• Title/Summary/Keyword: Testing Equipment

Search Result 874, Processing Time 0.031 seconds

A Study on Effectiveness of Application of the IEC 61689 Standard to Ultrasonic Physiotherapy Systems with Frequency Range over 5MHz (5MHz 초과 초음파자극기에 대한 IEC 61689 규격 적용의 유효성에 관한 연구)

  • Youn, Ju-Shin;Choi, Gi Sang
    • Journal of Biomedical Engineering Research
    • /
    • v.36 no.3
    • /
    • pp.69-78
    • /
    • 2015
  • Ultrasonic physiotherapy systems should comply with IEC 60601-2-5(particular requirements for safety of ultrasonic physiotherapy equipment) standard for safety of patients and clinical performances. One of the most important parameters in the standard is the effective radiating area ($A_{ER}$). It has to be measured in accordance with IEC 61689 (field specifications and methods of measurement in the frequency range 0.5MHz to 5MHz). Typical ultrasonic physiotherapy system works in the frequency range 1MHz ~ 3MHz to comply with the IEC 61689. However, ultrasonic physiotherapy system using frequencies over 5MHz is out of the IEC 61689's scope. That is, even if such ultrasonic physiotherapy systems are developed by demands of the market, there is no standard to apply. It is the motivation for this study. Whereas there are other parameters to be considered, this study focuses on the effective radiating area and shows effectiveness of applying IEC 61689 in measuring effective radiating area of ultrasonic physiotherapy systems using frequency range over 5MHz by comparing the results of computer simulation and experiment. Results of this study shows that applying the IEC 61689 standard to ultrasonic physiotherapy system using frequency range over 5MHz is possible.

A User Interface Style Guide for the Cabinet Operator Module (캐비닛운전원모듈을 위한 사용자인터페이스 스타일가이드)

  • Lee, Hyun-Chul;Lee, Dong-Young;Lee, Jung-Woon
    • Proceedings of the KIEE Conference
    • /
    • 2005.05a
    • /
    • pp.203-205
    • /
    • 2005
  • A reactor protection system (RPS) plays the roles of generating the reactor trip signal and the engineered safety features (ESF) actuation signal when the monitored plant processes reach predefined limits. A Korean project group is developing a new digitalized RPS and the Cabinet Operator Module (COM) of the RPS which is used for the RPS integrity testing and monitoring by an equipment operator. A flat panel display (FPD) with a touch screen capability is provided as a main user interface for the RPS operation. To support the RPS COM user interface design, actually the FPD screen design, we developed a user interface style guide because the system designer could not properly deal with the many general human factors design guidelines. To develop the user interface style guide, various design guideline gatherings, a walk-though with a video recorder, guideline selection with respect to user interface design elements, determination of the properties of the design elements, discussion with the system designers, and a conversion of the properties into a screen design were carried out. This paper describes the process in detail and the findings in the course of the style guide development.

  • PDF

Header Data Interpreting S/W Design for MSC(Multi-Spectral Camera) image data

  • Kong Jong-Pil;Heo Haeng-Pal;Kim YoungSun;Park Jong-Euk;Youn Heong-Sik
    • Proceedings of the KSRS Conference
    • /
    • 2004.10a
    • /
    • pp.436-439
    • /
    • 2004
  • Output data streams of the MSC contain flags, Headers and image data according to the established protocols and data formats. Especially the Header added to each data lines contain information of a line sync, a line counter and, ancillary data which consist of ancillary identification bit and one ancillary data byte. This information is used by ground station to calculate the geographic coordinates of the image and get the on-board time and several EOS(Electro-Optical Subsystem) parameters used at the time of imaging. Therefore, the EGSE(Electrical Ground Supporting Equipment) that is used for testing MSC has to have functions of interpreting and displaying this Header information correctly following the protocols. This paper describes the design of the header data processing module which is in EOS­EGSE. This module provides users with various test functions such as header validation, ancillary block validation, line-counter and In-line counter validation checks which allow convenient and fast test on imagery data.

