• Title/Summary/Keyword: System Capacity

검색결과 8,692건 처리시간 0.036초

태양광 발전 연계 수전해 시스템의 경제성 분석 (Techno-Economic Analysis of Water Electrolysis System Connected with Photovoltaic Power Generation)

  • 황순철;박진남
    • 한국수소및신에너지학회논문집
    • /
    • 제32권6호
    • /
    • pp.477-482
    • /
    • 2021
  • Hydrogen production, hydrogen production cost, and utilization rate were calculated assuming four cases of hydrogen production system in combination of photovoltaic power generation (PV), water electrolysis system (WE), battery energy storage system (BESS), and power grid. In the case of using the PV and WE in direct connection, the smaller the capacity of the WE, the higher the capacity factor rate and the lower the hydrogen production cost. When PV and WE are directly connected, hydrogen production occurs intermittently according to time zones and seasons. In addition to the connection of PV and WE, if BESS and power grid connection are added, the capacity factor of WE can be 100%, and stable hydrogen production is possible. If BESS is additionally installed, hydrogen production cost increases due to increase in Capital Expenditures, and Operating Expenditure also increases slightly due to charging and discharging loss. Even in a hydrogen production system that connects PV and WE, linking with power grid is advantageous in terms of stable hydrogen production and improvement of capacity factor.

Determination of Buffering Capacity of Hygoscopic Fabrics Under Subzero Conditions by Using Man-Clothing-Environment Simulator

  • Kim, Eun-Ae;Shinjung Yoo;Kim, Jeongjin;Junghee Yeo
    • 한국섬유공학회:학술대회논문집
    • /
    • 한국섬유공학회 2003년도 The Korea-Japan Joint Symposium
    • /
    • pp.51-52
    • /
    • 2003
  • In order to understand the buffering behavior of hygroscopic fabric under subzero conditions, microclimates of the wool and PET clothing system were measured and compared. Vertical type Man-Clothing-Environment simulator was used to measure the microclimate at the environmental temperature of -10$^{\circ}C$. Buffering capacity was quantified by calculating from the depth and width of the hyperbolic curve of the graph. Hydrophilic wool fabrics showed better buffering capacity at the transient state than hydrophobic PET fabrics; which is attributed to the heat of sorption.

  • PDF

CDMA2000 1x 시스템을 위한 송신전력기반 전송률 제어방안 (Transmitted Power Based Dynamic Rate Control for CDMA2000 1x System)

  • 박형근
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제54권8호
    • /
    • pp.498-500
    • /
    • 2005
  • In a CDMA system, the capacity is variable and mainly depends on multiple access interference. The multiple access interference has a deep relationship with transmitted or received power The capacity of CDMA2000 1x system is considered to be limited by the forward link capacity Different rate data traffic requires different transmitted power and rate controlling enables the system utilize radio resource more efficiently. A very simple rate control algorithm for data calls in CDMA2000 1x system is proposed. In the proposed algorithm, by monitoring the total transmit power, we can simply adjust data rate to channel conditions and efficiently use radio resources. The proposed algorithm is easy to implement in power controlled CDMA systems.

저항접지 시스템에서 지락사고시 CLR과열 소손방지를 위한 GPT 정격용량의 적정성 연구 (Analysis on the Protective Coordination with Hybrid Superconducting Fault Current Limiter)

  • 신호전;김진석;박유환;김재철;조만영
    • 전기학회논문지
    • /
    • 제61권4호
    • /
    • pp.503-508
    • /
    • 2012
  • Among the high distribution voltage consumers, high-capacity consumers are often applying the grounding resistance method in order to overcome demerits such as erroneous operation of the ground reply or potential increase in the battery at the accident of the isolated neutral system. In this paper, to prevent damage to CLR and GPT in the delay to block the breakdown in the resistance grounded neutral system, this study aims to provide a proper suggestion for continuous rating capacity of GPT to check the appropriateness of CLR size and reduce GPT burden. Thereupon, this study comparatively analyzes CLR current applied in general GPT and the current gained when CLR demanded in the system is used and analyzes the simulated system through simulation using PSCAD/EMTDC in order to suggest GPT's proper continuous rating capacity.

CDMA2000 1x 시스템을 위한 송신전력기반 전송률 제어방안 (Transmitted power based dynamic rate control for CDMA2000 1x system)

  • 박형근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 심포지엄 논문집 정보 및 제어부문
    • /
    • pp.221-223
    • /
    • 2005
  • In a CDMA system, the capacity is variable and mainly depends on multiple access interference. The multiple access interference has a deep relationship with transmitted or received power. The capacity of CDMA2000 1x system is considered to be limited by the forward link capacity. Different rate data traffic requires different transmitted power and rate controlling enables the system utilize radio resource more efficiently. A very simple rate control algorithm fer data calls in CDMA2000 1x system is proposed. In the proposed algorithm, by monitoring the total transmit power, we can simply adjust data rate to channel conditions and efficiently use radio resources. The proposed algorithm is easy to implement in power controlled CDMA systems.

