• Title/Summary/Keyword: Technology technique

Search Result 13,180, Processing Time 0.04 seconds

A study on the appropriateness of using traditional technique in the field of Architectural heritage conservation - Through Comparing properties - (건조물 문화재 수리에 있어서 전통기술의 적합성 연구 - 기술의 속성 비교를 통하여 -)

  • Oh, Kyusung
    • Journal of architectural history
    • /
    • v.31 no.5
    • /
    • pp.7-20
    • /
    • 2022
  • Traditional building technique has been used as the main technology in the field of architectural heritage conservation in South Korea. It has remained this way with very little resistance until now. But the time has come to question the appropriateness of traditional technique as conservation technique. In this paper a study was done on the properties of the traditional technique and the architectural heritage conservation technique in order to define the appropriateness between the two techniques. As a result the traditional technique was found to be unfit for conservation technique. The reasons are as follows. First, there is a time gap between the traditional technique and the time when the heritage was first built. Second, conservation work is about retaining the values of being a heritage while the traditional technique is about safeness and practicality. Third, the use of traditional technique comes with using the tools of its time which cannot ensure the safety of the heritage. The traditional technique must be looked upon as one of an option in the field of conservation. We must develop a better conservation technology by finding balance between the traditional technique and modern science. And further more an aggressive investment must be made in order to realize this objective.

Reduction of Scattered Radiation by Air Gap Technique for High Kilovoltage Chest Roentgenography (흉부(胸部) 고관전압(高管電壓) 촬영(撮影)에 있어 Air Gap Technique를 이용한 산란선(散亂線) 경감(輕減)에 관(關)한 연구(硏究))

  • Huh, Joon;Kim, Chang-Kyun;Kang, Hong-Seok;Youn, Chul-Ho;Lee, Sang-Suk;Lim, Han-Young;Song, Jae-Kwan
    • Journal of radiological science and technology
    • /
    • v.3 no.1
    • /
    • pp.57-66
    • /
    • 1980
  • X-ray grid is the most important means to reduce the scattered ray from patients, but alternative way is air gap technique that is another name of Groedel technique. This technique is mainly used in chest radiography. Authors performed an experimental study on the air gap technique for chest radiography and obtained the results as follows; 1. In using the high voltage air technique, scattered ray could be reduced effectively, while the percentage of scattered ray was slightly increased than conventional grid technique. 2. In film contrast, 30cm air gap technique was inferior to 12:1 grid technique and contrast improvement was increased when the object was thicker and higher voltage was used. 3. The patient exposure dose was reduced about $25{\sim}45%$ compared with conventional grid technique by air gap technique used.

  • PDF

IMPROVEMENT OF CROSS-CORRELATION TECHNIQUE FOR LEAK DETECTION OF A BURIED PIPE IN A TONAL NOISY ENVIRONMENT

  • Yoon, Doo-Byung;Park, Jin-Ho;Shin, Sung-Hwan
    • Nuclear Engineering and Technology
    • /
    • v.44 no.8
    • /
    • pp.977-984
    • /
    • 2012
  • The cross-correlation technique has been widely used for leakage detection of buried pipes, and this technique can be successfully applied when the leakage signal has a high signal-to-noise ratio. In the case of a power plant, the measured leakage signals obtained from the sensors may contain background noise and mechanical noise generated by adjacent machinery. In such a case, the conventional method using the cross-correlation function may fail to estimate the leakage point. In order to enhance the leakage estimation capability of a buried pipe in a noisy environment, an improved cross-correlation technique is proposed. It uses a noise rejection technique in the frequency domain to effectively eliminate the tonal noise due to rotating machinery. Experiments were carried out to verify the validity of the proposed method. The results show that even in a tonal noisy environment, the proposed method can provide more reliable means for estimating the time delay of the leakage signals.

Inductive Switching Noise Suppression Technique for Mixed-Signal ICs Using Standard CMOS Digital Technology

  • Im, Hyungjin;Kim, Ki Hyuk
    • Journal of information and communication convergence engineering
    • /
    • v.14 no.4
    • /
    • pp.268-271
    • /
    • 2016
  • An efficient inductive switching noise suppression technique for mixed-signal integrated circuits (ICs) using standard CMOS digital technology is proposed. The proposed design technique uses a parallel RC circuit, which provides a damping path for the switching noise. The proposed design technique is used for designing a mixed-signal circuit composed of a ring oscillator, a digital output buffer, and an analog noise sensor node for $0.13-{\mu}m$ CMOS digital IC technology. Simulation results show a 47% reduction in the on-chip inductive switching noise coupling from the noisy digital to the analog blocks in the same substrate without an additional propagation delay. The increased power consumption due to the damping resistor is only 67% of that of the conventional source damping technique. This design can be widely used for any kind of analog and high frequency digital mixed-signal circuits in CMOS technology

Development of Dark Field image Processing Technique for the Investigation of Nanostructures

  • Jeon, Jongchul;Kim, Kyou-Hyun
    • Journal of Powder Materials
    • /
    • v.24 no.4
    • /
    • pp.285-291
    • /
    • 2017
  • We propose a custom analysis technique for the dark field (DF) image based on transmission electron microscopy (TEM). The custom analysis technique is developed based on the $DigitalMicrograph^{(R)}$ (DM) script language embedded in the Gatan digital microscopy software, which is used as the operational software for most TEM instruments. The developed software automatically scans an electron beam across a TEM sample and records a series of electron diffraction patterns. The recorded electron diffraction patterns provide DF and ADF images based on digital image processing. An experimental electron diffraction pattern is recorded from a IrMn polycrystal consisting of fine nanograins in order to test the proposed software. We demonstrate that the developed image processing technique well resolves nanograins of ~ 5 nm in diameter.

