• Title/Summary/Keyword: T-test analysis

Search Result 10,833, Processing Time 0.043 seconds

The design of C-GIS and the analysis of its Performance test results (C-GIS의 설계 및 성능평가 결과분석)

  • Shin, Y.J.;Kim, M.H.;Ryu, H.K.;Lee, Y.H.;Kim, C.H.;Kim, J.K.;Kim, K.S.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.551-553
    • /
    • 2002
  • The cubicle type GIS rated at 25.8kV has been designed and manufactured by Jinkwang E&C eacently with their own technologies and KERI's assistances. The C-GIS has been tested to check the design capability for reference before conducting the type test. The operating characteristics test, short time withstand current and peak withstand current test, basic short circuit test duty T60 for preconditioning test, cable charging current switching test, capacitor bank current switching test, basic short circuit test duty T100s and T100a, single phase earth fault test, double earth fault test has been conducted. The test results show that the design and the manufacturing of the C-GIS has an enough capability to pass through the type test except the occurrence of 2 NSDDs in the cable charging current switching test and the instability of opening time at the minimum operating voltage. The problems shown in the tests will be improved soon and the successful pass will be expected in the following type test.

  • PDF

A Diagnosis of Strategy Execution Ability and Corresponding Measures for Korean Oceanic Shipping Companies

  • Ahn, Ki-Myung;Kim, Myung-Jae
    • Journal of Navigation and Port Research
    • /
    • v.34 no.7
    • /
    • pp.595-601
    • /
    • 2010
  • This paper aims to diagnose the strategy execution ability and to provide corresponding measures for Korean oceanic shipping companies. The analysis method is the t-test between importance awareness and Corresponding ability for strategy execution diagnosis index(XPP). According to the diagnosed results, the strategy development is unsatisfactory because the strategy implemented does not adhere to concurrent environmental change. Moreover, the execution of the strategy is also unsatisfactory. Therefore, an evaluation shows that there is a need for a SWOT analysis using BSC, an organization structure to strengthen the strategy execution ability and the support from the market condition analysis prediction center.

Intratester Reliability of 3 Dimensional Motion Analysis System on Normal Subjects by a Tester (3차원 운동분석 시스템을 이용한 보행분석에 있어서 검사간의 재현도)

  • Lee, Moon-Sook;Wui, Hyang-Mi
    • Journal of Korean Physical Therapy Science
    • /
    • v.2 no.1
    • /
    • pp.383-392
    • /
    • 1995
  • The purpose of this investigation was to determine the intratester reliability of measurements obtained with 3 Dimensional Motion Analysis System(3DMAS) by tester on normal subject. Twenty subjects between the ages of 9 and 29(x=22) were evaluated with 3DMAS using a test-retest reliability procedure after a familiarization session. Computerized 3DMAS was done with 4 50 - Hz CCD cameras connected to the ELITE system(B. T. S., Italy) and kinetic data were collected from the AMTI force platform(AMTI., U. S. A). Data were analyzed by the Eliclinic software to obtain gait parameters, joint angles and joint internal moment and power. Test-retest revealed intraclass correlation coefficients from .80 to .99. A series of paired t-tests revealed no significant differences between test and retest values. Finally, it was concluded that tester with 3DMAS could obtain reliable measurements with 3DMAS for determining kinetic, kinematic and gait parameters in normal subjects.

  • PDF

Analysis of Electrical Safety Level Test for Barehand Work at 765kV Vertical Double Circuit Six Bundle Conductors on the Suspension String Tower Type (765kV 수직2회선 6도체 현수형 철탑에서 직접활선작업의 안전성 평가분석)

  • Kim, Dae-Sik;Han, Sang-Ok
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.3
    • /
    • pp.275-278
    • /
    • 2008
  • It has been issued that the necessity of Live line work for 765kV vertical double circuit six bundle conductors transmission line when the characteristics of transmission line, the composition of T/L and near the T/L circumstances etc. Others are considered. The Barehand method of UHV T/L is extremely dangerous work and especially it is directly related with lineman life so it is very dangerous. It should be performed several technology developments for live-line work on the UHV T/L, that should be considered such as the electrical influence on workers near the T/L, development of live-line facilities, guarantee of safety, the technical rules of live-line work, the safe method of live-line work and etc. In order to maintain the 765kV transmission lines safely by barehand work, first of all, we should know the analysis of electrical safety level test in live-line work at 765kV vertical double circuit six bundle conductors on the suspension string tower type.

