• Title/Summary/Keyword: Temperature Simulation

Search Result 4,560, Processing Time 0.034 seconds

A Study on Transient Numerical Simulation on Heat Transfer Characteristics in the Resistive SFCL

  • Kim Chul-Ho;Lee Kee-Man;Ryu Kyung-Woo
    • Progress in Superconductivity and Cryogenics
    • /
    • v.7 no.4
    • /
    • pp.14-19
    • /
    • 2005
  • A transient numerical simulation was conducted to have variation of temperature on an element of resistive Superconducting Fault Current Limiter (SFCL) under quench condition. It is very important engineering information for an optimum design of cryogenic system for cooling of a resistive SFCL element. A bifilar coil for resistive SFCL for 10 MVA system was incorporated as a model in this numerical study. From the numerical simulation result, it was found that the averaged temperature on the shunt and Bi-2212 element at 500 kW, 100 ms was 711.1 K and 198.4 K respectively. The temperature variation with the change of the hot-spot size and time is also obtained. The maximum temperature was continuously increased in all cases until the hot-spot stops at 100ms and it was going down after then. Such as, the details of temperature distribution on the SFCL element obtained from this numerical study and it should be very valuable information on the decision of the cooling capacity of cryogenic system.

Effect of Spray Angle of Water Mist Nozzle on Temperature Field of Compartment Fire (물분무노즐의 분사각이 화재실 내부의 온도장에 미치는 영향)

  • Kim, Sung-Chan;Ryou, Hong-Sun;Park, Hyun-Tae;Bang, Ki-Young
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.1703-1708
    • /
    • 2003
  • The present study investigates the effect of injection angle of water mist on fire suppression characteristics by numerical simulation. In order to validate the temperature field by numerical simulation, the predicted results are compared with experimental data. It shows that the temperature difference between measurements and predictions are within $10^{\circ}C$ Numerical simulations of fire suppression are performed for 4 different injection angle($60^{\circ}$, $90^{\circ}$, $120^{\circ}$, and $180^{\circ}$). The grobal mean temperature over the fire compartment decrease with increasing of spray angle. The result shows that the heat transfer between droplets and gas phase are enhaced with the increasing of spray angle. Near the fire source, temperature field by the wide spray angle is slightly higher than that of narrow injection angle because of direct cooling of fire source.

  • PDF

A Numerical Study of the Effect of Casting Temperature and Rotational Frequency of Mold on the Functionally Graded Microstructure in Centrifugal Casting of Hyper-eutectic Al-Si Alloy (과공정 Al-Si합금의 원심주조시 용탕온도와 금형회전수가 경사기능 조직에 미치는 영향에 대한 해석적 고찰)

  • Park, Jeong-Wook;Kim, Heon-Joo
    • Journal of Korea Foundry Society
    • /
    • v.29 no.2
    • /
    • pp.78-85
    • /
    • 2009
  • Functionally graded microstructure of centrifugal cast Al-Si alloy, especially distribution of primary Si particles according to the changes of melt pouring temperature and rotation frequency was investigated by numerical simulation. Moving velocity of Si particles increased as the melt pouring temperature and rotational frequency of mold increased. Therefore, segregation tendency of primary Si particles toward inner side of cylindrical sample increased as the melt pouring temperature and rotational frequency of mold increased. Rich distribution region of particles was located at 0.9, 0.7, 0.4 mm from inner surface of cylindrical sample under the centrifugal cast condition of $750^{\circ}C$ melt pouring temperature and 1500, 2000 and 2500 rpm mold rotational frequencies, respectively, by numerical simulation.

Simulation for Improvement of Temperature Distribution Inside Refrigerator (냉장고 고내 온도산포 개선에 관한 전산모사)

  • Gao, Jia-Chen;Kim, Jae-Yeol
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.18 no.12
    • /
    • pp.98-103
    • /
    • 2019
  • With the increasing need for environmental protection, it is particularly important to improve the energy saving and reliability of refrigerators. Generally, the cold air flowing into the freezer compartment transits to the bottom of the refrigerating compartment, which can lead to uneven temperature distribution. This paper proposes two design solutions for improving the temperature distribution problem. Of these, the optimal refrigeration design was selected and tested using Computational Fluid Dynamics (CFD) modeling and simulation. The results showed improved uniformity of the temperature distribution inside the refrigerator, thus benefitting food storage while reducing energy consumption.

