• Title/Summary/Keyword: Telescopic abutment

Search Result 15, Processing Time 0.018 seconds

Use of polyaryletherketone (PAEK) based polymer for implant-supported telescopic overdenture: A case report

  • Park, Chan;Jun, Dae-Jeon;Park, Sang-Won;Lim, Hyun-Pil
    • The Journal of Advanced Prosthodontics
    • /
    • v.9 no.1
    • /
    • pp.74-76
    • /
    • 2017
  • Although many prosthetic materials exist for fabrication of implant-supported telescopic overdentures, available materials have not been thoroughly evaluated from a functional standpoint. This case report describes the use of polyaryletherketone (PAEK) based polymer for an implant-supported telescopic overdenture, a seldom used material in dentistry. This material is lighter than traditional materials, can accommodate changes in retentive forces, and is an easily retrievable by CAD/CAM fabrication. This case highlights the possibility of using new polymer materials for implant-supported telescopic overdentures.

A STUDY ON THE STRESS DISTRIBUTION OF ABUTMENT TEETH AND RESIDUAL RIDGE AREA BETWEEN TELESCOPIC AND CLASP TYPE RPD BY FEM METHOD (telescope형 및 Clasp형 유지장치를 이용한 국소의치 지지조직의 응력분포에 관한 삼차원 유한요소법적 연구)

  • Koak, Jai-Young;Kim, Kwang-Nam;Chang, Ik-Tae;Heo, Seong-Joo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.37 no.1
    • /
    • pp.104-126
    • /
    • 1999
  • The purpose of this study was to compare and evaluate the stress distribution and displacement developed in the abutment teeth and residual ridge area by madibular unilateral distal extension removable partial denture with 2 different retainer designs. The retainers on right and left canine and right 2nd molar were Alters clasp in one model and telescopic crown in the other model. The stress distribution of abutment teeth and residual ridge area on two model were compared and analyzed with 3-dimensional finite element method. 150N and 400N forces were applied vertically, 30 degree and horizontally on the central fossa area of left 1st molar of the removable partial denture, and then stress distribution patterns were analyzed and compared. The results were as follows 1. As the magnitude and angulation of applied force were increased, the magnitude of stress on the right and central residual ridge area and the right canine of the telescopic type increased and comparing to those of the Alters clasp type. 2. As the magnitude and angulation of applied force were increased, the mesial direction of displacement on the right residual ridge area and the right tooth of the telescopic type increased and the distal direction of displacement on left residual ridge area and the left canine increased comparing to those of Akers clasp type. 3. As the vertical force was applied, the distal direction of the displacement of the right tooth were greater and that of the left canine was smaller and the upward displacement of the right canine was greater in telescopic partial denture than those of Akers clasp type. 4. As the 30 degree force was applied, the mesial direction of the displacement of the right tooth were greater and the distal direction of the displacement of the left canine was smaller and the upward displacement of the right canine was greater in telescopic partial denture than those of Akers clasp type. In the horizontal force the results were same in right area tooth but the distal direction of displacement was greater in left canine. 5. In both removable partial dentures, as the magnitude and degree of force were increased, the stress and displacement were increased. The compressive force was dominative than the ten sile force. 6. In both removable partial dentures, the magnitude of stress was greater on mucosal tissue area than that of the alveolar bone area on distal extension residual ridge area but the result was reversed on anterior residual ridge area. The displacement was always greater on mucosal tissue area than that of alveolar bone area.

  • PDF

A PHOTOELASTIC STRESS ANALYSIS ON TOOTH SUPPORTING STRUCTURE AND RESIDUAL RIDGE ACCORDING TO DENTURE DESIGN FOR REMAINING MANDIBULAR CANINES (하악 견치 잔존시 의치 설계에 따른 치아 지지조직 및 잔존치조제의 광탄성 응력분석)

  • Kim, Il-Pyung;Koh, Joon-Won;Jin, Tai-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.35 no.3
    • /
    • pp.486-503
    • /
    • 1997
  • The purpose of this study was to evaluate the stress patterns developed in abutment and residual ridge according to removable denture design in case of remaining mandibular canines. The removable denture designs in this study were as foolows : 1. Removable partial denture with non-splinted abutment 2. Removable partial denture with splinted abutment 3. Overdenture with telescopic crown 4. Overdenture with O-Ring attachment 5. Overdenture with combination bar attachment Photoelastic stress analysis was used to record the isochromatic fringe patterns and to calculate principal stress components at measuring points. The results were as follows : 1. In case of removable partial denture with non-splinted abutment, stress of root area at the loaded side was the largest. No significant differences in stress of root area were observed between loaded side and unloaded side. 2. No significant differences in stress of residual ridge at the loaded side were observed between removable partial denture with splinted abutment and removable partial denture with non-splinted abutment. 3. In case of combination bar attachment retained overdenture, stress of root area was the largest and in case of telescopic crown retained overdenture, stress of root area was the lowest. 4. In case of attachment retained overdenture, stress of residual ridge was lower but stress of root area was larger than in case of removable partial denture.

