• 제목/요약/키워드: TLP system

검색결과 45건 처리시간 0.017초

Cathode Side Engineering to Raise Holding Voltage of SCR in a 0.5-㎛ 24 V CDMOS Process

  • Wang, Yang;Jin, Xiangliang;Zhou, Acheng;Yang, Liu
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제15권6호
    • /
    • pp.601-607
    • /
    • 2015
  • A set of novel silicon controlled rectifier (SCR) devices' characteristics have been analyzed and verified under the electrostatic discharge (ESD) stress. A ring-shaped diffusion was added to their anode or cathode in order to improve the holding voltage (Vh) of SCR structure by creating new current discharging path and decreasing the emitter injection efficiency (${\gamma}$) of parasitic Bipolar Junction Transistor (BJT). ESD current density distribution imitated by 2-dimensional (2D) TCAD simulation demonstrated that an additional current path exists in the proposed SCR. All the related devices were investigated and characterized based on transmission line pulse (TLP) test system in a standard $0.5-{\mu}m$ 24 V CDMOS process. The proposed SCR devices with ring-shaped anode (RASCR) and ring-shaped cathode (RCSCR) own higher Vh than that of Simple SCR (S_SCR). Especially, the Vh of RCSCR has been raised above 33 V. What's more, their holding current is kept over 800 mA, which makes it possible to design power clamp with SCR structure for on chip ESD protection and keep the protected chip away from latch-up risk.

복합 원형 실린더군의 저진폭 동위상 진동에 의한 점성유동 및 동유체력에 관한 연구 (A Research on the viscous flow and the hydrodynamic force due to the small-amplitude in-phase oscillation of multi-cylinders)

  • 김성균
    • 대한조선학회논문집
    • /
    • 제36권2호
    • /
    • pp.22-28
    • /
    • 1999
  • 복합원형 실린더군의 미소진폭 동위상 진동유동에 대해 수치해석적 및 실험적으로 연구하였다. 유동장은 내부와 외부로 분리하여 해석되어진다. 1차 비선형해는 스톡스 진동해로서 해석적으로 구해지며, 경계층 외부의 2차 정상유동은 경계적분법(Panel Method)와 유한체적법(Finite Volume Code)에 의해 구하였다. 수치해석해와 정성적 정량적으로 비교하기 위하여, 전유동장 측정기법의 하나인 입자영상유속계(PIV)기법을 사용하였으며, 계산시간 단축을 위해 영상압축 및 코드화기법에서 개발된 삼단계추적 알고리즘을 도입하였다. TLP등 저 댐핑 시스템에 있어서 작지만 0 아닌 항력계수의 정확한 시스템 거동 및 공진에 의한 파괴문제에 있어서 중요한 과제이다. 본 논문에서는 실린더의 갯수와 배열, 간격의 변화에 따른 항력계수 값들을 계산하여 도표화하였다.

  • PDF

신재생에너지용 연계형 인버터의 고효율 승압에 관한 연구 (Study on High Efficiency Boosting-up Circuit for Renewable Energy Application)

  • 정태욱;김주용;최세권;조준석;고희석
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2009년도 춘계학술대회 논문집
    • /
    • pp.336-339
    • /
    • 2009
  • In this paper, such as battery power or solar energy and fuel cells generated from Renewable energy sources, high voltage to low voltage DC-DC Converter for converting the design of the study. System consists of low voltage ($24{\sim}28$ [VDC]) and Boosts the voltage (270 [VDC]) for a 3 [kW] DC-DC converter and control circuit is configured as, Power switch the ST Tomson's Automotive low voltage high current MOSFET switches STE250NS10S (temperature 250A) was applied to the two parallel. Also, Controller's processor used ATMEGA128, and Gate Drive applies and composed Photo Coupler TLP250. development. Input voltage (24V) and output voltage (270V) for Conversion in the H-bridge converter topology of the circuit output side power and voltage to control the implementation of the Phase shift angle control applied. And, 3kW of power to pass appropriate specification of the secondary side as interpreted by the high frequency transformer, and the experimental production and analysis of the experiment

  • PDF

고전압 집적회로를 위한 래치업-프리 구조의 HBM 12kV ESD 보호회로 (A 12-kV HBM ESD Power Clamp Circuit with Latchup-Free Design for High-Voltage Integrated Circuits)

  • 박재영;송종규;장창수;김산홍;정원영;김택수
    • 대한전자공학회논문지SD
    • /
    • 제46권1호
    • /
    • pp.1-6
    • /
    • 2009
  • 고전압 소자에서 스냅백 이후의 유지 전압은 구동전압에 비해 매우 작아서 고전압 MOSFET이 ESD(ElecroStatic Discharge) 파워클램프로 바로 사용될 경우 래치업 문제를 일으킬 수 있다. 본 연구에서는 스택 바이폴라 소자를 이용하여 래치업 문제가 일어나지 않는 구조를 제안하였다. 제안된 구조에서는 유지 전압이 구동전압 보다 높으므로 래치업 문제가 발생하지 않으면서, 기존의 다이오드를 사용한 고전압 파워클램프에 비해 면적이 작으며, 내구성 측면에서 800% 성능향상이 있게 되었다. 제안된 구조는 $0.35{\mu}m$ 60V BCD(Bipolar-CMOS-DMOS) 공정을 사용하여 제작되었으며, TLP(Transmission Line Pulse) 장비로 웨이퍼-레벨 측정을 하였다.

불규칙 파랑 중 해중 터널 계류선의 단기 피로 손상 분석 (Investigation of Fatigue Damage of the Mooring Lines for Submerged Floating Tunnels Under Irregular Waves)

  • 김승준;원덕희
    • 한국강구조학회 논문집
    • /
    • 제29권1호
    • /
    • pp.49-60
    • /
    • 2017
  • 부유식 구조물의 계류선의 설계는 강도뿐만 아니라 피로수명 측면에서도 검토가 반드시 요구된다. 일반적으로 계류선의 피로 설계에는 동적 응력을 야기하는 하중이 지배적인 영향을 미치게 된다. 즉, 파랑이 주요 설계 하중으로 고려가 된다. 본 연구에서는 불규칙 파랑에 대한 해중 터널 계류선의 피로 손상 특성에 대해 분석한다. 시간 이력 유체-구조 동역학 해석을 통해 특정 환경 하중에 대한 해중터널의 동적 운동 및 계류선에 발생하는 장력과 응력을 계산하고, Rainflow 집계법 및 Palmgren-Miner의 법칙 그리고 DNV 기준에서 제시하는 해양구조물 설계를 위한 S-N 곡선을 고려하여 단기 피로 손상을 추정한다. 해중 터널의 계류 형식과 유사한 계류 형식을 갖는 인장각 플랫폼의 텐던 설계를 참고하여 100년 재현 주기 파랑이 48시간 지속되는 조건을 가정하여 이 환경 하중에 의한 피로 손상도를 추정한다. 본 해석 절차를 따르며, 함체의 흘수와 계류선의 간격 및 초기 기울임 각도가 피로 손상도에 미치는 영향을 분석한다.