• 제목/요약/키워드: Test Installation

검색결과 1,493건 처리시간 0.029초

A Study on the Measurement of Indoor Air Pollutants in High School Building (교육시설의 공기환경 실측에 관한 연구)

  • Kim, Sun-Jun;Kim, Byoung-Soo
    • Proceedings of the SAREK Conference
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.1392-1397
    • /
    • 2008
  • This study is to measure the change of the $CO_2$ and floating dust concentration depending on the volume of the ventilation and the state of on/off the ventilation for the estimation of the air pollution in classroom. The results could be summarized as follows: the test cell was the two full scaled model and the one is set up with ventilation system another was not. the volume of classroom is 170.1m3 and the number of persons are 35. 1)when the ventilation system was not installed, The experimental results of the $CO_2$ concentration showed the average of 2,150ppm and the maximum of 2,740ppm in the classroom. This was the higher than 1,000ppm, the standard value of ASHRAE and the enforcement regulations of School Sanitation Code in Ministry of Education & Human Resources Development, 1000ppm. The $CO_2$ concentration was relatively increasing during school hours. 3)In case of the volume of ventilation of $800m^3$/h, the $CO_2$ concentration of classroom showed the average of 962 ppm and the maximum of 1,380 ppm. This was higher than 1,000ppm, the standard of ASHRAE and the enforcement regulations of School Sanitation Code in Ministry of Education & Human Resources Development. 4)The floating dust(PM10) was the maximum of 0.52 mg/$m^3$, the minimum of 0.25 mg/$m^3$, and the average of 0.32 mg/$m^3$ in case of the ventilation system off. Those were higher than the standard value 0.15 mg/$m^3$. In case of the ventilation system on, the floating dust(PM10) was the maximum of 0.174 mg/$m^3$ , the minimum of 0.048 mg/$m^3$, and the average of 0.078 mg/$m^3$. These were the lower than 0.15 mg/$m^3$, the standard of the enforcement regulations of School Sanitation Code in Ministry of Education & Human Resources Development. 5)The concentrations of $CO_2$ and PM10 were largely depending on the number of students and the ventilation system, The installation of the ventilation system is necessary for the amenity environment and the management of the indoor air quality.

  • PDF

A Study on Improvement of Modular Specifications - Focused on technical specifying method in waterproof and mechanical works - (모듈러 공사시방서 개선방안에 관한 연구 - 방수 및 기계설비공사의 기술방안 개선을 중심으로 -)

  • Yoon, Jongsik;Shin, Dongwoo;Cha, Heesung;Kim, Kyungrai
    • Korean Journal of Construction Engineering and Management
    • /
    • 제18권3호
    • /
    • pp.33-41
    • /
    • 2017
  • A modular specification is a contract document that specifies the requirements of production, transformation and installation in a modular construction. A problem of the currently used specification is that it does not guarantee the level of performance required by the modular construction and fails to accommodate unique characteristics of each construction because it widely uses the standard specification as it is. This study proposes a specification that reflects the unique feature of modular construction in order to improve the quality of modular construction. Research focuses on the leakage in waterproof and mechanical equipment because it is the area with the highest rate of defects. This study suggests ways to improve the modular specification as follows: 1)Descriptive specifying (following MasterFormat) 2)Propose leakage verification method and test clause 3) Reflect characteristic of modular construction. Proposed modifications to modular specification are reviewed by experts for validation and their opinion verifies suggested improvements as a way to secure the quality of modular construction and to promise characteristics of the modular specification. This improvement will be used for reference when writing construction project specification, which can be an important contract document, so that it could lower occurrence rate of the modular defects.

A Study on the Installation of SCR System for Generator Diesel Engine of Existing Ship (기존 선박의 디젤발전기용 SCR 시스템 설치에 관한 연구)

  • Ryu, Younghyun;Kim, Hongryeol;Cho, Gyubaek;Kim, Hongsuk;Nam, Jeonggil
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제39권4호
    • /
    • pp.412-417
    • /
    • 2015
  • The IMO MEPC has been increasingly strengthening the emission standard for marine environment protection. In particular, nitrogen oxide (NOx) emissions of all ocean-going ships built from 2016 will be required to comply with the Tier-III regulation. In this study, a vanadia based SCR (Selective Catalytic Reduction) system developed for ship application was installed on a diesel engine for power generation of the training ship T/S SAENURI in Mokpo National Maritime University. For the present study, the exhaust pipeline of the generator diesel engine was modified to fit the urea SCR system. This study investigated the NOx reduction performance according to the two kind of injection method of urea solution (40%): Auto mode through the PLC (Programable Logic Control) and Manual mode. We were able to find the ammonia slip conditions when in manual mode method. So, the optimal urea injection quantity can be controlled at each engine load (25, 35, 50%) condition. It was achieved 80% reduction on nitrogen oxide. Furthermore, we found that the NOx reduction performance was better with the load up-down (while down to 25% from 50%) than the load down-up (while up to 50% from 25%) test.

