• Title/Summary/Keyword: Teeth wear

Search Result 172, Processing Time 0.023 seconds

Full Mouth Rehabilitation in Severely Worn Dentition (심한 교모증 환자의 완전 구강 회복)

  • Jung, Jae-Hyun;Choi, Min-Ho;Park, Young-Rok;Kim, Chang-Heon;Kang, Dong-Wan
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.19 no.3
    • /
    • pp.247-256
    • /
    • 2003
  • The patient had bruxism and epilepsy tendency. Inadequate or unstable posterior support was identified due to severe anterior attrition and decreased occlusal vertical dimension. Prematurities of posterior occlusal and wear facets increased the function of anterior teeth, resulting in severe wear. Wear facets displayed sharply defined peripheries, which are matched on articulated diagnostic casts. Also the patient showed C III malocclusion tendency, and lost some facial contour with drooping corners on the mouth. In this case, the alteration of OVD (Occlusal Vertical Dimention) may provide a biologically compatible adjunct to the treatment such as dentofacial esthetics, improved visual proportion in facial heightand mechanical solutions to the force-management of the masticatory system. The patient requires extensive restorative treatment to regain appropriate function, esthetics and comfort. According to the report by Farhad Fays, the average vertical distance from the maxillary to the mandibular mucolabial reflection in the region of the central incisors is approximately 34mm. However, the vertical distance of this patient was found to be 32mm, which was necessary to add gauge 20-sheets to apply vertical dimension. A removable occlusal overlay splint, which restores OVD to the estimated optimalposition, is the general first trial. The patient was observed periodically for 6 weeks, while appropriate adjustments were made vertical dimension to function. When patient felt comfortable with the splint, the teeth were prepared, and provisional restorations are placed for 3 months. The provisional restoration was fabricated by a diagnostic wax-up. When the patient felt comfortable with the provisional restoration, the final restoration mimics OVD, function, and esthetics that have been developed in the treatment restorations. Restoration of the extremely worn dentition presents a substantial challenge to thedentists. Therefore, careful evaluation of the etiology, history, and factors associated with occlusal vertical dimension should be preceded prior to the appropriate treatment planning.

Full mouth rehabilitation of a patient with tooth wear and insufficient restorative space due to loss of posterior teeth support: a case report (구치부 지지 상실로 인해 치아 마모와 부족한 수복 공간을 보이는 환자에서의 완전구강회복 증례)

  • Hyunsub Kim;Young-Jun Lim;Ho-Beom Kwon;Myung-Joo Kim
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.62 no.1
    • /
    • pp.72-81
    • /
    • 2024
  • To rehabilitate a patient with inappropriate occlusion due to posterior support loss, it is necessary to achieve an appropriate occlusal vertical dimension and create prostheses that demonstrate stable occlusion at the centric relation for full mouth restoration. This case shows full mouth rehabilitation in a patient with missing posterior teeth and tooth wear, achieved through implant-supported prostheses and zirconia full-veneer crowns. To assess adaptation to the increased occlusal vertical dimension, an occlusal splint and temporary restorations were secured. By fabricating the definitive restorations based on the anterior guidance of the temporary restorations, stable occlusal rehabilitation was successfully achieved.

A case of direct restore using 4-META/MMA-TBB resin containing organic filler in patients with severe occlusal surface wear and enamel fracture (심한 교합면 마모 및 교두 파절 환자에서 유기필러를 함유한 4-META/MMA-TBB 레진을 활용한 직접수복 증례)

  • Dae-Sik Kim;Gyeong-Je Lee
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.39 no.4
    • /
    • pp.222-228
    • /
    • 2023
  • Attrition is the loss of tooth hard tissue due to contact between teeth, and in severe cases, dentin is exposed, accompanied by selective corrosion and excessive wear of teeth, which is called cupping. If these lesions are left untreated, the size of the lesion gradually increases, breaking the unsupported enamel, resulting in a decrease in aesthetics and chewing function. In this case report, patients with cupping and enamel fracture due to severe attrition were directly restored using a resin with soft properties containing organic fillers. In the follow-up observation six years later, most of the filling of the occlusal surface was eliminated, but the filling on the buccal surfaces remained relatively intact, and it was confirmed that this type of resin was suitable for the area where the occlusal force was relatively weak rather than the area where the occlusal force was greatly applied.

