• Title/Summary/Keyword: System Compatibility

Search Result 1,011, Processing Time 0.028 seconds

EFFECT OF AN INTERMEDIATE BONDING RESIN AND FLOWABLE RESIN ON THE COMPATIBILITY OF TWO-STEP TOTAL ETCHING ADHESIVES WITH A SELF-CURING COMPOSITE RESIN (자가 중합 복합 레진과 두 단계 산 부식 접착제의 친화성에 대한 중간 접착제와 흐름성 레진의 효과)

  • Choi, Sook-Kyung;Yum, Ji-Wan;Kim, Hyeon-Cheol;Hur, Bock;Park, Jeong-Kil
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.5
    • /
    • pp.397-405
    • /
    • 2009
  • This study compared the effect of an activator, intermediate bonding resin and low-viscosity flowable resin on the microtensile bond strength of a self-curing composite resin used with two-step total etching adhesives. Twenty extracted permanent molars were used. The teeth were assigned randomly to nine groups (n=10) according to the adhesive system and application of additional methods (activator, intermediate adhesive, flowable resin). The bonding agents and additional applications of each group were applied to the dentin surfaces. Self-curing composite resin buildups were made for each tooth to form a core, 5mm in height. The restored teeth were then stored in distilled water at room temperature for 24h before sectioning. The microtensile bond strength of all specimens was examined. The data was analyzed statistically by one-way ANOVA and a Scheffe's test. The application of an intermediate bonding resin (Optibond FL adhesive) and low-viscosity flowable resin (Tetric N-flow) produced higher bond strength than that with the activator in all groups. Regardless of the method selected, Optibond solo plus produced the lowest ${\mu}TBS$ to dentin. The failure modes of the tested dentin bonding agents were mostly adhesive failure but there were some cases showed cohesive failure in the resin.

Implementation and Performance Evaluation of Transaction Protocol for Wireless Internet Services (무선 인터넷 서비스를 위한 트랜잭션 프로토콜의 구현과 성능평가)

  • Choi, Yoon-Suk;Lim, Kyung-Shik
    • Journal of KIISE:Information Networking
    • /
    • v.29 no.4
    • /
    • pp.447-458
    • /
    • 2002
  • In this paper, we design and implement Wireless Transaction Protocol(WTP) and evaluate it for wireless transaction processing in mobile computing environments. The design and implementation of WTP are based on the coroutine model that might be suitable for light-weight portable devices. We test the compatibility between our product and the other products such as Nokia, Kannel and WinWAP For the evaluation of WTP, we use an Internet simulator that can arbitrary generate random wireless errors based on the Gilbert model. In our experiment, the performance of WTP is measured and compared to those of Transmission Control Protocol(TCP) and TCP for Transactions. The experiment shows that WTP outperforms the other two protocols for wireless transaction processing in terms of throughput and delay. Especially, WTP shows much higher performance In ease of high error rate and high probability of burst errors. This comes from the fact that WTP uses a small number of packets to process a transaction compared to the other two protocols and introduces a fixed time interval for retransmission instead of the exponential backoff algorithm. The experiment also shows that the WTP performance is optimized when the retransmission counter is set to 5 or 6 in case of high burst error rate.

Analysis on Compatibility between wireless headset and WiFi in ISM bands (ISM 대역에서 무선 헤드셋과 WiFi 간의 양립성 분석)

  • Cho, In-Kyoung;Kim, Tae-Youn;Jang, Jae-Woong;Jang, Kyung-Duk;Moon, Guee-Won
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.2
    • /
    • pp.272-278
    • /
    • 2015
  • This paper analyzed interference impact between wireless headset and Wireless Fidelity which get a high possibility of simultaneously operating in the Industry Science Medical(ISM) bands. Analysis methods of Minimum Coupling Loss(MCL) and Monte Carlo(MC) were applied by using the characters and parameters referenced to Institute of Electrical and Electronic Engineers(IEEE) 802.11b. The protection distance between interferer (WiFi transmitter) and victim (Wireless headset receiver) was calculated through the MCL. The protection distance was obtained for the case of single interferer, and the maximum allowable number of multiple interferers was computed according to the cell radius of a victim system to meet 5 % below of interference probability by using a statistical analysis based on the MC method. The analysis results are expected to be used as a guideline to coexist the wireless headset and low power devices in the ISM band.

