• Title/Summary/Keyword: TEST-1

Search Result 59,887, Processing Time 0.075 seconds

Design of Bayesian Zero-Failure Reliability Demonstration Test and Its Application (베이지안 신뢰성입증시험 설계와 활용)

  • Kwon, Young Il
    • Journal of Applied Reliability
    • /
    • v.13 no.1
    • /
    • pp.1-10
    • /
    • 2013
  • A Bayesian zero-failure reliability demonstration test method for products with exponential lifetime distribution is presented. Beta prior distribution for reliability of a product is used to design the Bayesian test plan and selecting a prior distribution using a prior test information is discussed. A test procedure with zero-failure acceptance criterion is developed that guarantees specified reliability of a product with given confidence level. An example is provided to illustrate the use of the developed Bayesian reliability demonstration test method.

Development of Accelerated Life Tests for Solid Aluminum Electrolyte Capacitor Made by Domestic Manufacturing Company and Comparison of Characteristics between Domestic Products and Foreign Advanced Products (국산 고체 알루미늄 전해 커패시터의 가속수명시험 개발 및 국외 선진업체 제품과의 특성 비교)

  • 박정원;이중휘
    • Journal of Applied Reliability
    • /
    • v.2 no.1
    • /
    • pp.1-14
    • /
    • 2002
  • High temperature operating test, temperature humidity test and temperature cycling were performed at various test levels for solid aluminum electrolyte capacitors made by domestic manufacturing company and foreign advanced manufacturing company. It was found that main failure mode of solid aluminum electrolyte capacitors was the decrease of their capacitances. The decrease of their capacitances has the same pattern in these tests. Test result for comparison of characteristics between domestic products and foreign advanced products shows that domestic products have the shorter lifetime and their capacitances decrease more rapidly in high temperature operating test and temperature humidity test. Also in these tests, accelerated tests for high temperature operating test and temperature humidity test were developed.

  • PDF

Development of Combustion Test Facility for Liquid Rocket Engine (액체로켓엔진 성능 및 냉각특성 연구를 위한 연소시험장치 개발)

  • Kim, Dong-Hwan;Lee, Seong-Ung;Yu, Byeong-Il
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.34 no.2
    • /
    • pp.106-111
    • /
    • 2006
  • Combustion test facility for liquid rocket engine using kerosene and liquid oxygen has been developed for the purpose of cooling and performance study. Test engine of thrust under 1.0 KN can be evaluated, and the real combustion test ensures a good operation of the combustion test facility. Combustion test facility will be modified to supply natural gas and liquefied natural gas as fuel and to give a regenerative cooling test.

Two tests using more assumptions but lower power

  • Sang Kyu Lee;Hyoung-Moon Kim
    • Communications for Statistical Applications and Methods
    • /
    • v.30 no.1
    • /
    • pp.109-117
    • /
    • 2023
  • Intuitively, a test with more assumptions has greater power than a test with fewer assumptions. This kind of examples are abundant in the nonparametric tests vs corresponding parametric ones. In general, the nonparametric tests are less efficient in terms of asymptotic relative efficiency (ARE) compared to corresponding parametric tests (Daniel, 1990). However, this is not always true. To test equal means under independent normal samples, the usual test involves using the t-distribution with the pooled estimator of the common variance. Adding the assumption of equal sample size, we may derive another test. In this case, two tests using more assumptions were performed for univariate (multivariate) cases. For these examples, it was found that the power function of a test with more assumptions is less than or equal to that of a test with fewer assumptions. This finding can be used as an expository example in master's mathematical statistics courses.