In vitro evaluation of a removable partial denture framework using multi-directionally forged titanium

  • Suzuki, Ginga;Shimizu, Satoshi;Torii, Mana;Tokue, Ai;Ying, Guo;Yoshinari, Masao;Hoshi, Noriyuki;Kimoto, Katsuhiko;Miura, Hiromi;Hayakawa, Tohru;Ohkubo, Chikahiro
    • The Journal of Advanced Prosthodontics
    • /
    • v.12 no.6
    • /
    • pp.369-375
    • /
    • 2020
  • PURPOSE. This study evaluated the availability of multi-directionally forged (MDF) titanium (Ti) as a component of removable partial dentures (RPDs). MDF-Ti remarkably improved the mechanical properties of RPDs due to its ultrafine-grained structure. MATERIALS AND METHODS. The wear resistance, plaque adhesion, and machinability of MDF-Ti were tested. As controls, commercially pure (CP) titanium was used for wear, plaque adhesion, and machinability tests. For wear resistance, the volume losses of the titanium teeth before and after wear tests were evaluated. Plaque adhesion was evaluated by the assay of Streptococcus mutans. In the machinability test, samples were cut and ground by a steel fissure bur and carborundum (SiC) point. An unpaired t-test was employed for the analysis of the significant differences between MDF-Ti and the control in the results for each test. RESULTS. Wear resistance and plaque adherence of MDF-Ti similar to those of CP-Ti (P>.05) were indicated. MDF-Ti exhibited significantly larger volume loss than CP-Ti in all conditions except 100/30,000 g/rpm in machinability tests (P<.05). CONCLUSION. Although the wear resistance and plaque adherence of MDF-Ti were comparable to those of controls, MDF-Ti showed better machinability than did CP-Ti. MDF-Ti could be used as a framework material for RPDs.

Comparative Study on Wear Resistance and Hardness of Several Artificial Resin Teeth (수종의 인공 레진 치아의 마모저항성과 경도에 관한 비교 연구)