  • PDF

Stress Analysis of Abutment and Supporting Tissues by Changing Angles and Heights of Konus Telescope Inner Crown (Konus Telescopic Denture의 내관 각도 및 높이에 따른 지대치 및 지지조직의 응력 분석)

  • Vang, Mong-Sook;Gettleman, Lawrence
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.19 no.3
    • /
    • pp.139-151
    • /
    • 2003
  • This study was to evaluate and to compare the compressive strength and the displacement effecting the abutment or the residual ridge which are transformed by the angle and the heights of the konus denture inner crown when restorating the unilateral konus denture by using the mandibular canine and the 1st premolar as an abutment. The author made 9 different models for different inner crown heights and konus angles. The inner crown height were divided to 5mm, 6mm, and 7mm and konus angles was divided to $4^{\circ}$, $6^{\circ}$, and $8^{\circ}$. And then in each model, 5kg of $15^{\circ}$ mesial load was stressed on the central fossa of the 1st premolar and the 1st molar. The stresses and displacement were measured using the finite element analysis. The results were as follows 1. The maximum compressive strength was shown on the connective area of the abutment and the denture base. 2. As the angle of the inner crown becomes increased, the compressive strength was shown smaller. 3. As the height of the inner crown becomes increased, the maximum compressive strength was shown smaller while the compressive strength of the root apex and the residual ridge showed larger. 4. When the stress was loaded only on the 1st premolar, the more compressive strength was concentrated on the root apex area of the 1st premolar. 5. When the stress was loaded only on the 1st premolar, the compressive strength was concentrated uniformly on the abutment and the residual ridge. 6. When the stress was loaded only on the 1st molar, the maximum displacement was shown on the distal part of the residual ridge.

Literature review and case report of prosthetic rehabilitation with telescopic denture (이중관 의치에 관한 문헌 고찰 및 증례 보고)

  • Sung, Han-Gyul;Jo, Eun-Hye;Ko, Kyung-Ho;Huh, Yoon-Hyuk;Park, Chan-Jin;Cho, Lee-Ra
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.56 no.4
    • /
    • pp.308-316
    • /
    • 2018
  • Telescopic denture has advantages such as transfer the occlusal force to the long axis of the abutment, easiness of oral hygiene management, increase of retention and stability, splint effect due to secondary fixation between abutments and have been reported a higher success rates than conventional removable partial denture (RPD). However, there are disadvantages such as complex laboratory procedures, long treatment periods and high costs, and high incidence of complications. This clinical report describes two cases, a 4-point supported telescopic denture using telescopic crown and a 2-point supported telescopic denture using conical crown with functionally satisfactory results. Frequent complications of telescopic denture, which are reported in various literature were reviewed. Clinical and laboratory procedures were performed in consideration of complications that reported.

Prosthetic treatment for patient with anterior overbite and partial edentulism using maxillary hybrid telescopic double crown RPD and mandibular fixed prostheses: A 11-yr follow-up (전치부 과개교합을 가진 상하악 부분 무치악 환자에서의 상악 하이브리드 텔레스코픽 이중관 국소의치와 하악 고정성 보철물을 이용한 치료의 11년 경과관찰 증례)

  • Choi, Hyunsuk;Cho, Jin-Hyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.4
    • /
    • pp.415-421
    • /
    • 2021
  • The biomechanical prognosis of conventional removable partial denture is questionable in case of patient with few remaining teeth or periodontally compromised teeth. In this case, hybrid telescopic double crown RPD may be a successful treatment alternative. Hybrid telescopic double crown RPD has following advantages over conventional RPD: secondary splinting effect between abutments, more vertical stress direction and more convenient in repairing the denture after extraction of abutment tooth. In this clinical case, patient had deep overbite in anteriors and partially edentulous. The maxilla was restored with hybrid telescopic double crown RPD and the mandible was restored with implants and fixed prostheses. Long-term follow-up and supportive periodontal treatment were performed, and satisfactory results were achieved in terms of function and aesthetics.

STRESS ANALYSIS AT SUPPORTING TISSUE OF ABUTMENT TEETH AND RESIDUAL RIDGE ACCORDING TO DENTURE DESIGN WITH REMAINING UNILATERAL POSTERIOR TEETH (편측 후방 치아 잔존시 의치 설계에 따른 지대치지지 조직과 잔존 치조제의 응력 분석에 관한 연구)