  • PDF

Design of Spent Fuel Rod Slitting Device of an Actual Proof (실증용 사용후핵연료봉 Slitting 장치 설계)

  • Jung J. H.;Yoon J. S.;Hong D. H.;Kim Y. H.;Jin J. H.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2004.05a
    • /
    • pp.109-113
    • /
    • 2004
  • Slitting device is equipment to separate spent fuel of 250 mm rod cut pellets and hull in order to supply required $UO_2$ pellets through the dry pulverizing/mixing device. For development of its device, We have analyzed slitting programs so that the existing device is modified an appropriate scale in the advanced spent fuel conditioning process. The results of the analysis, we added the automatic separation function of pellets and hull, After slitting. Also, we have concentrated on reducing the operation time so that the support and the body of a slitting blade could have been established in the single structure to be easily maintained. It is based on a design and manufacture of a testing device and we have performed an efficiency evaluation. We have analyzed the results of efficiency tests of the slitting device and get the specification of the slitting device. we complete the basic design of the slitting device by using of these data. Therefore, We apply to a basic data when manufacturing a slitting device.

  • PDF

Analysis of Luminance Degradation characteristics of OLED using the Hotplate (핫플레이트를 이용한 OLED의 휘도열화특성 분석)

  • Kim, Yun-Cheol;Lee, Duek-Jung;Jang, Joong-Soon
    • Journal of Applied Reliability
    • /
    • v.16 no.4
    • /
    • pp.356-363
    • /
    • 2016
  • Purpose: The purpose of this study is to propose efficiency of equipment testing the luminance degradation of OLED. Methods: The degradation model of Exponential model and Stretched exponential model is analyzed by goodness of fit test using calculated R-square. The degradation model having the higher R-square is finally selected. Scale parameter and Shape parameter using the selected degradation model is estimated. The activation energy and current density n using peck model among the accelerated model is estimated. the estimated parameters are analyzed by t-test. Results: The results of t-test show that the estimated parameters on chamber and hotplate are equal statistically. we can know the similarity of the luminance degradation rate and degradation pattern on chamber and hotplate. Conclusion: The result of the degradation test on chamber and hotplate is similar. when the accelerated degradation test on the panel of the OLED TV is performed, hotplate is requiring less samples, time and cost than chamber. so the accelerated degradation test on the panel of the OLED TV using the hoplate is efficient of time and cost.

An Efficient Technique to Improve Compression for Low-Power Scan Test Data (저전력 테스트 데이터 압축 개선을 위한 효과적인 기법)

  • Song, Jae-Hoon;Kim, Doo-Young;Kim, Ki-Tae;Park, Sung-Ju
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.43 no.10 s.352
    • /
    • pp.104-110
    • /
    • 2006
  • The huge test data volume, test time and power consumption are major problems in system-on-a-chip testing. To tackle those problems, we propose a new test data compression technique. Initially, don't-cares in a pre-computed test cube set are assigned to reduce the test power consumption, and then, the fully specified low-power test data is transformed to improve compression efficiency by neighboring bit-wise exclusive-or (NB-XOR) scheme. Finally, the transformed test set is compressed to reduce both the test equipment storage requirements and test application time.

Automatic RF Input Power Level Control Methodology for SAR Measurement Validation

  • Kim, Ki-Hwea;Choi, Dong-Geun;Gimm, Yoon-Myoung
    • Journal of electromagnetic engineering and science
    • /
    • v.15 no.3
    • /
    • pp.181-184
    • /
    • 2015
  • Evaluation of radiating radiofrequency fields from hand-held and body-mounted wireless communication devices to human bodies are conducted by measuring the specific absorption rate (SAR). The uncertainty of system validation and probe calibration in SAR measurement depend on the variation of RF power used for the validation and calibration. RF input power for system validation or probe calibration is controlled manually during the test process of the existing systems in the laboratories. Consequently, a long time is required to reach the stable power needed for testing that will cause less uncertainty. The standard uncertainty due to this power drift is typically 2.89%, which can be obtained by applying IEC 62209 in a normal operating condition. The principle of the Automatic Input Power Level Control System (AIPLC), which controls the equipment by a program that maintains a stable input power level, is suggested in this paper. The power drift is reduced to less than ${\pm}1.16dB$ by AIPLC, which reduces the standard uncertainty of power drift to 0.67%.

