• Title/Summary/Keyword: Technology-Engineering

Search Result 92,641, Processing Time 0.121 seconds

Group-based Adaptive Rendering for 6DoF Immersive Video Streaming (6DoF 몰입형 비디오 스트리밍을 위한 그룹 분할 기반 적응적 렌더링 기법)

  • Lee, Soonbin;Jeong, Jong-Beom;Ryu, Eun-Seok
    • Journal of Broadcast Engineering
    • /
    • v.27 no.2
    • /
    • pp.216-227
    • /
    • 2022
  • The MPEG-I (Immersive) group is working on a standardization project for immersive video that provides 6 degrees of freedom (6DoF). The MPEG Immersion Video (MIV) standard technology is intended to provide limited 6DoF based on depth map-based image rendering (DIBR) technique. Many efficient coding methods have been suggested for MIV, but efficient transmission strategies have received little attention in MPEG-I. This paper proposes group-based adaptive rendering method for immersive video streaming. Each group can be transmitted independently using group-based encoding, enabling adaptive transmission depending on the user's viewport. In the rendering process, the proposed method derives weights of group for view synthesis and allocate high quality bitstream according to a given viewport. The proposed method is implemented through the Test Model for Immersive Video (TMIV) test model. The proposed method demonstrates 17.0% Bjontegaard-delta rate (BD-rate) savings on the peak signalto-noise ratio (PSNR) and 14.6% on the Immersive Video PSNR(IV-PSNR) in terms of various end-to-end evaluation metrics in the experiment.

Characterization of Charcoals prepared by Korean Traditional Kiln (우리나라 전통 숯가마로부터 생산된 숯의 특성분석)

  • An, Ki Sun;Kwak, Lee Ku;Kim, Hong Gun;Ryu, Seung Kon
    • Korean Chemical Engineering Research
    • /
    • v.60 no.2
    • /
    • pp.208-216
    • /
    • 2022
  • Surface morphology and adsorption characteristics of black and white charcoals prepared from Korean traditional kiln were quantitatively analyzed. TGA and elemental analysis of charcoals were different from produced kiln, and thermal degradation temperature and carbon content of white charcoals were apparently higher than those of black charcoals. Surface morphology shows the activation progressed through the longitudinal direction of woods and new micropores were developed to radial direction on the surface of macropores as the furthermore activation resulting in the pore connection. BET adsorption isotherms show that there are low-pressure hysteresis due to the no desorption of adsorbates, which resulted in unique Type of charcoals overlapping Type I and Type IV. Such a low-pressure hysteresis is occurred from expansion of adsorbates, which were embedded in the micropore entrances and did not get out during the desorption run. The characteristics of charcoals such as specific surface area and pore size distribution did not show correct values depending on not only produced company but also sampling sites of one piece of charcoal. Therefore, it is not easy to suggest the quantitative characteristics of charcoals prepared from Korean traditional kiln. On the other hand, preparation the quality standard of charcoal is necessary for their special uses such as adsorbent.

Design of an Visitor Identification system for the Front Door of an Apartment using Deep learning (딥러닝 기반 이용한 공동주택현관문의 출입자 식별 시스템 설계)

  • Lee, Min-Hye;Mun, Hyung-Jin
    • Journal of the Korea Convergence Society
    • /
    • v.13 no.4
    • /
    • pp.45-51
    • /
    • 2022
  • Fear of contact exists due to the prevention of the spread of infectious diseases such as COVID-19. When using the common entrance door of an apartment, access is possible only if the resident enters a password or obtains the resident's permission. There is the inconvenience of having to manually enter the number and password for the common entrance door to enter. Also, contactless entry is required due to COVID-19. Due to the development of ICT, users can be easily identified through the development of face recognition and voice recognition technology. The proposed method detects a visitor's face through a CCTV or camera attached to the common entrance door, recognizes the face, and identifies it as a registered resident. Then, based on the registered information of the resident, it is possible to operate without contact by interworking with the elevator on the server. In particular, if face recognition fails with a hat or mask, the visitor is identified by voice or additional authentication of the visitor is performed based on the voice message. It is possible to block the spread of contagiousness without leaving any contactless function and fingerprint information when entering and exiting the front door of an apartment house, and without the inconvenience of access.

