• 제목/요약/키워드: TOF

검색결과 1,077건 처리시간 0.029초

A Study on Depth Information Acquisition Improved by Gradual Pixel Bundling Method at TOF Image Sensor

  • Kwon, Soon Chul;Chae, Ho Byung;Lee, Sung Jin;Son, Kwang Chul;Lee, Seung Hyun
    • International Journal of Internet, Broadcasting and Communication
    • /
    • 제7권1호
    • /
    • pp.15-19
    • /
    • 2015
  • The depth information of an image is used in a variety of applications including 2D/3D conversion, multi-view extraction, modeling, depth keying, etc. There are various methods to acquire depth information, such as the method to use a stereo camera, the method to use the depth camera of flight time (TOF) method, the method to use 3D modeling software, the method to use 3D scanner and the method to use a structured light just like Microsoft's Kinect. In particular, the depth camera of TOF method measures the distance using infrared light, whereas TOF sensor depends on the sensitivity of optical light of an image sensor (CCD/CMOS). Thus, it is mandatory for the existing image sensors to get an infrared light image by bundling several pixels; these requirements generate a phenomenon to reduce the resolution of an image. This thesis proposed a measure to acquire a high-resolution image through gradual area movement while acquiring a low-resolution image through pixel bundling method. From this measure, one can obtain an effect of acquiring image information in which illumination intensity (lux) and resolution were improved without increasing the performance of an image sensor since the image resolution is not improved as resolving a low-illumination intensity (lux) in accordance with the gradual pixel bundling algorithm.

Comparative Proteomic Analyses of the Yeast Saccharomyces cerevisiae KNU5377 Strain Against Menadione-Induced Oxidative Stress

  • Kim, Il-Sup;Yun, Hae-Sun;Jin, In-Gnyol
    • Journal of Microbiology and Biotechnology
    • /
    • 제17권2호
    • /
    • pp.207-217
    • /
    • 2007
  • The Saccharomyces0 cerevisiae KNU5377 strain, which was isolated from spoilage in nature, has the ability to convert biomass to alcohol at high temperatures and it can resist against various stresses [18, 19]. In order to understand the defense mechanisms of the KNU5377 strain under menadione (MD) as oxidative stress, we used several techniques for study: peptide mass fingerprinting (PMF) by matrix-assisted laser desorption/ionization-time of flight (MALDI-TOF) mass spectrometry (MS) followed by two-dimensional (2D) gel electrophoresis, liquid chromatography electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS), and surface-enhanced laser desorption ionization-time of flight (SELDI-TOF) technology. Among the 35 proteins identified by MALDI-TOF MS, 19 proteins including Sod1p, Sod2p, Tsa1p, and Ahp1p were induced under stress condition, while 16 proteins were augmented under normal condition. In particular, five proteins, Sod1p, Sod2p, Ahp1p, Rib3p, Yaf9p, and Mnt1p, were induced in only stressed cells. By LC-ESI-MS/MS analysis, 37 proteins were identified in normal cells and 49 proteins were confirmed in the stressed cells. Among the identified proteins, 32 proteins were found in both cells. Five proteins including Yel047cp and Met6p were only upregulated in the normal cells, whereas 17 proteins including Abp1P and Sam1p were elevated in the stressed cells. It was interesting that highly hypothetical proteins such as Ynl281wp, Ygr279cp, Ypl273wp, Ykl133cp, and Ykr074wp were only expressed in the stressed cells. SELDI-TOF analysis using the SAX2 and WCX2 chips showed that highly multiple-specific protein patterns were reproducibly detected in ranges from 2.9 to 27.0 kDa both under normal and stress conditions. Therefore, induction of antioxidant proteins, hypothetical proteins, and low molecular weight proteins were revealed by different proteomic techniques. These results suggest that comparative analyses using proteomics might contribute to elucidate the defense mechanisms of KNU5377 under MD stress.

