• Title/Summary/Keyword: Temperature Setting

Search Result 727, Processing Time 0.03 seconds

An Experimental Study on Applying Heat Pump System to Facility Horticulture House (히트펌프 시스템의 시설원예 적용에 관한 실험적 연구)

  • Kim, Jae-Dol
    • Journal of Power System Engineering
    • /
    • v.17 no.6
    • /
    • pp.88-94
    • /
    • 2013
  • As the results of analysis that are applying a heat pump using underground water as heat source of facility horticulture house, temperature change in house, growth of cultivated plants and the crop characteristic, the conclusion can be acquired as follows. It was possible to maintain the chamber temperature through operating heat pump with setting goal temperature at $16^{\circ}C$ and temperature variation at ${\pm}3^{\circ}C$. And cooling and heating coefficient of performance in heat pump system are different from setting room temperature and operation condition of equipment, totally in case that the setting temperature in house is low, the coefficient of performance and the in case that temperature departure is low. In case that the house does not heated, the result of the growth characteristic of cucumber planted last 50days is that cucumber grown in house equipped with heat pump is the most favorable growth characteristic due to maintaining a constant room temperature. After 90 days, the quantity and weight cucumber harvested in each house are averagely 9.8%, 13.1% increase and more heavy weight respectively. So it is researched that crop characteristic is superior.

The Effect of Aftertreatment Conditions on the Dyeability of PET Filament (Poly(ethylene terephthalate) filament의 후처리 조건이 염색성에 미치는 영향)

  • Lee, Dae-Soo;Han, Myeong-Hee
    • Textile Coloration and Finishing
    • /
    • v.2 no.3
    • /
    • pp.1-7
    • /
    • 1990
  • The crystallinity and dyeability of PET filament were studied when the conditions of drawing and heat-setting were varied. The crystaltinity of PET filament was increased as the drawing ratio and heatsetting temperature were increased. The dye uptake and dyeing rate of PET filament were decreased as the drawing ratio was increased. With increasing the heat-setting temperature, however, the dye uptake and dyeing rate were decreased at an early stage, showing the minimum at $160^{\circ}C-180^{\circ}C$ and then increased above that temperature. The thermal shrinkage of PET filament was decreased as the drawing ratio was increased, while increasing as the heat-setting temperature was increased.

  • PDF

Setting Characteristics of Cement Mortar with Super Retarding Agent Mixing Rate in High Temperature (고온조건에서의 초지연제 혼입율 변화에 따른 모르타르의 응결 특성)

  • Lim, Gun Su;Han, Soo Hwan;Jeong, Yeong Jin;Hyun, Seung Yong;Han, Min Cheol;Han, Cheon Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.05a
    • /
    • pp.131-132
    • /
    • 2021
  • In this study, as part of the study to reduce and integrate heat of hydration of concrete, the performance change of super retarding agent is examined in the mortar area under high temperature conditions. It was confirmed that the setting time delay can be adjusted from several hours to several days depending on the high temperature and the change of super retarding agent mixing rate. With the increase of super retarding agents, the early age strength was delayed while at 28 days the use of super retarding agent results in an increase of strength remakably.

  • PDF

Effect of Storage Conditions on the Setting Properties of Brushite Bone Cement Containing Granular β-Tricalcium Phosphate (과립형 β-삼인산칼슘을 사용한 Brushite계 골시멘트의 보관 조건에 따른 경화 특성)

  • Lee, Sun-Ae;Chung, Tai-Joo;Oh, Kyung-Sik
    • Journal of the Korean Ceramic Society
    • /
    • v.45 no.10
    • /
    • pp.625-630
    • /
    • 2008
  • In the bone cement composed of dense granules of $\beta-Ca_3(PO_4){_2}(\beta-TCP)$ and $Ca(H_2PO_4){_2}H_2O$, the compressive strength, setting time and temperature rise were measured to observe the degradation of cement with respect to the stored days before setting. Decreases of compressive strength and temperature rise were observed, while setting time increased with respect to the stored days. The similar trends were repeated with the increase of temperature of storage. Such a change virtually meant the fading of the character of cement and it took place only when the two starting materials were mixed during storage. The degradation could be mitigated taking advantage of granular $\beta$-TCP instead of powdery one. The formation of $CaHPO_4$, which resulted from reaction with ambient humidity, was attributed to the degradation observed during storage. Dependence of the degradation behavior on mixing and temperature during storage was discussed in terms of the driving force for reaction of cement.

