• 제목/요약/키워드: Synthetic CT

검색결과 38건 처리시간 0.024초

Comparative study of new bone formation capability of zirconia bone graft material in rabbit calvarial

  • Kim, Ik-Jung;Shin, Soo-Yeon
    • The Journal of Advanced Prosthodontics
    • /
    • 제10권3호
    • /
    • pp.167-176
    • /
    • 2018
  • PURPOSE. The purpose of this study was to compare the new bone formation capability of zirconia with those of other synthetic bone grafts. MATERIALS AND METHODS. Twelve rabbits were used and four 6-mm diameter transcortical defects were formed on each calvaria. Each defect was filled with Osteon II (Os), Tigran PTG (Ti), and zirconia (Zi) bone grafts. For the control group, the defects were left unfilled. The rabbits were sacrificed at 2, 4, and 8 weeks. Specimens were analyzed through micro computed tomography (CT) and histomorphometric analysis. RESULTS. The Ti and Zi groups showed significant differences in the amount of newly formed bone between 2 and 4 weeks and between 2 and 8 weeks (P<.05). The measurements of total bone using micro CT showed significant differences between the Os and Ti groups and between the Os and Zi groups at 2 and 8 weeks (P<.05). Comparing by week in each group, the Ti group showed a significant difference between 4 and 8 weeks. Histomorphometric analysis also showed significant differences in new bone formation between the control group and the experimental groups at 2, 4, and 8 weeks (P<.05). In the comparison of newly formed bone, significant differences were observed between 2 and 4 weeks and between 2 and 8 weeks (P<.05) in all groups. CONCLUSION. Zirconia bone graft material showed satisfactory results in new bone formation and zirconia could be used as a new synthetic bone graft material.

MIM 소프트웨어를 이용한 3-D PET/CT 영상의 방사선치료 평가를 위한 임상적용에 관한 연구 (Using MIM Software 3-D PET / CT imaging for the evaluation of radiation therapy on the clinical application of research)

  • 이상호
    • 한국방사선학회논문지
    • /
    • 제9권4호
    • /
    • pp.249-255
    • /
    • 2015
  • 본 연구는 PET/CT의 이미지 추가 정보를 통해 이미지 재형성과 합성기능을 바탕으로 TPS 임상 적용과 기초 자료 활용 및 지속적인 연구 개발을 위하여 True-D 기법과 MIM 소프트웨어를 접목하여 각각의 영상 간 합성 작업을 기반으로 이미지의 폭 넓은 활용으로 임상에서 판독에 소용되는 시간 및 비용을 줄이고 효율적 진단 및 방사선치료 시 종양 표적 결정에 유효한 도구로 사용하고자 함이며 정밀한 치료효과 판정에 활용하여 임상에서 판독에 소요되는 시간과 불필요한 추가 검사를 줄일 수 있을 것으로 기대하며 종양환자 판독 보고서 작성 및 PACS 등 타 소프트웨어와의 호환성 개발로 PET/CT 기기의 성능평가에 활용 될 것으로 기대한다.

코팅된 무색 합성 모이사나이트의 특징 (Characterization of coated colorless synthetic moissanite)

  • 최현민;김영출;장한수;석정원
    • 한국결정성장학회지
    • /
    • 제32권1호
    • /
    • pp.7-11
    • /
    • 2022
  • 한미보석감정원은 최근에 5개의 투명한 합성 모이사나이트를 검사했다. 그 샘플들은 라운드 브릴리언트 컷의 무색, 핑크, 황색, 청색, 적색 컬러와 0.93~0.96 ct 중량을 가지고 있었다. FT-IR과 Raman 분석 결과 합성 모이사나이트임을 확인하였고, 확대검사 결과 무색을 제외한 나머지 샘플에서 코팅의 흔적이 발견되었다. EDXRF 분석 결과 무색 샘플을 제외한 모든 샘플의 코팅부분에서 Ca, Ti, Co의 미량원소가 검출되었다. 무색 샘플의 Raman 분석에서 탄소 원자의 sp3 bonding에 의해 생성되는 1332 cm-1 또는 graphite와 관련된 sp2 bonding에 의해 생성되는 ~1550 cm-1는 발견되지 않았다. 무색 샘플의 SEM 이미지에서도 코팅의 흔적은 발견되지 않았으나, TEM 이미지에서 3~8 nm의 코팅층의 존재가 발견됐다. EDX line 프로파일과 EDX elements map을 통해 무색 샘플의 코팅층을 구성하는 원소는 C, Si, O로 추정된다.

