A New Test Algorithm for High-Density Memories (고집적 메모리를 위한 새로운 테스트 알고리즘)

  • Kang, Dong-Chual;Cho, Sang-Bock
    • Proceedings of the IEEK Conference
    • /
    • 2000.11b
    • /
    • pp.59-62
    • /
    • 2000
  • As the density of memories increases, unwanted interference between cells and coupling noise between bit-lines are increased and testing high density memories for a high degree of fault coverage can require either a relatively large number of test vectors or a significant amount of additional test circuitry. From now on, conventional test algorithms have focused on faults between neighborhood cells, not neighborhood bit-lines. In this paper, a new algorithm for NPSFs, and neighborhood bit-line sensitive faults (NBLSFs) based on the NPSFs are proposed. Instead of the conventional five-cell and nine-cell physical neighborhood layouts to test memory cells, a three-cell layout which is minimum size for NBLSFs detection is used. To consider faults by maximum coupling noise by neighborhood bit-lines, we added refresh operation after write operation in the test procedure(i.e., write \longrightarrow refresh \longrightarrow read). Also, we present properties of the algorithm, such as its capability to detect stuck-at faults, transition faults, conventional pattern sensitive faults, and neighborhood bit-line sensitive faults.

  • PDF

A Study on the Development of Controller which is used Electric Operating Cell(EOC) for Vacuum Circuit Breaker and the Controller Performance Certification Test (진공차단기용 전자식 보조접점 컨트롤러 개발 및 성능인증시험에 관한 연구)

  • Lee, Ki-Seon;Park, Jung-Cheul;Chu, Soon-Nam
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.64 no.3
    • /
    • pp.130-137
    • /
    • 2015
  • This study is about the controller development of the Electric Operating Cell(EOC) which will replace the Mechanical Operated Cell(MOC) of the vacuum circuit breaker which has been used in the power plant and the performance test for the developed controller. The controller developed through this study was manufactured considering the harsh installation environment and electrical condition of the power plant, and the controller performance certification test for confirming the product reliability was taken to know whether or not to withstand fully in various electrical and mechanical problems. Items for performance certification test were AC power frequency voltage withstand test, combined surge immunity test, 1 [MHz] oscillatory SWC test, fast transient SWC test, radiated electromagnetic interference test, vibration test. As a result, all tests has passed an examination without malfunction.

Genetic Evaluation of Somatic Cell Counts of Holstein Cattle in Zimbabwe

  • Mangwiro, F.K.;Mhlanga, F.N.;Dzama, K.;Makuza, S.M.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.13 no.10
    • /
    • pp.1347-1352
    • /
    • 2000
  • The objectives of the study were to examine non-genetic factors that influence somatic cell counts in dairy cattle and to estimate the genetic parameters of somatic cell counts. A total of 34, 097-test day somatic cell count records were obtained from the Zimbabwe Dairy Services Association (ZDSA). The data were from 5, 615 Holstein daughters of 390 sires and 2, 541 dams tested between May 1994 and December 1998. First lactation cows contributed 22, 147 records to the data set, while 11, 950 records were from second and later parity cows. The model for analysis included fixed effects of month of calving, year of calving, stage of lactation, calving interval and test date. Milk yield and age on test day were fitted in the model as covariates. The additive genetic effects pertaining to cows, sires and dams and the residual error were the random effects. The Average Information Restricted Maximum Likelihood algorithm was used for analysis. The heritability of somatic cell scores was low at $0.027{\pm}0.013$ for parity one cows and $0.087{\pm}0.031$ for parity two and above. Repeatability estimates were $0.22{\pm}0.01$ and $0.30{\pm}0.01$ for the two lactation groups, respectively. Genetic and phenotypic correlations between the somatic cell scores and test day milk production were small and negative. It seems that there is no genetic link between somatic cell counts and milk yield in Holstein cattle in Zimbabwe. The results also seem to indicate that somatic cell count is a trait that is mainly governed by environmental factors.

Development and Demonstration of 150W Fuel Cell Propulsion System for Unmanned Aerial Vehicle (UAV) (무인항공기용 150W급 연료전지 동력원 개발 및 실증)

  • Yang, Cheol-Nam;Kim, Yang-Do
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.23 no.4
    • /
    • pp.300-309
    • /
    • 2012
  • Long endurance is a key issue in the application of unmanned aerial vehicles. This study presents feasibility test results when fuel cell system as an alternative to the conventional engine is applied for the power of the UAV after the 150W fuel cell system is developed and packaged to the 1/4 scale super cub airplane. Fuel cell system is operated by dead-end method in the anode part and periodically purged to remove the water droplet in flow field during the operation. Oxygen in the air is supplied to the stack by the two air blowers. And fuel cell stack is water cooled by cooling circuit to dissipate the heat generated during the fuel cell operation. Weight balance is considered to integrate the stack and balance of plant (BOP) in package layout. In flight performance test, we demonstrated 4 times standalone take-off and landing. In the laboratory test simulating the flight condition to quantify the energy flow, the system is analyzed in detail. Sankey diagram shows that electric efficiency of the fuel cell system is 39.2%, heat loss 50.1%, parasitic loss 8.96%, and unreacted purged gas 1.67%, respectively compared to the total hydrogen input energy. Feasibility test results show that fuel cell system is high efficient and appropriate for the power of UAV.

