• Title/Summary/Keyword: Tank Container

Search Result 92, Processing Time 0.031 seconds

A Study and Design on Tank Container for Fuel Tank of LNG Fueled Ship (LNG 연료 추진선의 연료 탱크로서 탱크컨테이너의 적용성 연구 및 구조설계)

  • Kim, Tae-Woo;Suh, Yong-Suk;Jang, Ki-Bok;Chun, Min-Sung;Lee, Kang-Dae;Cha, Kyong-Ho
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.49 no.6
    • /
    • pp.504-511
    • /
    • 2012
  • The objective of this study is to investigate tank container to be used as fuel tank for LNG fueled ship. Feasibility of tank container to the fuel tank of LNG fueled ship is addressed and the advantage of tank container as fuel tank of ship is investigated. Conceptual configuration of the tank container is designed as well as structural analyses based on finite element method are carried out to meet the design regulation suggested by shipping register. Static loading is considered by structural analysis and impact test is performed. It is necessary to require SRS(shock response spectrum) in order to investigate structural safety which can meet.

Internal Pressure Variation Analysis and Actual Holding Time Test on ISO LNG Tank Container (LNG 탱크 컨테이너의 내부압력 변화 분석 및 실제 홀딩타임 측정)

  • Ryou, Young-Don;Lee, Jin-Han;Jo, Young-Do;Oh, Young-Sam;Cha, Kyong-Ho
    • Journal of the Korean Institute of Gas
    • /
    • v.17 no.6
    • /
    • pp.1-7
    • /
    • 2013
  • Internal pressure variation analysis and actual holding time test on ISO LNG tank containers which were made in Korea for the first time according to the special notification of ISO tank container manufacture have been conducted during the transport demonstration projects of the tank containers by tractor, train and ship. The internal pressure of the LNG tank container increased rapidly after LNG filling and dropped during moving the container. However, it was stabilized as time passed and followed the liquid-vapor equilibrium graph. In addition, actual holding time of the tank container was more than 20 days which was satisfied with the special notification of LNG tank container manufacture.

A Study on Improvement of Operation Process and Management Plan for Tank Container (Tank 컨테이너 운영프로세스 및 관리방안 개선에 관한 연구)

  • Park, Dong-Jin;Kim, Hwan-Seong
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2019.11a
    • /
    • pp.191-192
    • /
    • 2019
  • The transport market has continued to change to provide services for each cargo. Currently, tank containers are widely used for the transport of liquids, and the tank container transportation market is continuously growing. Accordingly, the demand for handling for tank containers is also increasing. The purpose of this study is to suggest the improvement of transportation process and management method based on the case analysis of the current tank container transportation market. Therefore, this is paper suggests that an integrated system is needed to eliminate the period of information disconnection, secure information continuity, and improve the efficiency of managing dangerous goods.

  • PDF

Consideration of Structural Damage of Fresh Water Tank for 2,600 TEU Container Vessel (2,600 TEU Container Vessel 의 Fresh Water Tank 구조손상 사례 고찰)

  • Shin Sung-Kwang;Ahn Hyung-Joon;Choi Eui-keol;Koh Myeong-Seob;Leem Hyo-Kwan
    • Special Issue of the Society of Naval Architects of Korea
    • /
    • 2005.06a
    • /
    • pp.216-221
    • /
    • 2005
  • Many tanks such as a fresh water tank, an aft peak tank and oil tanks are arranged in the engine room and aft part areas of the ship. By added mass effect of the fluid inside the tanks, the natural frequency will be changed according to filling height of the tank. For this reason, there is possibility of occurrence of excessive vibration by resonance between natural frequencies of local structure and excitation frequencies of the propeller or main engine. Therefore, calculation of natural frequencies is required for structure for many types of tank which are contacting with water or oil to consider added mass effect for anti-resonance design at design stage. In this study, a case of structure damage on the fresh water tank for 2600 TEU container vessel is introduced. In addition, natural frequency analysis and vibration measurement have been performed to investigate vibration characteristics for excessive vibration control.

  • PDF

Study on the numerical simulation of bird strike for composite container of external auxiliary fuel tank for rotorcraft (회전익항공기 외부 보조연료탱크용 복합재 컨테이너 조류충돌 수치모사 연구)

  • Kim, Hyun-Gi;Kim, Sungchan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.7
    • /
    • pp.709-713
    • /
    • 2017
  • In urgent situations such as crashes, the integrity of an aircraft's fuel tank is directly related to the survivability of the crew. Thus, an external auxiliary fuel tank should be robust against bird strikes. In this study, a numerical analysis was carried out using impact analysis software to analyze the influence of bird strike on a composite container for an external auxiliary fuel tank. The structure was modeled as a shell element, and the fluid and bird were modeled by the particle method. The behavior of the internal fluid was also examined. The maximum stress, deformation, and strain of the composite container were also calculated.

Analytical comparison of structural changes of plastic cell-based therapeutic drug storage containers when exposed to cryogenic environments (플라스틱 세포치료제 보관용기의 극저온 환경 노출 시 구조적 변화에 대한 해석적 비교)

  • Park, Jeong-Yeon;Lee, Dong-Mok;Lee, Jienny;Lee, Sun-ray;Yoon, Gil-Sang
    • Design & Manufacturing
    • /
    • v.14 no.2
    • /
    • pp.1-6
    • /
    • 2020
  • Recently, research and commercialization related to the field of cell-based therapeutic drug development has been actively conducted. In order to maintain cell viability and prevent contamination, refrigeration preservation devices, such as CRF (controlled rate freezer) or vapor type LN2 tanks have been developed. On the other hand, the storage container for liquid nitrogen tanks currently on sale minimizes the flow structure to prevent structural defects when stored in a liquid nitrogen tank having a high thermal conductivity than vapor nitrogen. If the cell-based treatment drug is stored in the gaseous LN2 tank as it is, the cell survival after thawing is greatly reduced. It was estimated that the existing storage container structure was a factor that prevented the rapid entry and circulation of gaseous nitrogen into the container. Therefore, this study intends to propose a new supercellular storage container model that can maintain the mechanical strength while maximizing the fluid flow structure. To this end, we estimated that the structural change of the storage container effects on the equivalent stress formed around the through-holes of them when exposed to a cryogenic environment using thermal-structural coupled field analysis. As a result of storage experiments in the gas phase tank of the cell-based therapeutic agent using the developed storage container, it was confirmed that the cell growth rate was improved from 66% to 77%, which satisfied the transportation standards of the FDA(Food and Drug Administration) cell-based therapeutic agent.