A Study on the Surface Roughness and Initial Stability of Various Dental Implants (수종 임플랜트의 표면 거칠기와 초기안정성에 관한 연구)

  • Cho, Dong-Hoon;Lim, Ju-Hwan
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • 제16권3호
    • /
    • pp.197-210
    • /
    • 2000
  • Surface roughness is one of implant surface topography and it's found that surface roughness characterizations, such as surface energy, oxide layer thickness and its chemical composition, are closely correlated if the roughness is changed. Several studies showed the importance of analyzing surface structure so the surface structure of thread implant was analyzed to measure the implant quality exactly. In this study, surface roughness of 4 implants - MK $II^{(R)}$(Nobel Biocare), $RBM^{(R)}$(Life-Core, USA), $Osseotite^{(R)}$(3i, USA), $TPS^{(R)}$(Life-Core, USA) - were measured using $Accura^{(R)}$ and 40 implants were installed into 4 sets of ten bovine ribs based on the parameters from the measurements. From this test, the following conclusions for the initial stability were drawn by measuring and comparing RFA, Periotest Value (PTV), Removal Torgue Value (RTV). 1. $R_a$ value in surface roughness measurement was increasing by the order of $MKII^{(R)}$, $Osseotite^{(R)}$, $RBM^{(R)}$, $TPS^{(R)}$ and $R_q$ value was the same order. 2. $R_q$ value in each section was observed to increase by the order of $MKII^{(R)}$, $Osseotite^{(R)}$, $RBM^{(R)}$, $TPS^{(R)}$ in top and $MKII^{(R)}$, $RBM^{(R)}$, $Osseotite^{(R)}$, $TPS^{(R)}$ in mid-section but the value of $MKII^{(R)}$ bottom was the lowest, followed by $Osseotite^{(R)}$, $RBM^{(R)}$ and $TPS^{(R)}$. 3. RFA increased by the order of $RBM^{(R)}$(7042Hz), $MKII^{(R)}$(7047Hz), $Osseotite^{(R)}$(7076Hz), $TPS^{(R)}$(7168Hz) and there was no significance between each group. 4. PTV was increasing by the order of $MKII^{(R)}$(-1.62), $TPS^{(R)}$(-1.92), $Osseotite^{(R)}$ & $RBM^{(R)}$(-2.08) and there was no significance, either. 5. Removal torque in RTV measurement showed the increasing order of $MKII^{(R)}(5.31kgf{\cdot}cm)$, $Oeeotite^{(R)}(5.71kgf{\cdot}cm)$, $TPS^{(R)}(5.92kgf{\cdot}cm)$ and $RBM^{(R)}(7.24kgf{\cdot}cm)$ and there was no significance among groups. Above observations explains that surface roughness does not make any impact on the initial stability of implants installation.

  • PDF

A Study on college student's cognition survey about CCTV in education facilities (교육시설내 CCTV에 대한 대학생의 인식조사 연구)

  • Lee, Yong-Whan;Hong, Myoung-Woo
    • Journal of the Korea Society of Computer and Information
    • /
    • 제17권12호
    • /
    • pp.23-30
    • /
    • 2012
  • The purpose of this paper is to analyze various categories such as the recognition, expectation and acceptability of CCTV use in educational facilities by doing a survey on how college students think about the CCTV installed in educational facilities. For this research, diverse existing surveys regarding CCTV were examined, and the appropriate elements of survey questions were extracted and developed. Based on this method, we intend to complete a survey study hereafter on the change in perception regarding CCTV inspection. We made four hypotheses before the survey and the results of the survey are as follows: First, the expectations for CCTV's ability to reduce crime were high. Second, the fears about being a victim of theft or violence crime were decreased. Third, there were a number of respondents who would weigh more on increased safety by installing a CCTV rather than be concerned that CCTV may lead to the violation of students' human rights. Fourth, there showed a difference in recognizing CCTV among three groups. Also, for the questions regarding the places where CCTV is installed, there were many negative opinions on its installation in the student convenient facilities. What we have achieved was not a simple survey which investigates the pros and cons about CCTV use, but a newly suggested way of survey, which enables us to test various hypotheses and figure out the changing perceptions on CCTV effectiveness in educational facilities with more efficiency.