Development and Effects of a Prevention Program for Cell Phone Addiction in Middle School Students (중학생을 위한 휴대전화 중독 예방 프로그램 개발 및 효과 검증)

  • Koo, Hyun-Young
    • Child Health Nursing Research
    • /
    • v.17 no.2
    • /
    • pp.91-99
    • /
    • 2011
  • Purpose: This study was done to develop a cell phone addiction prevention program for middle school students, and to examine the effects of the program on self-esteem, self-efficacy, impulsiveness, and cell phone use. Methods: The study was designed using a nonequivalent control group pre-test-post-test design. The participants were 63 middle school students (31 in the experimental group and 32 in the control group). Students in the experimental group were given the cell phone addiction prevention program. The data were analyzed using the SPSS/WIN 14.0 program. Results: Students in the experimental group reported a significant increase in self-esteem compared to students in the control group. Students in the experimental group also reported a significant decrease in cell phone use compared to students in the control group. Conclusion: The results of the study indicate that the cell phone addiction prevention program was effective in increasing self-esteem and decreasing cell phone use in middle school students.

New electrical test method for LCD cell manufacturing process

  • Miyake, Yasuhiro;Chikamatsu, Kiyoshi;Goto, Masaharu;Mizoguchi, Junichi
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.1451-1454
    • /
    • 2006
  • We propose a new electrical test method bringing repeatable and unambiguous test results eliminating drawbacks of the lighting test for LCD Cell manufacturing process. In this paper, we will show its basic concept, examples of actual test results and effectiveness of the method.

  • PDF

Experimental Study on Carbon Corrosion of Gas Diffusion Layer in PEM Fuel Cell (고분자전해질형 연료전지 가스확산층의 탄소 부식에 관한 실험적 분석)

  • Ha, Taehun;Cho, Junhyun;Park, Jaeman;Min, Kyoungdoug;Lee, Eunsook;Jyoung, Jy-Young
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.76.1-76.1
    • /
    • 2010
  • Recently, many efforts to solve the durability problem of PEM fuel cell are carried on constantly. However, despite this attention, durability researches of gas diffusion layer (GDL) are not much reported yet. Generally, GDL of PEM fuel cell experiences three external attacks, which are dissolution of water, erosion of gas flow, corrosion of electric potential. In this study, among these degradation factors, carbon corrosion of electric potential was focused and investigated with accelerated carbon corrosion test. Through the test, it is confirmed that carbon corrosion occurred at GDL, and corroded GDL decreased a performance of operating fuel cell. The property changes of GDL were measured with various methods such as air permeability meter, pore distribution analyzer, thermo gravimetric analyzer, and tensile stress test to discover the effects of carbon corrosion. Carbon corrosion caused not only loss of weight and thickness, but also degradation of mechanical strength of GDL. In addition, to analysis the reason of GDL property changes, a surface and a cross section of GDL were observed with scanning electron microscope. After 100 hours test, the GDL showed serious damage in center of layer.

  • PDF

A Prediction of Chip Quality using OPTICS (Ordering Points to Identify the Clustering Structure)-based Feature Extraction at the Cell Level (셀 레벨에서의 OPTICS 기반 특질 추출을 이용한 칩 품질 예측)

  • Kim, Ki Hyun;Baek, Jun Geol
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.40 no.3
    • /
    • pp.257-266
    • /
    • 2014
  • The semiconductor manufacturing industry is managed by a number of parameters from the FAB which is the initial step of production to package test which is the final step of production. Various methods for prediction for the quality and yield are required to reduce the production costs caused by a complicated manufacturing process. In order to increase the accuracy of quality prediction, we have to extract the significant features from the large amount of data. In this study, we propose the method for extracting feature from the cell level data of probe test process using OPTICS which is one of the density-based clustering to improve the prediction accuracy of the quality of the assembled chips that will be placed in a package test. Two features extracted by using OPTICS are used as input variables of quality prediction model because of having position information of the cell defect. The package test progress for chips classified to the correct quality grade by performing the improved prediction method is expected to bring the effect of reducing production costs.

An Advanced Correlation Algorithm between GTEM and OATS for Radiated Emission Tests

  • Lee, Ae-Kyoung
    • ETRI Journal
    • /
    • v.17 no.3
    • /
    • pp.45-63
    • /
    • 1995
  • This paper proposes an algorithm to improve the correlation between giga-hertz transverse electromagnetic (GTEM) cell and open area test site (OATS). It is based on the dipole modeling process of an unknown source object in a GTEM cell and on the evaluation of the approximate far field equations correlated with measured GTEM powers at output port of the GTEM cell. In this algorithm, the relative phase differences between dipole moments play an important part in modeling the test object as a set of dipoles and offer stable calculation of emission values. The radiated emission test using this algorithm requires fifteen orientations of equipment under test, but the increased orientations as compared with the previous method have little effect on the time needed for testing. Radiation from a notebook computer has been tested for statistical analysis of the correlation between GTEM data and OATS data. The emission test results of the notebook computer show that the mean, the standard deviation, and the correlation coefficient are -0.62, 1.99, and +0.85, respectively. These figures indicate that this algorithm provides improved accuracy in the measurement of electromagnetic emissions over the previous method.

  • PDF

Design and Performance Evaluation of DC Generator Control System for Cortrolling Torque of Rotating Shaft (회전축의 정밀 토그 발생용 직류 발전기 제어장치의 설계 및 성능평가에 관한 연구)

  • Kim, G.S.;Kang, D.I.;Ahn, B.D.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.11 no.6
    • /
    • pp.50-56
    • /
    • 1994
  • A DC generator control system was designed to control the torque of a rotating shaft precisely. The control system is composed of a strain gage type torque cell, a torque cell amplifier, a computer, a D/A converter, a error detector, a DC voltage amplifier and a resistor. The response test under unit step input and the dynamic stability test for the designed control system were carried out. It was confirmed that the settling time from the response test is about 4 s and the error from the dynamic stability test is less than 0.06% of rated output of torque cell. The designed control system may be used to control a DC generator which may be used to apply torque to a rotating shaft.

  • PDF