• Title/Summary/Keyword: TELEMETRY

Search Result 546, Processing Time 0.034 seconds

Noisy Parameter Estimation of Noisy Passive Telemetry Sensor System using Unscented Kalman Filter (잡음환경에서 UKF를 이용한 원격센서시스템의 파라메타 추정)

  • Kim, Kyung-Yup;Yu, Dong-Gook;Choi, Woo-Jin;Lee, Kwan-Tae;Lee, Joon-Tark
    • Proceedings of the KIEE Conference
    • /
    • 2006.07d
    • /
    • pp.1787-1788
    • /
    • 2006
  • In this paper, a noisy passive telemetry sensor system using Unscented Kalman Filter (UKF) is proposed. To overcome these trouble problems such as a power limitation and a estimation complexity that the general passive telemetry sensor system including IC chip has, the principle of inductive coupling was applied to the modelling of a passive telemetry sensor system (PTSS) and its noisy capacitive parameter was estimated by the UKF algorithm. Specialty, to show the effective tracking performance of the UKF, we compared with the tracking performance of Recursive Least Square Estimation (RLSE) using linearization

  • PDF

Passive Telemetry Capacitive Humidity Sensor System using RLSE Algorithm

  • Lee, Joon-Tark;Park, Young-sik;Kim, Kyung-Yup
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2004.04a
    • /
    • pp.495-498
    • /
    • 2004
  • In this paper, passive telemetry capacitive humidity sensor system using a RLSE(Recursive Least Square Estimation) technique Is proposed. To overcome the problem like power limits and complications that general passive telemetry sensor system including IC chip has, the principle of inductive coupling is applied to model the sensor system. Specially, by applying the forgetting factor, we show that the accuracy of its estimation can be improved even in the case of time varying parameter and also the convergence time can be reduced.

  • PDF

Passive Telemetry Sensor System using RLSE Based Real Time Estimation Technique with Optimal Forgetting Factor

  • Lee, Joon-Tark;Kim, Kyung-Yup
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2004.10a
    • /
    • pp.515-520
    • /
    • 2004
  • In this paper, a passive telemetry RF capacitive humidity sensor system using a RLSE(Recursive Least Square Estimation) technique is proposed. To overcome these trouble problems such as a power limitation and a estimation complexity that the general passive telemetry sensor system including It chip has, the principle of inductive coupling was applied to the modeling of a passive telemetry RF capacitive humidity sensor system and its capacitance was estimatedd by the RLSE algorithm. Specially, by introducing the optimal forgetting factor, we showed that the accuracy of its estimation was improved even in the time varying system and also the convergence time was reduced.

  • PDF

Implementation of four-subject four-channel optical telemetry system with enforced synchronization (강제 동기식 4생체 4채널 광펠레미트리시스템 구현)

  • ;;;M.Ishida
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.35D no.7
    • /
    • pp.40-47
    • /
    • 1998
  • This paper presents the physiological signal processing CMOS one chip for transmitting human bodys small electrical signals such as electrocardiogram(EKG) or electromyogram(EMG) and the external system for receiving signals was implemented by the commercial ICs. For simultaneous four-subject four-channel telemetry, a new enfored synchronization techniqeu using infrared bi-directional communication has been proposed. The telemeter IC with the size of 5.1*5.1mm$^{2}$ has the following functions: receiving of command signal, initialization of internal state of all functional blocks, decoding of subject-selection signal, time multiplexing of 4-channel modulated physiological signals, transmitting of telemetry signal to external system and auto power down control. The newly designed synchronized oscillator with low supply voltage dependence in the telemeter IC operates at a supply voltage from 4.6~6.0V and the nonlinearity error of PIM modulator was less than 1.2%F.S(full scale). The power saving block operates at the period of 2.5ms even if the telemetry IC does not receive command signal from external system for a constant time.

  • PDF

FRONT-END TELEMETRY DATA ACQUISITION UNIT FOR KSLV-I UPPER STAGE

  • Jung Hae-Seung;Kim Joonyun;Lee Jae-Deuk
    • Bulletin of the Korean Space Science Society
    • /
    • 2004.10b
    • /
    • pp.337-340
    • /
    • 2004
  • Upper stage telemetry system of KSLV- I (Korea Space Launch Vehicle I) is composed of MDU (Master Data Unit), RDU (Remote Data Unit), SRU (Shock Recorder Unit) and Transmitter. RDU is the front-end telemetry data acquisition unit which gathers analog/discrete signals from various sensors and other units, and transmits the processed data to MDU via MIL-STD-I553B data bus. In order to acquire useful data from analog signal, signal conditioning circuits, such as anti-aliasing or amplifying, should be implemented. For this purpose, SCM (Signal Conditioning Module) had been developed. This paper describes hardware structure of SCM and analog signal conditioning circuits for various sensors. Also, sampling time scheme for different sampling rates were designed and tested.