A Study on the Static Structural Strength Evaluation of 53ft Liquefied Natural Gas Tank Container (53ft 액화천연가스 탱크 컨테이너의 정적 구조 강도 평가에 관한 연구)

  • Chunsik Shim;Hokyung Kim;Daseul Jeong;Deokyeon Lee;Kangho Kim;Minsuk Kim;Sungkuk Wi;Heechang Noh;Youngbin Kwon;Changseok Hong;Kim Byeonghwa;Cheonghak Kim
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.60 no.4
    • /
    • pp.278-287
    • /
    • 2023
  • This study aims to analyze and evaluate the structural strength of a 53ft Liquefied Natural Gas (LNG) tank container according to International Organization for Standardization (ISO) 1496-3, amidst growing global demand for LNG transportation. The research was conducted in two main stages: structural analysis using Finite Element Analysis (FEA) under various load conditions, and structural strength tests following ISO 1496-3 test procedures. The structural analysis was performed considering different loading conditions to assess the structural safety of the tank container. Calculated stresses were compared with allowable stress under specified load conditions. The structural strength tests were conducted at Mokpo National University's Subsea Umbilical cable Riser Flowline R&D Center, which provided a suitable testing environment. The study found that calculated stresses met the allowable stress under specified load conditions, confirming the structural safety of the tank container. Additionally, the maximum deformation and permanent deformation satisfied the design criteria for all test cases, indicating the container's structural strength meets requirements. The research also contributed valuable data for future structural strength tests of similar products and facilitated the development of safe and efficient LNG transportation solutions by developing effective test procedures in accordance with ISO 1496-3 standards.

A Conceptual Design and Structural Efficiency Evaluation of 20ft Container Shape CNG Tank (20피트 콘테이너형 압축천연가스탱크의 개념설계 및 구조효율성 평가)

  • Kim, Young-Hun;Kim, Jung-Yeob;Lee, Jae-Wook;Song, Jae-Young
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.42 no.2 s.140
    • /
    • pp.142-150
    • /
    • 2005
  • Recently, the gas transportation system for CNG(Compressed Natural Gas) has been developed and several innovative approaches are presented from the aspects of commercial demand. In this study, a new type of 20ft container shape CNG tank with two and four cylinder intersections by using the intersecting spheres has been proposed. And the structural analysis of CNG tank with Mildsteel, API High Tensile Steel, Al-alloy and FRP has been carried out to compare the different types of pressure vessels of materials used. The analysis result shows that the proposed intersectional cylindrical type of CNG tank can be applied to the gas transportation system. And further study on the commercial analysis and associated equipments should be carried out for the practical applications.

Designing a Hydro-Structural Ship Model to Experimentally Measure its Vertical Bending and Torsional Vibrations

  • Houtani, Hidetaka;Komoriyama, Yusuke;Matsui, Sadaoki;Oka, Masayoshi;Sawada, Hiroshi;Tanaka, Yoshiteru;Tanizawa, Katsuji
    • Journal of Advanced Research in Ocean Engineering
    • /
    • v.4 no.4
    • /
    • pp.174-184
    • /
    • 2018
  • We herein propose a new design procedure of a flexible container ship model where the vertical bending and torsional vibration modes are similar to its prototype. To achieve similarity in torsional vibration mode shapes, the height of the shear center of the model must be located below the bottom hull, similar to an actual container ship with large opening decks. Therefore, we designed a ship model by imparting appropriate stiffness to the hull, using urethane foam without a backbone. We built a container ship model according to this design strategy and validated its dynamic elastic properties using a decay test. We measured wave-induced structural vibrations and present the results of tank experiments in regular and freak waves.

Collision Analysis of Longitudinal Bulkhead of Container/RO-RO Ship with Trailer (컨테이너/로로 선 종격벽의 트레일러 충돌해석)

  • Kang, Myung-Hun;Song, In;Lee, Sang-Kyun;Kim, Sang-Kon;Cho, Sang-Rai
    • Special Issue of the Society of Naval Architects of Korea
    • /
    • 2013.12a
    • /
    • pp.13-20
    • /
    • 2013
  • In this paper, a collision accident of a container/Ro-Ro ship was numerically analyzed. A container trailer collided with a longitudinal bulkhead of the ship in the accident, which constituted a longitudinal wall of a heavy fuel oil tank. Due to the accident, the bulkhead plate was ruptured and the heavy fuel oil spilled out of the tank. The detailed information regarding the collision velocity and the mass of the trailer was not provided. Therefore, several collision accident scenarios were constructed based upon the arrangement of the ramp way. Each collision accident scenario was analyzed to predict the extents of damage using a commercial numerical package, ABAQUS. Based on the analysis results it is proposed how to minimize the extents of damage. Through the investigations performed in this study it was found that the understandings of various damages due to collision accidents and the developments of structural design guidance against collision are necessary for the betterment of Container/RO-RO ships' performance.

  • PDF