A Study on the Expansion of Workflow for the Collection of Surface Web-based OSINT(Open Source Intelligence) (표면 웹기반 공개정보 수집을 위한 워크플로우 확장 연구)

  • Lee, SuGyeong;Choi, Eunjung;Kim, Jiyeon;Lee, Insoo;Lee, Seunghoon;Kim, Myuhngjoo
    • Journal of Digital Convergence
    • /
    • v.20 no.4
    • /
    • pp.367-376
    • /
    • 2022
  • In traditional criminal cases, there is a limit to information collection because information on the subject of investigation is provided only with personal information held by the national organization of legal. Surface web-based OSINT(Open Source Intelligence), including SNS and portal sites that can be searched by general search engines, can be used for meaningful profiling for criminal investigations. The Korean-style OSINT workflow can effectively profile based on OSINT, but in the case of individuals, OSINT that can be collected is limited because it begins with "name", and the reliability is limited, such as collecting information of the persons with the same name. In order to overcome these limitations, this paper defines information related to individuals, i.e., equivalent information, and enables efficient and accurate information collection based on this. Therefore, we present an improved workflow that can extract information related to a specific person, ie., equivalent information, from OSINT. For this purpose, different workflows are presented according to the person's profile. Through this, effective profiling of a person (individuals) is possible, thereby increasing reliability in collecting investigation information. According to this study, in the future, by developing a system that can automate the analysis process of information collected using artificial intelligence technology, it can lay the foundation for the use of OSINT in criminal investigations and contribute to diversification of investigation methods.

Inhibitory effects of the atypical antipsychotic, clozapine, on voltage-dependent K+ channels in rabbit coronary arterial smooth muscle cells

  • Kang, Minji;Heo, Ryeon;Park, Seojin;Mun, Seo-Yeong;Park, Minju;Han, Eun-Taek;Han, Jin-Hee;Chun, Wanjoo;Ha, Kwon-Soo;Park, Hongzoo;Jung, Won-Kyo;Choi, Il-Whan;Park, Won Sun
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.26 no.4
    • /
    • pp.277-285
    • /
    • 2022
  • To investigate the adverse effects of clozapine on cardiovascular ion channels, we examined the inhibitory effect of clozapine on voltage-dependent K+ (Kv) channels in rabbit coronary arterial smooth muscle cells. Clozapine-induced inhibition of Kv channels occurred in a concentration-dependent manner with an half-inhibitory concentration value of 7.84 ± 4.86 µM and a Hill coefficient of 0.47 ± 0.06. Clozapine did not shift the steady-state activation or inactivation curves, suggesting that it inhibited Kv channels regardless of gating properties. Application of train pulses (1 and 2 Hz) progressively augmented the clozapine-induced inhibition of Kv channels in the presence of the drug. Furthermore, the recovery time constant from inactivation was increased in the presence of clozapine, suggesting that clozapine-induced inhibition of Kv channels is use (state)-dependent. Pretreatment of a Kv1.5 subtype inhibitor decreased the Kv current amplitudes, but additional application of clozapine did not further inhibit the Kv current. Pretreatment with Kv2.1 or Kv7 subtype inhibitors partially blocked the inhibitory effect of clozapine. Based on these results, we conclude that clozapine inhibits arterial Kv channels in a concentration-and use (state)-dependent manner. Kv1.5 is the major subtype involved in clozapine-induced inhibition of Kv channels, and Kv2.1 and Kv7 subtypes are partially involved.