Shear bond strength between universal adhesives with various pH and dual-cured resin cements (다양한 pH를 가지는 Universal adhesives와 이원 중합 레진 세멘트 간의 전단결합강도)

  • Kwon, Sung-Joo;Park, Jeong-Kil;Son, Sung-Ae
    • Korean Journal of Dental Materials
    • /
    • v.45 no.4
    • /
    • pp.301-310
    • /
    • 2018
  • The purpose of this study is to evaluate the compatibility of universal adhesives with two dual-cured resin cements. Eighty human molars were divided into eight groups. Tooth was embedded in self-curing acrylic resin and sectioned horizontally to exposure dentine surface. After polishing with 600-grit SiC paper, adhesives were applied. All-Bond Universal (Bisco), G-premio bond (GC), Scotch-bond universal (3M ESPE), Scotch-bond Multipurpose (3M ESPE) were used in this study. Calibra (Dentsply) as a conventional dual-curing resin cement and RelyX Ultimate (3M ESPE) as an amine free resin cement were used. The adhesives and the cements were applied according to the manufacturer's instructions. Final specimens were cylinder (diameter 2mm, height 3mm) shape. After storing in distilled water at $37^{\circ}C$ for 7 days the shear bond strength (SBS) test was performed. There was no significant difference in shear bond strength between the adhesives when RelyX Ultimate was used (p>0.05). However, when Calibra used with Scotch-bond Multipurpose and All-Bond Universal were used, statistically higher SBS was observed, as compared to the groups which Calibra cements with G-premio bond and Scotch-bond universal adhesive (p<0.05) were used. Within the limitations of this study, RelyX Ultimate resin cement was compatible with universal adhesives of various pH. All-Bond Universal adhesive was compatible with a resin cement containing the tertiary amine.

Neutral zone approach and external impression for rehabilitation of severely atrophic maxillary and mandibular ridges: a case report (치조제 흡수가 심한 무치악 환자에서 중립대 및 연마면 인상을 통한 총의치 수복 증례)

  • Jo, Yujin;Ko, Chang-woo;Park, Sang-Won;Yun, Kwi-Dug;Park, Chan;Lim, Hyun-Pil
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.34 no.4
    • /
    • pp.324-330
    • /
    • 2018
  • In order to produce a stable denture for severe alveolar bone loss area, it is not only important that .0a suitable occlusion is established but also to consider compatibility with the surrounding muscle to form a suitable polished surfaces. Neutral zone is defined as a potential area where the neuromuscular system of the tongue, cheeks and lips is balanced can be determined through the neutral zone impression technique. And if artificial teeth are aligned within the neutral zone and the polished surface follows the anatomical form of the dynamic muscle, higher stability and retention of the denture may be obtained through coordination with the surrounding muscle tissue. This case is being reported since the concept of the neutral zone was applied to a patient with severely atrophic residual alveolar ridge and the result was clinically satisfactory in both function and aesthetics.

Effect of Characterisitcs of Service Quality on Continuance Usage Intention of Digital Healthcare Service Using Mediating Factors of User Expectation and User Utility (디지털헬스케어서비스에서 서비스품질 속성이 지속사용의도에 미치는 효과연구: 사용자기대와 사용자효용 매개요인을 중심으로)

