• Title/Summary/Keyword: System Safety Process

Search Result 2,427, Processing Time 0.033 seconds

Developing Advanced Total Recycling Method of FRP Boats (FRP선박의 일괄 재처리 방법의 개선)

  • Lee, Seung Hee;Yoon, Koo Young
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.16 no.1
    • /
    • pp.53-59
    • /
    • 2013
  • Since 1990s, the major recycling methods for mechanical recycling of FRP(Fiber Reinforced Plastics)boats has involved shredding and grinding of the scrap FRP in a new recycled product. But still it leads to secondary problem such as air pollution, unacceptable shredding noise level and few limited applications. This study is to propose a newly advanced method which is more efficient and environment friendly waste FRP regenerating system. As extracting FRP layer and making the recycled fiber for recycled-fiber reinforced concrete(RFRC) from waste FRP, the recycling process has some merits in a sense of the recycling energy and the environmental effects. In this study, for those tasks, spectro-chemical differentiation method and coloring water-soluble dye treatment makes the roving layer more distinguishable photophysically. Also that has remarkably reduced safety hazards and energy. Using the mechanical properties of polymers and composite, FRP with the orthotropic and laminated plastic structure has been easily separated in the new extracting system. Also the new method has introduced five kind of separating manuals for the some different compositions of FRP boats. The roving fiber of laminated glass-fiber layer is as good as the polyvinyl fiber which is cost-high commercial fiber to increasing strength of concrete products. The early study has shown the effectiveness of laminated glass-fiber layer which also is chemical-resistant due to the resin coating. These results imply that more efficient and environment friendly recycled glass fiber can be better applied to the fiber reinforced concrete(FRC) substitute and this study also has shown wide concrete applications with RFRC from the waste FRP boat.

Childcare Teacher's Perception of the Accreditation System Based on Accreditation Experience -Focused on the Second Accreditation Index of Childcare Centers- (보육교사의 평가인증 경험에 따른 평가인증제에 대한 인식비교 -2차 평가인증지표를 중심으로-)

  • Cho, Hyun-Ok;Choi, Inhwa
    • Korean Journal of Childcare and Education
    • /
    • v.7 no.4
    • /
    • pp.301-324
    • /
    • 2011
  • The purpose of this study was to examine the perception of the childcare teachers regarding accreditation procedures and feasibility of the second accreditation index according their past participation in the accreditation process. The objects were 193 childcare teachers working at child care centers that were accredited using the initial accreditation index. The collected data was analyzed using frequency, percentile, $X^2$, and t-test. The major findings are as follows: First, childcare teachers without accreditation experience perceived 'continuing education of child care center directors and teachers' to be the most important for quality maintenance after successful accreditation. In contrast, childcare teachers with accreditation experience placed the most importance on 'childcare teachers' motivation and continuing enrollment'. Second, childcare teachers with accreditation experience perceived higher feasibility in the subcategories of 'art activity materials' in the category of child care environment, 'providing operation policies and information of child care teachers', 'care for children', and 'employment contract' in the operation & management category, 'sanitary management of food, cooking and feeding', 'care of sick or injured child', 'health management of children and childcare teachers', 'snacks for children' in the category of health and nutrition and 'safe procedures for handing over children' in the category of safety. In general, childcare teachers with accreditation experience perceived higher feasibility of the second accreditation index in all categories.

Follow-Up Survey Fire Truck Deterioration (소방자동차 노후화에 따른 고장 발생원인 추적조사 연구)

