• Title/Summary/Keyword: THRESHOLD

Search Result 8,523, Processing Time 0.034 seconds

A Comparsion study of Phonation Threshold Pressure and Nasalance according to vowels (모음에 따른 발성역치압력과 비성도 특성 비교 연구)

  • Lee, Inae;Hwang, Young-Jin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.2
    • /
    • pp.721-727
    • /
    • 2013
  • This study sought to compare the difference of Phonation Threshold Pressure and Nasalance according to vowels. We tested 28 normal females(20~30age) who be in attendance at a school from May to August 2012. We measured Phonation Threshold Pressure through PAS(Phonatory aerodynamic system, model 6600, KAY electronics, Inc) that aero-mechanical instrument called. Phonation Threshold Pressure was measured by using the consonant /p/ and the three vowels /a, i, u/ and was analyzed the three times of Phonation the five times. Also We measured Nasalance through the Nasometer${\Pi}$(model 6450, KAY electronics, Inc). The vowel's phonation was recored by using the three vowels /a, i, u/. the nasalance score was measured via Nasometer. As a Result, Phonation Threshold Pressure according to three vowels show significantly difference. Also, Nasalance according to three vowels show significantly difference. Finally, Correlation coefficient of Phonation Threshold Pressure and Nasalance according to three vowels show positive relation ship. Therefore Phonation Threshold Pressure and Nasalance according to three vowels have closely relationship.

Threshold Voltage Shift for Doping Profile of Asymmetric Double Gate MOSFET (도핑분포함수에 따른 비대칭 이중게이트 MOSFET의 문턱전압이동현상)

  • Jung, Hakkee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.4
    • /
    • pp.903-908
    • /
    • 2015
  • This paper has analyzed threshold voltage shift for doping profile of asymmetric double gate(DG) MOSFET. Ion implantation is usually used in process of doping for semiconductor device and doping profile becomes Gaussian distribution. Gaussian distribution function is changed for projected range and standard projected deviation, and influenced on transport characteristics. Therefore, doping profile in channel of asymmetric DGMOSFET is affected in threshold voltage. Threshold voltage is minimum gate voltage to operate transistor, and defined as top gate voltage when drain current is $0.1{\mu}A$ per unit width. The analytical potential distribution of series form is derived from Poisson's equation to obtain threshold voltage. As a result, threshold voltage is greatly changed by doping profile in high doping range, and the shift of threshold voltage due to projected range and standard projected deviation significantly appears for bottom gate voltage in the region of high doping concentration.

Analysis of Channel Doping Profile Dependent Threshold Voltage Characteristics for Double Gate MOSFET (이중게이트 MOSFET에서 채널도핑분포의 형태에 따른 문턱전압특성분석)

  • Jung, Hak-Kee;Han, Ji-Hyung;Lee, Jae-Hyung;Jeong, Dong-Soo;Lee, Jong-In;Kwon, Oh-Shin
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.15 no.6
    • /
    • pp.1338-1342
    • /
    • 2011
  • In this paper, threshold voltage characteristics have been analyzed as one of short channel effects occurred in double gate(DG)MOSFET to be next-generation devices. The Gaussian function to be nearly experimental distribution has been used as carrier distribution to solve Poisson's equation, and threshold voltage has been investigated according to projected range and standard projected deviation, variables of Gaussian function. The analytical potential distribution model has been derived from Poisson's equation, and threshold voltage has been obtained from this model. Since threshold voltage has been defined as gate voltage when surface potential is twice of Fermi potential, threshold voltage has been derived from analytical model of surface potential. Those results of this potential model are compared with those of numerical simulation to verify this model. As a result, since potential model presented in this paper is good agreement with numerical model, the threshold voltage characteristics have been considered according to the doping profile of DGMOSFET.

Accuracy Improvement Methode of Step Count Detection Using Variable Amplitude Threshold (가변 진폭 임계값을 이용한 걸음수 검출 정확도 향상 기법)

  • Ryu, Uk Jae;Kim, En Tae;An, Kyung Ho;Chang, Yun Seok
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.2 no.6
    • /
    • pp.257-264
    • /
    • 2013
  • In this study, we have designed the variable amplitude threshold algorithm that can enhance the accuracy of step count using variable amplitude. This algorithm converts the x, y, z sensor values into a single energy value($E_t$) by using SVM(Signal Vector Magnitude) algorithm and can pick step count out over 99% of accuracy through the peak data detection algorithm and fixed peak threshold. To prove the results, We made the noise filtering with the fixed amplitude threshold from the amplitude of energy value that found out the detection error was increasing, and it's the key idea of the variable amplitude threshold that can be adapted on the continuous data evaluation. The experiment results shows that the variable amplitude threshold algorithm can improve the average step count accuracy up to 98.9% at 10 Hz sampling rate and 99.6% at 20Hz sampling rate.

