Abstract

Although many prosthetic materials exist for fabrication of implant-supported telescopic overdentures, available materials have not been thoroughly evaluated from a functional standpoint. This case report describes the use of polyaryletherketone (PAEK) based polymer for an implant-supported telescopic overdenture, a seldom used material in dentistry. This material is lighter than traditional materials, can accommodate changes in retentive forces, and is an easily retrievable by CAD/CAM fabrication. This case highlights the possibility of using new polymer materials for implant-supported telescopic overdentures.

Keywords

References

  1. Zarb GA, Hobkirk J, Eckert S, Jacob R. Prosthodontic treatment for edentulous patients: complete dentures and implantsupported prostheses. 12th ed. St. Louis: Elsevier; 2004.
  2. Zarb GA, Schmitt A. The edentulous predicament. II: The longitudinal effectiveness of implant-supported overdentures. J Am Dent Assoc 1996;127:66-72. https://doi.org/10.14219/jada.archive.1996.0032
  3. Passia N, Ghazal M, Kern M. Long-term retention behaviour of resin matrix attachment systems for overdentures. J Mech Behav Biomed Mater 2016;57:88-94. https://doi.org/10.1016/j.jmbbm.2015.11.038
  4. Fuhrmann G, Steiner M, Freitag-Wolf S, Kern M. Resin bonding to three types of polyaryletherketones (PAEKs)-durability and influence of surface conditioning. Dent Mater 2014;30:357-63. https://doi.org/10.1016/j.dental.2013.12.008

Cited by

  1. 상악 무치악 환자에서 가공 지르코니아 바와 PEKK 슬리브를 이용한 임플란트 피개의치 증례 vol.33, pp.4, 2017, https://doi.org/10.14368/jdras.2017.33.4.307
  2. 심한 치조골 소실이 있는 상악 무치악 환자에서 Pekkton telescopic attachment를 이용한 임플란트 피개의치 증례 vol.57, pp.2, 2017, https://doi.org/10.4047/jkap.2019.57.2.189
  3. Investigation of the retention forces of secondary telescopic crowns made from Pekkton® ivory in combination with primary crowns made from four different dental alloys: an in vitro stud vol.64, pp.5, 2017, https://doi.org/10.1515/bmt-2018-0167
  4. Investigation of the retention forces of secondary telescopic crowns made from Pekkton® ivory in combination with primary crowns made from four different dental alloys: an in vitro stud vol.64, pp.5, 2017, https://doi.org/10.1515/bmt-2018-0167
  5. Comparison of various 3D printed and milled PAEK materials: Effect of printing direction and artificial aging on Martens parameters vol.36, pp.2, 2017, https://doi.org/10.1016/j.dental.2019.11.017
  6. Parameters Affecting the Retention Force of CAD/CAM Telescopic Crowns: A Focused Review of In Vitro Studies vol.10, pp.19, 2017, https://doi.org/10.3390/jcm10194429