  • Lee, Jang-Won;Kim, Eui-Tae;Rie, Dong-Ho
    • Fire Science and Engineering
    • /
    • v.29 no.3
    • /
    • pp.59-64
    • /
    • 2015
  • This study analyzed results of the causes of failure in 1,022 fire trucks currently being used in South Korea (aerial ladder, aerial platform, pumper, and chemical fire trucks). The results show that 46% of aerial ladder trucks have defective in the elevator brake systems, 29% of aerial platform trucks have contamination in the hydraulic oil, 37% of pumpers have defective in the pneumatic cylinders of the air supply system, and 39% of chemical fire trucks have defective in the powder fire extinguishing systems. The principal reasons for malfunctions are deterioration of the apparatuses, and accumulated fatigue from repetitive use of certain components, such as pneumatic cylinders in the air supply system and wire rope jamming in rollers in the ladder apparatus. These manufacturing defects should be improved upon in the manufacturing process. As a result, the fire trucks, which are used for 5 years or more, need precise inspections in accordance with the Regulation on Fire Apparatus Maintenance. Fire apparatuses have a service life of 10 to 12 years or more. They need to be replaced or require life extension, and they should be kept in top shape with the best maintenance for public safety.

Effective Components of Commercial Enzyme Food Products and Their HACCP Scheme (시판 효소식품의 유용성분과 HACCP 관리 방안에 관한 연구)

  • Lee, Eun-Joo;Lee, Cherl-Ho
    • Korean Journal of Food Science and Technology
    • /
    • v.33 no.4
    • /
    • pp.461-468
    • /
    • 2001
  • The effectiveness and safety of Enzyme Food, a group of dietary supplements designated by Korean Food Law, were evaluated and the possibility of HACCP (Hazard Analysis Critical Control Point) application was investigated. Chemical composition, enzyme activities and the degree of bacterial contamination in 12 samples of different brands sold in Korean market were measured. The chemical composition of the selected products varied and inconsistent to those claimed in the label description. It is known that effectiveness of Enzyme Food depends on enzyme activity, but enzyme activities of ${\alpha}-amylase$ varied from $1,793\;{\mu}g/min$ g to $159\;{\mu}g/min$ g and those of ${\beta}-amylase$ ranged from $171\;{\mu}g/min$ g to $11\;{\mu}g/min$ g. The protease activities varied from $27.57\;{\mu}g/min$ g to $0.18\;{\mu}g/min$ g. In coli-form bacterial test, positive reactions were appeared in the 50 % of the samples. Numbers of bacteria ranged from $1.3\;{\times}\;10^5\;to\;1.2\;{\times}\;10^9$. Five CCPs were identified; heating, inoculation, cultivation, drying and granulation. Consideration of HACCP system indicated that the pretreatment of raw material, checking of bacterial contamination and stability of enzyme activity during fermentation process were important factors for the quality of Enzyme Foods.

  • PDF

Developing status of the Preparedness and Response System for HNS accident (HNS 해상사고 대비.대응체제구축 추진현황)

  • Im, T.S.;Lee, S.H.;Choi, J.W.
    • Proceedings of KOSOMES biannual meeting
    • /
    • 2006.05a
    • /
    • pp.65-70
    • /
    • 2006
  • The regulation of HNS has been intensified by the international trends including OPRC-HNS Protocol and '96 Convention which was driven by the high amounts of cargo. Due to the characteristics of HNS that would possibly bring potential damage with personnel and assets, effective management and prompt actions are required definitely. In order to respond effectively against HNS accidents, Korea Coast Guard (KCG) is in the process q development of HNS accident response manual and information system which allows On-Scene Coordinator(OSC) and personnels for rescue including an information for hazardous materials, sensitive area to be affected, solution methods and more. Furthermore, KCG is also building up establishment of national and local contingency plans for HNS in accordance with OPRC-HNS Protocol. It is also advised to proceed for the government to solve the anticipated obstacles that include protection equipments to get close to the site, experts allowing to manage accidents and organizations specialized for overall HNS related matters. The proposed issues described above are planned to conducted on basis of government.