  • Jeon, Eun-Seon;Kim, Chul Soo
    • The Journal of Society for e-Business Studies
    • /
    • v.26 no.2
    • /
    • pp.1-17
    • /
    • 2021
  • This paper elucidates the effect of characteristics of service quality on continuance usage intention of digital healthcare service using mediating factors of user expectation and user utility. First, we classified independent factors into three types such as service system characteristics, user characteristics, and healthcare service characteristics from the previous studies, and investigated the effect of three independent factors on continuance usage intention of digital healthcare service. Second, we analyzed the impact of two mediating factors, user expectation and user utility, on the continuance usage intention. We developed a research model that includes three types of independent factors, mediated factors of user expectation and user utility, and a dependent factor of continuance usage intention. We surveyed a total of 357 samples from digital healthcare service users and analyzed the research model. The research results significantly show that Characteristics of Users is essential factor impacting a dependent factor of Continuance Usage Intention. The results indicate the followings: (1) Characteristics of Users including the variables of Innovation impacts User Expectation, and User Expectation affects Users Utility, and Users Utility also affects Continuance Usage Intention. (2) Characteristics of Service Systems including the variables of Functionality, Compatibility, and Convenience and Characteristics of users of Innovation variable impact the mediating factor of User Expectation, and User Expectation also affects the factor of Continuance Usage Intention. (3) Characteristics of Healthcare Services including the variables of Reliability, Ease of Operation, Safety, and Accuracy impact User Utility, and User Utility also affects Continuance Usage Intention.

Effect of Amino Modified Siloxanes with Two Different Molecular Weights on the Properties of Epoxy Composites for Adhesives for Micro Electronics (전자소재 접착제용 에폭시에 두 종의 다른 당량수를 갖는 아미노 변성 실록산이 미치는 영향)

  • Yu, Kihwan;Kim, Daeheum
    • Applied Chemistry for Engineering
    • /
    • v.22 no.1
    • /
    • pp.104-108
    • /
    • 2011
  • In the non-conductive adhesives (NCAs) for adhesion of micro electro mechanical system (MEMS), there are some problems such as delamination and cracking resulting from the large differences of coefficients of thermal expansion (CTE) between NCAs and substrates. So, the addition of inorganic particles such as silica and nano clay to the CTEs composit have been applied to reduce the CTEs of the adhesives. Additions of the flexibilizers such as siloxanes have also been performed to improve the flexibility of epoxy composite. Amino modified siloxane (AMSs) were used to improve compatibility between epoxy and siloxane. In this study, glass transition temperatures (Tg) and moduli of those composites were measured to confirm the effects of AMS with two different equivalents on thermal/mechanical properties of AMS/epoxy composites. Tg of KF-8010/epoxy composites decreased from 148 to $122^{\circ}C$ and those of X-22-161A/epoxy composites decreased from 148 to $121^{\circ}C$. Moduli of KF-8010/epoxy composites decreased from 2648 to 2143 MPa by adding KF-8010 and moduli of X-22-161A/epoxy composites decreased from 2648 to 2014 MPa. In short, using long Si-O chain AMS leads to a greater decrease in moduli. However, haven't showed significant differences in Tg's.

A Study on the Copyright Protection Liability of Online Service Provider and Filtering Measure (온라인서비스제공자(OSP)의 저작권보호 책임과 필터링)

  • Oh, Yeong-Woo;Jang, Gye-Hyun;Kwon, Hun-Yeong;Lim, Jong-In
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.20 no.6
    • /
    • pp.97-109
    • /
    • 2010
  • Although the primary liability for online copyright infringement may fall on the individual who illegally copies, transfers, and/or distributes the copyrighted content, the issue of indirect liability for Online Service Providers (OSPS) that provide a channel for the distribution of illegal content has recently come under the spotlight. Currently, in an effort to avoid liability for indirect copyright infringement and improve their reputation, most OSPs have voluntarily applied filtering technology. Under the Copyright Act of Korea, special types of OSPS including P2P and Web-based Hard Drive (WebHard) are required to incorporate filtering technology, and may be charged with penalties if found without one. However, despite the clear need for filtering mechanisms, several arguments have been set forth that question the efficacy and appropriateness of the system. As such, this paper discusses the liability theory adopted in the US. -a leader in internet technology development-and analyzes the scope of liability and filtering related regulations in our copyright law. In addition, this paper considers the current applications of filtering as well as limits of the applied filtering technology in OSPS today. Finally, we make four suggestions to improve filtering in Korea, addressing issues such as clarifying the limits and responsibilities of OSPS, searching for cooperative solutions between copyright holders and OSPS, standardizing the filtering technology to enable compatibility among different filtering techniques, and others.

