• Title/Summary/Keyword: Temperature Trend

Search Result 1,284, Processing Time 0.027 seconds

The Change of Diurnal Temperature Range in South Korea (우리나라의 일교차 변화에 관한 연구)

  • Heo, In-Hye;Lee, Seung-Ho
    • Journal of the Korean association of regional geographers
    • /
    • v.17 no.2
    • /
    • pp.167-180
    • /
    • 2011
  • This paper investigates the changes of diurnal temperature range (DTR) by season and region in South Korea using daily maximum temperature and daily minimum temperature from 1954 to 2009. It also attempts to find what causes these changes. The daily minimum temperature distinctively increased during the latter half of the research period (1988~2009) than the first half of the year (1954~1987) leading decreases in DTR, while the rise in daily maximum temperature was not distinct during the research period. The DTR shows slightly increasing trend in spring. but decreasing trend in fall. The DTR is decreasing in urban region while it is increasing in rural area. The degree of the DTR decrease is bigger in large urban region than in medium-small urban region. The DTR in urban region is affected by the amount of clouds in spring and tile duration of sunshine in fall. The DTR in rural area is affected by the amount of clouds in spring and the number of days with precipitation in fall.

  • PDF

Numerical Study of CO Reduction Characteristics in High-temperature Air Stream Diluted with Exhaust Gas (배기가스가 혼합된 고온 공기류에서의 CO 소멸특성에 대한 수치해석 연구)

  • Park, Ji-Woong;Oh, Chang Bo
    • Journal of the Korean Society of Combustion
    • /
    • v.20 no.3
    • /
    • pp.8-12
    • /
    • 2015
  • The CO reduction characteristics of hot air stream diluted with exhaust gas in a perfectly stirred reactor (PSR) were investigated numerically. The dilution ratio ($\Omega$), inlet temperature ($T_{in}$), and residence time ($\tau$) were considered as parameters to investigate the effects of those on the emission indices for CO and $CO_2$ (EICO and $EICO_2$). The roles of dominant reactions and the production rates of major species were analyzed. It was found from the EICO trend that the supplied CO in the air stream was consumed. The EICO increased negatively with $T_{in}$ at fixed $\tau$ regardless of $\Omega$. However, the magnitude of EICO and minimum inlet temperature for CO reduction showed complicated trend according to the variation of $\tau$. It was identified that the OH radical, generated from the reactions, $O_2+H{\leftrightarrow}O+OH$ and $2OH{\leftrightarrow}H+H_2O$, affected the CO reduction by the reaction, $CO+OH{\leftrightarrow}H+CO_2$. However, the CO emission ratio increased at sufficiently high inlet temperature range due to the thermal dissociation of $CO_2$.

Experimental Study on Cooling Characteristics of Multi - Air Conditioner using Inverter Scroll Compressor (인버터 스크롤 압축기를 사용한 멀티 에어컨의 냉방 특성에 대한 실험적 연구)

  • 권영철;고국원;진의선;허삼행;전용호;이영덕;박인규
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.4
    • /
    • pp.311-317
    • /
    • 2004
  • In the present study, the cooling characteristics of the multi-air conditioner (A/C) using an inverter scroll compressor are experimentally investigated for the number of the indoor units and the operating conditions (2$0^{\circ}C$, 24$^{\circ}C$, 26$^{\circ}C$) under the cooling standard conditions by KS C 9306. In the case of the simultaneous operation for 3 indoor units, the cooling capacity, the mass flow rate and the input power have a decreasing trend and COP has an increasing trend, with decreasing the difference in the operating temperature of the indoor unit and the room temperature. In the case of the simultaneous operation for 2 indoor units, the COP of the indoor unit with large cooling capacity is high when the operating temperature is high, but the COP of the indoor unit with low cooling capacity is high when the operating temperature is low. In the case of the single operation for one unit, when the large cooling capacity of the indoor unit is less than 50% the compressor operates at the minimum operation frequency region and the COP decreases.

Prediction of electricity consumption in A hotel using ensemble learning with temperature (앙상블 학습과 온도 변수를 이용한 A 호텔의 전력소모량 예측)

  • Kim, Jaehwi;Kim, Jaehee
    • The Korean Journal of Applied Statistics
    • /
    • v.32 no.2
    • /
    • pp.319-330
    • /
    • 2019
  • Forecasting the electricity consumption through analyzing the past electricity consumption a advantageous for energy planing and policy. Machine learning is widely used as a method to predict electricity consumption. Among them, ensemble learning is a method to avoid the overfitting of models and reduce variance to improve prediction accuracy. However, ensemble learning applied to daily data shows the disadvantages of predicting a center value without showing a peak due to the characteristics of ensemble learning. In this study, we overcome the shortcomings of ensemble learning by considering the temperature trend. We compare nine models and propose a model using random forest with the linear trend of temperature.

