• Title/Summary/Keyword: TOP

Search Result 13,047, Processing Time 0.038 seconds

A Diagnostic Technique for Distribution Transformers using Top Oil Temperature (최상부 유온을 이용한 배전용 변압기의 진단 기법)

  • Choe, Do-Hyeok;Yun, Yong-Han;Min, Gyeong-Rae;Kim, Jae-Cheol
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.49 no.5
    • /
    • pp.242-251
    • /
    • 2000
  • In this paper, we argued the possibility of the diagnostic technique for distribution transformers using the top oil temperature rising above the ambient temperature. The proposed diagnostic technique used the reference top oil temperature rising at rated current. We determined the emergency value of the transformer using the limitation of the top oil temperature rising and calculated the loss of life. The top oil temperature rises because of the load currents. In this point, the proposed diagnostic technique was explained. The proposed system measures the load current, top oil temperature and ambient temperature. With the diagnostic device, we tested the top oil temperature rising of t재 transformers. Then the loss of life was calculated by the top oil temperature.

  • PDF

A Study on the Construction Process Management of the Top-Down Construction Method (Top-Down 공사의 공정관리 방법 연구)

  • Kang Hyun-Jung;Rhim Hong-Chul;Lee Ghang;Yun Dae-Jung;Kim Sang-Il
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2006.05a
    • /
    • pp.133-136
    • /
    • 2006
  • The top-down construction method is an excavation and substructure construction method by excavating earth and building slabs from the ground level to the bottom of a building. The top-down method can be categorized into several types by its process and other technical details. Some of commonly used top-down methods in Korea today are S.O.G., N.S.T.D., and S.P.S. Among these, one method is chosen depending on construction field conditions, cost, construction time and so on. This study explores several factors that may affect the selection of a top-down method. This paper reports preliminary survey results with 54 top-down construction experts and comparison results of 5 top-down construction sites.

  • PDF

A Cluster-Based Top-k Query Processing Algorithm in Wireless Sensor Networks (무선 센서 네트워크에서 클러스터 기반의 Top-k 질의 처리)

  • Yeo, Myung-Ho;Seong, Dong-Ook;Yoo, Jae-Soo
    • Journal of KIISE:Databases
    • /
    • v.36 no.4
    • /
    • pp.306-313
    • /
    • 2009
  • Top-k queries are issued to find out the highest (or lowest) readings in many sensor applications. Many top-k query processing algorithms are proposed to reduce energy consumption; FILA installs a filter at each sensor node and suppress unnecessary sensor updates; PRIM allots priorities to sensor nodes and collects the minimal number of sensor reading according to the priorities. However, if many sensor reading converge into the same range of sensor values, it leads to a problem that many false positives are occurred. In this paper, we propose a cluster-based approach to reduce them effectively. Our proposed algorithm operates in two phases: top-k query processing in the cluster level and top-k query processing in the tree level. False positives are effectively filtered out in each level. Performance evaluations show that our proposed algorithm reduces about 70% false positives and achieves about 105% better performance than the existing top-k algorithms in terms of the network lifetime.

Influence of loading and unloading of hydraulic support on the caving property of top coal

  • Huayong Lv;Fei Liu;Xu Gao;Tao Zhou;Xiang Yuan
    • Steel and Composite Structures
    • /
    • v.48 no.1
    • /
    • pp.103-111
    • /
    • 2023
  • The caving property of top coal is a key factor to the success of top coal caving mining. The influence law of cyclic loading and unloading of hydraulic support on top coal caving is of great significance to improve the recovery rate of top coal. The similar simulation methods were used to study the dynamic evolution of the top coal cracks under the multi-cycle action of the support, and the parameters of top coal cracks were analyzed quantitatively in this paper. The results show that the top coal cracks can be divided into horizontal cracks and vertical cracks under the cyclic loading and unloading of the support. With the increase of the times of the support cycles loading and unloading, the load on the support decreases, the fractal dimension of the cracks increases, the number and total length of the top coal cracks increases, and the top coal caving is getting better. With the increase of the times of multi-cycle loading and unloading, the fractal dimension, total crack length and crack rate of top coal show a trend of rapid increase first and then increase slowly. Both the total length of the top coal cracks and the crack rate basically show linear growth with the change of the fractal dimension. The top coal caving can be well improved and the coal resource recovery rate increased through the multi-cycle loading and unloading.

Studies on the Root System of Soybeans I. Relations between the top and the root (대두의 근계에 관한 연구 제 1 보 지상부와 근계와의 관계)

  • Kwon-Yawl Chang
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.13
    • /
    • pp.77-81
    • /
    • 1973
  • The experiment was carried out to make clear the root characters and relationships among some quantitative characters of soybeans. The results obtained are summarized as follows: 1. Stem diameter was shown the greater growing in thickness after one month from sowing than the earlier stage, and the greater growing was shown in fertile bed soil than in sand soil. 2. The elongation of plant top in soybean plant was also shown the greater rate in bed soil than in sand soil 3. The length of plant root was longer than the length of plant top in the earlier stage of growing, and the length of root was much greater in sand soil than in fertile bed soil. 4. Weight of plant top was shown more in bed soil than in sand soil, but this tendency was shown more greater rate in the length of plant top than in weight of plant top. 5. Weight of root was more compared with weight of plant top in the earlier stage of growth, and also more greater rate was shown in sand soil than in fertile bed soil. 6. Highly significant correlations were shown among five quantitative characters, namely stem diameter, length of top, weight of top, length of root and weight of root, etc.