Monitoring of Methicillin-resistant Staphylococcus aureus in Nasal Swabs Obtained from Dental Clinic Healthcare Providers and Medical Environment Nurses

  • Han, Seung-Ho;Song, In-Sook;Kim, Jong-Koan;Park, Jum-Gi;Park, Jang-Hwan;Lee, Myeong-Jae;Kim, Shin-Moo;Kim, Kang-Ju
    • International Journal of Oral Biology
    • /
    • v.35 no.1
    • /
    • pp.7-12
    • /
    • 2010
  • The aims of this study were to investigate the nosocomial infection route of methicillin-resistant Staphylococcus aureus (MRSA) and explore preventative methods for this pathogen that involve blocking its dispersion. We cultured MRSA from nasal cavity swabs collected between June and July 2008 that we obtained from eight dental healthcare providers, 32 nurses and the sputum specimens of two patients from our hospital. In addition, we used VITEK 2 equipment to measure drug sensitivity, and we further performed biochemical testing and pulse-field gel electrophoresis (PFGE) to isolate MRSA colonies. The incidence of these bacteria on the nasal swabs was 25.0% from dental clinic healthcare providers, 13.6% from the internal medicine ward nurses and 30.0% from intensive care unit nurses. Moreover, MRSA was detectable in sputum specimens of ward patients. The antimicrobial agents resistance and partial PFGE types of MRSA showed a similar pattern. We suggest from these analyses that nasal cavity infection by MRSA could occur by cross contamination between healthcare providers and patients which underscores the importance of stringent MRSA management practices.

A Study of In-hole Method to Measure Dynamic Stiffness of Subsurface Materials (지반의 동적물성치 측정을 위한 인홀시험법에 대한 연구)

  • Mok, Young-Jin;Jung, Jin-Hun;Kim, Young-Su;Jung, Jae-Woo
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2004.03b
    • /
    • pp.261-273
    • /
    • 2004
  • An in-hole seismic method has been developed to meet the requirement of economical testing cost and practicality in engineering practice to measure dynamic soil properties. The in-hole prove developed herein is small and light enough to be fit in three-inch boreholes and to be handled with bare hands. And author modified the existing equipment for the convenient purpose. In addition, the best damper suited to in-hole test was also developed. The performance of the source has been evaluated through extensive cross-hole tests and in-hole tests at various sites.

  • PDF

Design and Impact Testing of Cylindrical Composite-Antenna-Structures having High Mechanical Performanc (기계적 특성이 우수한 원통형 복합재료 안테나의 설계 및 충격 실험)

  • Kim, Dong-Seop;Jo, Sang-Hyeon;Hwang, Un-Bong;Lee, Jung-Hui
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2005.11a
    • /
    • pp.35-38
    • /
    • 2005
  • The Objective of this work was to design Composite Antenna Structures (CAS) and investigate impact behavior of CAS which was various curvature. This term, CAS, indicates that structural surface becomes antenna. Constituent materials were selected considering electrical properties, dielectric constants and tangent loss as well as mechanical properties. For the antenna performance, microstrip antenna layers inserted into structural layers were designed for satellite communication at the resonant frequency of 12.5 GHz and final demonstration article was. After making five kinds of curved CAS, which radii of curvature are flat, 200, 150, 100, 50 mm. The antenna performance changed in accordance with variation of curvature. The Reflection coefficient was independent of curvature but the gain decreased with the radius of curvature. The impact test equipment was Dyna-8250 drop weight tester. The impact characteristic in accordance with curvature is maximum absorb energy is same each other. The impact energy was 8.5 J. For various Impact energy test, five energy levels 3 J, 5 J, 7 J, 10 J, 20 J were used. The performance of impact damaged antenna was estimated by measuring the return loss and the radiation pattern. It was revealed that the performance of antenna was not related to the impact damage. Because the impactor did not damage the patch directly. CAS have good impact stability for the antenna performance.

  • PDF