Long Term Trend of Change In Water Temperature and Salinity in Coastal Waters around Korean Peninsula (한반도 근해 수온 및 염분의 장기변화 추이)

  • Jeong, Hee-Dong;Hwang, Jae-Dong;Jung, Kyu-Kui;Heo, Seung;Sung, Ki-Tach;Go, Woo-Jin;Yang, Jun-Yong;Kim, Sang-Woo
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.9 no.2
    • /
    • pp.59-64
    • /
    • 2003
  • The long­term trend and inter­relationship with depth of temperature and salinity in coastal waters of Korea are studied using coastal oceanographic observation and serial oceanographic data measured by National Fisheries Research and Development Institute. Temperature of coastal waters of Korea except south­western sea of Korea where cold water appears to increase in summer. In case of temperature offshore, surface temperature of East Sea increases, the reverse, for 50m and 100m decreases. Temperature in South Sea of Korea increases in whole depth and for the Yellow Sea, surface temperature increases, but for 50m decreases. In case of salinity offshore, surface salinity of East Sea decreases, but for 50m increases. Surface salinity in South Sea of Korea decreases, the reverse, form 50m and 100m increases. salinity in the Yellow Sea decrease in whole depth According to the result of inter­relationship analysis, for temperature relationship coefficients of 50m and 100m in the East Sea and South Sea of Korea is higher, however, for the Yellow sea the inter­relationship between 50m and 100m is lower. In case of salinity, the inter­relationship between surface and 50m, and for the South Sea of Korea, between 50m and 100m, and for the Yellow Sea, between surface and 50m is higher.

  • PDF

Long-Term Maximum Power Demand Forecasting in Consideration of Dry Bulb Temperature (건구온파를 오인한 장기최대전력수요예측에 관한 연구)

  • 고희석;정재길
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.34 no.10
    • /
    • pp.389-398
    • /
    • 1985
  • Recently maximum power demand of our country has become to be under the great in fluence of electric cooling and air conditioning demand which are sensitive to weather conditions. This paper presents the technique and algorithm to forecast the long-term maximum power demand considering the characteristics of electric power and weather variable. By introducing a weather load model for forecasting long-term maximum power demand with the recent statistic data of power demand, annual maximum power demand is separated into two parts such as the base load component, affected little by weather, and the weather sensitive load component by means of multi-regression analysis method. And we derive the growth trend regression equations of above two components and their individual coefficients, the maximum power demand of each forecasting year can be forecasted with the sum of above two components. In this case we use the coincident dry bulb temperature as the weather variable at the occurence of one-day maximum power demand. As the growth trend regression equation we choose an exponential trend curve for the base load component, and real quadratic curve for the weather sensitive load component. The validity of the forecasting technique and algorithm proposed in this paper is proved by the case study for the present Korean power system.

  • PDF

Change of Temperature using the Twentieth Century Reanalysis Data (20CR) on Antarctica (20세기 재분석 자료(20CR)를 이용한 남극대륙의 기온 변화)

  • Zo, Il-Sung;Jee, Joon-Bum;Lee, Kyu-Tae;Chae, Na-My;Yoon, Young-Jun
    • Ocean and Polar Research
    • /
    • v.34 no.1
    • /
    • pp.73-83
    • /
    • 2012
  • Antarctica is very sensitive to climate change but the number of stations is not sufficient to accurately analyze climate change in this regoin. Model reanalysis data supplements the lack of observation and can be used as long term data to verify climate change. In this study, the 20CR (Twentieth Century Reanalysis) Project data from NCEP/NCAR and monthly mean data (temperature, solar radiation and longwave radiation) from 1871 to 2008, was used to analyze the temperature trend and change in radiation. The 20CR data was used to validate the observation data from Antarctica since 1950 and the correlation coefficients between these data were determined to be over 0.95 at all stations. The temperature increased by approximately $0.23^{\circ}C$/decade during the study period and over $0.20^{\circ}C$/decade over all of the months. This increasing trend was observed throughout the Antarctica and a slight increase was observed in the Antarctic Peninsula. In addition, solar radiation (surface) and longwave radiation (surface and top of atmosphere) trends correlated with the increase in temperature. As a result, outgoing longwave radiation at the surface is attenuated by atmospheric water vapor or clouds and radiation at the top of the atmosphere was reduced. In addition, the absorbed energy in the atmosphere increases the temperature of the atmosphere and surface, and then the heated surface emits more longwave radiation. Eventually these processes are repeated in a positive feedback loop, which results in a continuous rise in temperature.

