• 제목/요약/키워드: T/T probe

검색결과 427건 처리시간 0.024초

Development of the closed-loop Joule-Thomson cryoablation device for long area cooling

  • Lee, Cheonkyu;Park, Inmyong;Yoo, Donggyu;Jeong, Sangkwon;Park, Sang Woo
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제15권3호
    • /
    • pp.40-48
    • /
    • 2013
  • Cryoablation device is a surgical instrument to produce the cooling effect to destroy detrimental biological tissue by utilizing low temperature around 110 K. Usually, this device has the concentrated cooling region, so that it is suitable for concentrated and thick target. Accordingly, it is hard to apply this device for the target which is distributed and thin target. In this study, the design procedure of a closed-loop cryoablation device with multiple J-T expansion part is developed for the treatment of incompetent of great saphenous vein. The developed cyoablation device is designed with the analysis of 1-dimensional (1-D) bio-heat equation. The energy balance is considered to determine the minimum mass flow rate of refrigerant for consecutive flow boiling to develop the uniform cooling temperature. Azeotropic mixed refrigerant R410A and zeotropic mixed refrigerant (MR) of R22 ($CHClF_2$) and R23 ($CHF_3$) are utilized as operating fluids of the developed cryoablation device to form the sufficient temperature and to verify the quality of the inside of cryoablation probe. The experimental results of R410A and the zeotropic MR show the temperature non-uniformity over the range are $244.8K{\pm}2.7K$ and $239.8K{\pm}4.7K$ respectively. The experimental results demonstrate that the probe experiences the consecutive flow boiling over the target range of 200 mm.

빔 틸트 특성을 갖는 광대역 Conformal 패치 어레이 안테나 (Wideband Microstrip Conformal Patch Array Antenna with Tilted Beam)

  • 박정수;김인복;김홍희;이성락;어윤성;김정근
    • 한국전자파학회논문지
    • /
    • 제27권5호
    • /
    • pp.416-423
    • /
    • 2016
  • 본 논문은 광대역 시스템에서 이용 가능한 빔 틸트 특성을 가지는 Conformal 구조의 $1{\times}4$패치 어레이 안테나를 설계 및 제작하였다. E자 형태의 패치 안테나 및 L-probe 급전 방식을 이용하여 광대역 단일 패치를 설계하였고, 전방으로 20도의 빔 틸트 특성을 얻기 위해 $1{\times}4$ 안테나 어레이를 T-junction 전력분배기와 42 psec의 마이크로스트립 전송선을 이용하였다. 3.6~4.4 GHz에서 9 dB 이상의 반사 손실이 측정되었으며, 3.75~4.25 GHz에서 10 dBi 이상의 안테나 이득을 가지며, 30도 이하의 HPBW 특성이 측정되었다.

Unidirectional Photo-induced Charge Separation and Thermal Charge Recombination of Cofacially Aligned Donor-Acceptor System Probed by Ultrafast Visible-Pump/Mid-IR-Probe Spectroscopy

  • Kim, Hyeong-Mook;Park, Jaeheung;Noh, Hee Chang;Lim, Manho;Chung, Young Keun;Kang, Youn K.
    • Bulletin of the Korean Chemical Society
    • /
    • 제35권2호
    • /
    • pp.587-596
    • /
    • 2014
  • A new ${\pi}$-stacked donor-acceptor (D-A) system, [Ru(1-([2,2'-bipyridine]-6-yl-methyl)-3-(2-cyclohexa-2',5'-diene-1,4-dionyl)-1H-imidazole)(2,2':6',2"-terpyridine)]$[PF_6]_2$ (ImQ_T), has been synthesized and characterized. Similar to its precedent, [Ru(6-(2-cyclohexa-2',5'-diene-1,4-dione)-2,2':6',2"-terpyridine)(2,2':6',2"-terpyridine)]$[PF_6]_2$ (TQ_T), this system has a cofacial alignment of terpyridine (tpy) ligand and quinonyl (Q) group, which facilitates an electron transfer through ${\pi}$-stacked manifold. Despite the presence of lowest-energy charge transfer transition from the Ru-based-HOMO-to-Q-based-LUMO (MQCT) predicted by theoretical calculations by using time-dependent density functional theory (TD-DFT), the experimental steady-state absorption spectrum does not exhibit such a band. The selective excitation to the Ru-based occupied orbitals-to-tpy-based virtual orbital MLCT state was thus possible, from which charge separation (CS) reaction occurred. The photo-induced CS and thermal charge recombination (CR) reactions were probed by using ultrafast visible-pump/mid-IR-probe (TrIR) spectroscopic method. Analysis of decay kinetics of Q and $Q^-$ state CO stretching modes as well as aromatic C=C stretching mode of tpy ligand gave time constants of <1 ps for CS, 1-3 ps for CR, and 10-20 ps for vibrational cooling processes. The electron transfer pathway was revealed to be Ru-tpy-Q rather than Ru-bpy-imidazol-Q.

