• Title/Summary/Keyword: Target material

Search Result 1,366, Processing Time 0.038 seconds

Development of Greenhouse Cooling and Heating Load Calculation Program Based on Mobile (모바일 기반 온실 냉난방 부하 산정 프로그램 개발)

  • Moon, Jong Pil;Bang, Ji Woong;Hwang, Jeongsu;Jang, Jae Kyung;Yun, Sung Wook
    • Journal of Bio-Environment Control
    • /
    • v.30 no.4
    • /
    • pp.419-428
    • /
    • 2021
  • In order to develope a mobile-based greenhouse energy calculation program, firstly, the overall thermal transmittance of 10 types of major covers and 16 types of insulation materials were measured. In addition, to estimate the overall thermal transmittance when the cover and insulation materials were installed in double or triple layers, 24 combinations of double installations and 59 combinations of triple installations were measured using the hotbox. Also, the overall thermal transmittance value for a single material and the thermal resistance value were used to calculate the overall thermal transmittance value at the time of multi-layer installation of covering and insulating materials, and the linear regression equation was derived to correct the error with the measured values. As a result of developing the model for estimating thermal transmittance when installing multiple layers of coverings and insulating materials based on the value of overall thermal transmittance of a single-material, the model evaluation index was 0.90 (good when it is 0.5 or more), indicating that the estimated value was very close to the actual value. In addition, as a result of the on-site test, it was evaluated that the estimated heat saving rate was smaller than the actual value with a relative error of 2%. Based on these results, a mobile-based greenhouse energy calculation program was developed that was implemented as an HTML5 standard web-based mobile web application and was designed to work with various mobile device and PC browsers with N-Screen support. It had functions to provides the overall thermal transmittance(heating load coefficient) for each combination of greenhouse coverings and thermal insulation materials and to evaluate the energy consumption during a specific period of the target greenhouse. It was estimated that an energy-saving greenhouse design would be possible with the optimal selection of coverings and insulation materials according to the region and shape of the greenhouse.

Image quality and usefulness evaluaton of 3D-CBCT and Gated-CBCT according to baseline changes for SBRT of Lung Cancer (폐암 환자의 정위체부방사선치료 시 기준선 변화에 따른 3D-CBCT(Cone Beam Computed-Tomography)와 Gated-CBCT의 영상 품질 및 유용성 평가)

  • Han Kuk Hee;Shin Chung Hun;Lee Chung Hwan;Yoo Soon Mi;Park Ja Ram;Kim Jin Su;Yun In Ha
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.35
    • /
    • pp.41-51
    • /
    • 2023
  • Purpose: This study compares and analyzes the image quality of 3D-CBCT(Cone Beam Computed-Tomography) and Gated CBCT according to baseline changes during SBRT(Stereotactic Body RadioTherapy) in lung cancer patients to find a useful CBCT method for correcting movement due to breathing Materials and methods : Insert a solid tumor material with a diameter of 3 cm into the QUASARTM phantom. 4-Dimentional Computed-Tomography(4DCT) images were taken with a speed of the phantom at period 3 sec and a maximum amplitude of 20 mm. Using the contouring menu of the computerized treatment planning system EclipseTM Gross Tumor Volume was outlined on solid tumor material. Set-up the same as when acquiring a 4DCT image using Truebeam STxTM, breathing patterns with baseline changes of 1 mm, 3 mm, and 5 mm were input into the phantom to obtain 3D-CBCT (Spotlight, Full) and Gated-CBCT (Spotlight, Full) images five times repeatedly. The acquired images were compared with the Signal-to-Noise Ratio(SNR), Contrast-to-Noise Ratio(CNR), Tumor Volume Length, and Motion Blurring Ratio(MBR) based on the 4DCT image. Results: The average Signal-to-Noise Ratio, Contrast-to-Noise Ratio, Tumor Volume Length and Motion Blurring Ratio of Spotlight Gated CBCT images were 13.30±0.10%, 7.78±0.16%, 3.55±0.17%, 1.18±0.06%. As a result, Spotlight Gated-CBCT images according to baseline change showed better values than Spotligtht 3D-CBCT images. Also, the average Signal-to-Noise Ratio, Contrast-to-Noise Ratio, Tumor Volume Length and Motion Blurring Ratio of Full Gated CBCT images were 12.80±0.11%, 7.60±0.11%, 3.54±0.16%, 1.18±0.05%. As a result Full GatedCBCT images according to baseline change showed better values than Full 3D-CBCT images. Conclusion : Compared to 3D-CBCT images, Gated-CBCT images had better image quality according to the baseline change, and the effect of Motion Blurring Artifacts caused by breathing was small. Therefore, it is considered useful to image guided using Gated-CBCT when a baseline change occurs due to difficulty in regular breathing during SBRT that exposes high doses in a short period of time

