A Tuning Method for the Power System Stabilizer of a Large Thermal Power Plant and Its Application to Real Power System : PART II - Field Tests and Verification of PSS Performance (대형 화력발전기 전력계통 안정화장치(IEEEST-PSS)의 정수선정 기법과 실계통 적용: PART II - PSS 현장 성능시험 절차 및 성능검증)

  • Shin, Jeong-Hoon;Nam, Su-Chul;Baek, Seung-Mook;Song, Ji-Young;Lee, Jae-Gul;Kim, Tae-Kyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.8
    • /
    • pp.114-121
    • /
    • 2011
  • This paper, as the second part of the paper, dealt with the field test and test results to validate PSS(Power System Stabilizer) parameters which are previously tuned in Part 1 paper. In Part 1 of the paper, the selection of parameters such as lead-lag time constants for phase compensation and system gain was optimized by using linear & eigenvalue analyses and they were verified through the time-domain transient stability analysis. In part 2, the performance of PSS was finally verified by the generator's on-line field test. Through the comparisons of simulation results and measured data before and after tuning of the PSS, the models of generator and its controllers including AVR, Governor and PSS used in the simulation are verified and confirmed.

A Numerical Study on Pressure Variation in a Shock Tube by Changing the Diameter Ratio of Low-Pressure (Driven) to High-Pressure (Driver) Part (충격파관 저압실/고압실 직경비에 따른 압력변동에 대한 수치해석)

  • Wang, YuanGang;Kim, Chul Jin;Sohn, Chae Hoon;Jeung, In-Seuck
    • Journal of the Korean Society of Combustion
    • /
    • v.21 no.4
    • /
    • pp.16-22
    • /
    • 2016
  • Pressure and temperature variations in a shock tube have been studied numerically by changing the diameter ratio of a driven part to a driver part. There are five cases where the adopted diameter ratios are 40%, 50%, 60%, 80%, and 100% respectively. The diameter of the driver part remains unchanged meanwhile the shock tube driven part diameter increases from 40% to 100% of the driver part. In the 100% ratio case, the driver part and driven parts have the same diameter of 66.9 mm. As the diameter ratio decreases, the pressure in the shock tube and available test time are increased.

A Benchmarking Comparison of Rapid Prototyping Processes (쾌속조형(RP)공정 비교분석을 위한 벤치마킹)

  • 김태범;이일랑;정일용;최병욱
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.13-17
    • /
    • 2003
  • Requirements of a benchmarking for rapid prototyping systems and process usually include manufacturing time, cost (including system price), and dimensional accuracy. This paper deals with a benchmarking comparisons to investigate the functional requirements of RP system. A special designed IMS_T2 test part with dimensional. geometrical, and surface roughness features has been used in the inspection of RP processes. IMS_T2 test part was built on 5 commercially available RP machines which are relatively new model in Korea.

  • PDF

Test Pattern Generation for Detection of Sutck-Open Faults in BiCMOS Circuits (BiCMOS 회로의 Stuck-Open 고장 검출을 위한테스트 패턴 생성)

  • Sin, Jae-Hong
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.53 no.1
    • /
    • pp.22-27
    • /
    • 2004
  • BiCMOS circuit consist of CMOS part which constructs logic function, and bipolar part which drives output load. In BiCMOS circuits, transistor stuck-open faults exhibit delay faults in addition to sequential behavior. In this paper, proposes a method for efficiently generating test pattern which detect stuck-open in BiCMOS circuits. In proposed method, BiCMOS circuit is divided into pull-up part and pull-down part, using structural property of BiCMOS circuit, and we generate test pattern using set theory for efficiently detecting faults which occured each divided blocks.

Mechanical Strength Evaluation of A53B Carbon Steel Subjected to High Temperature Hydrogen Attack

  • Kim, Maan-Won;Lee, Joon-Won;Yoon, Kee-Bong;Park, Jai-Hak
    • International Journal of Safety
    • /
    • v.6 no.2
    • /
    • pp.1-7
    • /
    • 2007
  • In this study mechanical strength of A53B carbon steel was analyzed using several types of test specimens directly machined from oil recycling pipe experienced a failure due to hydrogen attack in chemical plants. High temperature hydrogen attack (HTHA) is the damage process of grain boundary facets due to a chemical reaction of carbides with hydrogen, thus forming cavities with high pressure methane gas. Driven by the methane gas pressure, the cavities grow on grain boundaries forming intergranular micro cracks. Microscopic optical examination, tensile test, Charpy impact test, hardness measurement, and small punch (SP) test were performed. Carbon content of the hydrogen attacked specimens was dramatically reduced compared with that of standard specification of A53B. Traces of decarburization and micro-cracks were observed by optical and scanning electron microscopy. Charpy impact energy in hydrogen attacked part of the pipe exhibited very low values due to the decarburization and micro fissure formation by HTHA, on the other hand, data tested from the sound part of the pipe showed high and scattered impact energy. Maximum reaction forces and ductility in SP test were decreased at hydrogen attacked part of the pipe compared with sound part of the pipe. Finite element analyses for SP test were performed to estimate tensile properties for untested part of the pipe in tensile test. And fracture toughness was calculated using an equivalent strain concept with SP test and finite element analysis results.