Adaptive Input-Output Linearization Technique for Robust Speed Control of Brushless DC Motor

  • Kim, Kyeong-Hwa;Baik, In-Cheol;Kim, Hyun-Soo;Youn, Myung-Joong
    • Journal of Electrical Engineering and information Science
    • /
    • v.2 no.3
    • /
    • pp.113-122
    • /
    • 1997
  • An adaptive input-output linearization technique for a robust speed control of a brushless C(BLDC) motor is presented. By using this technique, the nonlinear moro model can be effectively linearized in Brunovski canonical form, an the desired speed dynamics can be obtained based on the linearized model. This control technique, however, gives an undesirable output performance under the mismatch of the system parameters and load conditions caused by the incomplete linearization. for the robust output response, the controller parameters will be estimated by a model reference adaptive technique where the disturbance torque and flux linkage are estimated. The adaptation laws are derived by the Popov's hyperstability theory nd positivity concept. The proposed control scheme is implemented on a BLDC motor using the software of DSP TMS320C30 and the effectiveness is verified through the comparative simualtions and experiments.

  • PDF

Synchronous Periodic Frequency Modulation Based on Interleaving Technique to Reduce PWM Vibration Noise

  • Zhang, Wentao;Xu, Yongxiang;Ren, Jingwei;Su, Jianyong;Zou, Jibin
    • Journal of Power Electronics
    • /
    • v.19 no.6
    • /
    • pp.1515-1526
    • /
    • 2019
  • Ear-piercing high-frequency noise from electromagnetic vibrations in motors has become unacceptable in sensitive environments, due to the application of pulse width modulation (PWM) and in consideration of switching losses. This paper proposed a synchronous periodic frequency modulation (SPFM) method based on the interleaving technique for paralleled three-phase voltage source inverters (VSIs) to eliminate PWM vibration noise. The proposed SPFM technique is able to effectively remove unpleasant high-frequency vibration noise as well as acoustic noise more effectively than the conventional periodic carrier frequency modulation (PCFM) and interleaving technique. It completely eliminates the vibration noise near odd-order carrier frequencies and reduces the PWM vibration noise near even-order carrier frequencies depending on the switching frequency variation range. Furthermore, the SPFM method is simple to implement and does not employ additional circuits in the drive system. Finally, the effectiveness of the proposed method has been confirmed by detailed experimental results.

A New Random PWM Technique for Conducted-EMI Mitigation on Cuk Converter

  • Krishnakumar, C.;Muhilan, P.;Sathiskumar, M.;Sakthivel, M.
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.3
    • /
    • pp.916-924
    • /
    • 2015
  • Electromagnetic Interference (EMI) is a system to system or environment to system phenomenon. The literature survey proved that the Randomized Pulse Width Modulation (RPWM) technique is a promising technique to reduce EMI. A new Constant Trailing Edge, Randomized Pulse Width Modulation (CTERPWM) technique is proposed in this paper. The effect of the proposed RPWM technique for mitigation of conducted-EMI on Cuk converter operating in Continuous Conduction Mode (CCM) is simulated and tested. In this paper, the analytical expressions for the Power Spectral Density (PSD) are derived for the proposed RPWM technique and are validated by experimental measurements. The effectiveness of the proposed RPWM technique on the mitigation of conducted-EMI is verified comparing simulation and experimental results and it is identified that both the results are almost similar with allowable experimental deviations. The comparative investigation proves that the proposed RPWM technique can mitigate and spread the dominant peaks of conducted-EMI over the complete spectrum for the Cuk converter. Based on the investigation the CTERPWM technique is recommended for adoption.

A Regression Test Selection and Prioritization Technique

  • Malhotra, Ruchika;Kaur, Arvinder;Singh, Yogesh
    • Journal of Information Processing Systems
    • /
    • v.6 no.2
    • /
    • pp.235-252
    • /
    • 2010
  • Regression testing is a very costly process performed primarily as a software maintenance activity. It is the process of retesting the modified parts of the software and ensuring that no new errors have been introduced into previously tested source code due to these modifications. A regression test selection technique selects an appropriate number of test cases from a test suite that might expose a fault in the modified program. In this paper, we propose both a regression test selection and prioritization technique. We implemented our regression test selection technique and demonstrated in two case studies that our technique is effective regarding selecting and prioritizing test cases. The results show that our technique may significantly reduce the number of test cases and thus the cost and resources for performing regression testing on modified software.

Wavelet PWM Technique for Single-Phase Three-Level Inverters

  • Zheng, Chun-Fang;Zhang, Bo;Qiu, Dong-Yuan;Zhang, Xiao-Hui;Xiao, Le-Ming
    • Journal of Power Electronics
    • /
    • v.15 no.6
    • /
    • pp.1517-1523
    • /
    • 2015
  • The wavelet PWM (WPWM) technique has been applied in two-level inverters successfully, but directly applying the WPWM technique to three-level inverters is impossible. This paper proposes a WPWM technique suitable for a single-phase three-level inverter. The work analyzes the control strategy with the WPWM and obtains the design of its parameters. Compared with the SPWM technique for a single-phase three-level inverter under the same conditions, the WPWM can obtain high magnitudes of the output fundamental frequency component, low total harmonic distortion, and simpler digital implementation. The feasibility experiment is given to verify of the proposed WPWM technique.