  • PDF

Surgery Alone and Surgery Plus Postoperative Radiation Therapy for Patients with pT3N0 Non-small Cell Lung Cancer Invading the Chest Wall (흉벽을 침범한 pT3N0 비소세포폐암 환자에서 수술 단독과 수술 후 방사선치료)

  • 박영제;임도훈;김관민;김진국;심영목;안용찬
    • Journal of Chest Surgery
    • /
    • v.37 no.10
    • /
    • pp.845-855
    • /
    • 2004
  • Background: No general consensus has been available regarding the necessity of postoperative radiation therapy (PORT) and its optimal techniques in the patients with chest wall invasion (pT3cw) and node negative (N0) non-small cell lung cancer (NSCLC). We did retrospective analyses on the pT3cwN0 NSCLC patients who received PORT because of presumed inadequate resection margin on surgical findings. And we compared them with the pT3cwN0 NSCLC patients who did not received PORT during the same period. Material and Method: From Aug. of 1994 till June of 2002, 22 pT3cwN0 NSCLC patients received PORT-PORT (+) group- and 16 pT3cwN0 NSCLC patients had no PORT-PORT (-) group. The radiation target volume for PORT (+) group was confined to the tumor bed plus the immediate adjacent tissue only, and no regional lymphatics were included. The prognostic factors for all patients were analyzed and survival rates, failure patterns were compared with two groups. Result: Age, tumor size, depth of chest wall invasion, postoperative mobidities were greater in PORT (-) group than PORT (+) group. In PORT (-) group, four patients who were consulted for PORT did not receive the PORT because of self refusal (3 patients) and delay in the wound repair (1 patient). For all patients, overall survival (OS), disease-free survival (DFS), loco-regional recurrence-free survival (LRFS), and distant metastases-free survival (DMFS) rates at 5 years were 35.3%, 30.3%, 80.9%, 36.3%. In univariate and multivariate analysis, only PORT significantly affect the survival. The 5 year as rates were 43.3% in the PORT (+) group and 25.0% in PORT (-) group (p=0.03). DFS, LRFS, DMFS rates were 36.9%, 84.9%, 43.1 % in PORT (+) group and 18.8%, 79.4%, 21.9% in PORT(-) group respectively. Three patients in PORT (-) group died of intercurrent disease without the evidence of recurrence. Few suffered from acute and late radiation side effects, all of which were RTOG grade 2 or lower. Conclusion: The strategy of adding PORT to surgery to improve the probability not only of local control but also of survival could be justified, considering that local control was the most important component in the successful treatment of pT3cw NSCLC patients, especially when the resection margin was not adequate. Authors were successful in the marked reduction of the incidence as well as the severity of the acute and late side effects of PORT, without taking too high risk of the regional failures by eliminating the regional lymphatics from the radiation target volume.

