Browse > Article
http://dx.doi.org/10.4047/jap.2020.12.6.369

In vitro evaluation of a removable partial denture framework using multi-directionally forged titanium  

Suzuki, Ginga (Department of Removable Prosthodontics, Tsurumi University School of Dental Medicine)
Shimizu, Satoshi (Department of Removable Prosthodontics, Tsurumi University School of Dental Medicine)
Torii, Mana (Department of Removable Prosthodontics, Tsurumi University School of Dental Medicine)
Tokue, Ai (Department of Removable Prosthodontics, Tsurumi University School of Dental Medicine)
Ying, Guo (Department of Prosthodontics, Stomatological School of Capital Medical University)
Yoshinari, Masao (Department of Dental Engineering, Tsurumi University School of Dental Medicine)
Hoshi, Noriyuki (Prosthodontics & Oral Implantology, Graduate School, Kanagawa Dental University)
Kimoto, Katsuhiko (Prosthodontics & Oral Implantology, Graduate School, Kanagawa Dental University)
Miura, Hiromi (Department of Mechanical Engineering, Toyohashi University of Technology)
Hayakawa, Tohru (Department of Dental Engineering, Tsurumi University School of Dental Medicine)
Ohkubo, Chikahiro (Department of Removable Prosthodontics, Tsurumi University School of Dental Medicine)
Publication Information
The Journal of Advanced Prosthodontics / v.12, no.6, 2020 , pp. 369-375 More about this Journal
Abstract
PURPOSE. This study evaluated the availability of multi-directionally forged (MDF) titanium (Ti) as a component of removable partial dentures (RPDs). MDF-Ti remarkably improved the mechanical properties of RPDs due to its ultrafine-grained structure. MATERIALS AND METHODS. The wear resistance, plaque adhesion, and machinability of MDF-Ti were tested. As controls, commercially pure (CP) titanium was used for wear, plaque adhesion, and machinability tests. For wear resistance, the volume losses of the titanium teeth before and after wear tests were evaluated. Plaque adhesion was evaluated by the assay of Streptococcus mutans. In the machinability test, samples were cut and ground by a steel fissure bur and carborundum (SiC) point. An unpaired t-test was employed for the analysis of the significant differences between MDF-Ti and the control in the results for each test. RESULTS. Wear resistance and plaque adherence of MDF-Ti similar to those of CP-Ti (P>.05) were indicated. MDF-Ti exhibited significantly larger volume loss than CP-Ti in all conditions except 100/30,000 g/rpm in machinability tests (P<.05). CONCLUSION. Although the wear resistance and plaque adherence of MDF-Ti were comparable to those of controls, MDF-Ti showed better machinability than did CP-Ti. MDF-Ti could be used as a framework material for RPDs.
Keywords
Multi-directionally forged titanium (MDF-Ti); Wear resistance; Machinability; Removable partial dentures (RPDs);
Citations & Related Records
연도 인용수 순위
  • Reference
1 Ohkubo C, Hanatani S, Hosoi T. Present status of titanium removable dentures-a review of the literature. J Oral Rehabil 2008;35:706-14.   DOI
2 Takayama Y, Takishin N, Tsuchida F, Hosoi T. Survey on use of titanium dentures in Tsurumi University Dental Hospital for 11 years. J Prosthodont Res 2009;53:53-9.   DOI
3 Ohkubo C, Sato Y, Nishiyama Y, Suzuki Y. Titanium removable denture based on a one-metal rehabilitation concept. Dent Mater J 2017;36:517-23.   DOI
4 Prystowsky SD, Allen AM, Smith RW, Nonomura JH, Odom RB, Akers WA. Allergic contact hypersensitivity to nickel, neomycin, ethylenediamine, and benzocaine. Relationships between age, sex, history of exposure, and reactivity to standard patch tests and use tests in a general population. Arch Dermatol 1979;115:959-62.   DOI
5 Covington JS, McBride MA, Slagle WF, Disney AL. Quantization of nickel and beryllium leakage from base metal casting alloys. J Prosthet Dent 1985;54:127-36.   DOI
6 Morris HF. Veterans administration cooperative studies project no. 147. Part IV: Biocompatibility of base metal alloys. J Prosthet Dent 1987;58:1-5.   DOI
7 Sakai T, Takeda S, Nakamura M. The effects of particulate metals on cell viability of osteoblast-like cells in vitro. Dent Mater J 2002;21:133-46.   DOI
8 Kuroda S, Takeda S, Nakamura M. Effects of six particulate metals on osteoblast-like MG-63 and HOS cells in vitro. Dent Mater J 2003;22:507-20.   DOI
9 Long M, Rack HJ. Titanium alloys in total joint replacement-a materials science perspective. Biomaterials 1998;19:1621-39.   DOI
10 Niinomi M. Mechanical biocompatibilities of titanium alloys for biomedical applications. J Mech Behav Biomed Mater 2008;1:30-42.   DOI
