Effects of Individual Components on the System Performance in a Desiccant Cooling System  

Chang, Young-Soo (Energy Mechanics Research Center, Korea institute of Science and Technology)
Lee, Dae-Young (Energy Mechanics Research Center, Korea institute of Science and Technology)
Publication Information
Korean Journal of Air-Conditioning and Refrigeration Engineering / v.19, no.10, 2007 , pp. 687-694 More about this Journal
Abstract
Cycle simulation is peformed for two types of the desiccant cooling system incorporating a regenerative evaporative cooler. The cooling capacity and COP are evaluated at various effectiveness values of the regenerative evaporative cooler, the desiccant rotor and the sensible heat exchanger. As either of the effectiveness of the regenerative evaporative cooler or the humidity effectiveness of the desiccant rotor increases, both the cooling capacity and COP increase, but the enthalpy leak ratio gives the opposite effect on the system performance. It is found that COP of cycle A mainly depends on the humidity effectiveness of the desiccant rotor, while for cycle B enthalpy leak ratio of desiccant rotor has the major impact on COP. The effect of the sensible heat exchanger on the cooling capacity is small about 1/10 compared with those of other components.
Keywords
Desiccant cooling system; Regenerative evaporative cooler; Desiccant rotor; Component performance;
Citations & Related Records
Times Cited By KSCI : 3  (Citation Analysis)
연도 인용수 순위
1 Lee, J. W., Lee, D. Y. and Kang, B. H., 2004, Cycle simulation of a desiccant cooling system with a regenerative evapor-ative cooler, Korean J. Air-Conditioning and Refrigeration Engineering, Vol. 16, pp. 566-573   과학기술학회마을
2 Song, G. E. and Lee, D. Y., 2006, Development of a compact regenerative evaporative cooler, Proc. 13th IHTC, HEX - 30
3 Kodama, A., Hirayama, T., Goto, M., Hirose, T. and Critoph, R. E., 2001, The use of psychrometric charts for the optimisation of a thermal swing desiccant wheel, Applied Thermal Engineering, pp.1657-1674
4 Maclaine-Cross, I, L. and Banks, P. J., 1983, A general theory of wet surface heat exchangers and its application to regenerative evaporative cooler, Journal of Heat Transfer, Vol. 103, pp. 579-585   DOI
5 Lee, G., Kim, M. S. and Lee, D. Y., 2005, Derivation and analysis of dimensionless parameters dominating the dehumidification characteristics of a desiccant Rotor, Korean J. Air-Conditioning and Refrigeration Engineering. Vol. 17, pp.611-619   과학기술학회마을
6 Lee, D. Y., Yoon, Y. I. and Lee, J. H., 2002, Optimal design and performance evaluation of a finned regenerative evaporative cooler, Proc. 12th IHTC, pp.261-266
7 Lee, D. Y., Lee, G. and Kim, M. S., 2007, A proposal for new definition of performance indices of a desiccant rotor, Korean J. Air-Conditioning and Refrigeration Engineering, Vol. 19, pp.537-544   과학기술학회마을
8 Daou, K., Wang, R. Z. and Xia, Z. Z., 2006, Desiccant cooling air conditioning: a review, Renewable and Sustainable Energy Reviews, Vol. 10, pp.55-77   DOI   ScienceOn