Fast and Accurate Rigid Registration of 3D CT Images by Combining Feature and Intensity

  • June, Naw Chit Too;Cui, Xuenan;Li, Shengzhe;Kim, Hak-Il;Kwack, Kyu-Sung
    • Journal of Computing Science and Engineering
    • /
    • 제6권1호
    • /
    • pp.1-11
    • /
    • 2012
  • Computed tomography (CT) images are widely used for the analysis of the temporal evaluation or monitoring of the progression of a disease. The follow-up examinations of CT scan images of the same patient require a 3D registration technique. In this paper, an automatic and robust registration is proposed for the rigid registration of 3D CT images. The proposed method involves two steps. Firstly, the two CT volumes are aligned based on their principal axes, and then, the alignment from the previous step is refined by the optimization of the similarity score of the image's voxel. Normalized cross correlation (NCC) is used as a similarity metric and a downhill simplex method is employed to find out the optimal score. The performance of the algorithm is evaluated on phantom images and knee synthetic CT images. By the extraction of the initial transformation parameters with principal axis of the binary volumes, the searching space to find out the parameters is reduced in the optimization step. Thus, the overall registration time is algorithmically decreased without the deterioration of the accuracy. The preliminary experimental results of the study demonstrate that the proposed method can be applied to rigid registration problems of real patient images.

인공결석모형물의 부피와 하운스필드값 측정에 대한 전산화단층촬영기기의 타입과 빔 콜리메이션의 영향 (Effect of Different CT Scanner Types and Beam Collimations on Measurements of Three-Dimensional Volume and Hounsfield Units of Artificial Calculus Phantom)

  • 왕지환;이희천
    • 한국임상수의학회지
    • /
    • 제31권6호
    • /
    • pp.495-501
    • /
    • 2014
  • 본 연구는 다양한 전산화단층촬영기기와 촬영 프로토콜의 차이에 따른 모형물의 부피와 Hounsfield unit (HU) 수치의 차이를 평가하고 이 후 전산화단층촬영술을 이용하여 결석의 부피와 HU 수치를 포함한 다양한 인자들을 평가하고 이 중 체외충격파쇄석술에 의한 결석의 분쇄를 예측할 수 있는 인자를 찾고자 하였다. 다양한 직경의 100 HU 인공종양 5개를 (직경 3.0-12.0 mm) 이용하여 모형물을 만들었으며, 이 모형물의 부피와 HU 수치를 Siemens사의 2채널, GE사의 4채널과 64채널, 그리고 Philips사의 64채널 전산화단층촬영기기를 사용하여 평가하였다. 또한 각각의 전산화단층촬영기기에서 동일한 조건으로 collimation만 thin collimation과 thick collimation으로 변화를 주어 모형물을 촬영한 후 모형물의 부피와 HU 수치를 평가하였다. 평가자간 (inter-observer) 재현성을 평가하기 위해 3명의 수의영상의학 전공의가 연구에 참여하였으며 이중 한 명의 수의사가 평가자내 (intra-observer) 재현성을 평가하기 위해 모형물의 부피와 HU 수치를 2주 간격으로 총 3번 측정하였다. 부피의 평가자간 재현성과 평가자내 재현성은 k=0.9994, k=0.9969로 아주 우수하였으며, HU 수치의 평가자간 재현성과 평가자내 재현성 역시 k=0.9984, k=0.9655로 아주 우수하였다. 다양한 전산화단층촬영기기와 collimation 차이에 따른 부피와 HU 수치의 차이는 모두 통계학적으로 유의적인 차이를 나타내지 않았다. 그러나 부피의 경우 collimation이 얇을수록 부피의 정확도가 증가하는 경향을 보였다. 본 연구 결과를 토대로 향후 진행될 결석의 부피 및 HU 수치의 평가 시 전산화단층촬영기기의 차이에 따른 영향을 받지 않으리라 판단되어 Siemens사의 2채널 전산화단층촬영기기만을 사용하였으며, 비록 통계학적으로 유의적인 차이는 없었지만 부피의 정확도를 더 높이기 위하여 얇은 collimation을 사용하였다.