11 Petch NJ. The cleavage strength of polycrystals. J Iron Steel Inst 1953;174:25-8.
12 Santos PF, Niinomi M, Cho K, Nakai M, Liu H, Ohtsu N, Hirano M, Ikeda M, Narushima T. Microstructures, mechanical properties and cytotoxicity of low cost beta Ti-Mn alloys for biomedical applications. Acta Biomater 2015;26:366-76.   DOI
13 Stenlund P, Omar O, Brohede U, Norgren S, Norlindh B, Johansson A, Lausmaa J, Thomsen P, Palmquist A. Bone response to a novel Ti-Ta-Nb-Zr alloy. Acta Biomater 2015;20:165-75.   DOI
14 Hall EO. The deformation and ageing of mild steel: II characteristics of the Luders deformation. Proc Phys Soc 1951;64: 742-7.   DOI
15 Pande CS, Cooper KP. Nanomechanics of Hall-Petch relationship in nanocrystalline materials. Prog Mater Sci 2009;54: 689-706.   DOI
16 Miura, H.; Yu, G.; Yang, X. Multi-directional forging of AZ61Mg alloy under decreasing temperature conditions and improvement of its mechanical properties. Mater Sci Eng A 2011;528:6981-992.   DOI
17 Tsuji N, Ito Y, Saito Y, Minamino Y. Strength and ductility of ultrafine grained aluminum and iron produced by ARB and annealing. Scripta Mater 2002;47:893-9.   DOI
18 Valiev RZ, Maxim MY, Bobruk EV, Raab GI. Grain refinement and mechanical behavior of the Al alloy, subjected to the new SPD technique. Mater Trans 2009;50:87-91.   DOI
19 Furukawa M, Horita Z, Nemoto M, Valiev RZ, Langdon TG. Microstructural characteristics of an ultrafine grain metal processed with equal-channel angular pressing. Mater Charact 1996;37:277-83.   DOI
20 Miura H, Kobayashi M. Development of ultrafine grained and high strength MDF pure titanium, Expected applications as biocompatible implants. Titanium Jpn 2014;62:31-3.
21 Hoshi N, Saita M, Kumasaka T, Banka M, Miura H, Kimoto K. A new phase in the development of high strength pure titanium by multi-directional forging. J Dent Mater 2013;32:403.
22 Arai Y, Hoshi N, Kumasaka T, Hayakawa T, Ohkubo C, Kimoto K. Development of optimal new titanium for dental implant material. J Jpn Soc Oral Implant 2017;30:152.
23 Suzuki G, Hoshi N, Kimoto K, Miura H, Hayakawa T, Ohkubo C. Electrochemical property and corrosion behavior of multi-directionally forged titanium in fluoride solution. Dent Mater J 2019;38:845-53.   DOI
24 Suzuki G, Hirota M, Hoshi N, Kimoto K, Miura H, Yoshinari M, Hayakawa T, Ohkubo C. Effect of surface treatment of multi-directionally forged (MDF) titanium implant on bone response. Metals 2019;9:230.   DOI
25 Ohkubo C, Shimura I, Aoki T, Hanatani S, Hosoi T, Okabe T. In vitro wear assessment of titanium alloy teeth. J Prosthodont 2002;11:263-9.   DOI
26 Quirynen M, Bollen CM, Papaioannou W, Van Eldere J, van Steenberghe D. The influence of titanium abutment surface roughness on plaque accumulation and gingivitis: short-term observations. Int J Oral Maxillofac Implants 1996;11:169-78.
27 Ohkubo C, Takeuchi S, Sato Y, Shimura I, Aoki T, Tanaka Y, Watanabe I, Hosoi T. Wear resistance of magnetic Fe-Pt alloy teeth. Prosthodont Res Pract 2005;4:42-7.   DOI
28 Kabe S. Studies on attrition of CP titanium as metal teeth. Tsurumi Univ Dent J 1998;24:69-79.
29 Shimura I. In vitro study evaluated the relative wear resistance of CP titanium and artificial teeth materials. Tsurumi Univ Dent J 2001;27:45-58.
30 Urushibara Y, Ohshima T, Sato M, Hayashi Y, Hayakawa T, Maeda N, Ohkubo C. An analysis of the biofilms adhered to framework alloys using in vitro denture plaque models. Dent Mater J 2014;33:402-14.   DOI
31 Ohkubo C, Watanabe I, Ford JP, Nakajima H, Hosoi T, Okabe T. The machinability of cast titanium and Ti-6Al-4V. Biomaterials. 2000;21:421-8.   DOI
32 Watanabe I, Ohkubo C, Ford JP, Atsuta M, Okabe T. Cutting efficiency of air-turbine burs on cast titanium and dental casting alloys. Dent Mater 2000;16:420-5.   DOI
33 Watanabe I, Kiyosue S, Ohkubo C, Aoki T, Okabe T. Machinability of cast commercial titanium alloys. J Biomed Mater Res 2002;63:760-4.   DOI
34 Ohkubo C, Hosoi T, Ford JP, Watanabe I. Effect of surface reaction layer on grindability of cast titanium alloys. Dent Mater 2006;22:268-74.   DOI
35 Ohkubo C, Shimura I, Aoki T, Hanatani S, Hosoi T, Hattori M, Oda Y, Okabe T. Wear resistance of experimental Ti-Cu alloys. Biomaterials 2003;24:3377-81.   DOI