Study on the Shortest Path finding of Engine Room Patrol Robots Using the A* Algorithm (A* 알고리즘을 이용한 기관실 순찰로봇의 최단 경로 탐색에 관한 연구)

  • Kim, Seon-Deok
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.28 no.2
    • /
    • pp.370-376
    • /
    • 2022
  • Smart ships related studies are being conducted in various fields owing to the development of technology, and an engine room patrol robot that can patrol the unmanned engine room is one such study. A patrol robot moves around the engine room based on the information learned through artificial intelligence and checks the machine normality and occurrence of abnormalities such as water leakage, oil leakage, and fire. Study on engine room patrol robots is mainly conducted on machine detection using artificial intelligence, however study on movement and control is insufficient. This causes a problem in that even if a patrol robot detects an object, there is no way to move to the detected object. To secure maneuverability to quickly identify the presence of abnormality in the engine room, this study experimented with whether a patrol robot can determine the shortest path by applying the A* algorithm. Data were obtained by driving a small car equipped with LiDAR in the ship engine room and creating a map by mapping the obtained data with SLAM(Simultaneous Localization And Mapping). The starting point and arrival point of the patrol robot were set on the map, and the A* algorithm was applied to determine whether the shortest path from the starting point to the arrival point was found. Simulation confirmed that the shortest route was well searched while avoiding obstacles from the starting point to the arrival point on the map. Applying this to the engine room patrol robot is believed to help improve ship safety.

Effect of ammonia nitrogen and microorganisms on the elevated nitrogenous biochemical oxygen demand (NBOD) levels in the Yeongsan river in Gwangju (광주지역 영산강의 NBOD 발생에 대한 암모니아성 질소 및 미생물 영향 연구)

  • Jang, Dong;Cho, Gwangwoon;Son, Gyeongrok;Kim, Haram;Kang, Yumi;Lee, Seunggi;Hwang, Soonhong;Bae, Seokjin;Kim, Yunhee
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.36 no.2
    • /
    • pp.81-95
    • /
    • 2022
  • The present study was performed to investigate the effects of NH3-N and nitrifying microorganisms on the increased BOD of downstream of the Yeongsan river in Gwangju. Water samples were collected periodically from the 13 sampling sites of rivers from April to October 2021 to monitor water qualities. In addition, the trends of nitrogenous biochemical oxygen demand (NBOD) and microbial clusters were analyzed by adding different NH3-N concentrations to the water samples. The monitoring results showed that NH3-N concentration in the Yeongsan river was 22 times increased after the inflow of discharged water from the Gwangju 1st public sewage treatment plant (G-1-PSTP). Increased NH3-N elevated NBOD levels through the nitrification process in the river, consequently, it would attribute to the increase of BOD in the Yeongsan river. Meanwhile, there was no proportional relation between NBOD and NH3-N concentrations. However, there was a significant difference in NBOD occurrence by sampling sites. Specifically, when 5 mg/L NH3-N was added, NBOD of the river sample showed 2-4 times higher values after the inflow of discharged water from G-1-PSTP. Therefore, it could be thought other factors such as microorganisms influence the elevated NBOD levels. Through next-generation sequencing analysis, nitrifying microorganisms such as Nitrosomonas, Nitroga, and Nitrospira (Genus) were detected in rivers samples, especially, the proportion of them was the highest in river samples after the inflow of discharged water from G-1-PSTP. These results indicated the effects of nitrifying microorganisms and NH3-N concentrations as important limiting factors on the increased NBOD levels in the rivers. Taken together, comprehensive strategies are needed not only to reduce the NH3-N concentration of discharged water but also to control discharged nitrifying microorganisms to effectively reduce the NBOD levels in the downstream of the Yeongsan river where discharged water from G-1-PSTP flows.

Research on Design Capacity Evaluation of Low Impact Development according to Design Criteria (저영향개발 시설 설계 기준에 따른 용량 평가 방법 연구)

