• Title/Summary/Keyword: Tag Sensitivity

Search Result 36, Processing Time 0.021 seconds

Design of a Flexible Planar RFID Tag Antenna with Low Performance Degradation from Nearby Target Objects

  • Choo, Jae-Yul;Ryoo, Jeong-Ki;Choo, Ho-Sung
    • Journal of electromagnetic engineering and science
    • /
    • v.11 no.1
    • /
    • pp.1-4
    • /
    • 2011
  • In this letter, we propose a novel tag antenna that has low performance degradation with nearby dielectric material. We obtained a stable reading performance and a broad matching bandwidth on nearby dielectric materials by employing a T-matching network with thick line width and capacitively slot-loaded arms. We then built the proposed antenna and measured the tag sensitivity to examine the reading characteristics with nearby dielectric materials. The measured results clearly demonstrate stable tag sensitivity with various nearby dielectric materials, such as foam, acrylic-plastic, glass, and ceramic plates. To more closely observe the antenna characteristics with nearby dielectric materials, we also examined the impedance variation and surface current distribution with respect to the dielectric constant of nearby target objects, which ranged from $1{\times}{\varepsilon}_0$ to $16{\times}{\varepsilon}_0$.

Tag Mis-recognition Detection using RFID Tag Sensitivity in Logistics System (물류 시스템에서 RFID 태그 수신감도를 이용한 태그 오인식 검출)

  • Kim, Youngmin;Kang, Euisun
    • The Journal of the Korea Contents Association
    • /
    • v.15 no.8
    • /
    • pp.9-17
    • /
    • 2015
  • One of RFID features is that each RFID tag has a unique identifying code. Logistic System utilizes RFID tag as location tracing, understanding stock or etc. On the other hand, there is a problem of overall lower recognition rate by getting the information of non-mobility tags with no need for reading. To solve this problem, we trace and analyze variation of moving and moveless RFID tag sensitivity by the hour. In analyzed data, we verify that tag sensitivity of mobile RFID is gradually increase while non-mobility tag has same intensity value. In order to detect mobile tag, we generate a function using Matlab with analyzed data and separate moving tags from non-mobility tags by software. As a result, we can confirm that non-mobility tags are detected by software and recognition rate of RFID tag is improved by separating moveless tag.

Passive UHF RFID Propagation Characteristics and Reconsideration of Link budget on Practical Communication Area (수동형 UHF RFID 인터페이스에 대한 Link budget의 재해석 및 전파 환경 요소 분석)

  • Jung, Jin-Woo;Park, Kyoung-Tae;Roh, Hyoung-Hwan;Park, Jun-Seok;Kim, Hyeong-Seok
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2008.08a
    • /
    • pp.469-472
    • /
    • 2008
  • In this paper, we discuss the recent trends on the passive UHF RFID tag chip design techniques and several important system parameters. We also summarize link budget studies on both conventional and modem UHF RFID communications. The paper highlights the reverse link limited case, which has known to be the minor concern if reader continuous wave (CW) can reach the tag in sufficient level. This makes sense when the tag sensitivity is rather high (over 10-12${\mu}W$); however, since the tag chip fabrication technologies have been developed by time, the tag chip threshold levels are now less-dominant in determining link margin. If the tag limitation can be alleviated, the forward link limited case can be resolved; thus, we rather focus on the path-loss problem. Since the path-losses are still exist in both forward and reverse links, and it can be doubled while CW travels the reader-tag-reader path because forward link and reverse link are on the same distance. Consider if reader receiver sensitivity is very high in the worst case. In this case, weaken tag response (i.e., backscatters) cannot reach the level that reader receiver can process tag data; bit-error rate can be higher. Overall, backscatter levels should be high enough so that reader receiver can correctly function. After discussing link budget, we carried out practical measurements on fading effects between two circularly polarized UHF RFID antennas in a small scale area.

  • PDF

A Design of RFID Tag Antenna with High Sensitivity for Car Side Mirror (사이드 미러용 고감도 RFID 태그 안테나의 설계)

  • Han, Seung-Mok;Kim, Min-Seong;Min, Kyeong-Sik
    • Journal of Navigation and Port Research
    • /
    • v.32 no.10
    • /
    • pp.793-798
    • /
    • 2008
  • This paper presents a design of RFID(Radio Frequency Identification} tag antenna which has high sensitivity for car side mirror. A proposed tag antenna ($154\;mm{\times}66\;mm{\times}1;mm$) resonants at 900 MHz and has a wide bandwidth of 690 MHz($490\;MHz{\sim}1180\;MHz$). The measured gain and readable range of tag antenna are 5.8 dBd and 10 m, respectively. Radiation pattern and readable range of proposed tag antenna located on inside of a side mirror including a car body are measured at anechoic chamber. It has been confirmed that the readable range in the vicinity of $90^{\circ}$ has been expanded about 1.5 m by comparison with one of proposed tag antenna without of car body. Good performance of the proposed tag antenna was observed and proved by comparison of measured results of commercial tag antenna.

