• Title/Summary/Keyword: Test & Evaluation Method

Search Result 4,787, Processing Time 0.03 seconds

A Study on Noise Certification Evaluation of Hybrid VTOL UAV by Wind Tunnel Test and Flight Test (풍동실험 및 비행시험을 통한 복합형 VTOL 무인기 소음인증 평가에 대한 연구)

  • Ryi, Jaeha;Choi, Jong-Soo
    • Journal of Aerospace System Engineering
    • /
    • v.14 no.spc
    • /
    • pp.39-48
    • /
    • 2020
  • This paper deals with the process of estimating the environmental noise generated from the actual flying aircraft using the noise measurement results obtained through the wind tunnel test and verifying it through flight tests. In order to evaluate the environmental noise of an aircraft, noise tests and evaluations are generally conducted according to the procedures prescribed by the International Civil Aviation Organization (ICAO). In this paper, we introduced environmental noise evaluation method that can be applied to composite both fixed-wing aircraft and multi-copter, and introduced the evaluation method by experiment. This paper introduces the process of simulating the noise test results measured in the wind tunnel test using real flight test results. In addition, in consideration of flight operating conditions and noise measurement methods proposed by the ICAO, the effective perceived noise level (EPNL) was predicted by performing both the wind tunnel test and the aircraft flight test.

Establishment of Dissolution Specifications for Generic Drugs in Korea Pharmaceutical Codex Monograph - Nicametate Citrate Tablet, Norfloxacin Capsule (고시 수재 의약품의 용출규격 설정 - 구연산니카메테이트 정, 노르플록사신 캡슐)

  • Kim, Hee-Yun;Choi, Seon-Hee;Bang, Su-Jin;Han, Kyung-Jin;Choi, Sung-Hee;Baek, Ji-Yun;Kim, Dong-Sup;Kim, Young-Ok;Sohn, Kyung-Hee;Song, Young-Me;Sah, Hong-Kee;Choi, Hoo-Kyun
    • YAKHAK HOEJI
    • /
    • v.54 no.5
    • /
    • pp.362-369
    • /
    • 2010
  • Despite the fact that the dissolution test can serve as an effective tool for drug quality control and prediction of in vivo drug performance, there are a number of drugs with no established dissolution specifications because they were developed quite a long time ago. Under this circumstances, KFDA started the new project that establishes dissolution method and specifications for drugs with no dissolution specifications listed in the Korea Pharmaceutical Codex (KPC). This project aims for promoting the appropriate management of oral solid dosage forms. Seoul regional KFDA selected 2 items, Nicametate citrate tablet and Norfloxacin capsule, for establishing dissolution specifications. We went through the following procedures to develop the dissolution method and specifications: (1) Validation of dissolution test equipment, (2) Purchase of test drugs, (3) Preliminary test with one of the test products (1 lot), (4) Validation of analysis methods (3 lots), (5) Final tests and cross tests among other laboratory to establish dissolution specifications, (6) Additional test with the other test drugs. The outcome of this study will be reflected in revision of the KPC. It is believed that the quality control and evaluation of oral solid dosage forms listed in KPC will be advanced with the revision which adds additional dissolution test and specifications for the drugs with no established dissolution specifications.

Evaluation Environment based on V2X Communication for Commercial Vehicle Cooperative Autonomous Driving (상용차 자율협력주행 플랫폼 평가를 위한 V2X 기반 평가환경 개발)

  • Han-gyun Jung;Seong-keun Jin;Jae-min Kwak
    • Journal of Advanced Navigation Technology
    • /
    • v.25 no.6
    • /
    • pp.450-455
    • /
    • 2021
  • In this paper, we introduce the contents of research on the establishment of an evaluation environment for autonomous cooperative driving platform for commercial vehicles based on V2X communication. For the evaluation of the autonomous cooperative driving platform based on V2X communication, various standards, standards, and guidelines for test evaluation should be developed and provided to the test subject, along with the establishment of test beds such as roads and V2X infrastructure that can apply various driving scenarios. do. In addition, based on this, various reference equipment and test equipment for actual test and evaluation should be developed. In this paper, various technologies, standards, equipment, and construction infrastructure developed to construct the evaluation environment for autonomous cooperative driving platform for commercial vehicles based on V2X communication are introduced.

