim, Kwang-Seop;Lee, Hee-Jung;Kim, Hee-Yeoun;Kim, Jae-Hyun;Hyun, Seung-Min;Lee, Hak-Joo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.7
    • /
    • pp.929-933
    • /
    • 2010
  • Four-point bending tests were performed to investigate the interfacial adhesion of Cu-Cu bonding fabricated by thermo-compression process for three dimensional packaging. A pair of Cu-coated Si wafers was bonded under a pressure of 15 kN at $350^{\circ}C$ for 1 h, followed by post annealing at $350^{\circ}C$ for 1 h. The bonded wafers were diced into $30\;mm\;{\times}\;3\;mm$ pieces for the test. Each specimen had a $400-{\mu}m$-deep notch along the center. An optical inspection module was installed in the testing apparatus to observe crack initiation at the notch and crack propagation over the weak interface. The tests were performed under a fixed loading speed, and the corresponding load was measured. The measured interfacial adhesion energy of the Cu-to-Cu bonding was $9.75\;J/m^2$, and the delaminated interfaces were analyzed after the test. The surface analysis shows that the delamination occurred in the interface between $SiO_2$ and Ti.

Accurate Quality Control Method of Bone Mineral Density Measurement -Focus on Dual Energy X-ray Absorptiometry- (골밀도 측정의 정확한 정도관리방법 -이중 에너지 방사선 흡수법을 중심으로-)

  • Kim, Ho-Sung;Dong, Kyung-Rae;Ryu, Young-Hwan
    • Journal of radiological science and technology
    • /
    • v.32 no.4
    • /
    • pp.361-370
    • /
    • 2009
  • The image quality management of bone mineral density is the responsibility and duty of radiologists who carry out examinations. However, inaccurate conclusions due to lack of understanding and ignorance regarding the methodology of image quality management can be a fatal error to the patient. Therefore, objective of this paper is to understand proper image quality management and enumerate methods for examiners and patients, thereby ensuring the reliability of bone mineral density exams. The accuracy and precision of bone mineral density measurements must be at the highest level so that actual biological changes can be detected with even slight changes in bone mineral density. Accuracy and precision should be continuously preserved for image quality of machines. Those factors will contribute to ensure the reliability in bone mineral density exams. Proper equipment management or control methods are set with correcting equipment each morning and after image quality management, a phantom, recommended from the manufacturer, is used for ten to twenty-five measurements in search of a mean value with a permissible range of ${\pm}1.5%$ set as standard. There needs to be daily measurement inspections on the phantom or at least inspections three times a week in order to confirm the existence or nonexistence of changes in values in actual bone mineral density. in addition, bone mineral density measurements were evaluated and recorded following the rules of Shewhart control chart. This type of management has to be conducted for the installation and movement of equipment. For the management methods of inspectors, evaluation of the measurement precision was conducted by testing the reproducibility of the exact same figures without any real biological changes occurring during reinspection. Bone mineral density inspection was applied as the measurement method for patients either taking two measurements thirty times or three measurements fifteen times. An important point when taking measurements was after a measurement whether it was the second or third examination, it was required to descend from the table and then reascend. With a 95% confidence level, the precision error produced from the measurement bone mineral figures came to 2.77 times the minimum of the biological bone mineral density change. The value produced can be stated as the least significant change (LSC) and in the case the value is greater, it can be stated as a section of genuine biological change. From the initial inspection to equipment moving and shifter, management must be carried out and continued in order to achieve the effects. The enforcement of proper quality control of radiologists performing bone mineral density inspections which brings about the durability extensions of equipment and accurate results of calculations will help the assurance of reliable inspections.

  • PDF

The analysis of transfer effect through recruit education programs for security personnel (민간 시큐리티 종사자의 신임 교육에 따른 전이효과 분석)

  • Lee, Young-Seok;Bang, Whan-Bog;Choi, Jin-Hyuk
    • Korean Security Journal
    • /
    • no.16
    • /
    • pp.243-264
    • /
    • 2008
  • Investigation about training of Private Security in Korea has managed status of training and understanding of issue mostly, systematic analysis about transfer effect as well as learning and determinant of training is insufficient. Consequently this investigation research to examine the effect of training program for newly appointed private security guards to learning and transfer then, to analyze factor through incumbent private security guard-oriented hypothesis testing under article 13, section 1 of the security guard law. To grasp effect factors of learning and transfer, this dissertation establishes research model and research hypothesis through domestic and foreign studies and then theoretical as well as positive literatures consideration in the first place. Conclusion of this investigation through techniques mentioned above and data analysis is as follows. First of all, the personal characteristics, training characteristics, work environment, difference of transfer as well as learning are verified in accordance with Sociodemographic characterist of Private Security Guard. After then, there is a difference of great import. Secondly, the effect of personal characteristics of Private Security Guard to the transfer is inspected. As a result, there is a difference of significance statistical. Thirdly, the effect of training characteristics of Private Security Guard to the transfer is inspected. Consequently, there is a difference of import statistical. The following thing, subsequent to inspection about the effect of work environment of Private Security Guard to transfer, statistical difference of import is.

  • PDF

Experimental Performance Evaluation of Steel Mesh as Maintenance and Reinforcement Materials (Steel Mesh Cement Mortar의 보수⋅보강 성능 평가)

  • Kim, Yeon-Sang;Choi, Seung-Jai;Kim, Jang-Ho Jay
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.4
    • /
    • pp.50-58
    • /
    • 2014
  • Due to the cost burden of new construction, the necessity of repair and retrofitting of aged structures is sharply increasing as the domain of repair and retrofitting construction is expanding. Because of the necessity, new technologies for repair and retrofitting are continuously studied in Korea and foreign countries. Steel adhesive method, fiber reinforced plastic (FRP) surface adhesive method, and external prestressing method are used to perform the repair and retrofitting works in Korea. In order to consider a repair method using steel mesh reinforced cement mortar (SMCM), 3-point flexural member test was conducted considering repair area and layer number of SMCM. Five types of specimens including ordinary reinforced concrete (RC) specimen with dimensions of $1400{\times}500{\times}200$ (mm) were cast for testing the deflection measurement, a LVDT was installed at the top center of the specimens. Also, a steel strain gauge and a concrete strain gauge were placed at the center of the specimens. A steel strain gauge was also installed on the shear reinforcement. The 3 point flexural member test results showed that the maximum load of SMCM reinforced specimen was higher than that of basic RC specimen in all of the load-displacement curves. Also, the results showed that, when the whole lower part of the basic RC specimen was reinforced, the maximum load and strain were 1.18 and 1.37 times higher than that of the basic RC specimen, respectively. Each specimen showed a slightly different failure behavior where the difference of the results was caused by the difference in the adhesive level between SMCM and RC. Particularly, in SM-B1 specimen, SMCM spalled off during the experiment. This failure behavior showed that the adhesive performance for RC must be improved in order to utilize SMCM as repair and retrofitting material.