Impedance and Read Power Sensitivity Evaluation of Flip-Chip Bonded UHF RFID Tag Chip (플립-칩 본딩된 UHF RFID 태그 칩의 임피던스 및 읽기 전력감도 산출방법)

  • Yang, Jeenmo
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.4
    • /
    • pp.203-211
    • /
    • 2013
  • UHF RFID tag designers usually ndde the chip impedance and read power sensitivity value obtained when a tag chip is mounted on a chip pad. The chip impedance, however, is not able to be supplied by chip manufacturer, since the chip impedance is varied according to tag designs and fabrication processes. Instead, the chip makers mostly supply the chip impedances measured on the bare dies. This study proposes a chip impedance and read power sensitivity evaluation method which requires a few simple auxiliary and some RF measuring equipment. As it is impractical to measure the chip impedance directly at mounted chip terminals, some form test fixture is employed and the effect of the fixture is modeled and de-embeded to determine the chip impedance and the read power sensitivity. Validity and accuracy of the proposed de-embed method are examined by using commercial RFID tag chips as well as a capacitor and a resistor the value of which are known.

Performance of the xTAG$^{(R)}$ Gastrointestinal Pathogen Panel, a Multiplex Molecular Assay for Simultaneous Detection of Bacterial, Viral, and Parasitic Causes of Infectious Gastroenteritis

  • Claas, Eric C.;Burnham, Carey-Ann D.;Mazzulli, Tony;Templeton, Kate;Topin, Francois
    • Journal of Microbiology and Biotechnology
    • /
    • v.23 no.7
    • /
    • pp.1041-1045
    • /
    • 2013
  • The xTAG$^{(R)}$ Gastrointestinal Pathogen Panel (GPP) is a multiplexed molecular test for 15 gastrointestinal pathogens. The sensitivity and specificity of this test were assessed in 901 stool specimens collected from pediatric and adult patients at four clinical sites. A combination of conventional and molecular methods was used as comparator. Sensitivity could be determined for 12 of 15 pathogens and was 94.3% overall. The specificity across all 15 targets was 98.5%. Testing for the pathogen identified was not requested by the physician in 65% of specimens. The simultaneous detection of these 15 pathogens can provide physicians with a more comprehensive assessment of the etiology of diarrheal disease.

Performance Improvement in Passive Tag Based RFID Reader (수동형 태그 기반 RFID 리더기의 성능 개선)

  • Rhee, Seung-Hak;Chun, Jong-Hun;Park, Jong-An
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.31 no.11A
    • /
    • pp.1159-1166
    • /
    • 2006
  • In this paper, we have designed a RFID reader receiver system for improving the performance of the passive Tag based 9$'908.5{\sim}914MHz'$ RFID reader, and analyzed the system performance according to the frequency, the reader, and tag properties. The commercial receive system causes a loss in sensitivity because of 24 capacitors and 6 inductors. So we have designed an improved system using a circulator, LNA and a SAW filter. The experimental results show that the use of a circulator to separate the Tx/Rx paths eliminates interference, the LNA improves the sensitivity of the Rx module and SAW filter eliminates the noise and spurious components in the received signal.

Vulnerability Assessment of Forest Distribution by the Climate Change Scenarios (기후변화 시나리오에 따른 산림분포 취약성 평가)

  • Lee, Sangchul;Choi, Sungho;Lee, Woo-Kyun;Park, Taejin;Oh, Suhyun;Kim, Su-Na
    • Journal of Korean Society of Forest Science
    • /
    • v.100 no.2
    • /
    • pp.256-265
    • /
    • 2011
  • This study was aiming at assessing the vulnerability of forest distribution by the A2 and B1 climate change scenarios of Intergovernmental Panel on Climate Change (IPCC). The vulnerability of forest distribution was assessed using its sensitivity and adaptation to climate change with the help of the simulations of Korean-specific forest distribution model, so-called the Thermal Analogy Group (TAG), and the Plant Functional Type (PFT) defined in the HyTAG (Hydrological and Thermal Analogy Groups) model. As a result, the vulnerable area occupied 30.78% and 2.81% of Korea in A2 and B1 scenario, respectively. When it comes to the administrative districts, Pusan in A2 and Daegu in B1 appeared the most vulnerable area. This study would be employed into preparation of adaptative measures for forest in future in terms of using climate change scenarios reflecting different future development conditions.

Development of Batteryless SAW-based Integrated Microsensor and Wireless Measurement Technique (무전지 SAW 기반 마이크로 통합센서 및 무선 측정기술 개발)

  • Oh, Hae-Kwan;Kim, Tae-Hyun;Wang, Wen;Yang, Sang-Sik;Lee, Kee-Keun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.8
    • /
    • pp.1430-1435
    • /
    • 2007
  • We developed a 440MHz surface acoustic wave (SAW) microsensor integrated with pressure-temperature sensors and ID tag. Two piezoelectric substrates were bonded, in which ${\sim}150\;{\mu}m$ cavity was structured. Four sides were completely sealed by JSR photoresist (PR). Pressure sensor was placed on the top substrate, whereas ill tag and temperature sensor were placed on the bottom substrate. Using network analyzer, the developed microsensor was wirelessly tested. Sharp reflection peaks with high S/N ratio, small signal attenuation, and small spurious peaks were observed. All the reflection peaks were well matched with the coupling of mode (COM) simulation results. With a 10mW RF power from the network analyzer, a ${\sim}1$ meter readout distance was observed. Eight sharp ON reflection peaks were observed for ID tag. Temperature sensor was characterized from $20^{\circ}C$ to $200^{\circ}C$. A large phase shift per unit temperature change was observed. The evaluated sensitivity was ${\sim}10^{\circ}/^{\circ}C$.