Stability Evaluation of Shallow Foundation by Plate Bearing Test (PBT에 의한 직접기초의 안정성 평가)

  • Ki Wan-Seo;Joo Seung-Wan;Kim Sun-Hak
    • The Journal of Engineering Geology
    • /
    • v.15 no.4 s.42
    • /
    • pp.423-433
    • /
    • 2005
  • For the design of spread foundation and the stability evaluation, we compared and analyzed it for theoretical, empirical bearing capacity formulas, and various settlement computation formulas, by conducting the plate bearing test at the site of A and B, which consisted of gneiss weathered soil. In addition, we considered the effective method of stability evaluation by carrying out the plate bearing test carried out on the ground consisted of weathering soil of gneiss. Consequently, it was found out that the allowablebearing capacity by the theoretical formula of Terzaghi was too excessive in comparison with the result of the plate bearing test and the Terzaghi-Peck method, which was used widely domestically in designing the spread foundation. It was more effective for a stable design. As a result of the plate bearing test carried out, on the ground consisted of weathering soil. It was found that reviewing the stability by the bearing capacity calculated with load-settlement curve. It is evaluated in a safer side than the point of view of the settlement.

Development of the Dissolution Test for Viquidil Hydrochloride Capsules and Alibendol Tablets (염산비퀴딜 캡슐 및 알리벤돌 정의 용출시험에 관한 연구)

  • Hwang, Joung-Boon;Koo, Eun-Joo;Go, Seu-Youn;Cho, Kyung-Chul;Moon, Hyun-Ju;Cho, Soo-Yeul;Kang, Chan-Soon;Shon, Yeo-Won;Kim, Young-Ok;Sohn, Kyung-Hee;Cho, Dae-Hyun
    • YAKHAK HOEJI
    • /
    • v.54 no.5
    • /
    • pp.348-353
    • /
    • 2010
  • The dissolution test method and an analytical procedure by HPLC were developed and validated for viquidil hydrochloride capsules and alibendol tablets. These drugs were not yet characterized by the dissolution specifications in Korean Pharmaceutical Codex. So, with each reference and test drugs, we did the preliminary and standard experiments based on the Korean Pharmacopeia Guideline of dissolution testing for solid oral dosage forms. The dissolution test for viquidil hydrochloride capsules was carried out under sink conditions as follows: dissolution medium water, paddle rotation speed 50 rpm and vessel volume 900 ml. More than 90% of its label amount was released within 30 min in this method. Also the dissolution test for alibendol tablets was carried out under sink conditions as follows: dissolution medium water, paddle rotation speed 100 rpm and vessel volume 900 ml. More than 90% of its label amount was released within 45 min in this method. The dissolution samples were analyzed with a precise and accurate HPLC method. The developed dissolution test showed specificity, linearity, precision and accuracy within the acceptable range. The dissolution testing method described above was adequate for the purpose and may be proposed as a pharmacopeial standard to assess the performance of viquidil hydrochloride capsules and alibendol tablets.

A Study on the Evaluation of Overconsolidation Ratio of Marine Clay by Flat DMT (DMT를 이용한 해성점토의 과압밀비 추정에 관한 연구)

  • Jeong, Hyeok;Kim, Jong-Kook;Chae, Young-Su;Yoon, Won-Sub
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.03a
    • /
    • pp.979-986
    • /
    • 2008
  • In this study, it enforced DMT test, CPTu test, laboratory consolidation test, because it estimated stress history of Gwangyang port marine clay. Through DMT test obtained Horizontal stress index($K_D$), predicted overconsolidation ratio by $K_D$. To compare empirical equation with laboratory consolidation test and CPTu test calculated OCR examined application. The result, Powell & Uglow(1988) method underestimated OCR value in comparison with Suggestion. Comparatively Byeon wi yong(2004) and Chang(1991) method seem to exactly predict in-situ stress states. Sugawara(1988) method of CPTu test seems to underestimate OCR.

  • PDF

A Comparison Study Between Evaluation Methods on the Rheological Properties of Cement Paste (시멘트 페이스트의 유동 특성에 관한 평가방법 비교연구)

