• Title/Summary/Keyword: Target Impedance

Search Result 83, Processing Time 0.027 seconds

Electrical Variable Capacitor based on Symmetrical Switch Structure for RF Plasma System (대칭적인 스위치 구조 기반 RF 플라즈마 시스템 적용 전기적 가변 커패시터)

  • Min, Juhwa;Chae, Beomseok;Kim, Hyunbae;Suh, Yongsug
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.24 no.3
    • /
    • pp.161-168
    • /
    • 2019
  • This study introduces a new topology to decrease the voltage stress experienced by a 13.56 MHz electrical variable capacitor (EVC) circuit with an asymmetrical switch structure applied to the impedance matching circuit of a radio frequency (RF) plasma system. The method adopts a symmetrical switch structure instead of an asymmetrical one in each of the capacitor's leg in the EVC circuit. The proposed topology successfully reduces voltage stress in the EVC circuit due to the symmetrical charging and discharging mode. This topology can also be applied to the impedance matching circuit of a high-power and high-frequency RF etching system. The target features of the proposed circuit topology are investigated via simulation and experiment. Voltage stress on the switch of the EVC circuit is successfully reduced by more than 40%.

Conduction Noise Absorption by Sn-O Thin Films on Microstrip Lines (마이크로스트립 선로에서 Sn-O 박막의 전도노이즈 흡수 특성)

  • Kim, Sung-Soo
    • Korean Journal of Metals and Materials
    • /
    • v.49 no.4
    • /
    • pp.329-333
    • /
    • 2011
  • To develop wide-band noise absorbers with a special design for low-frequency performance, this study proposes a tin oxide (Sn-O) thin films as the noise absorbing materials in a microstrip line. Sn-O thin films were deposited on polyimide film substrates by reactive sputtering of the Sn target under flowing $O_{2}$ gas, exhibiting a wide variation of surface resistance (in the range of $10^{0}-10^{5}{\Omega}$) depending on the oxygen partial pressure during deposition. The microstrip line with characteristic impedance of $50\Omega$ was used for the measurement of noise absorption by the Sn-O films. The reflection parameter $(S_{11})$ increased with a decrease of surface resistance due to an impedance mismatch at the boundary between the film and the microstrip line. Meanwhile, the transmission parameter $(S_{21})$ diminished with a decrease of surface resistance resulting from an Ohmic loss of the Sn-O films. The maximum noise absorption predicted at an optimum surface resistance of the Sn-O films was about $150{\Omega}$. For this film, greater power absorption is predicted in the lower frequency region (about 70% at 1 GHz) than in conventional magnetic sheets of high magnetic loss, indicating that Ohmic loss is the predominant loss parameter for the conduction noise absorption in the low frequency band.

Pallidotomy Guided by MRI and Microrecording for Parkinson's Disease (파킨슨환자의 자기공명영상과 미세전극기록을 이용한 담창구 파괴술)

  • Lee, Kyung Jin;Son, Hyung Sun;Park, Sung Chan;Cho, Kyung Keun;Park, Hae Kwan;Choi, Chang Rak
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.1
    • /
    • pp.41-46
    • /
    • 2001
  • Objective : The exact position of the lesion during the pallidotomy is critical to obtain the clinical improvement of parkinson's disease without damage to surrounding structure. Ventriculogrphy, CT(computed tomograpy) or MRI(magnetic resonance imaging) have been used to determine the initial coordinates of stereotactic target for pallidotomy. The goal of this study was to determine whether microelectrode recording significantly improves the neurophysiologic localization of the target obtained from MRI. Methods : Twenty patients were studied. They underwent a unilateral pallidotomy. Leksell frame was applied and T1 axial images parallel to the AC-PC(anterior commissure-posterior commissure) plane using a 1.5 Tesla MRI with 3mm slice thickness were obtained. Anteroposterior coordinate of target was chosen at 2mm in front of the midcommissural point and lateral coordinate between 19 and 22mm from the midline. The vertical coordinate was calculated on coronal slice using a fast spin echo inversion recovery sequence(FSEIR) related to the position of the choroidal fissure and ranged over 4-5mm below the AC-PC plane. Confirmation of the anatomical target was done on axial slices using the same FSEIR sequence . Microrecording was done at the pallidum contralateral to the symptomatic side using an electrode with a tip diameter of $1{{\mu}m}$ diameter tip and 1.1-1.4 mOhm impedance at 1000Hz. Electrophysiologic localization of the target was also confirmed intraoperatively by macrostimulation. Results : Microrecording techniques were reliable to define the transition from the base of the pallidum which was characterized by the disappearance of spike activity and by the change of the audible background activity. Signals from high amplitude neurons firing at 200-400Hz were recorded in the pallidal base. X, Y and Z coordinates of target obtained from the MRI were within 1mm from the X, Y, Z coordinates obtained with microrecording in 16 patients (80%), 15 patients(75%), 10 patients(50%) respectively. The difference of Y coordinate between on MRI and on microrecording was 4mm in only one patient. Conclusion : The MRI was accurate to localize the target within 1mm of the error from microrecording target in 70% of the patients. 4mm discrepancy was observed only once. We conclude that MRI alone can be used to determine the target for pallidotomy in most patients. However, microrecording technique can still be extremely valuable in patents with aberrant anatomy or unusual MRI coordinates. We also consider physiologic confirmation of the target using macrostimulation to be mandatory in all cases.

