• 제목/요약/키워드: T-plate

검색결과 1,307건 처리시간 0.026초

초등학생 급식 만족과 조리종사자 직무 만족간의 관계 분석 (Relationship between Students' Foodservice Satisfaction and Foodservice Employees' Job Satisfaction at Elementary Schools)

  • 허한나;최항석;이해영
    • 대한영양사협회학술지
    • /
    • 제18권2호
    • /
    • pp.155-169
    • /
    • 2012
  • The purpose of this study was to explore the relationship between student's foodservice satisfaction and foodservice employee's job satisfaction at elementary schools. The survey was conducted on 5th and 6th grade students and foodservice employees at 19 elementary schools in Gwangju, Gyeonggi. Statistical data analysis was completed using SPSS ver. 17.0 for descriptive analysis, frequency analysis, independent sample t-test, and ANOVA. Students were highly satisfied with 'variety of menu' (3.78) and 'food taste' (3.75). The healthy group and no plate waste group showed significantly higher satisfaction levels on seven items, except 'sanitary utensil', as compared to others. Foodservice employees had high levels of satisfaction with human relationships and their jobs, but they were dissatisfied with their wages. Older employees had a high level of satisfaction with 'relationship with a dietitian' (P<0.05), whereas employees with a low level of education exhibited higher 'respect and reflection of his/her opinion on the duty' (P<0.01) and 'current duties' (P<0.05) as compared to others. The group with higher student satisfaction showed significantly higher employee job satisfaction for 11 items, including 'cooperation with co-workers' (P<0.01), 'relationship with a dietitian' (P<0.05), and inversely, the group with higher job satisfaction exhibited significantly higher student foodservice satisfaction for all nine items. Therefore, foodservice satisfaction and job satisfaction have a mutually positive influence on each other.

The Effect of Foot Landing Type on Lower-extremity Kinematics, Kinetics, and Energy Absorption during Single-leg Landing

  • Jeong, Jiyoung;Shin, Choongsoo S.
    • 한국운동역학회지
    • /
    • 제27권3호
    • /
    • pp.189-195
    • /
    • 2017
  • Objective: The aim of this study was to examine the effect of foot landing type (forefoot vs. rearfoot landing) on kinematics, kinetics, and energy absorption of hip, knee, and ankle joints. Method: Twenty-five healthy men performed single-leg landings with two different foot landing types: forefoot and rearfoot landing. A motion-capture system equipped with eight infrared cameras and a synchronized force plate embedded in the floor was used. Three-dimensional kinematic and kinetic parameters were compared using paired two-tailed Student's t-tests at a significance level of .05. Results: On initial contact, a greater knee flexion angle was shown during rearfoot landing (p < .001), but the lower knee flexion angle was found at peak vertical ground reaction force (GRF) (p < .001). On initial contact, ankles showed plantarflexion, inversion, and external rotation during forefoot landing, while dorsiflexion, eversion, and internal rotation were shown during rearfoot landing (p < .001, all). At peak vertical GRF, the knee extension moment and ankle plantarflexion moment were lower in rearfoot landing than in forefoot landing (p = .003 and p < .001, respectively). From initial contact to peak vertical GRF, the negative work of the hip, knee, and ankle joint was significantly reduced during rearfoot landing (p < .001, all). The contribution to the total work of the ankle joint was the greatest during forefoot landing, whereas the contribution to the total work of the hip joint was the greatest during rearfoot landing. Conclusion: These results suggest that the energy absorption strategy was changed during rearfoot landing compared with forefoot landing according to lower-extremity joint kinematics and kinetics.

