Passive Telemetry Capacitive Humidity Sensor System using RLSE Algorithm

  • Published : 2004.04.01

Abstract

In this paper, passive telemetry capacitive humidity sensor system using a RLSE(Recursive Least Square Estimation) technique Is proposed. To overcome the problem like power limits and complications that general passive telemetry sensor system including IC chip has, the principle of inductive coupling is applied to model the sensor system. Specially, by applying the forgetting factor, we show that the accuracy of its estimation can be improved even in the case of time varying parameter and also the convergence time can be reduced.