후집속 방법을 이용한 에어로졸 TOF 질량분석기의 질량분해능 향상 연구 (Study on increasing the mass resolution in aerosol TOF mass spectrometer by using post focusing method)

  • 김덕현;양기호;차형기;김도훈;이상천
    • 분석과학
    • /
    • 제18권6호
    • /
    • pp.483-490
    • /
    • 2005
  • TOF 비행시간을 이용한 에어로졸 질량분석기에서 질량분석기의 분해능은 발생하는 이온의 초기에너지와 이온이 움직이는 진행방향에 따라 달라진다. 고출력 펄스형 레이저에 의하여 에어로졸로부터 용발되어 이온화된 원소들은 다른 속도로 사방으로 퍼져 나가게 되어 분해능 저하를 초래하는데 이를 방지하기 위해서 1차 가속된 이온들을 서로 다른 에너지로 후집속하여 같은 시간에 이온센서에 도달하도록 하는 장치에 대하여 연구를 수행하였다. 후집속 전위를 $90^{\circ}$ 방향으로 진행하는 이온을 중심으로 서로 다른 방향으로 걸어 줌으로써 TOF 영역을 지나 센서로 도입되는 이온의 도착 시간이 크게 개선되었음을 알 수 있었으며, 이를 실증하기 위하여 레이저 유도 이온을 만들고 후집속 장치를 구성하여 최적의 시간지연시간 및 전압 조건을 도출하여 그 성능을 증가시켰다.

Repair of Tetralogy of Fallot in Infancy via the Atrioventricular Approach

  • Bigdelian, Hamid;Sedighi, Mohsen
    • Journal of Chest Surgery
    • /
    • 제49권1호
    • /
    • pp.9-14
    • /
    • 2016
  • Background: Tetralogy of Fallot (TOF) is a well-recognized congenital heart disease. Despite improvements in the outcomes of surgical repair, the optimal timing of surgery and type of surgical management of patients with TOF remains controversial. The purpose of this study was to assess outcomes following the repair of TOF in infants depending on the surgical procedure used. Methods: This study involved the retrospective review of 120 patients who underwent TOF repair between 2010 and 2013. Patients were divided into three groups depending on the surgical procedure that they underwent. Corrective surgery was done via the transventricular approach (n=40), the transatrial approach (n=40), or a combined atrioventricular approach (n=40). Demographic data and the outcomes of the surgical procedures were compared among the groups. Results: In the atrioventricular group, the incidence of the following complications was found to be significantly lower than in the other groups: complete heart block (p=0.034), right ventricular failure (p=0.027) and mediastinal bleeding (p=0.007). Patients in the atrioventricular group had a better postoperative right ventricular ejection fraction (p=0.001). No statistically significant differences were observed among the three surgical groups in the occurrence of tachycardia, renal failure, and tricuspid incompetence. The one-year survival rates in the three groups were 95%, 90%, and 97.5%, respectively (p=0.395). Conclusion: Combined atrioventricular repair of TOF in infancy can be safely performed, with acceptable surgical risk, a low incidence of reoperation, good ventricular function outcomes, and an excellent survival rate.

DMIDR 장치의 재구성 알고리즘 별 성능 평가 (Performance Evaluation of Reconstruction Algorithms for DMIDR)