Comparison of Cleansing Regimes for Efficacy and Comfort of Iontophoretic Transdermal Lidocaine Delivery (세정방법에 따른 국소마취제 이온도입의 효율과 편안감 비교)

  • Jeong, Myung-A;Song, In-Yong;Lee, Jae-Hyoung
    • The Journal of Korean Physical Therapy
    • /
    • v.18 no.4
    • /
    • pp.41-50
    • /
    • 2006
  • Purpose: The purpose of this study was to determined that the efficacy and comfort of iontophoretic transdermal delivery of lidocaine by comparison of local anesthetic duration, sensory threshold, pain threshold and pain tolerance levels according to four different cleansing regimes. Methods: Forty healthy volunteers were randomly assigned to four groups; oil cleansing group, lotion cleansing group, solution cleansing group and alcohol cleansing group. All subjects were received lidocaine iontophoresis on the forearm using direct current with 4 mA for 10 minutes. All subjects were measured the duration of local anesthesia after lidocaine iontophoresis, also evaluated the sensory threshold, pain threshold and pain tolerance level during iontophoresis. For comparisons of the efficacy and the sensory characteristics of iontophoresis within the groups, an one-way ANOVA was used. Results: The duration of local anesthesia were found significant difference between groups (p<0.001). The anesthetic duration in solution and alcohol cleansing groups were significantly longer than oil and lotion cleansing group by post hoc (p<0.05). Statistically significant difference were noted in respect to all sensory characteristics such as sensory threshold, pain threshold and pain tolerance between groups (p<0.001). The sensory threshold in solution and alcohol cleansing group were significantly lower than oil and lotion cleansing group by post hoc using Duncan multiple range test (p<0.05). The pain threshold and pain tolerance in solution and alcohol cleansing group were significantly higher than oil and lotion cleansing group by post hoc (p<0.05). Conclusion: These results demonstrated that cleansing regimes have affected the efficacy and discomfort of iontophoretic transdermal delivery of lidocaine. These findings indicate that cleansing agents without oil ingredient contributed to more comfort, and more successful achievement of the iontophoretic transdermal delivery.

  • PDF

Analysis of the Change of the Neck Pressure Pain Threshold in Long Term Computer Users (장시간 컴퓨터 사용자의 경부압력통증역치 변화 분석)

  • HwangBo, Gak
    • The Journal of the Korea Contents Association
    • /
    • v.8 no.6
    • /
    • pp.151-158
    • /
    • 2008
  • Poor posture of the neck and head has long been recognized as a factor contributing to the onset and perpetuation of pain in the head and neck region. This study were to evaluate the change of the neck pressure pain threshold in long term computer users. To elucidate change of the neck pressure pain threshold in long term computer users, the effect of computer using time(3, 6, 9, 12 and 15 hours) on neck pressure pain threshold were studied in 20 subjects. Neck pressure pain threshold were recorded 3, 6, 9, 12 and 15 hours group, and evaluated by pressure algometry to Trapezius muscle, Sternocleidomastoidius muscle, Suboccipitalis muscle and Temporalis muscle. Neck pressure pain threshold was significantly larger in 15 hours group(p<.05). But relation between neck pressure pain threshold in male group and female group were not significant differences(p>.05).

A Study Comparing the Effects of Burst Mode and High Rate Mode Transcutaneous Electrical Nerve Stimulation on Experimental Pain Threshold and Skin Temperature (Burst형과 고빈도형 경피신경전기자극치료가 실험적 동통역치와 체온에 미치는 영향 비교)

  • Kim, Suhn-Yeop;Choi, Houng-Sik;Kwon, Oh-Yun
    • Journal of Korean Physical Therapy Science
    • /
    • v.2 no.2
    • /
    • pp.465-479
    • /
    • 1995
  • We randomly assigned 61 healthy subjects(male 14, female 47) to compare the experimental pain threshold and skin temperature between high mode TENS and burst mode TENS. In this study, 61 subjects were divided into three groups ; high mode TENS(n=20), burst mode TENS (n=20), and control group(n=21). Experimental pain thresholds and skin temperatures were measured before, immediately after cessation of stimulation, and at 30 minutes post stimulation. Stimulation was applied to the dorsal surface of the forearm(L14, LI10). Pain thresholds were measured by chronaxie meter. Skin temperature were measured by electrical digital thermometer. The results are as follows ; 1. There were no statistical difference in the pain threshold and skin temperature at before TENS stimulation among the three groups(p>0.05). 2. The pain threshold and skin temperature in burst mode TENS group was significantly higher and longer effect than that in high mode TENS group and control group(p<0.01). 3. The pain threshold in burst mode TENS group decreased to prestimulation levels by 30 minutes poststimulation. 4. The skin temperature in burst mode TENS group decreased to prestimulation levels by 20 minutes poststimulation. 5. The skin temperature was significantly difference among three group at immediately after, and at 30 minutes poststimulation and the skin temperature in burst mode TENS group was significantely higher than that in two groups(p<0.001). 6. The increasing rate of pain threshold in high mode TENS group after immediately cassation of stimulation was 24.3%(p<0.001). 7. The increasing rate of pain threshold in burst mode TENS group after immediately cessation of stimulation was 93.5% (p<0.001).