  • Choi, Yu-Sung;Lee, Joon-Seok;Cho, In-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.24 no.2
    • /
    • pp.129-146
    • /
    • 2008
  • The aim of this study was to compare and analyze wear resistance of acrylic resin tooth in denture opposing to different types of restoration materials. Also, it aimed to compare and analyze the hardness of three various types of resin artificial teeth when using five different types of denture detergents. In this study three types of artificial teeth were used. As ordinary acrylic resin tooth $Trubyte^{(R)}Biotone^{(R)}$ (Dentsply, U.S.A.) was used, and as high hardness resin tooth Endura $Posterio^{(R)}$ (Shofu, Japan) and Physio $Duracross^{(R)}$ (Nissin, Japan) were used. To compare wear resistance, gold alloy, dental porcelain, and composite resin were used as opposing restorations. In addition, with three types of resin tooth stated above, five types of denture detergents, which are $Yuhanrox^{(R)}$ (Yuhanclorox, Korea), $Polident^{(R)}$ (Yuhan Co., Korea), $Cidex^{(R)}OPA$ (Johnson & Johnson Medical Co., Korea), $Hexamedin^{(R)}$ (Bukwang Pharm Co., Korea) and Daihan sterile $water^{(R)}$ (Daihan Pharm Co., Korea) were used to compare and analyze the effects denture detergents have on the surface hardness. The results of this study were as follow : 1. When composite resin and dental porcelain were used as the opposing restorations, $Trubyte^{(R)}$ $Biotone^{(R)}$, Endura $Posterio^{(R)}$, Physio $Duracross^{(R)}$ in ascending order showed decrease of cusp height with significant difference (p<0.05). 2. When gold alloy was used as opposing restoration, there was decrease in the cusp height in order of $Trubyte^{(R)}Biotone^{(R)}$, Endura $Posterio^{(R)}$, Physio $Duracross^{(R)}$ and $Trubyte^{(R)}$ $Biotone^{(R)}$ especially showed significant decrease in high cusp height as compared to two other types of artificial tooth (p<0.05). 3. When composite resin, gold alloy and dental porcelain were used as opposing restorations, $Trubyte^{(R)}$ $Biotone^{(R)}$, Endura $Posterio^{(R)}$, Physio $Duracross^{(R)}$ in order decreased greatly in weight and these three materials showed significant difference (p<0.05). 4. Comparing the experiment values, decrease in strength had significant difference in all resin artificial teeth before and after the denture detergents were used (p<0.05). 5. When resin artificial teeth were subsided in $Yuhanrox^{(R)}$, $Cidex^{(R)}OPA$, and $Hexamedin^{(R)}$, $Trubyte^{(R)}$ $Biotone^{(R)}$, Endura $Posterio^{(R)}$, Physio $Duracross^{(R)}$ in order showed decrease in hardness, and $Trubyte^{(R)}$ $Biotone^{(R)}$ especially showed significant high decrease hardness as to other two types of artificial teeth (p<0.05). Therefore, Physio $Duracross^{(R)}$ seems to have superior wear resistance, and together with Endura $Posterio^{(R)}$, it presents excellent hardness as compared to $Trubyte^{(R)}$ $Biotone^{(R)}$. However, since this study is fragmentary, it should be given careful consideration and more study need to be done before making a definitive conclusion.

Full mouth rehabilitation using various digital tools in a patient with collapsed bite due to severe attrition (심한 마모로 인하여 교합이 붕괴된 환자의 다양한 디지털 도구를 이용한 완전 구강회복증례)

  • Moon, Sooin;Lee, Younghoo;Hong, Seoung-Jin;Noh, Kwantae;Pae, Ahran;Kim, Hyeong-Seob;Kwon, Kung-Rock;Paek, Janghyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.4
    • /
    • pp.320-329
    • /
    • 2022
  • Physiological wear of occlusal surface is inevitable throughout the lifetime, and considered to be normal. Pathologic wear, however, may cause fatal damage to the occlusal surface and destroy esthetics and proper anterior guidance. In such cases, rehabilitation of occlusal wear should be followed by thorough evaluation and diagnosis. In this present case, severe occlusal wear was found in the labial surfaces of mandibular anterior teeth and palatal surfaces of maxillary anterior teeth. Occlusal vertical dimension was evaluated and decided to be regained due to insufficient amount of restorative space. After determining new occlusal vertical dimension, diagnostic wax-up is usually performed to continue prosthodontic treatment. In this case with collapsed occlusion and loss of occlusal vertical dimension, conventional diagnostic wax-up was replaced with various digital devices. Diagnostic wax-up was digitally performed in the software and provisional prosthesis was fabricated with digital tools. With verification with provisional prosthesis, the entire dentition was rehabilitated with newly set occlusal vertical dimension and proper anterior guidance.

Estimation of cutting forces in band sawing (톱절삭에서의 절삭력 예측)

  • Jung, Hoon;Baek, Dae-Kyun;Ko, Tae-Jo;Kim, Hee-Sool
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1996.11a
    • /
    • pp.31-35
    • /
    • 1996
  • The cross section of the circular rod type workpiece to be cut in the band saw machine is variable at every moment in the sawing process. When the cutting feed rate is fixed to the constant speed, the cutting edges of the band saw teeth are also variabl eat any moment, so this causes the wear of the land saw teeth and the deterioration of the quality in the surface roughness. In this study, to work out this kind of problem basically, the mean cutting force of a tooth in the band saw was estimated by using the workpiece which was smaller than the interval of each tooth, i.e. band saw pitch, in the thickness. Then the static cutting forces were predicted by appling the mean cutting forces referred above to the mechanistic cutting force model which were analyzed through the geometric profile of a band saw tooth.