한방부인과 임상실습교육에서 초음파 팬텀의 활용과 효과 (The Use and Educational Effect of Ultrasonic Phantom in Korean Medicine Obstetrics and Gynecology Clinical Practice Education)

  • 양승정;조성희
    • 대한한방부인과학회지
    • /
    • 제35권2호
    • /
    • pp.16-27
    • /
    • 2022
  • Objectives: The purpose of this study is to analyze educational effect of ultrasound examination training with ultrasonic phantom in the department of Korean Medicine Obstetrics and Gynecology. Methods: All 4th grade students in 2021 and 2022 of school of Korean Medicine, Dong-Shin University must be trained in the department of Korean Medicine Obstetrics and Gynecology according to ultrasound examination training guideline including Objective Structured Clinical Examination (OSCE). After completing ultrasound examination training, we distributed questionnaires to them about a confidence before OSCE and after OSCE, difficulty in using ultrasound, ultrasound reading, difficulty with probe manipulation and computer operation, ultrasound understanding, clinical usefulness. And then, we analyzed the related factors including descriptive statistics, frequency analysis, student's t-test and paired t-test by SPSS 12.0. Results: Confidence in using ultrasound showed differences among students by gender and year, but it was not statistically significant. The difficulty of ultrasound use and ultrasound reading was at a moderate level, and the gender difference was not significant, and the difference between the practical students by year was statistically significant. The difficulty of the operation of the ultrasonic probe was at a normal level, and the difference between the students in practice by gender and year was not statistically significant. Although they answered that they had a very good understanding of the use of ultrasound, there was a gender difference and it was statistically significant, and practical students by year was not statistically significant. They answered that the effect on clinical use was very sufficient, but it was not statistically significant. The appropriateness of the practice time was evaluated at a moderate level. Conclusions: The use and educational effect of ultrasound examination using ultrasonic phantom in the department of Korean Medicine Obstetrics and Gynecology clinical practice education was very effective.

RETRIEVAL OF LOCAL INTERPLANETARY DUST EMISSIVITY BY ASTRO-F

  • HONG S. S.;KWON S. M.;PYO J.;UENO M.;ISHIGURO M.;USUI F.;WEINBERG J. L.
    • 천문학회지
    • /
    • 제37권4호
    • /
    • pp.159-169
    • /
    • 2004
  • This is a proposal to probe local part of the interplanetary dust (IPD) cloud complex and retrieve mean volume emissivity of the local IPDs at mid-infrared wavelengths. This will be done by monitoring, with Infrared Camera (IRC) aboard the ASTRO-F, the annual modulation of the zodiacal emission. In pointing mode of the ASTRO-F mission the spacecraft can make attitude maneuvering over approximately ${\pm}1^{\circ}$ range centered at solar elongation $90^{\circ}$ in the ecliptic plane. The attitude maneuvering combined with high sensitivity of the IRC will provide us with a unique opportunity observationally to take derivatives of the zodiacal emission brightness with respect to the solar elongation. From the resulting differential of the brightness over the ${\pm}1^{\circ}$ range, one can directly determine the mean volume emissivity of the local IPDs with a sufficient accuracy to de-modulate the annual emissivity variations due to the Earth's elliptical motion and the dis-alignment of the maximum IPD density plane with respect to the ecliptic. The non-zero eccentricity ($e_{\oplus}$= 0.0167) of the Earth's orbit combined with the sensitive temperature dependence of the Planck function would bring modulations of amplitude at least $3.34\%$ to the zodiacal emission brightness at mid-infrared wavelengths, with which one may determine the IPD temperature T(r) and mean number density n(r) as functions of heliocentric distance r. This will in turn fix the power-law exponent $\delta$ in the relation $T(r) = T_o(r/r_o)^{-\delta}$ for the dust temperature and v in $n(r) = n_o(r/r_o)^-v$ for the density. We discuss how one may de-couple the notorious degeneracy of cross-section, density, reference temperature $T_o$ and exponent $\delta$.