Dosimetry of the Low Fluence Fast Neutron Beams for Boron Neutron Capture Therapy (붕소-중성자 포획치료를 위한 미세 속중성자 선량 특성 연구)

  • Lee, Dong-Han;Ji, Young-Hoon;Lee, Dong-Hoon;Park, Hyun-Joo;Lee, Suk;Lee, Kyung-Hoo;Suh, So-Heigh;Kim, Mi-Sook;Cho, Chul-Koo;Yoo, Seong-Yul;Yu, Hyung-Jun;Gwak, Ho-Shin;Rhee, Chang-Hun
    • Radiation Oncology Journal
    • /
    • v.19 no.1
    • /
    • pp.66-73
    • /
    • 2001
  • Purpose : For the research of Boron Neutron Capture Therapy (BNCT), fast neutrons generated from the MC-50 cyclotron with maximum energy of 34.4 MeV in Korea Cancer Center Hospital were moderated by 70 cm paraffin and then the dose characteristics were investigated. Using these results, we hope to establish the protocol about dose measurement of epi-thermal neutron, to make a basis of dose characteristic of epi-thermal neutron emitted from nuclear reactor, and to find feasibility about accelerator-based BNCT. Method and Materials : For measuring the absorbed dose and dose distribution of fast neutron beams, we used Unidos 10005 (PTW, Germany) electrometer and IC-17 (Far West, USA), IC-18, ElC-1 ion chambers manufactured by A-150 plastic and used IC-l7M ion chamber manufactured by magnesium for gamma dose. There chambers were flushed with tissue equivalent gas and argon gas and then the flow rate was S co per minute. Using Monte Carlo N-Particle (MCNP) code, transport program in mixed field with neutron, photon, electron, two dimensional dose and energy fluence distribution was calculated and there results were compared with measured results. Results : The absorbed dose of fast neutron beams was $6.47\times10^{-3}$ cGy per 1 MU at the 4 cm depth of the water phantom, which is assumed to be effective depth for BNCT. The magnitude of gamma contamination intermingled with fast neutron beams was $65.2{\pm}0.9\%$ at the same depth. In the dose distribution according to the depth of water, the neutron dose decreased linearly and the gamma dose decreased exponentially as the depth was deepened. The factor expressed energy level, $D_{20}/D_{10}$, of the total dose was 0.718. Conclusion : Through the direct measurement using the two ion chambers, which is made different wall materials, and computer calculation of isodose distribution using MCNP simulation method, we have found the dose characteristics of low fluence fast neutron beams. If the power supply and the target material, which generate high voltage and current, will be developed and gamma contamination was reduced by lead or bismuth, we think, it may be possible to accelerator-based BNCT.

  • PDF

Off-pump Coronary Artery Bypass Surgery Versus Drug Eluting Stent for Multi-vessel Coronary Artery Disease (다혈관 관상동맥질환에서의 심폐바이패스를 사용하지 않은 관상동맥우회술과 약물용출 스텐트시술)

  • Lee, Jae-Hang;Kim, Ki-Bong;Cho, Kwang-Ree;Park, Jin-Shik;Kang, Hyun-Jae;Koo, Bon-Kwon;Kim, Hyo-Soo;Sohn, Dae-Won;Oh, Byung-Hee;Park, Young-Bae
    • Journal of Chest Surgery
    • /
    • v.41 no.2
    • /
    • pp.202-209
    • /
    • 2008
  • Background: The introduction of Drug Eluting Stents (DES) decreased the number of patients referred for coronary artery bypass grafting (CABG). The impact of DES on CABG (Step 1) was studied and compared with the 1-year outcome after CABG with DES (Step 2). Material and Method: Surgical results for patients who underwent off-pump CABG (OPCAB) before the introduction of DES(n=298) were compared with those who underwent OPCAB after the introduction of DES (n=288) (Step 1). Postoperative 30-day and 1-year results were also compared between the patients who underwent percutaneous coronary intervention (PCI) using DES (n=220) and those who underwent OPCAB (n=255) (Step 2). Result: Since the introduction of DES, the ratio of CABG versus PCI decreased. In the CABG group, the number of high risk patients such as elderly patients (age 62 vs. 64, p=0.023), those with chronic renal failure (4% vs. 9%, p=0.021), calcification of the ascending aorta (9% vs. 15%, p=0.043), or frequency of urgent or emergent operations (12% vs. 22%, p=0.002) increased. However, there were no differences in the cardiac death and graft patency rates between the two groups (step 1). During the one-year follow up period, the rate of target vessel revascularization (12.3% vs. 2.4%, p<0.001) and major adverse cardiac events (MACE: death, myocardial infarct, TVR) were higher in the DES than the CABG group (13.6% vs 4.3%) (stage 2). Conclusion: Introduction of DES decreased the number of patients referred for surgery, and increased the comorbidity in patients who underwent CABG. DES increased the rate of target vessel revascularization, and the occurrence of MACE during the 1-year follow-up. However, there was no difference in the incidence of myocardial infarction and cardiac death between the two groups.