A Cross Sectional Study on Elementary Students' Access to Computer Online Pornography (일개지역 초등학교 고학년들의 컴퓨터 음란물 접촉 실태에 관한 연구)

  • Kim, Chung-Nam;Woo, Hae-Ja
    • Research in Community and Public Health Nursing
    • /
    • 제12권1호
    • /
    • pp.150-167
    • /
    • 2001
  • This cross sectional study was done to find out the situation of computer online pornography access by 4th to 6th grade elementary school students. The subjects of this study were three elementary schools in Andong, which were selected randomly and 120 students randomly selected from 4th to 6th grade for a total of 360 students. The questionnaire was composed with the help of a community health nursing professor and through the reference review. The collected data were analysed by a PC SPSS 10.0 according to school grade and sex, an 12-test was implemented to learn what percent of students have computers and software which prohibit the viewing of online pornography, access motivation and time, content viewed, attitude after accessing the contents, and opinions about computer online pornography. The results of this study were as follows. 1. A total of 86.1% of students had computers at home. Most students placed computers in their own room, 78.9% of students had computer online communication experience. Higher grade students tended to have more experience of communications on the internet (P<0.001). Most students chatted on the internet once or twice a week and higher grade students tended to communicate online more frequently. (P<0.001). Most students used computers more than one hour a day (P<0.05). They used computers according to the following priorities: game, studying, listening to music, communications, chatting. 2. Regarding the frequency of going computer online more than seven times per week, male students showed a higher frequency than female students (P<0.05). Male students used computers more than one hour a day and female students less than half an hour (P<0.001). Male students mostly used computers to play computer games. On the other hand. female students used the computer to study, listen to music, and chat (P<0.001). 3. Regarding software installation to prevent access of computer online pornography, a total of 19.4% of students responded they installed one. but 80.6% didn't have any, 20.3% of students had accessed pornography, 46.6% of students responded. they first get to know to the computer online pornography through friends. 4. The reasons for accessing computer online pornography were ranked as follows: curiosity, interest, to release stress, and sex drive (P<0.05). Obscene contents were found in computer games, pictures, and video. Among these, pictures were the most common. 5. Regarding students' attitude toward online pornography, most students responded that they took much pleasure in the contents (P<0.05). 6. Regarding the question 'Does online pornography degrade morals and cause a sex crime', most students responded as 'no'. They also responded positively to the suggestion that the contents would be effective in preventing sex crimes and to release stress. 74.7% of students responded that males' access of the contents as proper but females' access as immoral. Regarding social efforts to protect students from this harmful environment. most replied that those efforts were unnecessary (P<0.001).

  • PDF

A Study on the Field Application of Epoxy Impregnation Method Using Elastic Storage Tube (탄성저장관을 활용한 에폭시 주입공법의 현장 적용성에 관한 연구)

  • Kim, Chun-Ho;Lee, Ho-Jin;Kim, Kyoung-Min
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • 제22권6호
    • /
    • pp.72-80
    • /
    • 2018
  • In this research, we tried to investigate the influence of concrete on cracks after applying to the actual construction site using the TPS construction method which can be easily charged by the mechanical injection method. To summarize the results, the following It is as follows. First, in the case of ultrasonic velocity, it can be seen that the ultrasonic wave passes rapidly at an average of about 36 mm / sec as compared with the syringe method when using the TPS method, and in the case of the injection depth, the syringe method In the case of TPS construction method, it showed an excellent tendency that 100% of the water retentive material was charged with all the formulations under a strong injection pressure. In the case of compressive strength, it was shown that the average was increased by 16.8% at the time of using the TPS construction method, and it was found to be structurally superior. Taken together, it is possible to confirm the behavior of the crack repairing agent by improving the quality by improving the strength and confirming the window installation by filling the injection material into the closed space at the crack site when using the TPS method compared with the syringe method. In addition, it is expected that construction time will be improved by shortening the construction period of about 5 days for the TPS construction method construction section 532 m, and usability will be expanded by the crack repair method of concrete structure.