  • PDF

Implementation of Hardware RAID and LVM-based Large Volume Storage on Global Data Center System of International GNSS Service

  • Lee, Dae-Kyu;Cho, Sung-Ki;Park, Jong-Uk;Park, Pil-Ho
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.1553-1557
    • /
    • 2005
  • High performance and reliability of the storage system to handle a very large amount of data has been become very important. Many techniques have been applied on the various application systems to establish very large capacity storage that satisfy the requirement of high I/O speed and physical or logical failure protection. We applied RAID and LVM to construct a storage system for the global data center which needs a very reliable large capacity storage system. The storage system is successfully established and equipped on the latest Linux application server.

  • PDF

제습냉방시스템에서 요소성능이 시스템성능에 미치는 영향 (Effects of Individual Components on the System Performance in a Desiccant Cooling System)

  • 장영수;이대영
    • 설비공학논문집
    • /
    • 제19권10호
    • /
    • pp.687-694
    • /
    • 2007
  • Cycle simulation is peformed for two types of the desiccant cooling system incorporating a regenerative evaporative cooler. The cooling capacity and COP are evaluated at various effectiveness values of the regenerative evaporative cooler, the desiccant rotor and the sensible heat exchanger. As either of the effectiveness of the regenerative evaporative cooler or the humidity effectiveness of the desiccant rotor increases, both the cooling capacity and COP increase, but the enthalpy leak ratio gives the opposite effect on the system performance. It is found that COP of cycle A mainly depends on the humidity effectiveness of the desiccant rotor, while for cycle B enthalpy leak ratio of desiccant rotor has the major impact on COP. The effect of the sensible heat exchanger on the cooling capacity is small about 1/10 compared with those of other components.

다수의 나카가미(nakagami) 페이딩을 받은 AMPS 간섭파가 불완전 전력제어된 DS/CDMA 시스템의 용량에 미치는 영향 (The effectof the multiple nakagami faded AMPS interferers on the capacity of the imperfect power controlled DS/CDMA system)

  • 김남수
    • 한국통신학회논문지
    • /
    • 제21권12호
    • /
    • pp.3196-3204
    • /
    • 1996
  • We analyze the capacity of the imperfect power controlled DS/CDMA system with the Nakagami faded AMPS interferers by means of the analytical approach. Unlike the theoretical aassumption, the power control of the DS/CDMA system is not perfect. Therefore in this analysis we consider various parameters which cause the capacityreduction of the DS/CDMA system, the imperfect power control, the Nakagami fading index, he processing gain, and the number of AMPS interferers. The analytical results are compared with the Prasad's results which are considered only the imperfect power control of the DS/CDMA system. It is shown that the DS/CDMA capacity is decreased according to the increase of the deviation of the imperfect power control, to icrease the number pf the analog interfering users, and to decrease the processing gain.

  • PDF

Analysis on the Impact of Multiple-Antenna Transmit Schemes on Multiuser Diversity

  • Lee, Myoung-Won;Mun, Cheol;Yook, Jong-Gwan
    • Journal of electromagnetic engineering and science
    • /
    • 제6권4호
    • /
    • pp.222-228
    • /
    • 2006
  • In this paper, the performance of a multiuser diversity system combined with a multi-element transmit antenna system is analyzed under the assumption of independent Rayleigh fading. A measure of system .level performance is an average channel capacity as a function of the number of users and antennas. Average channel capacity is obtained from the instantaneous signal-to-noise ratio(SNR) distribution combined by both transmit diversity(TD) at each link and multiuser diversity at system level. Numerical results show that closed-loop antenna techniques provide an additional gain with multiuser diversity system due to array gain, even though space diversity gain reduces multiuser diversity gain. On the other hand, the space-time block coding(STBC) that provides full order space diversity gain only has a destructive influence on multiuser diversity.

고온초전도 케이블의 대도시 계통적용을 위한 모델링 및 송전용량과 전압계급의 검토 (A Study on System Modeling, Capacity and Voltage rating to supply HTS Power Transmission Cable to Metropolitan Area)

  • 최상봉;정성환;김대경;김학만;문영환;성기철
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제4권1호
    • /
    • pp.61-65
    • /
    • 2002
  • It becomes difficult and high in cost to construct new ducts and/or tunnels for power cables in metropolitan areas. This paper presents possible applications of an HTS superconducting power cables for transmitting electric power in metropolitan areas. Reflected were its important distinction such as compactness for installation in underground ducts and considerably high efficiency compared with present underground cables. In this paper, system modeling, transmission capacity and voltage class of compact HTS cables which should be applied to existing ducts were reviewed. Based on this, the following items on urban transmission system are examined. (1) A method of constructing a model system to introduce high temperature superconducting cables to metropolitan areas is presented. (2)The maximum outer diameter of HTS cables to be accommodated in exiting ducts is calculated based on the design standards for current cable ducts. (3)The voltage level that can be accommodated by existing ducts is examined.