Micro/Millimeter-Wave Dielectric Indialite/Cordierite Glass-Ceramics Applied as LTCC and Direct Casting Substrates: Current Status and Prospects

  • Ohsato, Hitoshi;Varghese, Jobin;Vahera, Timo;Kim, Jeong Seog;Sebastian, Mailadil T.;Jantunen, Heli;Iwata, Makoto
    • 한국세라믹학회지
    • /
    • 제56권6호
    • /
    • pp.526-533
    • /
    • 2019
  • Indialite/cordierite glass-ceramics demonstrate excellent microwave dielectric properties such as a low dielectric constant of 4.7 and an extremely high quality factor Qf of more than 200 × 103 GHz when crystallized at 1300℃/20 h, which are essential criteria for application to 5G/6G mobile communication systems. The glass-ceramics applied to dielectric resonators, low-temperature co-fired ceramic (LTCC) substrates, and direct casting glass substrates are reviewed in this paper. The glass-ceramics are fabricated by the crystallization of glass with cordierite composition melted at 1550℃. The dielectric resonators are composed of crystallized glass pellets made from glass rods cast in a graphite mold. The LTCC substrates are made from indialite glass-ceramic powder crystallized at a low temperature of 1000℃/1 h, and the direct casting glass-ceramic substrates are composed of crystallized glass plates cast on a graphite plate. All these materials exhibit excellent microwave dielectric properties.

호흡 방법에 따른 한국무용 외발뛰기 동작의 운동역학적 분석 (The Biomechanical Analysis of a One-Legged Jump in Traditional Korean Dance According to Breathing Method)

  • 안주연;이경옥
    • 한국운동역학회지
    • /
    • 제25권2호
    • /
    • pp.199-206
    • /
    • 2015
  • Objective : The purpose of this study was to conduct a biomechanical analysis of a one-legged jump in a traditional Korean dance (Wae Bal Ddwigi) according to breathing method. Method : Participants for this study were 10 dancers with experience for at least 10 years in traditional Korean dance. Independent variables for this test were two different types of breathing methods. Dependent variables were ground reaction force and lower extremity kinematic variables. The jumping movement was divided into three separate stages, take off, flight, and landing. The subjects were asked a questionnaire regarding the degree of impact force and stability of landing posture after the experiment. The Kistler Force Plate (9281B, Switzerland) was used to measure ground reaction force. A digital camera was used to look into angles of each joint of the lower part of body. SPSS was used for statistical analysis via the dependent t-test(p<.05). Results : There were significant differences in jumping according to breathing method. The inhalation & exhalation method yielded significantly longer flight times combined with greater ground reaction force. The breath-holding method required more core flexion during landing, increasing movement at the hips and shoulders. Conclusion : Consequently, there was more flexion at the knee to compensate for this movement. As a result, landing time was significantly higher for breath-holding.

STRAIN ON THE LABIAL PLATES AROUND ABUTMENTS SUPPORTING REMOVABLE PARTIAL DENTURES WITH VARIOUS PROSTHETIC DESIGNS: AN IN VITRO STUDY

  • Kim, Seong-Kyun
    • 대한치과보철학회지
    • /
    • 제43권3호
    • /
    • pp.322-330
    • /
    • 2005
  • Statement of problem. In distal extension removable partial denture, the preservation of health of abutment teeth is very important, but abutment teeth are subjected to unfavorable stress. Purpose. The purpose of this study was to investigate the biomechanical effects of mandibular removable partial dentures with various prosthetic designs using strain gauge analysis. Material and methods. Artificial teeth of both canines were anchored bilaterally in a mandibular edentulous model made of resin. Bilateral distal extension removable partial dentures with splinted and unsplinted abutments were fabricated. Group 1 : Clasp-retained mandibular removable partial denture with unsplinted abuhnents Group 2 : Clasp-retained mandibular removable partial denture with splinted abutments by 6-unit bridge Group 3 : Bar-retained mandibular removable partial denture Strain gauges were bonded on the labial plate of the mandibular resin model, approximately 2 mm close to the abutments. Two vertical experimental loadings (100N and 200N) were applied subsequently via two miniature load cells that were placed at mandibular first molar regions. Strain measurements were performed and simultaneously monitored from a computer connected to data acquisition system. For within-group evaluations, t-test was used to compare the strain values and for between-group comparisons, a one-way analysis of variance (ANOVA) was used and Duncan test was used as post hoc comparisons. Results. Strain values increased as the applied load increased from 100N to 200N for all groups (p<.05). The strain values of group 1 and 2 were tensile under loadings. In contrast, strain values of group 3 were compressive in nature. Under 100N loading, group 1 showed higher strain values than group 3 in absolute quantity (p<.05). Under 200N loading, group 3 showed higher strain values than group 1 and 2 in absolute quantity (p<.05). Group 1 showed higher strain values than group 2 (p<.05). Conclusion. Splinting of two isolated abutments by bridge reduced the peri-abutment strain in comparison with unsplinted abutments. Strain of bar-retained removable partial denture increased much more as applied load increased, but was compressive in nature.