  • PDF

Analysis on Optimal Threshold Value for Infrared Video Flame Detection (적외선 영상의 화염 검출을 위한 최적 문턱치 분석)

  • Jeong, Soo-Young;Kim, Won-Ho
    • Journal of Satellite, Information and Communications
    • /
    • v.8 no.4
    • /
    • pp.100-104
    • /
    • 2013
  • In this paper, we present an optimal threshold setting method for flame detection of infrared thermal image. Conventional infrared flame detection methods used fixed intensity threshold to segment candidate flame regions and further processing is performed to decide correct flame detection. So flame region segmentation step using the threshold is important processing for fire detection algorithm. The threshold should be change in input image depends on camera types and operation conditions. We have analyzed the conventional thresholds composed of fixed-intensity, average, standard deviation, maximum value. Finally, we extracted that the optimal threshold value is more than summation of average and standard deviation, and less than maximum value. it will be enhance flame detection rate than conventional fixed-threshold method.

An Adaptive Pruning Threshold Algorithm for the Korean Address Speech Recognition (한국어 주소 음성인식의 고속화를 위한 적응 프루닝 문턱치 알고리즘)

  • 황철준;오세진;김범국;정호열;정현열
    • The Journal of the Acoustical Society of Korea
    • /
    • v.20 no.7
    • /
    • pp.55-62
    • /
    • 2001
  • In this paper, we propose a new adaptative pruning algorithm which effectively reduces the search space during the recognition process. As maximum probabilities between neighbor frames are highly interrelated, an efficient pruning threshold value can be obtained from the maximum probabilities of previous frames. The main idea is to update threshold at the present frame by a combination of previous maximum probability and hypotheses probabilities. As present threshold is obtained in on-going recognition process, the algorithm does not need any pre-experiments to find threshold values even when recognition tasks are changed. In addition, the adaptively selected threshold allows an improvement of recognition speed under different environments. The proposed algorithm has been applied to a Korean Address recognition system. Experimental results show that the proposed algorithm reduces the search space of average 14.4% and 9.14% respectively while preserving the recognition accuracy, compared to the previous method of using fixed pruning threshold values and variable pruning threshold values.

  • PDF

Sex Differences in Pain Threshold and Pain Tolerance and the Effects of Experimenter Gender on Pain Report (남녀별 및 실험자의 성별에 따른 동통역치와 동통내성의 차이)

  • Yun-Kyung Hur;Jae-Kap Choi
    • Journal of Oral Medicine and Pain
    • /
    • v.20 no.1
    • /
    • pp.97-103
    • /
    • 1995
  • The purpose of this study was to evaluate the effect of experimenter gender on pain report as well as the sex differences in pain threshold and pain tolerance. Cold pressor test and pressure pain threshold (PPT) test were performed on forty dental students by both of a male and a female experimenter separately with 1 day interval. The obtained results were as follows : There were no differences in pain threshold and pain tolerance between males and females when they were examined by the same gender experimenter in the cold pressor test, but when they were examined by the opposite gender experimenter the pain threshold of males was significantly higher than females. When the pain threshold was measured by the same gender experimenter, using a algometer, there was no differences in PPT between males and females. However, when the same measurements were done by the opposite gender experimenter, the PPT of males was significantly higher than females at anterior temporalis and inferior masseter. For cold pressor test, females tended to report lower levels of pain threshold and pain tolerance to a male experimenter than a female, but the differences were not significant. Although both pain threshold and pain tolerance were increased when males were examined by a female experimenter in the cold pressor test, the statistical significance was found only in pain tolerance. When subjects were examined by the opposite gender experimenter in the PPT text, females reported significantly higher levels of pain at inferior masseter and males reported significantly lower levels of pain at anterior temporalis and inferior masseter.

  • PDF