An Experimental Study on Applying Heat Pump System to Facility Horticulture House

히트펌프 시스템의 시설원예 적용에 관한 실험적 연구

  • Kim, Jae-Dol (Department of Refrigeration and Air Conditioning Engineering, TongMyong University)
  • 김재돌 (동명대학교 냉동공조공학과)
  • Received : 2013.07.22
  • Accepted : 2013.09.13
  • Published : 2013.12.31

Abstract

As the results of analysis that are applying a heat pump using underground water as heat source of facility horticulture house, temperature change in house, growth of cultivated plants and the crop characteristic, the conclusion can be acquired as follows. It was possible to maintain the chamber temperature through operating heat pump with setting goal temperature at $16^{\circ}C$ and temperature variation at ${\pm}3^{\circ}C$. And cooling and heating coefficient of performance in heat pump system are different from setting room temperature and operation condition of equipment, totally in case that the setting temperature in house is low, the coefficient of performance and the in case that temperature departure is low. In case that the house does not heated, the result of the growth characteristic of cucumber planted last 50days is that cucumber grown in house equipped with heat pump is the most favorable growth characteristic due to maintaining a constant room temperature. After 90 days, the quantity and weight cucumber harvested in each house are averagely 9.8%, 13.1% increase and more heavy weight respectively. So it is researched that crop characteristic is superior.

Keywords

References

  1. Y. M. Lee, 2007, "The views of economics in the protected horticulture agriculture", KSCS & KBS symposium, pp. 41-67.
  2. S. Ueda and Kyau, 1989, "Heat pumps of protected horticulture", Refrigeration, Vol. 64, No. 735, pp. 27-34.
  3. Y. C. Yoon and W. M. Seo, 1997, "Function and system of heat pump in the protected horticulture", KSAE, Vol. 39, No. 4, pp 5-13.
  4. Y. C. Yoon, W. M. Seo and S. G. Lee, 2005, "The study of performance of heat pump for heating greenhouse", KSAE, Vol. 40, No. 3, pp. 94-102.
  5. T. H. Huh, 2012, "On the Application of the Heat Pump System to Facility Horticulture Using Hot Waste Water from Power Plants", Thesis of Graduate School, Jeju University, pp. 6-50.