  • Ahn, Kwang-Ho;Jung, Young-Wan;Jin, Tai-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.37 no.2
    • /
    • pp.185-199
    • /
    • 1999
  • This study was peformed to investigate the distribution and magnitude of stress at supporting tissue of abutment teeth and residual ridge tissue with remaining unilateral posterior teeth. Four types of removable partial dentures that included clasp retained removable partial denture, attachment retained removable partial denture, telescopic removable partial denture, and swing-lock partial denture were designed, and strain gauge was used for stress analysis. Each prosthesis was subjected to simulated vertical and oblique load. The following conclusions were drawn from this study. 1. The clasp retained removable partial denture generally distributed simulated vertical force more evenly to the supporting structure. 2. The stress at buccal side of 1st premolar was the lowest in swing-lock partial denture and that was highest in attchment retained removable partial denture. The stress at lingual side of 1st premolar was the lowest in telescopic partial denture. 3. In clasp retained removable partial denture, stress was lower at load site and ridge crest at mid-line, but it was higher at 1st premolar area on vertical load. 4. In attachment removable partial denture, stresses at buccal side of 1st premolar. lingual side of 1st premolar on vertical load, and ridge crest at midline on oblique load were higher. 5. In telescopic removable partial denture, stress at lingual side of 1st premolar was the least in all removable partial dentures, but the stress at load site was higher. 6. In swing-lock removable partial denture, stress at buccal side of 1st premolar was the lowest, and stresses at load site and distal end of residual ridge crest were higher.

  • PDF

A clinical report of hybrid telescopic double crown denture with friction pin in a failed double crown denture case (실패한 이중관 국소의치에서 하이브리드 텔레스코픽 이중관 국소의치를 이용한 임상증례)

  • Park, Jong-Hoon;Cho, Jin-Hyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.2
    • /
    • pp.201-209
    • /
    • 2021
  • In removable partial dentures, many types of retentive systems have been studied and applied in clinical treatment. One of those systems is the double crown denture system which is widely used in European countries such as Germany and Sweden. Telescopic double crown dentures have several advantages such as convenience in maintaining oral hygiene, enabling to transfer occlusal force along the long axis of the abutment, and secondary splinting effect between the abutments which leads to higher clinical performance compared to conventional removal partial dentures. In this clinical case, the patient was initially restored with a maxillary hybrid telescopic double crown denture with friction pin using remaining natural teeth as abutments. After 7 years, due to lack of recall check-up and poor oral hygiene, the abutment teeth were affected by periodontitis and 4 out of 5 of the abutment teeth had to be extracted. 3 additional implants were placed and the original abutment tooth with the inner crown was maintained. The mandible had fixed prostheses including implants but nevertheless, with strategic implant placement, the patient adapted well and was satisfied with the new maxillary tooth-implant combined double crown denture.

Clinical outcomes of rigid and non-rigid telescopic double-crown-retained removable dental prostheses: An analytical review

  • Seo, Jeong-Gyo;Cho, Jin-Hyun
    • The Journal of Advanced Prosthodontics
    • /
    • v.12 no.1
    • /
    • pp.38-48
    • /
    • 2020
  • PURPOSE. The objective of this literature review was to analyze the cumulative survival rates (CSRs) of rigid and non-rigid double-crown-retained removable dental prostheses. MATERIALS AND METHODS. Screening of the literature published from January 1995 to December 2019 was performed by using electronic data base (Pubmed) and manual search. The CSRs of rigid and non-rigid double crown removable dental prostheses were investigated. RESULTS. A total of 403 articles were reviewed and 56 relevant articles of them were selected. Subsequently, 25 articles were included for data extraction. These articles were classified according to rigid and non-rigid type double crowns and further subdivided into teeth, implants, and teeth-implant combination types. The CSRs of rigid type double crown ranged from 68.9% to 95.1% of 5 to 10 years in tooth abutments, 94.02% to 100% over a 3-year mean observation periods in implant abutments, and 81.8% to 97.6% in tooth-implant combination. Non-rigid type double crowns had various CSR ranges from 34% to 94% maximum during 10 years observation in teeth abutment. The CSRs of non-rigid type had over 98% in implant abutments, and ranged from 85% to 100% in tooth-implant combination. CONCLUSION. The CSRs of double crowns varies according to types. With accurate evaluation of the remaining teeth and plan of the strategic implant placement, it could be successful treatment alternatives for partially or completely edentulous patients.

Causes of failures of long-term used double crown denture and new rehabilitation with dental implant and tooth combined denture using remaining teeth and implants (장기간 사용한 이중관 의치의 실패원인 및 자연치와 임플란트를 이용한 이중관 의치 수복증례)

  • Seo, Jeong-Gyo;Cho, Jin-Hyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.56 no.4
    • /
    • pp.384-390
    • /
    • 2018
  • Hybrid telescopic double crown have ever been good treatment option for patient with periodontally unfavorable few remaining teeth for successful prognosis. Tooth and implant combined telescopic double crown can be used for improving retention and support for denture with strategically placed implants on edentulous ridge. In this case, an 55-year-old female patient had chronic periodontitis with few remaining teeth on maxilla and fixed partial prosthodontics on mandible. Treatment of hybrid telescopic double crown with friction pin lasted 9.5 years only with natural teeth. After 9.5 years, additional implants was installed due to fracture of cast-posted abutment teeth. After implantation, tooth and implant combined double crown had fabricated. Through re-treatment, no complications of new denture has been found during 2 years follow up. This case presents fair prognosis of tooth and implant combined double crown denture in periodontally unfavorable condition.