Analysis of Damaged Instance and Forming Fault for Disc Part in Automotive Steel Wheel (자동차용 스틸휠 디스크부품의 성형불량 및 파손사례분석)

  • Lee, Sung-Hee;Kim, M.Y.;Kim, T.G.;Yun, H.Y.;Kang, S.W.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2006.05a
    • /
    • pp.234-238
    • /
    • 2006
  • In this research, an analysis of damaged instance and forming fault for disc part in automotive steel wheel was performed. Rolled steel material, which had been used in the manufacturing of the damaged disc part, was prepared for tensile test, quantitative analysis of chemical component and acquirement of scanning electron microscope images. Although the results of mechanical properties and chemical component ratio for the material satisfied the suggested specification, some material inherent problem was found in the scanning electron microscope images. Finally, in an analysis of chemical component for the damaged disc part used in road condition, mismatching of chemical component ratio between the suggested specification and test result was found.

  • PDF

Test Pattern Genration for Detection of Stuck-Open and Stuck-On Faults in BiCMOS Circuits (BiCMOS 회로의Stuck-Open 고장과 Stuck-On 고장 검출을 위한 테스트 패턴 생성)

  • 신재흥;임인칠
    • Journal of the Korean Institute of Telematics and Electronics C
    • /
    • v.34C no.1
    • /
    • pp.1-11
    • /
    • 1997
  • A BiCMOS circuit consists of the CMOS part which performs the logic function, and the bipolar part which drives output load. In BiCMOS circuits, transistor stuck-open faults exhibit delay faults in addition to sequential beavior. Also, stuck-on faults enhanced IDDQ (quiscent power supply current) at steady state. In this paper, a method is proposed which efficiently generates test patterns to detect stuck-open faults and stuck-on faults in BiCMOS circuits. The proposed method divides the BiCMOS circuit into pull-up part and pull-down part, and generates test patterns detect faults occured in each part by structural property of the BiCMOS circuit.

  • PDF

IMU calibration technique and laboratory test (관성측정장치의 오차계수 식별기법 및 실험)

  • 성상만;이달호;이장규
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.664-667
    • /
    • 1996
  • This paper presents the error parameter estimation technique for IMU(Inertial Measurement Unit) which is core sensor of INS(Inertial Navigation System) and verifies it via laboratory test. Firstly the error characteristic of gyroscope and accelerometer which is contained in IMU is examined and the error modelling is executed. The error of IMU can be divided into deterministic and random part, and the deterministic error can be divided into static and dynamic part. This paper consider the random part as constant. Secondly the error parameter estimation technique and following procedure for laboratory test is explained. Thirdly according to the test procedure the IMU test for static error is executed using 2-axis rate table and estimation result is presented with discussion about its validity.

  • PDF

Design of Reliability Qualification Test based on Performance Distribution (성능분포에 기초한 신뢰성 인정시험 설계)

  • Kwon, Young-Il
    • Journal of Applied Reliability
    • /
    • v.10 no.1
    • /
    • pp.1-9
    • /
    • 2010
  • In general, the performance of a component degrades as time goes by and failure of a component occurs when the performance degradation reaches a pre-specified level. It is difficult to obtain the failure time distribution data or the necessary number of failure data especially for the metal or machine part. Thus, a design of reliability qualification test based on performance distribution is more effective than failure time distribution. In this study, a performance-based reliability qualification test is developed and a numerical example is provided to illustrate the use of the developed reliability qualification test. This approach could be applied to many kinds of metal or machine part whose magnitude of strength could not be evaluated during at any random points but judgement can be made by only failure of the part. Besides, it is also possible that any parts which have a similar failure characteristics could be applicable to the developed reliability qualification test.

Manufacture and Structural Test of the Small-scaled Composite Hingeless Hub Part for Helicopter (헬리콥터용 축소 복합재료 힌지없는 허브 부품 제작 및 구조 시험)

  • Kim, Deog-Kwan;Hong, Dan-Bi;Kee, Young-Jung;Rhee, Wook;Lee, Myeong-Kyu
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2003.10a
    • /
    • pp.119-122
    • /
    • 2003
  • This report describes the procedure of detailed design and structural test for the composite flexure which is a part of the hingeless hub system. First, stacking sequence design for composite flexure was done, and structural analysis by using NASTRAN was made to verify structural stability and safety. Using FPS installed at KIMM, composite flexure was laid up and cured using a autoclave. Before rotor ground test, the basic structural tests such as a bench test, tensile strength test and shear strength test, for flexure, were accomplished. Through replacing existing metal hub part with new fabricated composite flexure, improvement of aeroelastic stability and weight reduction were achieved. This result will be applied to composite rotor system design fur helicopter.

  • PDF