  • 곽인석;이혁;문승철
    • 핵의학기술
    • /
    • 제23권2호
    • /
    • pp.29-37
    • /
    • 2019
  • DMIDR (General Electric Healthcare, USA)은 GE 사(社)의 최신 장비로써 PSF (Point Spread Function reconstruction), TOF(Time of Flight)와 Q.Clear의 적용이 가능하다. 특히, Q.Clear는 보정 알고리즘으로써 복셀(voxel)단위 신호 잡음 제거로 기존 OSEM (Ordered Subset Expectation Maximization)의 한계를 넘어설 수 있다. 따라서 이러한 재구성 및 보정 알고리즘의 성능 평가를 통해 정확한 SUV를 구현하며, 병변 검출 능력에 도움이 되는 알고리즘의 조합을 확인하고자 하였다. H/B(Hot & Background) Ratio 2:1, 4:1, 8:1의 비율로 NEMA/IEC 2008 PET phantom을 제작하였다. DMIDR의 NEMA test protocol을 이용하여 영상 획득을 하였다. 재구성 조합은 (1) VPFX(VUE point FX(TOF)), (2) VPHD-S(VUE point HD+PSF), (3) VPFX-S(TOF+PSF), (4) QCHD-S-400(VUE point HD+Q.Clear(${\beta}-strength$ 400)+PSF), (5) QCFX-S-400(TOF+Q.Clear(${\beta}-strength$ 400)+PSF), (6) QCHD-S-50(VUE point HD+Q.Clear(${\beta}-strength$ 50)+PSF), (7) QCFX-S-50(TOF+Q.Clear(${\beta}-strength$ 50) + PSF)의 7 가지로 구성하였다. H/B Ratio 및 재구성 알고리즘 별로 측정된 결과를 이용하여 CR (Contrast Recovery)와 BV (Background Variability)을 구하였다. 또한, 각 조합의 count를 측정하여 SNR (Signal to Noise Ratio)과 RC(Recovery Coefficient)를 구하고 SUV (Standardized Uptake Value)를 측정하였다. 구의 크기가 가장 작은 10 mm와 13 mm에서는 VPFX-S, 17 mm 이상에서는 QCFX-S-50에서 가장 높은 CR 결과를 보였다. BV와 SNR의 비교에서는 QCFX-S-400과 QCHD-S-400에서 좋은 값을 보였다. SUV 측정 결과는 H/B ratio와 비례하여 증감하는 양상을 보였다. SUV에 대한 RC의 경우 H/B ratio와 반비례하는 양상을 보였으며, 재구성 알고리즘 중에서는 QCFX-S-50이 가장 높은 값을 보였다. 또한, Q.Clear에 ${\beta}-strength$ 400이 적용된 재구성 알고리즘들이 낮은 값 분포를 보였다. Q.Clear가 적용된 재구성 조합은 ${\beta}-strength$를 높이면 신호잡음이 억제되어 영상 품질면에서 우수한 결과를 보였고 ${\beta}-strength$를 낮추면 선예도가 증가하며, partial volume effect가 감소하여 기존의 재구성 조건에 비하여 높은 RC에 근거한 SUV 측정이 가능하였다. 이러한 진보된 알고리즘의 사용으로 보다 정확한 정량화와 미세병변 검출능력을 향상 시킬 수 있으나 상관 관계를 고려하여 목적에 맞는 최적화 과정이 필요할 것으로 사료된다.

2,6-Disubstituted Pyrylium Fluoroborates 화합물의 합성과 특성 (Synthesis and Characteristics of 2,6-disubstituted Pyrylium Fluoroborates)

  • 조성일
    • 공업화학
    • /
    • 제20권3호
    • /
    • pp.351-353
    • /
    • 2009
  • Pyrylium염 화합물은 양전하를 띄고 있어 유용한 합성반응에 널리 이용되고 있다. 또한 전자를 받아들이는 특성을 갖고 있어 광유도전자전이(PET) 반응의 감광제 등에 응용되고 있다. 우리는 본 연구에서 몇몇 2,6-disubstituted pyrylium fluoroborate 염 화합물을 산성 매체(acetic anhydride/acid) 하에서 합성하였다. 합성한 화합물을 $^{1}H-NMR$, FT-IR과 TOF Mass로 그 구조를 확인하였다. 또한, 그 광특성을 UV-Vis를 통해 분석하였다.