  • PDF

Behavior of Floating Base Plate by Stress Delivery Mechanism (부양형 팽이기초의 하중전달 메커니즘에 따른 거동)

  • Chung, Jin-Hyuck;Jung, Hye-Kwun;Lee, Song
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.14 no.2
    • /
    • pp.137-144
    • /
    • 2010
  • Up to now, common studies of top base have concentrated upon bearing capacity and settlement by in-situ loading test in Japan and Korea. But most of all preceding study for top base must analyze how to deliver overburden loading on bottom of foundation. Therefore, in this study, the stress delivery mechanism of Top-Base Foundation developed in Japan and Floating Top Base developed in Korea is investigated through numerical analysis and laboratory model test. Analyzing the load delivery mechanism of top base, it was found that the division rate of load reduction of top base for overburden load was largest in peripheral skin friction between the top base and the crushed stone. Further, total stress dispersion angle of Top-Base Foundation including internal stress dispersion effect of top base was $41.8^{\circ}$ and total stress dispersion angle of Floating Top Base was $44.5^{\circ}$.

Study on the Measuring Method and Reliability of Top Clearance of Variable Swashplate Type Compressor (가변 사판식 압축기의 탑 클리어런스 측정 방법 및 신뢰성 확보에 관한 연구)

  • Kim, Young-Shin;Na, Seung-Kyu
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.3
    • /
    • pp.89-94
    • /
    • 2016
  • In this experimental study, the effects of top clearance on the performance of automotive a/c compressor were studied. Top clearance measuring device was also developed to ensure the reliability using vacuum conditions to secure constant control of top clearance without external environmental influence. Our results revealed that the improvements in compressor performance according to different top clearance values using the same compressor and same operator were about 4.12% at 800 rpm and about 7.8% at 2,000 rpm in 0.243~0.252 mm of top clearance compared to 0.431~0.456 mm of top clearance. To confirm the consistency in measuring top clearance affecting compressor performance, the top clearance measuring device was developed in this study using a vacuum pump. After performing reliable tests repeatedly, the distribution of measuring values under this device was within 0.99~1.83%, indicating that the constant test data in compressor performance was not affected by any other external environment.

Top Management Commitment in Enterprise Resource Planning Implementation Success : Preliminary Study in Indonesian State-Owned Enterprises

  • Hartijasti, Yanki
    • Journal of Information Technology Applications and Management
    • /
    • v.18 no.3
    • /
    • pp.41-59
    • /
    • 2011
  • This preliminary study held in two Indonesian state-owned enterprises (SOEs) showed empirical evidence that top management commitment was perceived to be the most important critical factor contributing to enterprise resource planning (ERP) implementation success, compared to top management support and top management involvement. Therefore, top management and middle management must continually show commitment during the ERP implementation process. This finding could serve as a reference for further study in a larger number of Indonesian SOEs.

A Study on the Sub-elements of the Top-down Construction Method Selection Model using Weighting Factor in Downtown Area (가중치 분석을 통한 도심지 Top-Down 공사에서의 공법요소 선정 모델 개발에 관한 연구)

  • Park, Chang-Wook;Moon, Seung-Yun;Yun, Seok-Heon
    • Journal of the Korea Institute of Building Construction
    • /
    • v.8 no.4
    • /
    • pp.61-69
    • /
    • 2008
  • The size of the construction projects become huge and complex, and the depth of excavation for the underground structures become deeper. Also the working area is not enough for loading materials and temporary facilities. This is the most case of recent construction projects in downtown area. Top-down is the most useful method for this kind of construction projects. Top-down construction method consists of supporting method, retaining wall type, foundation type and construction direction such as up-down or up-up. construction managers have to select sub-elements for top-down construction method in planning phase. This study is to suggest the sub-elements selection model for the top-down construction method, and the case study is conducted for evaluating this model.

Behavior of Floating Top-Base Foundation on Soft Soils by Laboratory Model Tests (실내모형실험을 통한 연약지반에서 부양형 팽이기초의 거동)

  • Chung, Jin-Hyuck;Chung, Hye-Kwun;Lee, Song
    • Journal of the Korean Geotechnical Society
    • /
    • v.27 no.2
    • /
    • pp.5-15
    • /
    • 2011
  • This research performed the laboratory model tests for Top-Base Foundation developed in Japan and Floating Top-Base Foundation developed in Korea on the typical clayey soft soils, namely, clay, clayey silt and clayey sand. The performances of the two types of top-base foundation were compared with each other and evaluated by measuring load-settlement, heaving of foundation side, ground stress distribution in this model tests. The change of settlement caused by the increase of top base width was also analyzed. As a result of the model tests, Floating Top-Base Foundation showed better performance in bearing capacity improvement, settlement decrease, stress dispersion effect and lateral confinement force. And settlement caused by the increase of top base width converged to a regular value from $5{\times}5$ layout of the width.