  • Han Cheon-Goo;Lee Gun-Cheol;Heo Young-Sun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.6 no.3 s.21
    • /
    • pp.75-82
    • /
    • 2006
  • This study investigates the influence of various blending factors on cement paste fluidity and find out the most effective evaluation method of cement paste flow, comparing flow test apparatuses such as ring flow(R-F), flow cone(F-C) and mini slump(M-S). A viscometer also measures the rheology coefficients to secure faithful numerical data. Firstly, series I examines cement paste, affected by several cement products and mineral admixture types in the range of W/B 40%, ordinary fluidity, and W/B 30%, high fluidity. In this series, the three types of cement product depended on companies, are randomly used and the mineral admixture, such as fly ash, blast furnace slag and silica fume, are incorporated in the cement paste, in response to the ratio of 10, 20, to 30%, respectively. In addition, series II studies various chemical admixture types, affecting the cement paste. This series is carried out with manufacturing companies and component types in the range of W/C 30%, high fluidity. For the manufacturing companies, randomly four products are used and for the component types, polycaboxylate, melamine, naphthalene and lignosulfonate type are chosen. Test results showed that in the fluidity test of cement paste considering various types of blending factors, R-F exhibited similar tendency with F-C and M-S. In the analysis of consistency curves measured by viscometer, the fluidity evaluation method using flow test apparatuses was significantly effective, except for the some of the low fluidity specimens. In conclusion of this study, R-F was the most convenient, faithful and effective fluidity evaluation method of cement paste.

A Study on the Economic Evaluation of Thermal Spray Methods for the Corrosion Protection of Steel (금속용사 방식공법의 경제성 평가에 관한 연구)

  • Jung Sung-Ho
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2005.05a
    • /
    • pp.13-16
    • /
    • 2005
  • Generally, as corrosive protection processing of a steel structure, zinc galvanizing and heavy duty coating paint are applied. However, zinc galvanizing has the difficulty of restriction of a size, or on-site construction. Moreover, heavy duty coating paint has a problem with many administrative and maintenance expenses with short problem of adhesion, corrosion generating of a damage portion, and maintenance management cycle. In this study, a salt water spray test, CASS test, and the electrochemistry examination were carried out for the thermal metal spray method of construction for corrosive protection performance evaluation. Moreover, the corrosive protection life of a thermal metal spray method of construction was quantitatively calculated on the basis of this experiment. in consideration of LCC, the economical efficiency of a general corrosive protection method of construction and a thermal metal corrosive protection method of construction was compared. Consequently, although initial construction expense was estimated 16 to $30\%$ high, as for a thermal metal spray method of construction, it turns out that the administrative and maintenance expenses for 100 years became cheap 9.3 to 13 or more times.

  • PDF

Dependence Potential of Propofol: Behavioral Pharmacology in Rodents

  • Cha, Hye-Jin;Cha, Ji-Hun;Cho, Hea-Young;Chung, Eun-Yong;Kwon, Kyoung-Jin;Lee, Jun-Yeon;Jeong, Ho-Sang;Kim, Hye-Soo;Chung, Hye-Joo;Kim, Eun-Jung
    • Biomolecules & Therapeutics
    • /
    • v.20 no.2
    • /
    • pp.234-238
    • /
    • 2012
  • Propofol is an anesthetic commonly used to provide sedation or to induce and maintain an anesthetic stated. However, there are reports which indicate propofol may cause psychological dependence or be abused. In the present study, we used various behavioral tests including climbing test, jumping test, conditioned place preference, and self-administration test to assess the dependence potential and abuse liability of propofol compared to a positive control (methamphetamine) or a negative control (saline or intralipid). Among the tests, the conditioned place preference test was conducted with a biased method, and the selfadministration test was performed under a fixed ratio (FR) 1 schedule, 1 h per session. No difference was found in the climbing test and jumping test, but propofol (30 mg/kg, i.p.) increased the rewarding effect in the conditioned place preference test, and it showed a positive reinforcing effect compared to the vehicle. These results indicate that propofol tends to show psychological dependence rather than physical dependence, and it seems not to be related with dopaminergic system.

A Standard Test Methods of Resistance to Root Penetration for Waterproofing and Rootproofing Membrane Using Green Roof System (인공지반녹화용 멤브레인 방수 및 방근재료의 방근성능 평가 방법 제안 연구)

  • Lee, Jung-Hoon;Seon, Yun-Suk;Kwak, Kyu Sung;Oh, Sang-Keu
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2009.11a
    • /
    • pp.141-148
    • /
    • 2009
  • The purpose of this paper is to propose a standard test methods of resistance to root penetration for waterproofing and rootproofing membrane using green roof system. Green roof system is considered to be an important subject in construction industry for green growth project. At the same time, we have to consider the counterplan for protection the damage of waterproofing layer and concrete substrate from the penetration of plant root. But many kinds of materials for protection from root penetration are using in construction field. But the performance of those materials is not clear, and there is not test methods for the evaluation of performance. So in this paper, based on the research results of 4 institutes during four years and foreign cases, we made a standard test methods of resistance to root penetration for waterproofing and rootproofing membrane using green roof system. This test method deals with about environmental condition of laboratory, experimental facilities, kinds of plant, specimen of test, management methods, evaluation duration and documents, etc.

  • PDF