Browse > Article
http://dx.doi.org/10.9714/psac.2013.15.3.040

Development of the closed-loop Joule-Thomson cryoablation device for long area cooling  

Lee, Cheonkyu (Cryogenic Engineering Laboratory, Korea Advanced Institute of Science and Technology)
Park, Inmyong (Cryogenic Engineering Laboratory, Korea Advanced Institute of Science and Technology)
Yoo, Donggyu (Cryogenic Engineering Laboratory, Korea Advanced Institute of Science and Technology)
Jeong, Sangkwon (Cryogenic Engineering Laboratory, Korea Advanced Institute of Science and Technology)
Park, Sang Woo (Konkuk University Hospital, School of Medicine, Konkuk University)
Publication Information
Progress in Superconductivity and Cryogenics / v.15, no.3, 2013 , pp. 40-48 More about this Journal
Abstract
Cryoablation device is a surgical instrument to produce the cooling effect to destroy detrimental biological tissue by utilizing low temperature around 110 K. Usually, this device has the concentrated cooling region, so that it is suitable for concentrated and thick target. Accordingly, it is hard to apply this device for the target which is distributed and thin target. In this study, the design procedure of a closed-loop cryoablation device with multiple J-T expansion part is developed for the treatment of incompetent of great saphenous vein. The developed cyoablation device is designed with the analysis of 1-dimensional (1-D) bio-heat equation. The energy balance is considered to determine the minimum mass flow rate of refrigerant for consecutive flow boiling to develop the uniform cooling temperature. Azeotropic mixed refrigerant R410A and zeotropic mixed refrigerant (MR) of R22 ($CHClF_2$) and R23 ($CHF_3$) are utilized as operating fluids of the developed cryoablation device to form the sufficient temperature and to verify the quality of the inside of cryoablation probe. The experimental results of R410A and the zeotropic MR show the temperature non-uniformity over the range are $244.8K{\pm}2.7K$ and $239.8K{\pm}4.7K$ respectively. The experimental results demonstrate that the probe experiences the consecutive flow boiling over the target range of 200 mm.
Keywords
cryoablation device; J-T cooler; mixed refrigerant; closed-loop; great saphenous;
Citations & Related Records
연도 인용수 순위
  • Reference
1 T. M. Flynn, Cryogenic engineering vol. 2: Marcel Dekker New York, 2005.
2 B. Rubinsky, "Cryosurgery," Annual Review of Biomedical Engineering, vol. 2, pp. 157-187, 2000.   DOI   ScienceOn
3 R. Radebaugh, "Heat Transfer Issues in Cryogenic Catheters," in Microscale Heat Transfer Fundamentals and Applications, ed, Springer, pp. 445-464, 2005.
4 K. J. Chua, S. K. Chou, and J. C. Ho, "An analytical study on the thermal effects of cryosurgery on selective cell destruction," J Biomech, vol. 40, pp. 100-16, 2007.   DOI   ScienceOn
5 K. Fredrickson, G. Nellis, and S. Klein, "A design method for mixed gas Joule-Thomson refrigeration cryosurgical probes," International Journal of Refrigeration, vol. 29, pp. 700-715, 2006.   DOI   ScienceOn
6 T. M. Klem, J. M. Schnater, P. R. Schutte, W. Hop, A. C. van der Ham, and C. H. Wittens, "A randomized trial of cryo stripping versus conventional stripping of the great saphenous vein," J Vasc Surg, vol. 49, pp. 403-9, 2009.   DOI   ScienceOn
7 R. J. Min, S. E. Zimmet, M. N. Isaacs, and M. D. Forrestal, "Endovenous Laser Treatment of the Incompetent Greater Saphenous Vein," Journal of Vascular and Interventional Radiology, vol. 12, pp. 1167-1171, 2001.   DOI   ScienceOn
8 B. C. Disselhoff, E. Buskens, J. C. Kelder, D. J. der Kinderen, and F. L. Moll, "Randomised comparison of costs and cost-effectiveness of cryostripping and endovenous laser ablation for varicose veins: 2-year results," Eur J Vasc Endovasc Surg, vol. 37, pp. 357-63, 2009.   DOI   ScienceOn
9 P. W. Mikus and J. J. Eum, "Cryoprobe system," ed: Google Patents, 2001.
10 R. B. Coleman and R. N. Richardson, "A novel closed cycle cryosurgical system," International Journal of Refrigeration, vol. 28, pp. 412-418, 2005.   DOI   ScienceOn
11 M. Gong, Z. Sun, J. Wu, Y. Zhang, C. Meng, and Y. Zhou, "Performance of R170 mixtures as refrigerants for refrigeration at $-80^{\circ}C$ temperature range," International Journal of Refrigeration, vol. 32, pp. 892-900, 2009.   DOI   ScienceOn
12 E. W. Lemmon, M. L. Huber, and M.O.McLinden, "NIST Standard Reference Database 23: Reference fluid thermodynamic and transport properties-REFPROP," 9.0 ed. Gaithersburg: National Institute of Standards and Technology, Standard Reference Data Program, 2010.
13 J. Okajima, S. Maruyama, H. Takeda, A. Komiya, and S. Jeong, "Cooling Characteristics of Ultrafine Cryoprobe Utilizing Convective Boiling Heat Transfer in Microchannel," presented at the 14th International Heat Transfer Conference, ASME, Washington D.C., USA, 2010.
14 A. Shitzer and R. C. Eberhart, Heat transfer in medicine and biology: analysis and applications vol. 2: Plenum Pub Corp, 1985.
15 F. P. Incropera, A. S. Lavine, and D. P. DeWitt, Fundamentals of heat and mass transfer: John Wiley & Sons Incorporated, 2011.
16 Y. A. Cengel and M. A. Boles, Thermodynamics: an engineering approach: McGraw-Hill Higher Education, 2006.
17 F. M. White, "Fluid Mechanics. 5th," Boston: McGraw-Hill Book Company, 2003.