직류전기장에 의한 기포의 변형과 이탈에 관한 연구 (A Study on the Bubble Deformation and Departure Under DC Electric Field)

  • 권영철;김무환;강인석;김석준
    • 대한기계학회논문집
    • /
    • 제19권6호
    • /
    • pp.1518-1528
    • /
    • 1995
  • The deformation and departure processes of a bubble attached to the wall are studied experimentally and numerically to understand the phenomena of the nucleate boiling heat transfer enhancement under DC electric field. An air-bubble is injected in a dielectric liquid with different electric fields generated by changing three types of electrode system (Type 1,2 and 3) in the bubble generator. Experimental variables are the electric field strength and the distance and the shape of the electrodes under DC electric field. From experimental results, it is observed that the bubble under Dc electric field is elongated in the same direction as the electric field and the contact angle increases. For the parallel plate electrode which generates a uniform electric field, bubble departure volume doesn't seem to decrease within our experimental range. However, when a needle is raised a few millimeters from the lower electrode to make a nonuniform electric field around the needle, bubble departure volume decreases continuously with the increase of an applied voltage. The reduction effect of bubble departure volume is the most effective under a strong nonuniform electric field generated with Type 3. As the nonuniformity of the electric field due to the shape of a electrode increases, the terminal velocity and the acceleration of a bubble increase largely. For the comparison with visualization results, the deformation of a bubble attached to the electrode is carried out by a numerical method. Numerical results show good agreement qualitatively with experimental results.

Al 5083O합금의 마찰교반용접부의 조직과 특성평가 (Mechanical Characteristics and Macro-and Micro-structures on Friction Stir Welded Joints with 5083O Al Alloys)

  • 장석기;박종식
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제33권1호
    • /
    • pp.104-111
    • /
    • 2009
  • This paper shows the behaviors of macro- and micro-structures and mechanical properties for specimen's welding region welded by FSW. according to welding conditions with 5mm thickness aluminum 5083O alloy plate. It apparently results in defect-free weld zone in case traverse speed was changed to 32 mm/min under conditions of anti-clockwise direction and tool rotation speed such as 800 and 1250 rpm with tool's pin diameter of 5 ${\Phi}mm$ and shoulder diameter of 20 ${\Phi}mm$, pin length of 4.5 mm and tilting angle of $2^{\circ}$. The ultimate stress of ${\sigma}_T=331$ MPa and the yield point of 147 MPa are obtained at the condition of the travel speed of 32 mm/min with the tool rotation speed of 1250 rpm. There is neither voids nor cracks on bended surface of $180^{\circ}$ after bending test. The improvement of toughness after impact test was found. The lower rotating and traverse speed became, the higher were yield point, maximum stress and elongation(%) with the stresses and the elongation(%) versus the traverse speed diagram. Vickers hardness for cross section of welding zone were also presented. The typical macro-structures such as dynamically recrystallized zone, thermo-mechanically affected zone and heat affected zone and the micro-structures of the transverse cross-section were also showed. However, the author found out that the region of 6mm far away from shoulder circumference was affected by friction heat comprehensively, that is, hardness softened and that part of micro-structures were re-solid-solution or recrystallized, the author also knew that there is no mechanically deformation on heat affected zone but there are the flow of plastic deformation of $45^{\circ}$ direction on thermo-mechanically affected zone and the segregation of Al-Mg on nugget. The solid solution wt(%) of parent material as compared against of friction stir welded zone was comprehensively changed.

