The Journal of the Convergence on Culture Technology
/
v.4
no.4
/
pp.419-427
/
2018
This paper designs and develops auto-tuning temperature controller with multi-channel, which controller with multi-channel could control a number of control system simultaneously. This controller has multi-channel input and output. And a number of control algorithms run in this controller simultaneously and independently. Firstly we present design method of controller with multi-channel. Secondly we design electrical circuit of sensor input, controller output and power control for temperature control board. And finally we design data protocol for serial communication to monitor control state and present verification of temperature controller with muiti-channel through field experiment.
Chung-Kwang Lee;Young-Kyu Hong;Jin-Wook Kim;Sung-Chul Kim;Jinhee Kim
Korean Journal of Agricultural Science
/
v.49
no.2
/
pp.331-339
/
2022
Deforestation and conservation of coniferous forest have been recognized as critical issues in Korea due to climate change. The main purpose of this research was to monitor changes of secondary metabolite contents and growth of Korean fir (Abies koreana) according to the temperature change in Mt. Halla. The Korean fir located at three different regions, Yeongsil, Witseoreum, and Jindallaebat, was monitored in April, July, and October from 2016 to 2018 and secondary metabolites, specifically lutein, α-carotenoid, and β-carotenoid, were analysed with high performance liquid chromatography. The results showed that average concentrations of lutein, α-carotenoid, and β-carotenoid were 0.82 - 23.30, 0.02 - 2.01, and 0.11 - 2.84 ㎍·g-1 and the highest concentration of secondary metabolite was observed in October compared to April and July. The average length and width of Korean fir in the three regions were 11.84 - 20.70 and 1.78 - 2.41 mm from 2016 - 2018. A correlation analysis showed that the concentrations of all three secondary metabolites were negatively correlated with temperature and a significant difference was observed between temperature and lutein concentration in Korean fir. Overall, growth and production of secondary metabolites in Korean fir highly depended on the temperature, and global warming thus might have an adverse effect on the growth and physiological changes of Korean fir in Mt. Halla.
Journal of the Korean Society for Nondestructive Testing
/
v.9
no.1
/
pp.77-82
/
1989
DC potential drop(DCPD) measurement system was made and the optimum measuring conditions have been studied. The room temperature resistivity of commercially available medium carbon steel(S45C) was measured using this technique. DCPD was measured in the specimens which were hardened and tempered at different temperatures. It was found that DCPD reflected the change of the microstructure during tempering very sensitively. It was possible to monitor the stage of tempering of S45C steel nondestructively using DCPD measurement.
Proceedings of the Korean Society of Precision Engineering Conference
/
2004.10a
/
pp.73-77
/
2004
This paper presents a PC-based controller of industrial SFFS(Solid Freeform Fabrication System). The SFFS has multiple sub-controllers for the building room, the powder room, the temperature, and the density of oxygen in the chambers. Hence the main PC-based controller should effectively and timely send commands to the sub-controllers, and monitor the overall SLS process. The required actuators and sensors are selected to optimize the overall performance of the SFFS.
In this paper, image processing technologies was employed to monitor and visualize the conditions of the inside of furnace for glass. In order to capture the images of the furnace under the high temperature environment, specially designed camera system was used. From the experimental results we see that the developed software showed good information about the inside conditions such as a scum line and positions of bubbles.
This paper proposes the strain-insensitive temperature sensing in quasi-distributed sensor system using different thermal expension coefficient materials. This system has the high sensitivity and hasn't the necessity of reference signal. We can monitor the condition of the power cable with this system.
In this paper we are trying to explain the effect of temperature on polymer membrane exchange water electrolysis (PEMWE) and polymer membrane exchange fuel cell (PEMFC) simultaneously. A comprehensive studying approach is proposed and applied to a 50Watt PEM fuel cell system in the laboratory. The monitoring process is carried out through wireless LoRa node and gateway network concept. In this experiment, temperature sensor measure the temperature level of electrolyzer, fuel cell stack and $H_2$ storage tank and transmitted the measured value of data to the management control unit (MCU) through the individual node and gateway of each PEMWE and PEMFC. In MCU we can monitor the temperature and its effect on the performance of the fuel cell system and control it to keep the lower heating value to increase the efficiency of the fuel cell system. And we also proposed a mathematical model and operation algorithm for PEMWE and PEMFC. In this model, PEMWE gives higher efficiency at lower heating level where as PEMFC gives higher efficiency at higher heating value. In order to increase the performance of the fuel cell system, we are going to monitor, communicate and control the temperature and pressure of PEMWE and PEMFC by installing these systems in a building of university which is located in the southern part of Korea.
This paper proposes a new temperature control algorithm and system configuration of the pTMS(personal Thermal Massage System). By controlling the pulse width of the PWM(Pulse Width Modulation), the temparature of the heating lamp can be controlled stably, which is indispensable to the massage function. This technology is also adapted to the 'thermal massage', 'thermal acupressure', 'thermal moxibustion' functions of medical equipments. The temperature could be set at between $40^{\circ}C{\sim}70^{\circ}C$ by increments of $5^{\circ}C$, the control could be made in real time by increments of $1^{\circ}C$, and the temperature is displayed on the monitor by triggering every 2 seconds. when the present temperature is equal to the preset temperature, the PWM signal is minimized, and when the present temperature is higher than the preset temperature, overheating is prevented by interrupting the PWM output signal. When the difference of temperature exceeds $4^{\circ}C$, the PWM control is maximized in order for the system to reach the target temperature within a short period of time.
Jang, Jin Cheol;Lee, Min Ho;Lee, Jun Yeop;Choi, Hee Chul;Choi, Dong Yun;Kim, Hyeok Ju;Kim, Hyeon Tae
Journal of Biosystems Engineering
/
v.40
no.4
/
pp.368-372
/
2015
Purpose: The purpose of this study is to verify the feasibility of using an infrared sensor to measure the body temperature of a sow. We first conducted experiments on three pigs by using three infrared sensors and one indoor temperature sensor. Methods: The three infrared sensors were installed inside our model house and were used to take temperature measurements per second of the backs of the pigs. While feeding, the temperatures of the backs of the pigs were measured at distances of 10 cm, 20 cm, and 30 cm from the infrared sensors. Results: We concluded that the relation between the temperature of the pigs' backs and the indoor temperature was y =0.549x + 18.459 at a measuring distance of 30 cm. The relation was y = 0.645x + 15.461 for a distance of 20 cm and y = 0.760x + 11.913 for a distance of 10 cm. We found high correlation between the indoor temperature and the temperature of the pigs' backs. Conclusions: It is possible to use an infrared thermometer to monitor the temperature of pigs' backs. This system seems to be feasible and effective in monitoring pig temperature. The use of an infrared thermometer will also make daily monitoring easy. In later experiments, the possibility of developing a system that can determine if an error can be corrected by using infrared sensor is explored by considering humidity variables.
Journal of the Korea Academia-Industrial cooperation Society
/
v.19
no.11
/
pp.536-540
/
2018
As the performance of engines improves, the temperature of engines is increasing, resulting in a high piston temperature. An excessively high piston temperature may result in torque drop or engine failure. An oil jet is used to reduce the piston temperature. In this study, to monitor the effect of oil jet, a templug was used to measure the piston temperature. A templug is a kind of sensor and the hardness of the templug changes according to the piston temperature. Using a templug, the maximum temperature of the piston was measured with and without an oil jet. The piston temperature was lowered using the oil jet. The highest temperature region changed from the center crown to the front/rear area. In addition, the temperature difference between the highest and lowest regions became smaller.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.