  • Im, Jiyeol;Gil, Kyungik
    • Journal of Wetlands Research
    • /
    • v.24 no.1
    • /
    • pp.59-67
    • /
    • 2022
  • The interest in LID facilities is increasing worldwide for recovery of natural water cycle system to destroy by urbanization. However, problems are raised when installation of LID because comprehensive analysis about design capacity adequacy of LID facilities was not conducted completely. In this research, removal efficiency and design volume adequacy of LID facilities were analyzed based on rainfall monitoring data in four LID facilities(Vegetated Swale, Vegetative Filter Strip, Bio-Retention and Permeable Pavement). As a result, group of LID facility designed on WQV was shown higher flow(37%) and pollutants(TSS, BOD, TN and TP) removal efficiencies(20 ~ 37%) than group of LID facility designed on WQF. SA/CA graph was drawn for evaluation of design volume adequacy based on rainfall monitoring data. In this SA/CA graph, coefficient of determination show over 0.5 in all parameter, especially, Flow and TP were show over 0.95. And, 'SA/CA & L/CA' graph considering difference of structure mechanism in LID facility suggested in this research was confirmed that improved coefficient of determination in flow, TSS and TP than SA/CA graph. According to this research results, feasibility of applying 'SA/CA & L/CA' graph for evaluation of design volume adequacy in LID facility, and it is necessary to follow up research for generalization and normalization.

A Scalable Montgomery Modular Multiplier (확장 가능형 몽고메리 모듈러 곱셈기)

  • Choi, Jun-Baek;Shin, Kyung-Wook
    • Journal of IKEEE
    • /
    • v.25 no.4
    • /
    • pp.625-633
    • /
    • 2021
  • This paper describes a scalable architecture for flexible hardware implementation of Montgomery modular multiplication. Our scalable modular multiplier architecture, which is based on a one-dimensional array of processing elements (PEs), performs word parallel operation and allows us to adjust computational performance and hardware complexity depending on the number of PEs used, NPE. Based on the proposed architecture, we designed a scalable Montgomery modular multiplier (sMM) core supporting eight field sizes defined in SEC2. Synthesized with 180-nm CMOS cell library, our sMM core was implemented with 38,317 gate equivalents (GEs) and 139,390 GEs for NPE=1 and NPE=8, respectively. When operating with a 100 MHz clock, it was evaluated that 256-bit modular multiplications of 0.57 million times/sec for NPE=1 and 3.5 million times/sec for NPE=8 can be computed. Our sMM core has the advantage of enabling an optimized implementation by determining the number of PEs to be used in consideration of computational performance and hardware resources required in application fields, and it can be used as an IP (intellectual property) in scalable hardware design of elliptic curve cryptography (ECC).

An On-line Survey on the Perception and Usage of Korean Medicine Doctors about Pattern Identification of Eight Principles (국내 한의사의 팔강변증에 관한 인식 및 활용현황 조사)

  • Bae, Jung Hyeon;Park, Shin Hyung;Lee, In Seon;Kim, Jong Won;Jeon, Soo Hyung;Kang, Chang Wan;Chi, Gyoo Yong
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.35 no.6
    • /
    • pp.211-218
    • /
    • 2021
  • In order to increase the clinical value of an identification of patterns according to the eight principles (IPEP) in Korean medicine practice, The research on the Clinical Practice Guideline (CPG) of IPEP should comprehend the situation of clinical usage of IPEP practiced by Korean medicine doctors at first. Google survey form were emailed to Korean Medicine doctors registered in the Association of Korean Medicine on 04/15/2021 and the survey was closed at 04/22/2021. Data of 505 answered cases were analyzed by Frequency analysis, Chi-Square analysis, correlation analysis for understanding differences by groups. Out of 505 respondents, 57.6% have answered that they are using IPEP. It means that 42.4% of KM doctors don't use in the medical practice reversely in spite of fundamental diagnostic theory. The 64.7% respondents of no using IPEP presented their opinion about the theoretical problem that it is difficult to use because the concept of IPEP is ambiguous. And next, the 52.1% of the respondents expressed that there is no objective tools to measure and record the IPEP evidences in actual implementation. And 49.6% of the respondents also suggested that it is hard to trust and use IPEP similar to the previous comment. Even about 50% of the respondents are carrying out diagnosis and treatment using IPEP, it showed that there were several unsolved problems such as lack of understanding and practical tools or objective indicators for diagnosis of IPEP. Through the above results, the concept, usage, measurement requirements with indices and discriminant logic of IPEP were manifested as the main hopes of attending members of Korean medicine in the survey, so the IPEP CPG should make clear about these difficult but necessary assignment in the near future.