Microwave Dielectric Properties of Ultra-Low Temperature Co-firable Ba3V4O13-BaV2O6 Ceramics (Ba3V4O13-BaV2O6계 초저온 동시소성 세라믹스의 마이크로파 유전 특성)

  • Yoon, Sang-Ok;Hong, Seoyoung;Cho, Hyung-Hwan;Kim, Shin
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.34 no.5
    • /
    • pp.342-347
    • /
    • 2021
  • Phase evolution, sintering behavior, microstructure, and microwave dielectric properties of (1-x) mol Ba3V4O13 - (x) mol BaV2O6 system were investigated. The sintered specimens of all compositions consisted of Ba3V4O13 and BaV2O6, and no secondary phase was observed. As x increased, the linear shrinkage decreased to the composition of x=0.5, and then increased again, implying that Ba3V4O13 and BaV2O6 phases interfered mutually with each other during sintering. All compositions showed a dense microstructure with a large grain growth. Cracks were observed in some compositions because of the relatively high sintering temperature of 620~640℃. As x increased, the dielectric constant increased, while the quality factor was maintained from about 50,000 GHz to about 70,000 GHz up to the composition of x=0.9, and then decreased to 20,987~27,180 GHz at the composition of x=1.0. As x increased, the temperature coefficient of the resonance frequency showed a (+) value from a (-) value. The dielectric constant, the quality factor, and the temperature coefficient of resonant frequency of x=0.7 composition sintered at 640℃ for 4 hours were 10.61, 71,126 GHz, and -4.9 ppm/℃, respectively. This composition showed a good chemical compatibility with Al powder, indicating that the Ba3V4O13-BaV2O6 ceramics are a candidate material for ULTCC (Ultra-Low Temperature Co-fired Ceramics) applications.

The Effect of Communication Distance and Number of Peripheral on Data Error Rate When Transmitting Medical Data Based on Bluetooth Low Energy (저 전력 블루투스 기반으로 의료데이터 전송 시 통신 거리와 연동 장치의 수가 데이터 손실률에 미치는 영향)

  • Park, Young-Sang;Son, ByeongJin;Son, Jaebum;Lee, Hoyul;Jeong, Yoosoo;Song, Chanho;Jung, Euisung
    • Journal of Biomedical Engineering Research
    • /
    • v.42 no.6
    • /
    • pp.259-267
    • /
    • 2021
  • Recently, the market for personal health care and medical devices based on Bluetooth Low Energy(BLE) has grown rapidly. BLE is being used in various medical data communication devices based on low power consumption and universal compatibility. However, since data errors occurring in the transmission of medical data can lead to medical accidents, it is necessary to analyze the causes of errors and study methods to reduce data error. In this paper, the minimum communication speed to be used in medical devices was set to at least 800 byte/sec based on the wireless electrocardiography regulations of the Ministry of Food and Drug Safety. And the data loss rate was tested when data was transmitted at a speed higher than 800 byte/sec. The factors that cause communication data error were classified, and the relationship between each factor and the data error rate was analyzed through experiments. When there were two or more activated peripherals connected to the central, data error occurred due to channel hopping and bottleneck, and the data error rate increased in proportion to the communication distance and the number of activated peripherals. Through this experiment, when the BLE is used in a medical device that intermittently transmits biosignal data, the risk of a medical accident is predicted to be low if the number of peripherals is 3 or less. But, it was determined that BLE would not be suitable for the development of a biosignal measuring device that must be continuously transmitted in real time, such as an electrocardiogram.