Effects of Aspergillus oryzae Inclusion on Corn Silage Fermentation

  • Chiou, Peter Wen-Shyg;Ku, Hsiao-Che;Chen, Chao-Ren;Yu, Bi
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.14 no.11
    • /
    • pp.1568-1579
    • /
    • 2001
  • This study is aimed at evaluating the effect of Aspergillus oryzae fermentation extract (AFE) on corn silage fermentation characteristics. Trial included two groups of treatments, with or without AFE inclusion in corn ensilage. Sixty corn silage containers, including two treatments with thirty replicates each, were processed in a laboratory scale mini-silo of 21 cm radius by 45 cm height. Three replicate containers were opened and sampled for analysis at 0, 0.5, 1, 2, 3, 4, 6, 10, 18 and 34 days after being ensiled. One silage container from each treatment was installed with a remote controlled electronic thermometer to record the temperature changes. Analysis included silage temperature, pH, fermentation acids, the water-soluble carbohydrates and chemical compositions and the silage protein fractions. Results showed that on the first day, the temperature of the ensiled corn was slightly higher than room temperature, but returned to room temperature on the second day. The pH and concentrations of WSC, ADF, lignin and acetic acid in the AFE treated silage were significantly lower than the control groups (p<0.05). The lactic acid and crude protein on the other hand were significantly higher in the AFE treated silage as compared to the control (p<0.05) at the end of the ensilage period. The DM content was significantly higher (p<0.05) whereas the butyric acid content of the AFE treated silage was significantly lower (p<0.05) than the control at the end of the 34 day ensilage period. Titratable acid and buffering capacity in the corn silage were not significantly different between treatment groups (p>0.05). Ammonia N concentration in the AFE treated silage showed a trend of decrease (p>0.05). NPN and the protein fraction A in both groups increased during the conservation period, but fraction A in the AFE treated corn silage was significantly higher than the control silage (p<0.05). During the conservation period, the AFE treated corn silage showed a trend toward a decrease in fractions $B_1$, $B_3$ and C (p<0.05). The protein fraction B2 showed a trend toward increase in the control group and an inconsistent trend in the AFE treated silage during the ensiling period. The AFE treated silage showed a better Flieg score over the control silage (97 vs. 75) as calculated from the concentrations of lactic acid, acetic acid and butyric acid.

Analytic Issues for Trend Management on Insulation Diagnositic for High Voltage Motors (고압전동기 절연진단 결과 추이관리의 문제점 분석)

  • Lee, Young-Jun;Ju, Young-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.2052-2053
    • /
    • 2008
  • High voltage motors are the core equipment of electric generation facilities and need to guarantee stable operation. Therefore, keeping healthy state is of importance by means of insulation diagnosis periodically. However, if the diagnosis went through in the different circumstances such as temperature, humidity, and impedance applied to the test equipment, the trend analysis have no significance. This paper presents the experimental results supporting the importance of keeping the same conditions under insulation diagnosis.

  • PDF

An Isothermal Temperature Source with a Large Surface Area using the Metal-Etched Microwick-Inserted Vapor Chamber Heat Spreader

  • Go, Jeong-Sang;Kim, Kyung-Chun
    • Journal of Mechanical Science and Technology
    • /
    • v.18 no.4
    • /
    • pp.681-688
    • /
    • 2004
  • For use of the thermal cycle of the biochemical fluid sample, the isothermal temperature source with a large surface area was designed, fabricated and its thermal characterization was experimentally evaluated. The comprehensive overview of the technology trend on the temperature control devices was detailed. The large surface area isothermal temperature source was realized by using the vapor chamber heat spreader. The cost-effectiveness and simple manufacturing process were achieved by using the metal-etched wick structure. The temperature distribution was quantitatively investigated by using IR temperature imaging system at equivalent temperatures to the PCR thermal cycle. The standard deviation was measured to be within 0.7$^{\circ}C$ for each temperature cycle. This concludes that the presented isothermal temperature source enables no temperature gradient inside bio-sample fluid. Furthermore it can be applied to the cooling of the electronic devices due to its slimness and low thermal spreading resistance.