• Title/Summary/Keyword: Test and evaluation

Search Result 14,930, Processing Time 0.046 seconds

A Study on Test Working of Signalling System (신호시스템 시운전 시험 연구)

  • 정의진;황종규;이종우
    • Proceedings of the KSR Conference
    • /
    • 2000.05a
    • /
    • pp.157-163
    • /
    • 2000
  • Testing evaluation is a part of process for design, production, evaluation, operation and abolition, and is the process of certifying system performance. The main purpose of testing evaluation is to reduce the risk factor under the determining process. Testing process has the three step such as design qualification, integration and validation test in factory, system integration and commissioning test. Design Qualification is to verify errors on the design process. Integration and validation test in factory is for the H/W and S/W of an equipment and is to verify interface of subsystem, communication protocol and main functions. System integration and commissioning test is a functional test to adjust successful installation of equipment. According to the testing process, briefly consideration for test item, test method and test contents about signalling system is carried out.

  • PDF

Reliability Evaluation Criteria and Multi-Stress Aging Test for Polymer Insulator (폴리머 현수애자의 신뢰성 평가 및 복합가속열화 방법)

  • Park, Hoy-Yul;Kang, Dong-Pil;Ahn, Myeong-Sang
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07a
    • /
    • pp.469-472
    • /
    • 2004
  • There have been numerous accelerated aging laboratory tests for evaluating suitability of polymeric materials and devices. Aging test for materials and its full scale device has been conducted, but poor correlation of aging test such as service experience were observed. Service experience plays a key role in the utility section of composite insulators. A meaningful and reliable accelerated aging test is needed for evaluating composite insulator. During the service these insulators are subjected to aging stress such as humidity, pollution, and electrical field, and erosion and tracking of the weathershed occurs. This paper presents the criteria of reliability evaluation and evaluation facilities for 22.9 kV suspension composite insulator. We adopt the criteria of reliability evaluation consist of two test methods. One is CEA tracking wheel test for examining the tracking and erosion performance of composite insulator. The other is multi-stress aging test for examining effects of environmental factors such as UV, temperature, humidity, etc on composite insulator.

  • PDF

A Simulator for Radar Performance Evaluation in a Far-Field Test Range (원방계 조건하에서의 레이다 성능평가를 위한 시뮬레이터)

  • Kil, Min-Young;Myung, Noh-Hoon
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2005.11a
    • /
    • pp.33-38
    • /
    • 2005
  • In this paper, a simulator for radar performance evaluation in a far-field test range is proposed, which can forecast maximum detection range, minimum detection range, number of test trials, resolution (range, azimuth, elevation) with input parameters before radar performance test and process results after. The proposed simulator is designed by Microsoft Foundation Class (MFC) of VC++ 6.0.

  • PDF

Noise Performance Test and Evaluation of a Wind Turbing Generator (풍력발전기 소음 성능 실증)

  • Kim, Seock-Hyun;Kim, Tae-Hyung;Park, Moo-Yeol;Chui, C.C.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.05a
    • /
    • pp.241-245
    • /
    • 2005
  • This study introduces the wind turbine (W/T) noise evaluation procedure required in the international standard (IEC 61400-11) and monitoring system for the evaluation. Noise emission characteristics of a 750kW W/T generator is investigated. Test and evaluation are performed on J48 W/T model which is under operation in Daekwanryung Wind Test Site. With the noise signal, meteorological data and W/T operational data are monitored in real time by the integrated monitoring system using LabVIEW. From the measured noise data, acoustic power level and tonality of the W/T are estimated under the wind speeds required by the international standard.

  • PDF

Performance Evaluation with Protective Function test of Inverter for Solar Power Generation (태양광발전용 인버터 보호기능시험 성능평가)

  • Yoon, Yong-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.11
    • /
    • pp.1570-1575
    • /
    • 2018
  • The increased penetration of PV is impacting on grid operation and in particular the voltage within the local grid can be significantly influenced by the various PV systems. The increased penetration of PV is impacting on grid operation and in particular the voltage within the local grid can be significantly influenced by the various PV systems. This paper describes domestic technical standard of Photovoltaic(PV) PCS(Power Conditioning Systems)- Characteristics of the utility interface. Especially protective function test items of 1) Output overvoltage protection test, 2) Output undervoltage protection test, 3) Frequency rise protection test, 4) Frequency fall protection test, 5) System voltage's momentary interruptions, 6) System voltage distortion capability test. Therefore in this paper protective function test item of facilities evaluation detailed standards for new renewable energy, small, medium and large photovoltaic inverter standard is studied and analyzed and finally full tested by PV inverter performance function.

Toughness Evaluation of Steel Fiber Reinforced Concrete to Spiecimen Types (시편형상에 따른 강섬유보강 콘크리트의 휨인성평가방법)

  • 류종현;김진철;한승환;이상돈;안태송
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.11a
    • /
    • pp.341-344
    • /
    • 2001
  • Fiber reinforced shotcrete(FRS) is widely used in tunnel linings, which strengthen the rock surface and reduce the loosening of the rock strata. The advantages of FRS in tunnel linings are the unsusceptibility to crack, the benefit of shotcrete strength, and the superiority of toughness. In this study, the several evaluation methods of FRS toughness were investgated experimentally, which included the ASTM beam test, EFNARC square panel test and RTA round panel test. Especially, it was examined that the round panel test could fulfill the toughness evaluation of FRS.