구리에 의해 유도된 VBNC 대장균의 특성 (Characterization of Viable But Nonculturable Condition of Escherichia coli Induced with Copper)

  • 구형근;박상열;김숙경
    • 한국미생물·생명공학회지
    • /
    • 제36권3호
    • /
    • pp.209-214
    • /
    • 2008
  • VBNC(Viable but nonculturable)란 생존에 불리한 환경하에서 살아 있으나 일반 영양배지에서 자라지 못하는 미생물의 상태를 나타낸다. 본 연구는 구리를 이용해 Escherichia coli에서 VBNC를 유도하고 이의 특성을 살펴보았다. 구리를 처리한 후 전통적인 평판 배양법에 의한 집락 형성계수(colony forming unit, CFU)를 측정한 결과 배양되지는 않으나, Live/Dead BacLight bacterial viability kit 염색 후 유세포계수기로 측정한 결과 살아있는 미생물로 계수되어 VBNC 상태가 확인하였다. VBNC 유도된 미생물로부터 genomic DNA와 RNA를 분리하고 이들의 안정성을 관찰하였는데 DNA에 비해 RNA의 붕괴가 많이 진행되었음을 확인할 수 있었고 RNA의 붕괴는 특정크기로 붕괴되는 것으로 관찰되었다. 또한 생물전용 투과전자현미경(Bio-Transmission Electron Microscope, Bio-TEM)을 통해 VBNC 세포의 형태를 관찰하였는데 VBNC 상태에서는 정상상태에 비해 periplasmic space가 온전하지 못하고 세포내막과 세포 외막이 분리되었으며 세포질의 양이 현저히 감소됨이 관찰되었다.

도파띠를 이용한 고온 액침 초음파센서의 가능성 연구 (Study on the Feasibility of High-Temperature Immersion Ultrasonic Sensor with a Strip Waveguide)

  • 최명선;이종포;정태언
    • 비파괴검사학회지
    • /
    • 제14권3호
    • /
    • pp.151-156
    • /
    • 1994
  • 액체나트륨 내부에서의 가시화, 온도 혹은 칫수 측정, 용접부의 비파괴검사 등을 위한 고온(약 $250{\sim}650^{\circ}C$) 액침 초음파센서의 개발이 시도되어 왔다. 본 연구에서는 도파띠를 이용한 고온 액침 초음파센서의 가능성을 수조에서 실험으로 확인하였다. 가장 낮은 차수의 반대칭 판파가 분산이 거의 없는 주파수 영역에서 이용되었다. 이 판파는 주파수가 2.3MHz인 빗살구조 탐촉자에 의해 두께가 1mm이고 폭이 13mm인 스테인리스강 도파띠 내에 여기되었다. 이 판파의 감쇠상수는 공기중에서 1.2dB/m이었고, 물속에서는 380dB/m이었다. $13mm{\times}39mm$ 크기의 빔방사부위로부터 270mm 떨어진 평면 반사체에 대해 25dB의 신호 대 잡음 비를 얻었다.

  • PDF

The Expression Patterns of Cdc25A, Cdc25B, Sox2 and Mnb in Central Nervous System in Early Chicken Embryos

  • Zhang, Hui;Qin, Junhui;Cao, Jingjing;Hei, Nainan;Xu, Chunsheng;Yang, Ping;Liu, Haili;Chu, Xiaohong;Bao, Huijun;Chen, Qiusheng
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제22권6호
    • /
    • pp.781-787
    • /
    • 2009
  • The sense and antisense digoxigenin-labeled RNA probes of four genes, Cdc25A, Cdc25B, Sox2 and Mnb, were produced by using SP6 and T7 RNA polymerases, respectively, and in vitro transcription. Expression patterns of the four genes were detected by in situ hybridization in HH (Hamburger and Hamilton) stage 10 chick embryos. In general, expression patterns of the four genes were similar. mRNA of the four genes was mostly restricted to the entire CNS (central nervous system). All were confined to an identical region, neural tube, neural groove and caudal neural plate, corresponding to the notochord or spinal cord, but there was some distinction in specific region or in concentration, for example in somites. The overlap in expression at the same developmental stage in the CNS suggests that the four genes may be functional similar or related in CNS development. Expression patterns of the four genes support specific roles of these regulators in the developing CNS.