Analysis of Variation for Parallel Test between Reagent Lots in in-vitro Laboratory of Nuclear Medicine Department (핵의학 체외검사실에서 시약 lot간 parallel test 시 변이 분석)

  • Chae, Hong Joo;Cheon, Jun Hong;Lee, Sun Ho;Yoo, So Yeon;Yoo, Seon Hee;Park, Ji Hye;Lim, Soo Yeon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.23 no.2
    • /
    • pp.51-58
    • /
    • 2019
  • Purpose In in-vitro laboratories of nuclear medicine department, when the reagent lot or reagent lot changes Comparability test or parallel test is performed to determine whether the results between lots are reliable. The most commonly used standard domestic laboratories is to obtain %difference from the difference in results between two lots of reagents, and then many laboratories are set the standard to less than 20% at low concentrations and less than 10% at medium and high concentrations. If the range is deviated from the standard, the test is considered failed and it is repeated until the result falls within the standard range. In this study, several tests are selected that are performed in nuclear medicine in-vitro laboratories to analyze parallel test results and to establish criteria for customized percent difference for each test. Materials and Methods From January to November 2018, the result of parallel test for reagent lot change is analyzed for 7 items including thyroid-stimulating hormone (TSH), free thyroxine (FT4), carcinoembryonic antigen (CEA), CA-125, prostate-specific antigen (PSA), HBs-Ab and Insulin. The RIA-MAT 280 system which adopted the principle of IRMA is used for TSH, FT4, CEA, CA-125 and PSA. TECAN automated dispensing equipment and GAMMA-10 is used to measure insulin test. For the test of HBs-Ab, HAMILTON automated dispensing equipment and Cobra Gamma ray measuring instrument are used. Separate reagent, customized calibrator and quality control materials are used in this experiment. Results 1. TSH [%diffrence Max / Mean / Median] (P-value by t-test > 0.05) C-1(low concentration) [14.8 / 4.4 / 3.7 / 0.0 ] C-2(middle concentration) [10.1 / 4.2 / 3.7 / 0.0] 2. FT4 [%diffrence Max / Mean / Median] (P-value by t-test > 0.05) C-1(low concentration) [10.0 / 4.2 / 3.9 / 0.0] C-2(high concentration) [9.6 / 3.3 / 3.1 / 0.0 ] 3. CA-125 [%diffrence Max / Mean / Median] (P-value by t-test > 0.05) C-1(middle concentration) [9.6 / 4.3 / 4.3 / 0.3] C-2(high concentration) [6.5 / 3.5 / 4.3 / 0.4] 4. CEA [%diffrence Max / Mean / median] (P-value by t-test > 0.05) C-1(low concentration) [9.8 / 4.2 / 3.0 / 0.0] C-2(middle concentration) [8.7 / 3.7 / 2.3 / 0.3] 5. PSA [%diffrence Max / Mean / Median] (P-value by t-test > 0.05) C-1(low concentration) [15.4 / 7.6 / 8.2 / 0.0] C-2(middle concentration) [8.8 / 4.5 / 4.8 / 0.9] 6. HBs-Ab [%diffrence Max / Mean / Median] (P-value by t-test > 0.05) C-1(middle concentration) [9.6 / 3.7 / 2.7 / 0.2] C-2(high concentration) [8.9 / 4.1 / 3.6 / 0.3] 7. Insulin [%diffrence Max / Mean / Median] (P-value by t-test > 0.05) C-1(middle concentration) [8.7 / 3.1 / 2.4 / 0.9] C-2(high concentration) [8.3 / 3.2 / 1.5 / 0.1] In some low concentration measurements, the percent difference is found above 10 to nearly 15 percent in result of target value calculated at a lower concentration. In addition, when the value is measured after Standard level 6, which is the highest value of reagents in the dispensing sequence, the result would have been affected by a hook effect. Overall, there was no significant difference in lot change of quality control material (p-value>0.05). Conclusion Variations between reagent lots are not large in immunoradiometric assays. It is likely that this is due to the selection of items that have relatively high detection rate in the immunoradiometric method and several remeasurements. In most test results, the difference was less than 10 percent, which was within the standard range. TSH control level 1 and PSA control level 1, which have low concentration target value, exceeded 10 percent more than twice, but it did not result in a value that was near 20 percent. As a result, it is required to perform a longer period of observation for more homogenized average results and to obtain laboratory-specific acceptance criteria for each item. Also, it is advised to study observations considering various variables.