A Study on Synthetic Failure-finding Method for Electrical and Thermal Degradation of Polymer Insulator by Surface Discharge

  • Lee, Kang-Won;Jang, Dong-Uk;Park, Cheol-Hyun
    • Transactions on Electrical and Electronic Materials
    • /
    • 제8권3호
    • /
    • pp.143-146
    • /
    • 2007
  • Polymer insulators are used widely in variable fields for high voltage insulation and separating people from high voltage charging parts for safety and also supporting overhead power line in electric railway. But it may be broken down by tracking path resulting from continuous surface discharge. This paper has investigated synthetically both the characteristics of electrical aging using precision CT(current transformer) and the thermal aging using thermography method. Electrical aging was analyzed for time-frequency region and thermal aging was illustrated by image processing method. This synthetic method may be an appropriate one to evaluate the surface degradation of polymer insulator.

이미지 분석을 활용한 합성수지 혼입 모르타르의 특성 및 미세구조 분석 (Microstructure and Properties of Mortar Containing Synthetic Resin using Image Analysis)

  • 이빛나;민지영;이종석;이장화
    • 콘크리트학회논문집
    • /
    • 제28권1호
    • /
    • pp.59-65
    • /
    • 2016
  • 본 연구에서는 수소 함유량이 높아 중성자 차폐에 유리한 합성수지를 대상으로 중성자 차폐용 골재로서의 적용성 검토를 수행하였다. 사용된 합성수지는 고밀도 폴리에틸렌(HDPE), 폴리프로필렌(PP), 초고분자량 폴리에틸렌(UPE)으로 잔골재의 20%, 40%, 60%의 부피에 해당하는 양을 무게로 환산하여 배합하였다. 실험은 모르타르의 물리적 특성을 파악할 수 있는 플로우 테스트, 인장 및 압축강도 시험을 수행하였으며, 시험체 내부의 미세구조를 분석하기 위해 파단면의 이미지 분석, SEM 및 X-ray CT 촬영을 실시하였다. 합성수지를 혼입한 모르타르의 플로우의 값은 HDPE 및 PP는 증가하였지만 UPE의 경우 감소하였다. 반면 인장 및 압축강도의 경우 종류에 상관없이 전반적으로 강도가 감소하는 경향을 보였으며, 이미지 분석 결과, HDPE 및 PP를 혼입한 모르타르의 강도는 혼입량에 관계없이 파단면에서의 합성수지 비율에 영향을 받았으며, 모르타르 내의 시멘트 매트릭스와의 단락 및 재료의 불균등한 분포가 강도 저하에 영향을 미친 것으로 추정된다. 반면, 미분말 상태인 UPE는 혼입량이 증가함에 따라 내부 공극이 증가하였으며, 이러한 특징은 일정량 이하에서는 강도 저하가 미미하였으나 일정한 혼입률 이상, 특히 본 실험에서는 치환율이 60% 이상에서 급격한 강도 저하를 나타냈다.

기하학적 동적 외곽선 모델을 이용한 X-ray 단층촬영영상의 영상추출 (Segmentation of Computed Tomography using The Geometric Active Contour Model)

  • 장동표;김선일
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1997년도 추계학술대회
    • /
    • pp.541-545
    • /
    • 1997
  • This paper presents a modified geometric active contour model or edge detection and segmentation of computed tomography(CT) scan images. The method is based on the level setup approach developed by Osher and Sethian and the modeling of propagation fronts with curvature dependent speeds by Malladi. Based on above algorithms, the geometric active contour is obtained through a particular level set of hypersurface lowing along its gradient force and curvature force. This technique retains the attractive feature which is topological and geometric flexibility of the contour in recovering objects with complex shapes and unknown topologies. But there are limitations in this algorithm which are being not able to separate the object with weak difference from neighbor object. So we use speed limitation filter to overcome those problems. We apply a 2D model to various synthetic cases and the three cases of real CT scan images in order to segment objects with complicated shapes and topologies. From the results, the presented model confirms that it attracts very naturally and efficiently to the desired feature of CT scan images.