Study on the Direct Tensile Test for Cemented Soils Using a Built-In Cylinder (내장형 실린더를 이용한 시멘트 고결토의 인장시험 방법에 관한 연구)

  • Park, Sung-Sik;Lee, Jun-Woo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.34 no.5
    • /
    • pp.1505-1516
    • /
    • 2014
  • In this study, a cylinder embedded within cemented soils was used to cause directly tensile failure of cemented soils. An existing dumbbell type direct tensile test and a split tensile test that is most general indirect tensile test were also carried out to verify the developed built-in cylinder tensile test. Testing specimens with two different sand/cement ratios (1:1 and 3:1) and two curing periods (7 and 28 days) were prepared and tested. Total 10 specimens were prepared for each case and their average value was evaluated. Unconfined compression tests were also carried out and the ratio of compressive strength and tensile strength was evaluated. The tensile strength determined by built-in cylinder tensile test was slightly higher than that by dumbbell type direct tensile test. The dumbbell type test has often failed in joint part of specimen and showed some difficulty to prepare a specimen. Among three tensile testing methods, the standard deviation of tensile strength by split tensile test was highest. It was shown that the split tensile test is applicable to concrete or rock with elastic failure but not for cemented soils having lower strength.

Pulp Vitality Evaluation and Comparison with Old Methods Using Pulse Oximetry (맥박산소측정기(pulse oximetry)를 이용한 치수 생활력 측정과 기존 방법과의 비교)

  • Kwon, Ik-Jae;Seo, Kwang-Suk;Kim, Jung-Wook;Chang, Ju-Hea;Kong, Hyoun-Joong
    • Journal of The Korean Dental Society of Anesthesiology
    • /
    • v.12 no.1
    • /
    • pp.17-23
    • /
    • 2012
  • Background: This study evaluated pulp vitality of anterior permanent teeth using pulse oximetry (PO), which is already used for monitoring of patient's $SpO_2$ and pulse rates (PR). Also we compared with ice tests and electric pulp test (EPT). Methods: 9 teeth, endodontic treated, were selected as non-vital teeth group. 17 vital teeth were selected as control group. Our aim is to compare sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of ice test, electric pulp test and pulse oximetry, respectively. Pulse oximetry has two test results, $SpO_2$ and pulse rates. Also we calculated correlation and statistical significances by Pearson's test between EPT and pulse oximetry. Results: Sensitivity, specificity, PPV, NPV were calculated on each tests. Ice test has results of 1.00, 0.89, 0.94 and 1.00, respectively. EPT has results of 0.94, 0.78, 0.89 and 0.88 respectively. $SpO_2$ has results of 0.94, 1.00, 1.00 and 0.90, respectively. PR has results of all 1.00. Conclusions: PO showed relatively accurate, stable and objective results on both $SpO_2$ and PR. Percentage of ability of accurate diagnosis for vital teeth is 94% for ice test, 89% for EPT, 100% for $SpO_2$ and PR. Percentage of ability of accurate diagnosis for non-vital teeth is 100% for ice test, 88% for EPT, 90% for $SpO_2$ and 100% for PR. In additions, PR could be more accurate and significant tests than $SpO_2$.

An Assessment on effect of Bioabsorbable membrane, allogenic bone and Platelet Rich Plasma in Class II furcation involvement by digital subtraction radiography (2급 치근이개부 치료 시 흡수성 차폐막, 동종골 이식 및 혈소판 농축 혈장의 골 재생 효과에 대한 디지털 공제술의 정량적 분석)

  • Kim, Sang-Hoon;Lim, Sung-Bin;Chung, Chin-Hyung
    • Journal of Periodontal and Implant Science
    • /
    • v.32 no.1
    • /
    • pp.173-186
    • /
    • 2002
  • The purpose of this study was to evaluate effect of platelet rich plasma on the treatment of Grade II furcation involvement, with Demineralized Freeze-Dried Bone(Dembone(R)) and bioabsorable membrane(BioMesh(R)) in humans by digital subtraction radiography. 12 teeth(control group) were treated with Demineralized Freeze-Dried Bone(Dembone(R)) and bioabsorable membrane(BioMesh(R)), and 12 teeth(test group) were treated with Demineralized Freeze-Dried Bone(Dembone(R)), bioabsorable membrane(BioMesh(R)) and Platelet Rich Plasma. The change of bone density was assessed by digital subtraction radiography in this study. The change of mineral content by as much as 5%(vol) could be perceived in the subtracted images. The change of mineral content was assessed in the method that two radiographs are put into computer program to be overlapped and the previous image is subtracted by the later one. Both groups were statistically analyzed by Wilcoxon signed Ranks Test and Mann-whitney Test using SPSS program (5% significance level). The results were as follows: 1. In test group, the radiopacity in 3 months after surgery were significantly increased than 1 month after surgery(p<0.05). However. there were no significant difference between 1 month after surgery and 3 months after surgery in control group(p>0.05). 2. In test and control group, the radiopacity in 6 months after surgery were significantly increased than 1 month after surgery(p<0.05) 3. In test and control group, the radiopacity in 6 months after surgery were significantly increased than 3 months after surgery(p<0.05). 4. There were no significant difference between test group and control group at 1 month, 3 months after surgery, but radiopacity in test group were significantly increased than control group at 6 months after surgery(p<0.05). In conclusion, Platelet Rich Plasma can enhance bone density.