Application limit of Yield Line Analysis on Welded T-joints in Cold-Formed SHS Sections (냉간성형 각형강관 T형 접합부의 항복선해석 전용한계)

  • Kang, Chang Hoon;Bae, Kyu Woong
    • Journal of Korean Society of Steel Construction
    • /
    • v.16 no.3 s.70
    • /
    • pp.315-324
    • /
    • 2004
  • This study performs a yield line analysis of welded T-joints in cold-formed Square Hollow Sections (SHS) with the branch in axial compression. The existing yield line models proposed by Koto, Packer, Zhao, and CIDECT and the proposed yield line model of the previous study are compared, using the existing test results of welded T-joints in cold-formed SHS. The yield line model suggested in the previous paper, which is based on the simplified yield line analysis, is reviewed to evaluate its application limit on cold-formed SHS T-joints. In the proposed model, the round corner of the cold-formed SHS section and weld size are taken into account. Finally, the validity range of yield line analysis is determined by observing the actual failure modes and comparing the test value with the analysis value, set as ${\beta}^{\prime}{\leq}0.8$ where ${\beta}^{\prime}=0.8$, ${\beta}^{\prime}=b_1^{\prime}/b_0^{\prime}$, $b_1{^{\prime}}=b_1+t_0$ and $b_0{^{\prime}}=b_0-t_0$.

A Study on the Applicability of PDA Technique in the P-CAP System for T-P Removal of STP Effluent (하수처리장 방류수의 총인 제거를 위한 P-CAP 시스템에서 PDA 기법의 활용가능성에 대한 연구)

  • Choi, Choongho;Maeng, Sungkyu;Sim, Jaehwi;Choi, Jinho;Song, Kyungguen;Lee, Byungha;Cha, Hoyoung
    • Journal of Korean Society on Water Environment
    • /
    • v.28 no.5
    • /
    • pp.729-742
    • /
    • 2012
  • Recently, to using chemical coagulation process for T-P removal in STP effluent as tertiary treatment process is generalized in the country. The importance of analysis technique to save the treatment & maintenance cost during coagulation process is becoming more increased each day. Thus, it is necessary for the analysis technique during coagulation process to be presented well the characteristic of coagulation in field apply. There are a few analysis techniques such as Jar Test, zeta potential analysis and streaming current detecting techniques. But there are difficult to apply in field immediately due to long test time and difficult analysis techniques. And using PDA technique, it is reviewed applicability of the techniques as field index on pilot plant of P-CAP system The P-CAP system is composed of an in-line static mixer, a Flocculation Tank and the CAP reactor with 2 stage weir for effluent. Pre-test is performed to fix the mixing velocity in the Flocculation Tank using the PDA equipment and it fixed with 30RPM. Also, Jar Test is performed to select optimum dose of each coagulant for each T-P concentration level of influent. Result of continuous test on pilot plant of P-CAP system, the FSI in the Flocculation Tank is increased consistently by increasing each dosing concentration of coagulant such as LAS and PAC in the low level influent T-P concentration comparatively. It is considered that formed Al-hydroxide complexes for dosed coagulant are caused FSI variation. Furthermore, it seems that FSI value in the high level influent T-P concentration appeared lower than the opposite influent condition relatively because it is formed simultaneously Al-hydroxide complexes as solid type and Al-phosphorus complexes as soluble type. Thus, relation of FSI by PDA technique and T-P removal of final effluent on pilot plant of P-CAP system are very limited for the kind of coagulant and the characteristics of influent. And it though that FSI value by PDA technique with analyzing of turbidity in Flocculation Tank will be used restrictedly on field as the relative field-index.

Analysis and Flight Test Verification of T/A-50 Engine Horsepower Extraction Capability (T/A-50 엔진 축마력(Horsepower) 능력 해석 및 비행시험 검증)

  • 이상효;이부일;정주현;이상백
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.34 no.7
    • /
    • pp.105-111
    • /
    • 2006
  • The aircraft engine is to generate thrust for the maneuver of aircraft and to provide the power to the related hydraulic system and electrical system. Since the power provided to the systems is extracted from the high pressure compressor of aircraft engine, the extracted power is called horsepower extraction (HPX). If the HPX provided from the engine is smaller than the HPX required from the related systems, there could be abnormal engine behavior, like engine rollback or stall. Analysis on comparing the required HPX and the engine HPX capability had been performed during the T/A-50 FSD (Full Scale Development) period. The analysis results make the engine schedule changed, and T/A-50 flight test has been performed with the changed engine schedule. The analysis results and changing the engine control schedule were verified to be valid with the flight test results.