표면 근전도와 전기 탐침기를 이용한 상완이두근의 운동점 표지 비교 연구 (Comparison Study about Surface Mapping of Motor Points in Biceps Brachii Muscle Using Surface EMG and Electric Probe)

  • 박재원;금동호
    • 한방재활의학과학회지
    • /
    • 제28권1호
    • /
    • pp.85-96
    • /
    • 2018
  • Objectives This study was performed to compare the electrical methods of motor points mapping using surface EMG and electric probe (Pointer Excel II). Methods 32 healthy adults (male 16, female 16) were selected. and classified into two groups; surface EMG group, electric probe (Pointer Excel II) group. In surface EMG group, motor points were searched by recoding the compound muscle potentials. In electric probe (Pointer Excel II) group, motor points were searched by scanning the skin with Pointer Excel II at low level stimulation. The locations of the motor points were expressed as X and Y values in relation to the reference line. The horizontal reference line was set as elbow crease and the vertical reference line was set as the line connecting coracoid process to the center of the horizontal reference line. The data was analyzed by 'Independent T-test' and 'equivalence test'. Results 1. The motor points of short head and long head of biceps brachii muscle were located at about 2/3 length of the vertical reference line from coracoid process and about 1/5~1/4 length of the half of the horizontal reference line from the vertical reference line in both group. 2. The motor points of the short head were located more distally and close to the vertical reference line (p<0.001). 3. In surface EMG group, the motor points of the long head were located more laterally in the female than male. And the motor points of the long head were located more distally in the left side than right side (p<0.05). In electric probe (Pointer Excel II) group, similar tendency was observed but there was no statistically significant difference (p>0.05). 4. As a result of the equivalence test between surface EMG group and electric probe (Pointer Excel II) group, the confidence intervals of the difference were within the equivalence limit. Therefore, the locations of the motor points searched by two ways are equa l (p>0.05, equivalence interval=3%). Conclusions The results indicate that electric probe (Pointer Excel II) can be used to search the motor points instead of surface EMG. This might improve the clinical efficiency when using the motor points to treat muscle dysfunction.

공간탐색경로에 따른 3차원 시각구조 도출과 정량적 개방도 측정에 관한 연구 (A Study on the Deduction of 3-Dimmensional Visual Structure and measurement of Quantitative Openness in Accordance with Spatial Probe Routes)

  • 김석태
    • 한국실내디자인학회논문집
    • /
    • 제19권6호
    • /
    • pp.112-120
    • /
    • 2010
  • Human can recognize the environment by detecting spatial perception, and most of environmental perception depends on visual perception. In view that the acquisition of spatial information is accomplished through visual recognition, analysis of visual structure contained in the space is thought to be very important sector in studying the characteristic of the space. The history of studies on visual structure of space, however, wasn't too long, and furthermore most of the theories up to now focused on static and planar principles. Under this circumstance, this study is intended to suggest new theory by combining Isovist theory and VGA theory that have been actively discussed as the theory on visual perception-based spatial structure and supplementing them between each other to expand into 3-dimensional model. The suggested theory is a complex principle in dimensional and dynamic form in consideration of visual direction, which forms 3-dimentional virtual model that enables visualization of the property of spatial structure as the routine discriminating whether visual connection is made between viewing point and target point, and the target point is included in the visual field quadrangular pyramid or not. Such model was built up by an analysis application where four probe paths were applied to simulate the visual structure that occurs in virtual space, and then the characteristics were analyzed through quantification. In result, in spite of the path with equal space and equal length, significant difference in the acquired quantity of spatial information could be found depending on the probe sequence. On the contrary, it was found that probe direction may not affect the acquired quantity of information and visual property of the space.

Duchenne Muscular Dystrophy에 관한 세포유전학 및 분자유전학적 연구 (Cytogenetic and Molecular Genetic Studies on Duchenne Muscular Dystrophy)