A Study on the Estimation of Heating Energy and CO2 Reduction depending on a Indoor Set Temperature and Clo value (착의량과 실내설정온도 관계에 따른 난방에너지 및 온실가스저감량 평가 연구)

  • Lee, Chul-Sung;Yoon, Jong-Ho
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.4
    • /
    • pp.49-54
    • /
    • 2010
  • Most energy using in building part is mainly consumed for heating and cooling to meet occupancy's comfort temperature. Generally, heating energy consumption show high value than cooling energy in Korea because of high temperature difference in winter season as compared with summer in apartment building. The efforts to develope mechanical performance have been studied to reduce energy consumption in building energy field until now. However, the energy consumption in building is impacted by not only system performance but also PMV particularly at temperature and Clo value. This means that energy consumption can be changed by occupancy's comfort setting temperature in apartment building. This study investigated the passibility of overheating in apartment building by occupant' slow Clo and its setting temperature from preceding research and then the heating energy consumption by setting temperature was calculated with ESP-r. The effects of heating energy and $CO_2$ reduction are also evaluated quantitatively with Clo value. The results showed that keeping ISO-7730 standards can reduce heating energy up to 21% in compared with option 2; also, wearing underclothes with ISO-7730 standard can considerably reduce heating energy consumption up to 50%. As compared with option 2, the reduction of $CO_2$ emission for option 3 showed 0.63TCO2 of kerosene, 0.49TCO2 of LNG and 1.09TCO2 of electricity. The option 4 can be reduced by 1.48TCO2 of kerosene, 1.16TCO2 of LNG and 2.57TCO2 of electricity respectively.

Estimation of the Setting Time of the Super Retarding Concrete Combining Mineral Admixtures (혼화재를 조합 사용한 초지연 콘크리트의 응결시간 추정)

  • Han, Min-Cheol
    • Journal of the Korea Institute of Building Construction
    • /
    • v.8 no.3
    • /
    • pp.111-117
    • /
    • 2008
  • This study provides the setting time prediction method of super retarding concrete incorporating mineral admixtures at the same time including fly ash(FA), blast furnace slag(BS) based on maturity method. The setting time was retarded, as super retarding agent contents increase and curing temperature decreases. In addition, apparent activation energy by Arrhenius function was ranged from $24{\sim}35KJ/mol$ with slightly difference along with mixture proportion. This value is smaller than existing value $30{\sim}50KJ/mol$. It is Indicated that equivalent age using setting time can be a proper method to predict setting time and it also exhibited comparable relativity between prediction value and measurement value. Therefore, this study provided setting time prediction value with super retarding agent contents and mineral admixture combination. Setting time prediction equation provided herein is possibly valid for estimating precise setting time of the super retarding concrete at the job site.

Dyeing Properties of CDP fiber( II ) - Effect of Heat Setting on Dyeing and Physical Properties of CDP Fabric - (CDP 섬유의 염색성(II) - 염색성 및 물성에 미치는 열처리의 영향 -)

  • Shin Woo Young;Jeong Dong Seok;Lee Mun Cheul
    • Textile Coloration and Finishing
    • /
    • v.17 no.3 s.82
    • /
    • pp.8-15
    • /
    • 2005
  • Cationic dyeable polyester(CDP) fabric was annealed at varying temperatures range from $120^{\circ}C$ to $220^{\circ}C$ for 1, 3, and 5 min under tension. Dyeing rates of CDP fabrics were measured with cationic and disperse dyes at $100^{\circ}C$ and $120^{\circ}C$ in water system. Also X-ray diffraction pattern, DSC thermograms and dyeability of fabric with cationic and disperse dyes were investigated. The intensities of X-ray diffraction peaks of annealed fabric were increased with increasing in annealed temperature, and peak became sharp with heat setting temperature. The apparent color depth (K/S) of CDP fabric initially decreased with increase of heat-setting temperature up to $160\~180^{\circ}C$ and then increased at higher temperature. The shearing modulus(G) and surface roughness were increased with annealing temperature.