  • PDF

Evaluation Technology of Electrical and reliableility Characteristics for Outdoor Polymer Insulator Materials (폴리머 절연물 소재의 전기적 밀 복합열화 특성평가 기술)

  • Ahn, Myeong-Sang;Park, Hoy-Yul;Na, Moon-Kyeong
    • Proceedings of the KIEE Conference
    • /
    • 2006.07c
    • /
    • pp.1343-1344
    • /
    • 2006
  • There have been numerous accelerated aging laboratory tests for evaluating suitability of polymeric materials and devices. Aging test for materials and its full scale device has been conducted. Service experience plays a key role in the utility section of composite insulators. A meaningful and reliable accelerated aging test is needed for evaluating composite insulator. During the service these insulators are subjected to aging stress such as humidity, pollution, and electrical field, and erosion and tracking of the weathershed occurs. This paper presents the criteria of reliability evaluation and evaluation facilities for 22.9 kV suspension composite insulator. We adopt the criteria of reliability evaluation consist of two test methods. One is CEA tracking wheel test for examining the tracking and erosion performance of composite insulator. The other is multi-stress aging test for examining effects of environmental factors such as UV, temperature, humidity, etc on composite insulator.

  • PDF

Air Similarity Test for the Evaluation of Aerodynamic Performance of Steam Turbine (스팀터빈의 공력성능 평가를 위한 공기 상사실험)

  • Lim, Byeung-Jun;Lee, Eun-Seok;Lee, Ik-Hyoung;Kim, Young-Sang;Kwon, Gee-Bum
    • 유체기계공업학회:학술대회논문집
    • /
    • 2003.12a
    • /
    • pp.73-79
    • /
    • 2003
  • The steam turbine efficiency is an important factor in power plant. Accurate evaluation of steam turbine performance is essential. However, it is not easy to evaluate the steam turbine performance due to its high temperature and high pressure circumstance. Therefore most steam turbine performance tests were conducted by air similarity test. This paper described a test program for air similarity test of steam turbine at Korea Aerospace Research Institute. A test facility has been designed and built to evaluate aerodynamic performance of turbines. The test facility consists of air supply system, single stage test section, power absorption system, instrumentation and auxiliary system. For evaluation of steam turbine performance, the test of single stage axial turbine air similarity performance was conducted and uncertainty analysis was performed.

  • PDF

STUDIES ON THE IN VITRO SPF TEST METHOD OF SUNSCREEN PRODUCTS

  • K. H. Son;Kim, Y. O.;Lee, J. P.;S. J. Yang;Kim, W. H.;Kim, C. K.;M. Y. Heo;S. J. Jang;Park, S. S.
    • Proceedings of the SCSK Conference
    • /
    • 2003.09b
    • /
    • pp.528-528
    • /
    • 2003
  • The present study was undertaken to develop the in vitro sun protection factor(SPF) test method having good correlation with in vivo method using human. 8% homomentyl salicylate, P3 reference standard and commercially available sunscreen products were measured by the in vitro method using SPF 290S analyzer, and the SPFs were compared with the SPFs measured by in vivo test method. In vitro SPFs of 8% HMS and P3 reference standard were 4.59 $\pm$ 0.12 and 14.94 $\pm$ 0.83. There are good correspondence, correlation coefficients were 0.9506 and 0.9769 respectively, between the in vitro and in vivo SPFs for the sunscreen creams and lotions. Correlation coefficients of makeup base/liquid foundation, lotion labled with "shake before use" and compact powder were 0.8812, 0.8632 and 0.5984 respectively. The optimum mixture ratio of compact powder and cream base represents 1:0.8. These results suggest that the in vitro SPF test method will be able to be used as an alternative method for in vivo SPF in case of lotion and cream.

  • PDF

Performance Evaluation of Fin-Stabilizer by Model Test and Time-domain Simulation (시뮬레이션과 모형시험을 통한 핀 안정기의 성능평가)

  • 홍사영;김현조;최윤락;신영균;유병석;이승준
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2001.10a
    • /
    • pp.86-90
    • /
    • 2001
  • Demand of good seakeeping perfomace is increasing for sea going vessels such as cruisers, naval ships and container ships. Especillay roll motion is one of major concerns in evaluation of seakeeping performance due to its large resonace motion. Since large roll resonance motion is mainly arised from inherent small damping. use of additional mechnism to provide roll damping can significantly reduce roll motion. In this paper, a reliable performace evaluation method of fin stabilizer, which is very useful for stabilizing roll motion of mid and high speed vessls, is described. Model test and time domain simulation methods are adopted for performance evaluation in which real operating situation of fin stabilizer can be exactly modelled. Model test and simulation results show good correlations between model test and simulation results.

  • PDF