A Study on the Present Condition and Improvement of Cultural Heritage Management in Seoul - Based on the Results of Regular Surveys (2016~2018) - (서울특별시 지정문화재 관리 현황 진단 및 개선방안 연구 - 정기조사(2016~2018) 결과를 중심으로 -)

  • Cho, Hong-seok;Suh, Hyun-jung;Kim, Ye-rin;Kim, Dong-cheon
    • Korean Journal of Heritage: History & Science
    • /
    • v.52 no.2
    • /
    • pp.80-105
    • /
    • 2019
  • With the increasing complexity and irregularity of disaster types, the need for cultural asset preservation and management from a proactive perspective has increased as a number of cultural properties have been destroyed and damaged by various natural and humanistic factors. In consideration of these circumstances, the Cultural Heritage Administration enacted an Act in December 2005 to enforce the regular commission of surveys for the systematic preservation and management of cultural assets, and through a recent revision of this Act, the investigation cycle has been reduced from five to three years, and the object of regular inspections has been expanded to cover registered cultural properties. According to the ordinance, a periodic survey of city- or province-designated heritage is to be carried out mainly by metropolitan and provincial governments. The Seoul Metropolitan Government prepared a legal basis for commissioning regular surveys under the Seoul Special City Cultural Properties Protection Ordinance 2008 and, in recognition of the importance of preventive management due to the large number of cultural assets located in the city center and the high demand for visits, conducted regular surveys of the entire city-designated cultural assets from 2016 to 2018. Upon the first survey being completed, it was considered necessary to review the policy effectiveness of the system and to conduct a comprehensive review of the results of the regular surveys that had been carried out to enhance the management of cultural assets. Therefore, the present study examined the comprehensive management status of the cultural assets designated by the Seoul Metropolitan Government for three years (2016-2018), assessing the performance and identifying limitations. Additionally, ways to improve it were sought, and a DB establishment plan for the establishment of an integrated management system under the auspices of the Seoul Metropolitan Government was proposed. Specifically, survey forms were administered under the Guidelines for the Operation of Periodic Surveys of National Designated Cultural Assets; however, the types of survey forms were reclassified and further subdivided in consideration of the characteristics of the designated cultural assets, and manuals were developed for consistent and specific information technologies in respect of the scope and manner of the survey. Based on this analysis, it was confirmed that 401 cases (77.0%) out of 521 cases were generally well preserved; however, 102 cases (19.6%) were found to require special measures such as attention, precision diagnosis, and repair. Meanwhile, there were 18 cases (3.4%) of unsurveyed cultural assets. These were inaccessible to the investigation at this time due to reasons such as unknown location or closure to the public. Regarding the specific types of cultural assets, among a total of 171 cultural real estate properties, 63 cases (36.8%) of structural damage were caused by the failure and elimination of members, and 73 cases (42.7%) of surface area damage were the result of biological damage. Almost all plants and geological earth and scenic spots were well preserved. In the case of movable cultural assets, 25 cases (7.1%) among 350 cases were found to have changed location, and structural damage and surface area damage was found according to specific material properties, excluding ceramics. In particular, papers, textiles, and leather goods, with material properties that are vulnerable to damage, were found to have greater damage than those of other materials because they were owned and managed by individuals and temples. Thus, it has been confirmed that more proactive management is needed. Accordingly, an action plan for the comprehensive preservation and management status check shall be developed according to management status and urgency, and the project promotion plan and the focus management target should be selected and managed first. In particular, concerning movable cultural assets, there have been some cases in which new locations have gone unreported after changes in ownership (management); therefore, a new system is required to strengthen the obligation to report changes in ownership (management) or location. Based on the current status diagnosis and improvement measures, it is expected that the foundation of a proactive and efficient cultural asset management system can be realized through the establishment of an effective mid- to long-term database of the integrated management system pursued by the Seoul Metropolitan Government.