  • PDF

Fabrication of R.P.D framework by using Acetal Resin (Acetal resin을 이용한 R.P.D framework의 제작)

  • Kim, Chung-Sook;Park, Myoung-Ho
    • Journal of Technologic Dentistry
    • /
    • v.23 no.1
    • /
    • pp.107-114
    • /
    • 2001
  • R.P.D fabrication can be made if the skills already is properly used in the manufacturing press. You may feel extremely comfortable to wear it. The material used has high elasticity that it can endure the hole process of Acetal Wax pattern casting without any deformation moreover its adaptability is not bad. Because of the poor financial condition of patterns and health insurance, Acetal R.P.D Framework can be one of the best alternatives used for setting clasp partial denture cheaply. R.P.D Framework is aesthetically excellent. The color caused by saliva is so similar to that of the rest of teeth that even dentists as well as patients can not recognize clasp arm. Clasp also helps to secure prosthesis ideally without damaging teeth due to its deep position downward. Since dentists and patients have a good reaction to clasp so far, we are encouraged to apply it to other technical fields.

  • PDF

Re-establishment of occlusal plane in a patient with a failed implant prosthesis (실패한 임플란트 보철수복물을 가진 환자의 교합평면 재설정)

  • Kang, Hyeon-Goo;Ko, Kyung-Ho;Huh, Yoon-Hyuk;Cho, Lee-Ra;Park, Chan-Jin
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.56 no.2
    • /
    • pp.141-153
    • /
    • 2018
  • A non-physiological occlusal plane caused by continuous tooth loss, occlusal wear, and failure of a prosthesis may result in an unattractive appearance and functional problems, such as reduced masticatory efficiency and occlusal interference. Therefore, when undertaking prosthetic treatment for edentulous patients or patients with a collapsed occlusal plane, it is important to establish an occlusal plane that is compatible with masticatory function. The patient in this case report had undergone restoration of a completely edentulous maxilla using an implant-supported fixed prosthesis. On follow-up examination in the following 6 years, mechanical complications were observed in the existing implant prosthesis, including porcelain chipping, occlusal wear, and screw loosening. Moreover, due to occlusal wear and supraeruption of the opposing anterior teeth, as well as loss of some posterior teeth, the occlusal plane had collapsed. Following diagnosis, the patient underwent full mouth rehabilitation, involving additional implant installation in edentulous sites, recreation of the existing prosthesis, and prosthetic restoration of all remaining teeth.

Full mouth rehabilitation with vertical dimension increase in patient with severely worn out dentition (과도한 마모를 가진 환자의 수직 고경 증가를 동반한 전악수복 증례)

  • Jung, Ji-Hye
    • The Journal of the Korean dental association
    • /
    • v.54 no.6
    • /
    • pp.438-446
    • /
    • 2016
  • Severe tooth wear may cause the pathologic change of the TMJ and masticatory muscles, unesthetic facial appearance, pathogenic pulp and occlusal disharmony. Treating patients with severely worn dentition often requires full mouth rehabilitation with increasing vertical dimension. Proper diagnosis and treatment planning are important for esthetic and functional definitive restorations and the long term stability of the neuromuscular system and the TMJ. In this case, 66 year-old female presented with generalized worn dentition. Based on assessment, pathologic destruction of teeth structure on entire dentition was caused by masticatory force and diet habit without loss of vertical dimension. Subsequently, 3 mm increase of vertical dimension that based on incisor for tooth restoration and esthetic improvement was determined. After 8 weeks stabilization period with temporary fixed prostheses, definitive prostheses were fabricated. After 6 months follow up period, satisfactory outcomes were attained both functional and esthetic aspects through this procedure.

  • PDF