  • PDF

먹장어 Cathepsin L의 분자생물학적 클로닝, 발현 및 효소학적 특성 분석 (Cloning, Expression Analysis and Enzymatic Characterization of Cathepsin L from the Inshore Hagfish (Eptatretus burgeri))

  • 장진현;손소희;조현경;정준기;이형호
    • 수산해양교육연구
    • /
    • 제28권4호
    • /
    • pp.903-912
    • /
    • 2016
  • Hagfish which belongs to the chordate contact cyclostomata, is important phylogenetic relationship between vertebrate and invertebrate. Cathepsins of the cysteine protease family have traditionally been thought to play a major role in intracellular protein degradation and turnover in lysosomes. In this study, Catepsin L was cloned from Inshore hagfish (Eptatretus burgeri), the cDNA encoding ORF of the Eptatretus burgeri Cathepsin L (EbCtL) is 978 bp. The cDNA encoding proEbCtL was expressed in Escherichia coli strain BL21(DE3) using the pGEX-4T-1 expression vector system. The recombinant proEbCtL protein was overexpressed as a approximately 55 kDa fusion protein. The overproduced soluble GST-fusion protein was then applied to glutathione-Sepharose 4B column chromatography; the sample harboring the fusion protein evidenced a high degree of purity when analyzed via SDS-PAGE and Western blot analysis. Its activity was quantied by cleaving the synthetic peptide Z-FR-AMC, Z-LLE-AMC, and Suc-AAF-AMC, and the optimal pH for the protease activity was 8, 9.5, and 9, respectively.

Saccharomyces cerevisiae에서 GAL 10 promoter와 exoinulinase 분비 서열을 이용한 Clostridium endoglucanase A의 과발현·분비 (Secretory Overexpression of Clostridium Endoglucanase A in Saccharomyces cerevisiae Using GAL10 Promoter and Exoinulinase Signal Sequeice.)

  • 임명예;이진우;이재형;김연희;서진호;남수완
    • 생명과학회지
    • /
    • 제17권9호통권89호
    • /
    • pp.1248-1254
    • /
    • 2007
  • Kluyveromyces marxianus 유래의 exoinulinase (INU1) 분비 서열과 GAL10 promoter를 이용하여 Clostridium thermocellum endoglucanase A gene (celA)의 과발현과 분비 성능 검증연구를 수행하였다. 자체 분비 서열을 가지는 pYEG- CT1 과 INU1 분비 서열을 가지는 pYInu-CT1, 두개의 plasmid는 S. cer-evisiae SEY2102와 S. cerevisiae 2805에 각각 형질전환시켜 ur-acil이 결핍된 배지에서 선별하였다. celA gene 자체 분비 서열보다 INU1 분비 서열을 사용했을 때 발현량과 분비효율은 각각 약 $18{\sim}22%$ 와 11% 향상되었다. 이 중 361 unit/l의 발현율과 89%의 plasmid 안정성, 그리고 70%의 분비효율을 보인 S. cerevisiae 2805/pYinu-CT1 효모 형질전환체를 cellolose를 효과적으로 분해하는 재조합 효모 생균체로 선별하였다. Galactose 배지내에서 S. cerevisiae 2805/ pYInu-CT1의 발효조 회분배양 결과, 총발현량과 분비효율은 각각 418 unit/l 와 73% 로 나타났다. 또한 분비된 endoglucanase A는 분자량 100kDa 이상에서 활성 밴드를 보여, N-linked 당쇄부가에 의해 상당한 비율의 당쇄가 부가됨을 추측할 수 있었다.