  • PDF

Development of Autonomous Vehicle Learning Data Generation System (자율주행 차량의 학습 데이터 자동 생성 시스템 개발)

  • Yoon, Seungje;Jung, Jiwon;Hong, June;Lim, Kyungil;Kim, Jaehwan;Kim, Hyungjoo
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.19 no.5
    • /
    • pp.162-177
    • /
    • 2020
  • The perception of traffic environment based on various sensors in autonomous driving system has a direct relationship with driving safety. Recently, as the perception model based on deep neural network is used due to the development of machine learning/in-depth neural network technology, a the perception model training and high quality of a training dataset are required. However, there are several realistic difficulties to collect data on all situations that may occur in self-driving. The performance of the perception model may be deteriorated due to the difference between the overseas and domestic traffic environments, and data on bad weather where the sensors can not operate normally can not guarantee the qualitative part. Therefore, it is necessary to build a virtual road environment in the simulator rather than the actual road to collect the traning data. In this paper, a training dataset collection process is suggested by diversifying the weather, illumination, sensor position, type and counts of vehicles in the simulator environment that simulates the domestic road situation according to the domestic situation. In order to achieve better performance, the authors changed the domain of image to be closer to due diligence and diversified. And the performance evaluation was conducted on the test data collected in the actual road environment, and the performance was similar to that of the model learned only by the actual environmental data.

Understand the Current Status of Teaching and Learning Informatization and Develop Indicators in the 4th Industrial Revolution (4차산업혁명 시대를 대비한 대학의 교수학습 정보화 현황 파악 및 지표 개발)

  • Kim, Sang-Woo;Lee, Myung-Suk
    • Journal of Digital Convergence
    • /
    • v.18 no.4
    • /
    • pp.67-74
    • /
    • 2020
  • The purpose of this study has developed a teaching and learning informatization indicator that provides the basis for utilizing or disseminating the beneficial teaching and learning informatization environment promoted by each university. The research method analyzes various informatization indicators developed by KERIS from 2002 to 2015 and recent environment such as Edutech, future education report, teaching and learning field report, and reflects them in indicator development. The development of the third indicator was completed by dividing it into Input, Process, Output stages by reflecting expert opinions in the first and second indicators. As a result, the core words of the university's teaching-learning informatization infrastructure building, sharing of educational resources, open development and sharing, joint purchase of resources, information safety system and literacy education, current status grasping, and resource utilization were derived. In the future, I will fill out the questionnaire to supplement the question through a pilot test and to grasp the current status of teaching and learning informatization in the entire university.

A Comparison Study of Model Parameter Estimation Methods for Prognostics (건전성 예측을 위한 모델변수 추정방법의 비교)

  • An, Dawn;Kim, Nam Ho;Choi, Joo Ho
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.25 no.4
    • /
    • pp.355-362
    • /
    • 2012
  • Remaining useful life(RUL) prediction of a system is important in the prognostics field since it is directly linked with safety and maintenance scheduling. In the physics-based prognostics, accurately estimated model parameters can predict the remaining useful life exactly. It, however, is not a simple task to estimate the model parameters because most real system have multivariate model parameters, also they are correlated each other. This paper presents representative methods to estimate model parameters in the physics-based prognostics and discusses the difference between three methods; the particle filter method(PF), the overall Bayesian method(OBM), and the sequential Bayesian method(SBM). The three methods are based on the same theoretical background, the Bayesian estimation technique, but the methods are distinguished from each other in the sampling methods or uncertainty analysis process. Therefore, a simple physical model as an easy task and the Paris model for crack growth problem are used to discuss the difference between the three methods, and the performance of each method evaluated by using established prognostics metrics is compared.

Development of a Hospital Foodservice Facility Plan and Model based on General Sanitation Standards and RACCP Guidelines (병원급식에 일반위생관리기준과 HACCP 제도 적용을 위한 시설모델 개발)