Clinical Characteristics of Pleomorphic Carcinoma (다형성 암종의 임상적 고찰)

  • Lee, Deok-Heon;Park, Hoon;Park, Chang-Kwon;Kwon, Kun-Young;Park, Nam-Hee;Choi, Sae-Young;Lee, Kwang-Sook;Yoo, Young-Sun
    • Journal of Chest Surgery
    • /
    • v.36 no.6
    • /
    • pp.397-403
    • /
    • 2003
  • Background: The research sought to identify the clinical features of pleomorphic carcinoma of the lung generally known as a rare subtype in accordance with the lung cancer classification done in 1999 by WHO. Material and Method: 250 cases of surgically resected lung cancers were collected in this hospital from January 1992 to December 2001. This study included 42 cases of pleomorphic carcinoma diagnosed through light microscope and immunohistochemistry. Result: Out of 42 cases, males represented 31, and females 11, the age ranged from 26 to 77. Main clinical symptoms included coughing, hemoptysis, sputum. Diagnoses disclosed the stage as stage la in 3 cases (7%), Ib in 16 (38%), IIa in 1 (2%), IIb in 8 (19%), IIIa in 15 (35%), and IIIb in 1 (2%). Out of these, no lymph node metastasis was represented in 23 cases (54%), while N1 and N2 involving lymph node metastasis was shown 19 cases (46%). A total of 19 patients developed metastasis, comprising the brain in 5 cases (26%), bone in 4 (21%), muscle in 4 (21%), Lymph node in 2 (10%), and 1 liver, ovary, contralateral lung, and adrenal gland, respectively. The size of the tumor ranged from 1 cm to 11 cm, averaging 5.85 cm. Out of the 42 patients, the total two-year and five-year survival rates in accordance with the Kaplan-Meier method represented 26% and 13%, respectively, These figures compared to the corresponding 44% and 34% in cases other than pleomorphic carcinoma from the survey target of 256 cases, proved to be significantly low (p<0.002). No significant difference was found in the survival rates compared between age and tumor size, between stage I and above stage II, and between N0 and above N1. Patients who developed postoperative metastasis all died, and showed significantly low survival rates (p<0.002) compared to those patients without metastasis. Conclusion: With the new diagnosis method of f999 WHO's lung cancer classification applied, pleomorphic carcinoma showed a higher prevalence rate than under previous classifications, their postoperative survival rate was significantly low compared to histologic type of non small cell lung carcinomas.