Investigation on the Applicability for Method of Setting Time Difference by Super Retarding Agent for Reducing Hydration Heat of Transfer Girder Mass Concrete (전이보 매스콘크리트의 수화열저감을 위한 초지연제 응결시간차 공법의 적용가능성에 대한 검토)

  • Yoon Seob;Hwang Yin Seong;Baik Byung Hoon;Han Cheon Goo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.05a
    • /
    • pp.128-131
    • /
    • 2004
  • This paper is to investigate the mock up test results of mass concrete for transfer girder using setting time difference with super retarding agent(SRA) to reduce hydration heat. According to test results, the temperature history of plain concrete without placing lift had a steep rising curvature, and plain concrete had a big temperature difference between surface and middle section of mass concrete, which may result in occurrence of temperature crack. However, considering placing method B, because setting time of middle section concrete was retarded with an increase in SRA contents, higher hydration heat temperature was observed at surface section concrete compared with that at middle section concrete at early age, which can lower the possibility of hydration heat crack. In case of placing method C, although peak temperature of hydration heat was much lower, at early age, high crack occurrence possibility of the hydration heat attributable to the big temperature difference between middle section and bottom section of concrete was expected at bottom section concrete. Therefore, the structure above the ground like transfer girder is not applicable to consider the placing method C.

  • PDF

Effect of temperature on the rheological properties of dental interocclusal recording materials

  • Pae, Ahran;Lee, Ho-Rim;Kim, Hyeong-Seob
    • Korea-Australia Rheology Journal
    • /
    • v.20 no.4
    • /
    • pp.221-226
    • /
    • 2008
  • The purpose of this study was to compare rheological properties of six dental interocclusal recording materials and to investigate the effect of temperature on the rheological properties during setting. Five polyvinylsiloxane materials and one polyether material were investigated in this study. The storage modulus (G') and the loss factor ($tan{\delta}$) were measured from 30s after mixing during setting, using the universal dynamic spectrometer. Viscoelastic properties were evaluated by means of G' and $tan{\delta}$ from 5 repeats at $21^{\circ}C$ and $33^{\circ}C$. Individual changes during setting were also evaluated. All data were statistically analyzed using one-way ANOVA and multiple comparison $Scheff{\acute{e}}$ test at the significance level of 0.05. The mean of G was checked at $t_{set}$ (the setting time provided from manufacturer) and $t_{300}$ (the end of experimental time) and the mean of $tan{\delta}$ was checked at to and $t_{set}$. Whereas the increase of the G' value showed generally exponential changes at $21^{\circ}C$, the change of the G' value at $33^{\circ}C$ displayed sigmoidal curves during setting. The change of loss factor $tan{\delta}$ during setting varied. Within the limitations of this study, dental interocclusal recording materials had different viscoelastic properties and most of the materials showed different fluidity at $21^{\circ}C$ and $33^{\circ}C$.

Analysis of Early-age Property of JPCP Slab of Incheon International Airport (인천국제공항 줄눈콘크리트 슬래브의 초기재령 특성분석)

  • Sun, Ren Juan;Jeong, Jin-Hoon;Cheon, Sung-Han;Lim, Jin-Sun
    • 한국방재학회:학술대회논문집
    • /
    • 2007.02a
    • /
    • pp.335-339
    • /
    • 2007
  • A jointed plain concrete pavement(JPCP) slab was tested in Incheon International Airport construction work to study the early-age property of JPCP slab. The temperature and moisture data of the concrete slab had been collected and analyzed. The setting time of the concrete was decided by using the maturity method. The initial setting time is 2 hours 40 minutes after the placement of the slab. The investigation and analysis of the slab began from the initial setting time. The strains of different locations and different depths of the slab show different variation character.

  • PDF