화학적 성분 분석능력을 가진 원자 현미경의 제작 (A micromachined cantilever for chemically sensitive scanning force microscope applications)

  • 이동원
    • 센서학회지
    • /
    • 제14권1호
    • /
    • pp.1-6
    • /
    • 2005
  • This paper describes a novel concept of a chemically sensitive scanning force microscope (CS-SFM). It consists of the conventional SFM and the time-of-flight mass spectrometer (TOF-MS). A switchable cantilever (SC) fabricated by the micromachining technology combines each advantage of two completely different systems, SFM and TOF-MS. The CS-SFM offers to produce both images of topography and chemical information simultaneously. First we employed a rotatable tip holder based on 4 piezotube actuators for demonstration of the possibility of the CS-SFM concept. Second the CS-SFM concept is optimized with the micromachining technology. The micromachined SC with an integrated bimorph actuator and a piezoresistive strain sensor provides a reasonable switching speed of ${\sim}10$ ms which is very attractive for the CS-SFM application. The SC is currently being integrated in an ultra-high-vacuum system to perform various experiments.

홍합 [Mytilus coruscus]으로부터 항균활성 펩타이드의 정제 (Purification of a Antimicrobial Peptide from the Marine Mussel, Mytilus coruscus)

  • 김인혜;김진욱;이재화
    • 한국환경성돌연변이발암원학회지
    • /
    • 제26권1호
    • /
    • pp.25-29
    • /
    • 2006
  • 흥합 (Mytilus coruscus) 추출물 RM 60을 사용하여 E. coli D31을 대상으로 항균활성 펩타이드를 분리 정제하였다. 정제한 펩타이드는 MALDI-TOF Mass spectrometry를 사용하여 분자량을 측정한 결과, 1464.92 Da로 나타났으며 Edman 분해법을 이용한 peptide sequencer를 사용하여 일차구조를 분석 중에 있다.

  • PDF

Agrobacterium sp. ATCC31750에 대한 beta-l,3-glucan 합성 대사경로의 주요 단백질 검출 (Identification of Key beta-1,3-glucan Synthesis Enzymes in Agrobacterium sp. ATCC31750)

  • 김려화;이중헌
    • KSBB Journal
    • /
    • 제19권5호
    • /
    • pp.406-409
    • /
    • 2004
  • Matrix Assisted Laser Desorption ionization Time of Flight (MALDI-TOF) was used for enzymes identification related to B -1,3-glucan synthesis. Agrobacterium sp. ATCC31750 was cultivated with two stage Continuous Stirrer Tank Reactor (CSTR) and the cells were harvested and their protein profiles were analysed by two dimensional electrophoresis. The specific enzyme spot was treated with trypsin and ana lysed by MALDI-TOF to get peptide molecular weight. The peptide molecular weights were matched with Agrobacterium tumefacience's Data Base from the matrix science site, then could identify the avaliable key enzymes. In this study, we identified key metabolite of synthesis of beta-1,3-glucan, such as glucose-6-phosphate isomerase, phosphoglucomutase, B-1,3-glucan synthase and glucokinase, and we also identified uracil phosphoribocyl transferase and Ribosome recycling factor also.

Peptide C-terminal Sequence Analysis by MALDI-TOF MS Utilizing EDC Coupling with Br Signature

  • Shin, Man-Sup;Kim, Hie-Joon
    • Bulletin of the Korean Chemical Society
    • /
    • 제32권4호
    • /
    • pp.1183-1186
    • /
    • 2011
  • The unique Br signature was utilized for C-terminal amino acid sequencing of model peptides. C-terminal carboxyl group was selectively derivatized in peptides, containing side chain carboxyl group, using 1-ethyl-3-[3-dimethylaminopropyl]carbodiimide hydrochloride (EDC) and Br was introduced using 4-bromophenylhydrazine hydrochloride (BPH) in a one pot reaction. Matrix-assisted laser desorption/ionization (MALDI) time-of-flight (TOF) tandem mass spectra were obtained carrying the Br signature in the y-series ions. The Br signature facilitated C-terminal sequencing and discrimination of C-terminal carboxyl groups in the free acid and amide forms.