In Situ Solute Migration Experiments in Fractured Rock at KURT: Installation of Experimental System and In Situ Solute Migration Experiments (KURT 암반 단열에서 현장 용질이동 실험: 실험 장치 설치 및 현장 용질 이동 실험)

  • Lee, Jae-Kwang;Baik, Min-Hoon;Lee, Tae-Yeop;Park, Kyung-Woo;Jeong, Jongtae
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • 제11권3호
    • /
    • pp.229-243
    • /
    • 2013
  • An in situ solute migration system was designed and installed in KAERI Underground Research Tunnel (KURT) constructed in the site of Korea Atomic Energy Research Institute (KAERI) in order to investigate the migration and retardation of non-sorbing and sorbing tracers through a rock fracture. The system is composed of three main parts including injection, extraction, and data treatment. For the selection of a water-conducting fracture, boreholes were drilled. The fractures in the drilled boreholes were investigated using borehole image analysis using borehole image processing system (BIPS). The results of BIPS analysis showed that borehole YH 3-1 and YH 3-2 were connected each other. Moreover, hydraulic tests were carried out to determine the test section with connectivity for the in situ experiments. The in situ solute migration experiments were accomplished to understand the migration of solutes through fractures in KURT using non-sorbing tracers which were fluorescein sodium, eosin-B, bromide and sorbing tracers which were rubidium, nickel, zirconium, and samarium.

Structural Capacity Evaluation of System Scaffolding using X-Type Advanced Guardrail (교차가새형 선행 안전난간을 적용한 시스템비계의 구조 성능 평가)

  • Park, J.D.;Lee, H.S.;Shin, W.S.;Kwon, Y.J.;Park, S.E.;Yang, S.S.;Jung, K.
    • Journal of the Korean Society of Safety
    • /
    • 제35권5호
    • /
    • pp.49-58
    • /
    • 2020
  • In domestic construction sites, when installing steel pipe scaffolding and system scaffolding, the guardrails are installed after the installation of the work platforms. This conventional guardrail system (CGS) is always exposed to the risk of falls because the safety railing is installed later. In order to prevent fall disasters during erecting and dismantling scaffolds, it is necessary to introduce the advanced guardrail system (AGS) which installs railings in advance of climbing onto a work platform. For the introduction of the AGS, the structural performance of the system scaffolding applying the CGS and the AGS was compared and evaluated. The structural analysis of the system scaffold (height: 31 m and width: 27.4 m) with AGS confirmed that structural safety was ensured because the maximum stress of each element of the system scaffolding satisfies the allowable stress of each element. As a result of performance comparison of CGS and AGS for each element, the combined stress ratio of vertical posts in AGS was 6.4% lower than that of CGS. In addition, in the case of ledger and transom, the combined stress ratios of AGS and CGS were almost the same. The compression test of the assembled system scaffolding (three-storied, 1 bay) showed that the AGS had better performance than the CGS by 9.7% (8.91 kN). The cross bracing exceeds the limit on slenderness ratio of codes for structural steel design. But the safety factor for the compressive load of the cross bracing was evaluated as meeting the design criteria by securing 3 or more. In actual experiments, it was confirmed that brace buckling did not occur even though the overall scaffold was buckled. Therefore, in the case of temporary structures, it was proposed to revise the standards for limiting on slenderness ratio of secondary or auxiliary elements to recommendations. This study can be used as basic data for the introduction of AGS for installing guardrails in advance at domestic construction sites.

Development of State Diagnosis Algorithm for Performance Improvement of PV System (태양광전원의 성능향상을 위한 상태진단 알고리즘 개발)

  • Choi, Sungsik;Kim, Taeyoun;Park, Jaebeom;Kim, Byungki;Rho, Daeseok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • 제15권2호
    • /
    • pp.1036-1043
    • /
    • 2014
  • The installation of PV system to the power distribution system is being increased as one of solutions for environmental pollution and energy crisis. Because the output efficiency of PV system is getting decreased because of the aging phenomenon and several operation obstacles, the technology development of output prediction and state diagnosis of PV modules are required in order to improve operation performance of PV modules. The conventional methods for output prediction by considering various parameters and standard test condition values of PV modules may have difficult and complex computation procedure and also their prediction values may produce large error. To overcome these problems, this paper proposes an optimal prediction algorithm and state diagnosis algorithm of PV modules by using least square methods of linear regression analysis. In addition, this paper presents a state diagnosis evaluation system of PV modules based on the proposed optimal algorithms of PV modules. From the simulation results of proposed evaluation system, it is confirmed that the proposed algorithms is a practical tool for state diagnosis of PV modules.