Investigation of the Study Plan and Statistical Method of Functional Cosmetics on Human Skin (기능성 화장품의 인체시험 설계 및 통계적용 방법에 대한 고찰)

  • Seo, Young Kyoung;Koh, Jae Sook;Lee, Won Chul
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.39 no.2
    • /
    • pp.105-115
    • /
    • 2013
  • In Korea, the human skin tests to evaluate the anti-wrinkles and whitening effect have been accomplished in accordance with the KFDA guideline. Regarding the data of the visual assessment and machinery evaluation of the results for the human skin test, unpaired t-test have been used in order to compare between the test and the control groups and paired t-test for the comparison of effects for before and after. Descriptive statistics such as frequency analyses was used for the questionnaire evaluation data. In many cases of the European and American clinical test centers, the methodology and the statistical analysis were similar to ours. But, the documentation obtained by repeated application from identical individual has high relation. For this reason, it is desirable to apply RM ANCOVA and RM ANOVA to a visual assessment and machinery evaluation. We suggested that RM ANCOVA and RM ANOVA is the new approach to statistical analysis of human test data of functional cosmetics.

Effects of the Self-managed Seogeum Therapy among College Students with Allergic Rhinitis (서금요법 자가관리 프로그램이 대학생의 알레르기비염에 미치는 효과)

  • Park, Hong Ju;Kim, Nam Hee
    • Journal of East-West Nursing Research
    • /
    • v.25 no.2
    • /
    • pp.103-116
    • /
    • 2019
  • Purpose: This study investigated the effects of the Seogeum therapy among college students with allergic rhinitis. Method: A non-equivalent control group pretest-posttest non-synchronized design was used. Intervention of Seogeum therapy has been performed from March 2 through March 31, 2017. Sixty college students diagnosed with allergic rhinitis from two different colleges in B and K cities were assigned to the experimental and control group. Data analysis were conducted using descriptive statistics, chi-square test, Fisher's exact test, and t-test. Results: There were significant differences in nose itching (t=4.89, p<.001), sneezing (t=6.26, p<.001), watery rhinorrhea (t= 4.09, p<.001), nasal congestion (t=2.36, p=.022), the percent of eosinophil (t=2.01, p=.049), perceived stress (t=2.05, p=.045), and allergic rhinitis related quality of life (t=4.33, p<.001) between the two groups. However, there were no significant differences in the percent of IgE (t=0.60, p=.553) and level of cortisol (t=0.53, p=.598). Conclusion: The results of this study indicates that the self-management of Seogeum therapy improved physical and psychological status of the college students with allergic rhinitis which ultimately improved their quality of life.

Development and effects of a psychosocial adaptation program for North Korean adolescent defectors

  • Lee, In-Sook;Jeon, Jung-Hee
    • Child Health Nursing Research
    • /
    • v.27 no.3
    • /
    • pp.243-255
    • /
    • 2021
  • Purpose: This study aimed to develop and examine the effects of a psychosocial adaptation program for North Korean adolescent defectors. Methods: This quasi-experimental study was conducted with 28 North Korean adolescent defectors who were recruited through alternative schools. The experimental and control groups consisted of 14 participants each. A program was conducted across eight sessions, each lasting about 90-120 minutes. The data were analyzed using the x2 test, t-test, paired t-test, and analysis of covariance. Results: No significant differences were observed in the score changes for psychosocial adaptation (t=0.25, p=.808), post-traumatic stress symptoms (t=0.32, p=.749), cultural adaptation stress (t=0.05, p=.957), and self-efficacy (t=0.35, p=.726) in either group before and after the intervention. No intergroup differences were observed for psychosocial adaptation (t=0.12, p=.902), post-traumatic stress symptoms (t=0.07, p=.946), cultural adaptation stress (t=0.01, p=.994), and self-efficacy (t=0.58, p=.570). Conclusion: These findings suggest that psychosocial adaptation, stress, and self-efficacy cannot be improved by a short-term intervention program alone. It was also determined that the cultural characteristics of the North Korean adolescent defectors were not sufficiently considered before implementing the program. Therefore, it is essential to provide an in-depth orientation for the participants before implementing the program.