Vibration Test Result and Consideration for AUTS(Advanced Urban Transit System (차세대전동차 진동시험 결과 및 고찰)

  • Hong, Jai-Sung;Kim, Gil-Dong;Lee, Chang-Mu;Won, Jong-Un;Lee, An-Ho;Sung, Chang-Won
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.2276-2279
    • /
    • 2011
  • The AUTS(Advanced Urban Transit System) are developed by government R&D business. This units are under main line performance test in Daebul test line. Both AC and DC could apply to the AUTS for pantagraph voltage. So main transformer and some high voltage filters are added to the under-frame. As a result the total weight of each car(Mc1-Tp1-M-T-Tp2-Mc2) is different. And axle load is different each other. The main characteristics of AUTS(Advanced Urban Transit System) are as follows. One inverter control one motor, DDM(Dircet Drive Motor), no driving gear, plug no end door, self-steering bogie etc. These matters could be appeared to strange vibration. So vibration test is important. The vibration test performed to Mc1 and Tp1. The results were checked to the up-down direction and left-right direction for acceleration.

  • PDF

Mutagenicity of 2-[(4- Cyanophenyl)amino] -3-chloro-1, 4- naphthalenedione (NQ-Y15) (2-[(4- Cyanophenyl)amino] -3-chloro-1, 4- naphthalenedione (NQ-Y15)의 돌연 변이원성)

  • 김봉희;정기화;유충규;창동신;이기선;전선덕;소동수;채상호;문창규
    • Environmental Analysis Health and Toxicology
    • /
    • v.15 no.4
    • /
    • pp.157-163
    • /
    • 2000
  • 2- [(4- Cyanophenyl)amino] -3-chloro-1, 4- naphthalenedione (NQ-Y15) was asssayed for its genotoxic potential by using Salmonella typhimurium reversion assay and in vitro chromosome aberration test on Chinese hamster lung cells. In the Ames test, NQ-Y15 induced his + revertants of Salmonella typhimurium TA 98 and TA1537, reaching levels twice the negative control values. But, NQ-Y15 induced only his+ revertants of Salmonella typhimurium TA1537 more than twice the control values under the condition with metabolic activation system. In the cytogenetic test on chinese hamster lung cells. NQ -Y15 showed significant chromosomal aberrations, but the incidence was significantly reduced in the presence of metabolic activation.

  • PDF

Thermo-Mechanical Fatigue Analysis of Ribbon Wire/Ag Electrode Interfaces for PV Module

  • Park, No-Chang;Hong, Won-Sik;Han, Chang-Un;Kim, Dong-Hwan
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2011.05a
    • /
    • pp.48.1-48.1
    • /
    • 2011
  • In this presentation, We monitored weather data, such as global irradiance, ambient temperature, temperature of PV module, relative humidity and windspeed for 2 years, for determining accelerated test condition. then, we determined the temperature limit of accelerated test through weather data and FEM analysis. Detailed procedures will be summarized in this work. After analysing outdoor stress such as thermal stress, we decided main failure modes and mechanisms of PV module, especially solder joint of ribbon wire. we carried out the measurement of material properties such as thermal expansion coefficient for planning of accelerated test. we designed accelerated test based on FEM analysis results. we carried out thermal cycling test with 1 cell mini module for 3 months. We monitored the change of electrical performance every 1 week such as Voc, Isc, Pmax, etc. and then, we analized the ribbon wire/electrode intefaces. Detailed results will be summarized in this work.

  • PDF