  • 이정숙;곽동경;강영재
    • Korean journal of food and cookery science
    • /
    • v.19 no.4
    • /
    • pp.477-492
    • /
    • 2003
  • The purposes of the study were to establish HACCP-based standards and guidelines for conducting a plan review to build, or renovate, hospital food service establishments, and ensure the safety of foodservice and reduce the risk of food borne illness. The scope of the study included suggestion for the planning of hospital foodservice facilities: layout, design, equipment and modeling. The results of this study can be summarized as follows: 1) The development of a foodservice facility plan based on the results of a survey, literature reviews and the results of interviews with foodservice managers from 9 general hospitals. This was composed of operational policies in foodservices, layout characteristics, space allocation, selection, design, specification standards for equipment and the construction principles of foodservice facilities. 2) Two foodservice facility models were developed, one for general hospitals with 900 beds (2,000 patients and 2,500 employee meals per day) and the other for general hospitals with 300 beds (600 patients and 650 employees meals per day). 3) The suggested kitchen space requirements for the foodservice facility models were 341.2 ㎡ (W 17,100mm x L 23,700mm) and 998.8㎡ (W 35,600mm x L 32,800mm) for the 300 and 900 beds hospitals, respectively, with both designs being rectangular. The space requirements for the equipment, in relation to the total operational area, in terms of ratios were 1:3.5 and 1:3.8 for the 300 and 900 beds hospitals, respectively. The recommended space allowances per bed for the developed foodservice facility models were 1.15 ㎡ and 1.11 ㎡ for the 300 and 900 beds hospitals, respectively, which were increased by more than 30% compared to those suggested in the precedent study, and considered appropriate for the implementation of the HACCP system. 4) The hospital foodservice facilities plans and models were developed based on the general sanitation standards, guidelines and the HACCP system, and included foodservice facility layout, product flow, physical separation between contaminated and sanitary areas, foodservice facility specifications with a 1/300 scale for a 300 bed, and a 1/400 scale for a 900 beds blueprint. 5) The main features of the developed foodservice facility plans and models were; physical separation between contaminated and sanitary areas to prevent cross contamination, product flow in one direction from the arrival of the raw material to the finished product, and separation of different work areas and the process of receiving & preparation of products, refrigeration & storage, cooking, assembly, cleaning & disinfection, employee areas and janitorial facilities. The proposed models from this study were presented as examples for those wanting to build, or renovate, their facility for the production of foods.

Effect of Period of Immersion on Corrosion Potential, Anodic Polarization, and Impedance Characteristics of Reinforced Steel in Mortar (W/C: 0.6) (모르타르(W/C:0.6)의 철근의 부식전위와 양극분극 및 임피던스 특성에 미치는 재령 년수)

  • Jeong, Jae-Hyun;Moon, Kyung-Man;Lee, Sung-Yul;Lee, Myeong-Hoon;Baek, Tae-Sil
    • Journal of Ocean Engineering and Technology
    • /
    • v.30 no.4
    • /
    • pp.327-333
    • /
    • 2016
  • Reinforced concrete structures have found wide usage in land and maritime applications. However, the corrosion of reinforced concrete has been recognized as a serious problem from economic and safety standpoints. In previous studies, the corrosion behavior of the inner steel bar embedded in mortar (W/C: 0.4, 0.5) was investigated using electrochemical methods. In this study, multiple mortar test specimens (W/C: 0.6) with six different cover thicknesses were prepared and immersed in flowing seawater for five years. Subsequently, equations related to the cover thickness, period of immersion, and corrosion characteristics of the embedded steel bar were evaluated using electrochemical methods. Prior to immersion, the corrosion potentials indicated an increase with increasing cover thickness, and after five years, all corrosion potentials demonstrated a trend in the positive direction irrespective of the cover thickness. However, the relationships between the corrosion potential and cover thickness were not in complete agreement. Furthermore, after five years, all of the corrosion potentials indicated values that were nobler compared to those obtained prior to immersion, and their corrosion current densities also decreased compared to their values obtained prior to immersion. It was considered that the embedded steel bar was easily corroded because of the aggression of water, dissolved oxygen, and chloride ions; a higher W/C ratio also assisted the corrosion process. The corrosive products deposited on the surface of the steel bar for five years cast a resistance polarizing effect shifting the corrosion potential in the nobler direction. Consequently, it was considered that the W/C ratio of 0.6 showed nearly same results as those of W/C of 0.4 and 0.5. Therefore, the corrosion potential as well as various parameters such as the cover thickness, period of immersion, and W/C ratio must be considered at once for a more accurate evaluation of the corrosion property of reinforced steel exposed to marine environment for a long period.