  • 홍해숙
    • Journal of Korean Biological Nursing Science
    • /
    • 제7권1호
    • /
    • pp.29-46
    • /
    • 2005
  • Purpose ; 본 연구는 X-염색체와 관련된 장애 중에서 가장 흔하고 심한 Duchenne Muscular Dystrophy(DMD)의 세포유전학 및 분자유전학적 특성을 설명하기 위해서 DMD에 영향을 받고 있는 두 가계의 13명을 대상으로 가계도 분석과 염색체 분석 및 DNA 분석을 하였다. Method ; DNA분석은 DNA probe을 이용한 Southern blotting method로써 RFLPs와 DMD유전자 부위의 exon소실 유무를 조사하여 아래와 같은 결과를 얻었다. Conclusion ; A 염색체 분석 : 말초혈액과 양수를 표본으로 High-Resolution GTG염색에서 A가계와 B가계의 염색체 분석에서 12명의 염색체는 정상 X-염색체였으나 B가계의 I-2(DMD여성)에서 46, x,-x,+t(2:x)(q 21.1 : p21.2)로 나타난다. B. DNA분석3 : 1) RFLPs의 분석 J66,XJ-1.1,754-11로써 B가계의 RELPs(Restriction Fragment Length Polymorphisms)에서 J66/Pst I은 1.7hb(E), 1.6kb(e)을 보여 주었고 XJ-1.1/Taq I은 3.6kb(F), 3.0kb(f), 754-11/EoR I은 4.2kb(G), 2.0kb(g)의 대립인자를 나타내었다. 이상의 결과를 바탕으로 영향을 받고 있는 남자 (II-2)의 haplotype는 보인자인 어머니의 한쪽 인자를 받았으며 어머니와 딸은 보인자이고 임산부의 태아는 남아였고 태아의 인자들은 그의 할아버지로부터 물려받아 DMD에 영향을 받지 않은 것으로 진단되었다. 2) DMD 유전자의 exon 소실에 대한 분석 cDNA probe 8과 cDNA probe 2b-3으로써 소실에 대한 진단은 영향을 받은 남자(II-2)는 cDNA probe 8에서 12, 7.3, 6.6, 4.2kb에 소실이 있고 cDNA 2b-3은 1.7kb에 소실에 나타났다.

  • PDF

PHR 자기센서를 적용한 탐침형 전류 프로브 (A pin type current probe using Planar Hall Resistance magnetic sensor)

  • 이대성;이남영;홍성민;김철기
    • 센서학회지
    • /
    • 제30권5호
    • /
    • pp.342-348
    • /
    • 2021
  • For the characterization or failure analysis of electronic devices such as PCB (printed circuit boards), the most common method is the measurement of voltage waveforms with an oscilloscope. However, because there are many types of problems that cannot be detected by voltage waveform analysis, several other methods such as X-ray transmission, infrared imaging, or eddy current measurement have been applied for these analyses. However, these methods have also been limited to general analyses because they are partially useful in detecting physical defects, such as disconnections or short circuits. Fundamentally current waveform measurements during the operation of electronic devices need to be performed, however, commercially available current sensors have not yet been developed, particularly for applications in highly integrated PCB products with sub-millimeter fine pitch. In this study, we developed a highly sensitive PHR (planar hall resistance) magnetic sensor for application in highly integrated PCBs. The developed magnetic sensor exhibited sufficient features of an ultra-small size of less than 340 ㎛, magnetic field resolution of 10 nT, and current resolution of 1 mA, which can be applicable for PCB analyses. In this work, we introduce the development process of the magnetic sensing probe and its characteristic results in detail, and aim to extend this pin-type current probe to applications such as current distribution imaging of PCBs.

Measurement of the ICRH antenna phasing using antenna strap probe based diagnostic system in EAST tokamak

  • Liu, L.N.;Liang, Q.C.;Yang, H.;Zhang, X.J.;Yuan, S.;Mao, Y.Z.;Zhang, W.;Zhu, G.H.;Wang, L.;Qin, C.M.;Zhao, Y.P.;Cheng, Y.;Zhang, K.
    • Nuclear Engineering and Technology
    • /
    • 제54권10호
    • /
    • pp.3614-3619
    • /
    • 2022
  • To operate the ion cyclotron resonance heating (ICRH) antennas in a better heating state and produce relatively low impurities, it is necessary to control the antenna spectrum by changing the antenna phasing. As the electrical length of the antenna feeding transmission lines is changing as a matter of the standing wave pattern at the ceramic supports, 90° elbows, T-connectors and antenna loops, we chose to measure the current at the grounding points of the antenna loops by antenna strap probe. The voltage drops along a small, several millimeter-long paths at the end of the antenna loops give a signal that is proportional to the current in the antenna loop. Through the simulation of the antenna strap probe and the actual measurement of the antenna phasing under vacuum conditions, the reliability of the antenna strap probe based diagnostic system have been successfully proved. Moreover, this system was successfully applied to the ICRH daily experiments in the spring of 2021. In the near future, the active real-time feedback control of the antenna phasing system will be developed based on this diagnostic system in the EAST tokamak.