Reoperations after Fontan Procedures (폰탄 술식 후에 시행한 재수술)

  • Lee, Cheul;Kim, Yong-Jin;Lee, Jeong-Ryul;Rho, Joon-Ryang
    • Journal of Chest Surgery
    • /
    • v.36 no.7
    • /
    • pp.457-462
    • /
    • 2003
  • Background: Surgical results of the Fontan procedures in patients with a single ventricle have improved. As the perioperative mortality continues to decline and late outcome is forthcoming, attention is now being directed toward late complications of the Fontan procedures. We retrospectively analyzed our experience with reoperations after Fontan procedures. Material and Method: Between January 1988 and December 2002, 24 patients underwent reoperations after Fontan procedures. The median age at Fontan procedures and reoperation was 3.3 years and 9.2 years, respectively. Types of initial Fontan procedures were atriopulmonary connection (n=11), lateral tunnel Fontan (n=11), and extracardiac conduit Fontan (n=2). Indications for reoperation included atrioventricular valve regurgitation (n=7), atrial arrhythmia (n=8), Fontan pathway stenosis (n=7), residual right-to-left shunt (n=5), etc. Result: Procedures performed at reoperation included atrioventricular valve replacement (n=6), conversion to lateral tunnel Fontan (n=5), conversion to extracardiac conduit Fontan (n=3), cryoablation of arrhythmia circuit (n=7), etc. There was no operative mortality. There were 2 late deaths. Mean follow-up duration was 2.7$\pm$2.1 years. All patients except two were in NYHA class I at the latest follow-up. Among 8 patients with preoperative atrial arrhythmia, postoperative conversion to normal sinus rhythm was achieved in 7 patients. Conclusion: Reoperations after Fontan procedures could be achieved with low mortality and morbidity. Reoperation may lead to clinical improvement in patients with specific target conditions such as atrioventricular valve regurgitation, refractory atrial arrhythmia, or Fontan pathway stenosis, especially in patients with previous atriopulmonary connection.

Study on Radioactive Material Management Plan and Environmental Analysis of Water (II) Study of Management System in Water Environment of Japan (물 환경의 방사성 물질 관리 방안과 분석법에 관한 연구 (II) 일본의 물 환경 방사성물질 관리 체계에 대한 고찰)

  • Han, Seong-Gyu;Kim, Jung-Min
    • Journal of radiological science and technology
    • /
    • v.38 no.3
    • /
    • pp.305-313
    • /
    • 2015
  • After Fukushima Daiichi nuclear disaster in 2011, study and maintenance of monitoring systems have been made at home and abroad. As concerns about radioactive contamination of water have increased in Korea, update of maintenance of managing radioactive materials in water is being made mainly by Ministry of Environment. In this study, we analysed current state of monitoring system modification in Japan, the country directly involved and neighboring country. According to the result, Japan modified the legislations first. Then Ministry of Education, Culture, Sports, Science and Technology (MEXT) provides theoretical background of radiological monitoring. And Ministry of the Environment actually watches state of water pollution in public waters and underground water. Finally related agencies like local government are monitoring current state of radioactive contamination in water environment. By region, local monitoring stations share the investigation of the whole country. Also, additional monitoring is running around nuclear facilities. After Fukushima disaster, monitoring for area near Fukushima is added. Among the reference levels, management target value of drinking water and tap water is 10 Bq/kg, and those of public water and underground water are 1 Bq/L. Measuring intervals varied from every hour to once a year, regularly or irregularly depending on the investigation. The main measuring items are air dose rate, gross ${\alpha}$, gross ${\beta}$, ${\gamma}$ radionuclide, Cs-134, Cs-137, Sr-89, Sr-90, I-131, and so on. In comparison, regulations about general public water in Korea need to be modified, while those about area near nuclear facility and drinking water are organized well. In future, therefore, domestic system would be expected to be modified with making reference to the guidelines like WHO's one. As good case of applying international guideline to domestic environment, Japanese system could be a reference when general standard of radioactivity in public water is made in Korea.