Effect of Spray Angle of Water Mist Nozzle on Temperature Field of Compartment Fire (물분무노즐의 분사각이 화재실 내부의 온도장에 미치는 영향)

  • 김성찬;유홍선;박현태;방기영
    • Journal of the Korean Society of Safety
    • /
    • v.18 no.2
    • /
    • pp.28-33
    • /
    • 2003
  • The present study investigates the effect of injection angle of water mist on fire suppression characteristics by numerical simulation. In order to validate the temperature field by numerical simulation, the predicted results are compared with experimental data. It shows that the temperature difference between measurements and predictions are within $10^{\circ}C$. Numerical simulations of fire suppression are performed for 4 different injection angle($60^{\circ}$, $90^{\circ}$, $^120{\circ}$, and $180^{\circ}$). The global mean temperature over the fire compartment decrease with increasing of spray angle. The result shows that the heat transfer between droplets and gas phase are enhanced with the increasing of spray angle. Near the fire source, temperature field by the wide spray angle is slightly higher than that of narrow injection angle because of direct cooling of fire source.

Phase Transition of Confined Gold Nanoparticles: Replica Exchange Molecular Dynamics Study

  • Kim, Hyun-Sik;Li, Feng-Yin;Jang, Soon-Min
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.3
    • /
    • pp.929-932
    • /
    • 2012
  • The classical molecular dynamics simulation was used to study the phase transition of gold nanoparticles under confinement using Sutton-Chen (SC) potential. Metal gold nanoparticles with different number of atoms are subject to replica exchange molecular dynamics simulation for this purpose. The simulation showing the solidto-liquid melting temperature largely remains unaffected by confinement, while the confinement induces characteristic pre-melting at very low temperature depending on atom number in nanoparticles.

Numerical Simulation of Flow Field and Air Pollutatnts Concentration in Kwangyang Bay (광양만권의 유동장 및 대기오염농도예측)

  • 정용현
    • Journal of Environmental Science International
    • /
    • v.9 no.5
    • /
    • pp.397-402
    • /
    • 2000
  • Numerical simulation model using nesting method and considering topographic features was developed to predict atmospheric environments atmospheric flow temperature and diffusion of air pollutants in Kwangyang bay where having complex areas of point sources Korea. In addition developed simulation model was used tracing of spreading range of pollutants when a gas leaks suddenly from Yeo-cheon industrial complex. by comparing the measured and calculated data on atmospheric flow temperature and diffusion of air pollutants the results showed that this model can be well applied and complicated topography affected the diffusion of air pollutants.

  • PDF

STUDY ON PREDICTION OF THE INDUCED TEMPERATURE IN ENVIRONMENTAL TEST (얇은 평판의 환경시험에서 유도온도 예측에 대한 연구)

  • Lee, J.Y.;Baek, S.H.;Park, S.J.
    • Journal of computational fluids engineering
    • /
    • v.13 no.4
    • /
    • pp.24-32
    • /
    • 2008
  • Environmental test is divided into operation test and storage test. The temperature of storage test is induced temperature which is considered with all sort of the heat source. Induced temperature is the temperature to be adapted to each item and platform and can be induced by computer simulation, laboratory, and real field test. We considered the induced temperature to be associated with solar heat source. In this research. First, we compared the induced temperature which be occurred by one experiment for thin plate in solar test chamber with the other one which be occurred by computer simulation to be SolidWorks 2007 COSMOS FloWorks. After this verification, we showed induced temperature which can be occurred when the test item is stored. Especially, we bring out the induced temperature by applying the ambient temperatures which is presented by MIL-STD-810F and brought out in preceding research.

The Evaluation of the Temperature Characteristics at the Spendrels of Curtain wall with a-Si BIPV Window System (스팬드럴 부분 BIPV창호 적용 및 후면마감재 구성에 따른 온도특성 분석 연구)

  • Kim, Dong-Su;Oh, Myung-Hwan;Yoon, Jongl-Ho
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2012.03a
    • /
    • pp.165-170
    • /
    • 2012
  • This study aims to analyze the characteristics of temperature variation of Spandrels. According to the change of SHGC of Window system, air space, insulation performance and absorption factor of inner surface at the Spandrels, It was firstly estimated by using simulation. Secondly, measured to minimize the temperature-rise of inner surface temperature and the intermediate air temperature by using Full-scale Mock-up based on the result of simulation analysis. As a result, it turns out that low SHGC window system such as BIPV system had an advantage of reducing the window surface temperature, and the surface temperature of clear window system was all higher than BIPV system on simulation results. In the experiment results, it had some advantages of increasing the Spandrels volume, decreasing insulation performance and lower absorption factor.

  • PDF

A Study on the Prediction of Temperature Distribution and Machining Force in the Milling Process (밀링가공에서의 온도분포와 절삭력 예측을 위한 연구)

  • 강재훈;송준엽;박종권
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2004.04a
    • /
    • pp.394-397
    • /
    • 2004
  • This paper presents a simple analytic method using 2D simulation program for predications of cutting force and machining temperature in dry type milling process. And also, comparison of cutting force and machining temperature obtained from experiment and simulation work is accomplished to distinguish of suitability.

  • PDF