  • PDF

Effect of Deposition Parameter on Ionic Conductivity of RF Magnetron Sputtered Li$_2$O-B$_2$O$_3$-SiO$_2$ Solid Electroiyte Films (RF 마그네트론 스퍼터링법으로 증착된 Li$_2$O-B$_2$O$_3$-SiO$_2$ 계 비정질 박막 고체전해질의 증착변수에 따른 이온전도 특성에 관한 연구)

  • 노남석;권혁상
    • Journal of the Korean institute of surface engineering
    • /
    • v.27 no.2
    • /
    • pp.65-73
    • /
    • 1994
  • Effects of deposition parameter on the ionic conductivity and structural change of the Lithium borosili-cate solid electrolyte films, prepared by rf sputtering using 7$LI_2O-3B_2O_3-1SiO_2$ single phase target and also a mosaic target enriched with $LI_2O$, were analyzed by measuring AC impedance and IR absorption spectra for the films. Thed solid electrolyte film deposited from the single phase target exhibited very low ionic conductivi-ty of $10^{-10}{\Omega}^{-1}cm{-1}$ at room temperature, a result of low $Li^+$ ion content(7.52 at%) in the film. The $Li^+$ con-ductivity for the films deposited from the mosaic target, however, significantly increased to $10^{-7}{\Omega}^{-1}cm{-1}$ due to both an increased $Li^+$content (14.75 at %) and a structural change of the films. The increased ionic conduc-tivity of the film appears to be associated with an easiness of ionic mobility by structural change of glassy film from a some close packed network structure to a open one. These structural changes of film were found to be closely related to the increase in the peak intensity at~$960cm^{-1}$ of IR absorption spectra for the glassy films. With increasing either argon pressure from 3 to 21 mtorr or rf power from 2 to 3 W/$cm^2$, the $Li^+$ conduc-tivity for the films significantly increased to an order of $10^{-6}{\Omega}^{-1}cm{-1}$ due to an increase in openness of film structure, as confirmed by both an increase in the IR absorption peak intensity at ~$960cm^{-1}$ and a resultant reduction of activation energy for mobility of $Li^+$ ion.

  • PDF

Study on Real-time Parallel Processing Simulator for Performance Analysis of Missiles (유도탄 성능분석을 위한 실시간 병렬처리 시뮬레이터 연구)

  • Kim Byeong-Moon;Jung Soon-Key
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.11 no.1
    • /
    • pp.84-91
    • /
    • 2005
  • In this paper, we describe the real-time parallel processing simulator developed for the use of performance analysis of rolling missiles. The real-time parallel processing simulator developed here consists of seeker emulator generating infrared image signal on aircraft, real-time computer, host computer, system unit, and actual equipments such as auto-pilot processor and seeker processor. Software is developed from mathematic models, 6 degree-of-freedom module, aerodynamic module which are resided in real-time computer, and graphic user interface program resided in host computer. The real-time computer consists of six TIC-40 processors connected in parallel. The seeker emulator is designed by using analog circuits coupled with mechanical equipments. The system unit provides interface function to match impedance between the components and processes very small electrical signals. Also real launch unit of missiles is interfaced to simulator through system unit. In order to apply the real-time parallel processing simulator to performance analysis equipment of rolling missiles it is essential to perform the performance verification test of simulator.

Tunnel Diode Oscillator with a Moving Target as a Self-excited Mixer (이동물체 탐색을 위한 터넬다이오드 백여믹서)

  • Lee, Jong-Gak;Sim, Su-Bo;Yun, Hyeon-Bo
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.11 no.1
    • /
    • pp.40-46
    • /
    • 1974
  • This paper deals with the self-excited mixer using tunnel diode oscillator operated as a microwave source and Doppler signal detector. The system impedance, the oscillation condition and the frequency conversion theory including moving target are investigated. The oscillating frequency and the output of tunnel diode oscillator are 2.035 GHz and 0.1 mW. The input signal frequency which is equivalent to Doppler signal is lower than tunnel diode oscillator frequency by 125 MHz. TDe conversion loss has been investigated as a functicn of input signal level. This loss is greater than 67 db for the large pump mode.