  • PDF

The Development of Network-based Telemetry System for Railway Catenary Inspection (전차선로 검측을 위한 네트워크 기반 델레메트리 시스템 개발)

  • Na, Hae-Kyung;Park, Young;Cho, Yong-Hyeon;Park, Hyun-Jun;Choi, Won-Seok;Kim, Eung-Kwon;Song, Joon-Tae
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.478-479
    • /
    • 2007
  • With increasing interest in the reduction of cost for operation and maintenance of overhead catenary system, various methods of condition monitoring have been developed. In this paper, we proposed network-based telemetry system for condition monitoring in railway and acquired data from any kind of sensor in catenary line and structure at high voltage. This development gives the solution for online condition monitoring in railway. To check the validity of our approach in terms of application, we realized network-based telemetry System.

  • PDF

Development of an Airborne Telemetry Relay System Using Aircraft (항공기를 이용한 텔레메트리 신호의 공중 중계시스템 개발)

  • Yeom, Hyeong-Seop;Oh, Jong-Hoon;Sung, Duck-Yong
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.40 no.1
    • /
    • pp.93-100
    • /
    • 2012
  • A telemetry signal occurs the line-of-sight problem by the effect of geography in flight test. A fixed relay system or a mobile relay system is used to solve that problem in general but we propose an airborne telemetry relay system using aircraft in this paper. An airborne telemetry relay system receives the telemetry signal of the test vehicle and then retransmits it to the ground system. The receiving antenna which is a phased array antenna can be tilted to ${\pm}30^{\circ}$ beam direction by beam-forming and track the rapidly moving test vehicle in effect. The relay pod which is mounted to an aircraft consists of the front antenna and the side antenna. It receives S-band signal and then down-converts the frequency to L-band signal. As a result, that can remove the frequency interference on an aircraft while retransmitting.

Telemetry System Encryption Technique using ARIA Encryption Algorithm (ARIA 암호 알고리즘을 이용한 원격측정 시스템 암호화 기법)

  • Choi, Seok-Hun;Lee, Nam-Sik;Kim, Bok-Ki
    • Journal of Advanced Navigation Technology
    • /
    • v.24 no.2
    • /
    • pp.134-141
    • /
    • 2020
  • Telemetry system is a communication system that measures and transmits various signals in the aircraft to the ground for collecting and monitoring flight data during the development of unmanned air vehicle and satellite launch vehicles. With the recent development of wireless communication technology, it is becoming important to apply encryption of telemetry system to prepare with security threats that may occur during flight data transmission. In this paper, we suggested and implemented the application method of ARIA-256, Korean standard encryption algorithm, to apply encryption to telemetry system. In consideration of the block error propagation and the telemetry frame characteristics, frame is encrypted using the CTR mode and can apply the Reed-solomon codes recommended by CCSDS. ARIA algorithm and cipher frame are implemented in FPGA, and simulation and hardware verification system confirmed continuous frames encryption.

Development of A Biotelemetry System for A Totally Implantable Artificial Heart (완전이식 인공심장용 무선정보 전송장치의 개발)

  • Choi, Won-Woo;Kang, Dong-Woo;Park, Seong-Keun;Choi Jae-Soon;Kim, Hee-Chan;Min, Byoung-Goo
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.33B no.1
    • /
    • pp.57-66
    • /
    • 1996
  • In this paper, a new biotelemetry system for a transcutaneous data communication between an implanted artificial heart with a control system and an external human-interfaced management system has been developed. A radio telemetry using radio frequency is a commonly used method in the conventional telemetry systems. But, it is not suitable for the medical applications because of not only an interference due to a radio broadcasting but also a harmfulness to the human body. In this paper, therefore, a new biotelemetry system applied to an artificial heart has been developed with the results of the recent research for an optical telemetry system based on the infrared light transmission with good skin permeability. The performance of the biotelemetry system developed has been assessed through mock circulatory experiments, and the clinical applicability has been also confirmed with the successful results in the animal experiments.

  • PDF