  • PDF

Optimal Structural Design of a Tonpilz Transducer Considering the Characteristic of the Impulsive Shock Pressure (충격 특성을 고려한 Tonpilz 변환기의 최적구조 설계)

  • Kang, Kook-Jin;Roh, Yong-Rae
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.21 no.11
    • /
    • pp.987-994
    • /
    • 2008
  • The optimal structure of the Tonpilz transducer was designed. First, the FE model of the transducer was constructed, that included all the details of the transducer which used practical environment. The validity of the FE model was verified through the impedance analysis of the transducer. Second, the resonance frequency, the sound pressure, the bandwidth, and the impulsive shock pressure of the transducer in relation to its structural variables were analyzed. Third, the design method of $2^n$ experiments was employed to reduce the number of analysis cases, and through statistical multiple regression analysis of the results, the functional forms of the transducer performances that could consider the cross-coupled effects of the structural variables were derived. Based on the all results, the optimal geometry of the Tonpilz transducer that had the highest sound pressure level at the desired working environment was determined through the optimization with the SQP-PD method of a target function composed of the transducer performance. Furthermore, for the convenience of a user, the automatic process program making the optimal structure of the acoustic transducer automatically at a given target and a desired working environment was made. The developed method can reflect all the cross-coupled effects of multiple structural variables, and can be extended to the design of general acoustic transducers.

Electrical Impedance Tomography for Material Profile Reconstruction of Concrete Structures (콘크리트 구조의 재료 물성 재구성을 위한 전기 임피던스 단층촬영 기법)

  • Jung, Bong-Gu;Kim, Boyoung;Kang, Jun Won;Hwang, Jin-Ha
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.32 no.4
    • /
    • pp.249-256
    • /
    • 2019
  • This paper presents an optimization framework of electrical impedance tomography for characterizing electrical conductivity profiles of concrete structures in two dimensions. The framework utilizes a partial-differential-equation(PDE)-constrained optimization approach that can obtain the spatial distribution of electrical conductivity using measured electrical potentials from several electrodes located on the boundary of the concrete domain. The forward problem is formulated based on a complete electrode model(CEM) for the electrical potential of a medium due to current input. The CEM consists of a Laplace equation for electrical potential and boundary conditions to represent the current inputs to the electrodes on the surface. To validate the forward solution, electrical potential calculated by the finite element method is compared with that obtained using TCAD software. The PDE-constrained optimization approach seeks the optimal values of electrical conductivity on the domain of investigation while minimizing the Lagrangian function. The Lagrangian consists of least-squares objective functional and regularization terms augmented by the weak imposition of the governing equation and boundary conditions via Lagrange multipliers. Enforcing the stationarity of the Lagrangian leads to the Karush-Kuhn-Tucker condition to obtain an optimal solution for electrical conductivity within the target medium. Numerical inversion results are reported showing the reconstruction of the electrical conductivity profile of a concrete specimen in two dimensions.

Irradiation of Intense Characteristic X-rays from Weakly Ionized Linear Plasma

  • Sato, Eiichi;Hayasi, Yasuomi;Tanaka, Etsuro;Mori, Hidezo;Kawai, Toshiaki;Takayama, Kazuyoshi;Ido, Hideaki
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.396-399
    • /
    • 2002
  • Intense quasi-monochromatic x-ray irradiation from the linear plasma target is described. The plasma x-ray generator employs a high-voltage power supply, a low-impedance coaxial transmission line, a high-voltage condenser with a capacity of about 200 nF, a turbo-molecular pump, a thyristor pulse generator as a trigger device, and a flash x-ray tube. The high-voltage main condenser is charged up to 55 kV by the power supply, and the electric charges in the condenser are discharged to the tube after triggering the cathode electrode. The x-ray tube is of a demountable triode that is connected to the turbo molecular pump with a pressure of approximately 1 mPa. As electron flows from the cathode electrode are roughly converged to the molybdenum target by the electric field in the tube, the weakly ionized plasma, which consists of metal ions and electrons, forms by the target evaporating. In the present work, the peak tube voltage was almost equal to the initial charging voltage of the main condenser, and the peak current was about 20 kA with a charging voltage of 55 kV. When the charging voltage was increased, the linear plasma x-ray source grew, and the characteristic x-ray intensities of K-series lines increased. The quite sharp lines such as hard x-ray lasers were clearly observed. The quasi-monochromatic radiography was performed by a new film-less computed radiography system.

  • PDF

Analysis of Energy Conversion Efficiency in Micro Power Generation using Vibrating Piezoelectric Cantilever (압전빔의 진동을 이용한 마이크로 동력원의 에너지 변환 해석)

  • Lee, Heon-Ju;Chang, Young-Soo;Lee, Yoon-Pyo
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.3365-3370
    • /
    • 2007
  • We developed micro power generation system using piezoelectric materials. In our system, the ambient vibrating energy is converting to electric energy by deflection of piezoelectric beams. The system consists of energy generating parts, converting enhancement parts, electric regulation and charging parts, and interface with small-energy-consuming mobile devices. The geometry of piezoelectric beams, the source of vibrating energy, and the electric load of target application determine the characteristics of generating electric power, such as impedance, voltage, current and power density. Therefore, we made a model for analysis of generating power with given information such as piezoelectric materials, geometry, vibration type, and mass. With this model, we can calculate capacitance of piezoelectric beams, generating voltage, current, and power. To obtain maximum energy transfer efficiency, we approached this study in the view of material, electrical, and mechanical engineering

  • PDF