• 제목/요약/키워드: Symmetrical components

검색결과 78건 처리시간 0.028초

GUI를 이용한 교육용 디지털 거리계전기 시뮬레이터 개발에 관한 연구 (A Study on the Development of the Digital Distance Relay Simulator for Education using GUI)

  • 김동수;김철환;이기택;박남옥
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제54권8호
    • /
    • pp.388-395
    • /
    • 2005
  • It has always been of great importance in the electrical power system to educate an algorithm on the digital relaying, but it is difficult to educate an algorithm of a digital distance relay on power system because of exclusiveness of the relaying algorithm on power system. Therefore, we need a digital distance relay simulator, which can simulate the algorithm of the digital relaying on transmission line. In this Paper, we extract fundamental components using digital signal processing from data which are a variety of the simulated faults by EMTP. Then this simulator represents instantaneous values, ms values and symmetrical components that are calculated by fundamental components of voltages and currents. The Simulator also represents the zones of a digital distance relay and the locus of an impedance using GUI. Consequently, the developed simulator is particularly useful for understanding of the fundamental concepts of a distance relaying algorithm from a power system engineer points of view.

Design and Evaluation of a Protection Relay for a Wind Generator Based on the Positive- and Negative-Sequence Fault Components

  • Zheng, Taiying;Cha, Seung-Tae;Kim, Yeon-Hee;Crossley, Peter A.;Lee, Sang Ho;Kang, Yong Cheol
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권5호
    • /
    • pp.1029-1039
    • /
    • 2013
  • To avoid undesirable disconnection of healthy wind generators (WGs) or a wind power plant, a WG protection relay should discriminate among faults, so that it can operate instantaneously for WG, connected feeder or connection bus faults, it can operate after a delay for inter-tie or grid faults, and it can avoid operating for parallel WG or adjacent feeder faults. A WG protection relay based on the positive- and negative-sequence fault components is proposed in the paper. At stage 1, the proposed relay uses the magnitude of the positive-sequence component in the fault current to distinguish faults requiring non-operation response from those requiring instantaneous or delayed operation responses. At stage 2, the fault type is first determined using the relationships between the positive- and negative-sequence fault components. Then, the relay differentiates between instantaneous operation and delayed operation based on the magnitude of the positive-sequence fault component. Various fault scenarios involving changes in position and type of fault and faulted phases are used to verify the performance of the relay. This paper concludes by implementing the relay on a hardware platform based on a digital signal processor. Results indicate that the relay can successfully distinguish the need for instantaneous, delayed, or non-operation.

J2 와 J3 불변량에 기초한 비대칭 항복함수의 제안(II) (Asymmetric Yield Functions Based on the Stress Invariants J2 and J3(II))

  • 김영석;눙엔푸반;안정배;김진재
    • 소성∙가공
    • /
    • 제31권6호
    • /
    • pp.351-364
    • /
    • 2022
  • The yield criterion, or called yield function, plays an important role in the study of plastic working of a sheet because it governs the plastic deformation properties of the sheet during plastic forming process. In this paper, we propose a modified version of previous anisotropic yield function (Trans. Mater. Process., 31(4) 2022, pp. 214-228) based on J2 and J3 stress invariants. The proposed anisotropic yield model has the 6th-order of stress components. The modified version of the anisotropic yield function in this study is as follows. f(J20,J30) ≡ (J20)3 + α(J30)2 + β(J20)3/2 × (J30) = k6 The proposed anisotropic yield function well explains the anisotropic plastic behavior of various sheets such as aluminum, high strength steel, magnesium alloy sheets etc. by introducing the parameters α and β, and also exhibits both symmetrical and asymmetrical yield surfaces. The parameters included in the proposed model are determined through an optimization algorithm from uniaxial and biaxial experimental data under proportional loading path. In this study, the validity of the proposed anisotropic yield function was verified by comparing the yield surface shape, normalized uniaxial yield stress value, and Lankford's anisotropic coefficient R-value derived with the experimental results. Application for the proposed anisotropic yield function to AA6016-T4 aluminum and DP980 sheets shows symmetrical yielding behavior and to AZ31B magnesium shows asymmetric yielding behavior, it was shown that the yield locus and yielding behavior of various types of sheet materials can be predicted reasonably by using the proposed anisotropic yield function.

유한요소 해석을 통한 AA 5052 판재의 Cross-roll 압연시 Cross angle에 따른 변형을 상태의 변화 (Evolution of strain states during Cross-roll rolling in AA 5052 sheet for varying cross-roll angle using FEM)

  • 김상현;강형구;김대근;이재설;허무영
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2008년도 추계학술대회 논문집
    • /
    • pp.95-98
    • /
    • 2008
  • In the present work, cross-roil rolling was rallied out using a rolling mill in which the roll axes are tilted by $5^{\circ},\;7.5^{\circ},\;10^{\circ}$ towards the transverse direction of the roiled sample. The evolution of strain states during cross-roll rolling was investigated by three-dimensional finite element method (FEM) simulation. Parallel to cross-roll rolling, normal-rolling using a conventional rolling mill was also carried out in the same rolling condition for clarifying the effect of cross-roll rolling. It turned out that three shear rate components were all introduced to the rolled sample by the cross-roll rolling process, while only one shear rate component operated during normal-rolling.

  • PDF

A Novel Detection Algorithm for Instantaneous Voltage Sag Corrector Using Series Compensator

  • Lee, Sang-Hoon;Choi, Jae-Ho
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.502-507
    • /
    • 2001
  • This paper proposes a novel detection algorithm of faulted voltages under the unbalanced condition. To quantify the standard of unbalance under the faulted conditions, the 3-phase unbalanced voltages are decomposed into two balanced 3-phase symmetrical components of the positive and negative sequence voltages, which is defined by the magnitude factor (MF) and unbalance factor (MF). It is analyzed that MF and UF values are given as the dc constant values even though unbalance condition. This paper also proposes the control scheme of the instantaneous voltage sag corrector based on this detection algorithm. The validity of the proposed algorithm is verified through the EMTDC simulation and experiments.

  • PDF

Input Current Characteristics of a Three-Phase Diode Rectifier with Capacitive Filter Under Line Voltage Unbalance Condition

  • Jeong Seung-Gi;Lee Dong-Ki;Park Ki-Won
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.808-815
    • /
    • 2001
  • The three-phase diode rectifier with a capacitive filter is highly sensitive to line voltage unbalance, and may cause significantly unbalanced line currents even under slightly unbalanced voltage condition. This paper presents an analysis of this 'unbalance amplification' effect for an ideal rectifier circuit without ac-and dc-side inductors. The voltage unbalance is modeled by introducing a deviation voltage superimposed on balanced three-phase line voltages. With proper approximations, closed-form expressions for symmetrical components of the line current and current unbalance factor are derived in terms of the voltage unbalance factor, filter reactance, and load current. The validity of analytical predictions is confirmed by simulation.

  • PDF

태양광전원의 연계에 의한 배전계통 보호기기의 최적 운용방안에 관한 연구 (Optimal Operation Methods of Protection Devices in Distribution Systems with PV Systems)

  • 김병기;박재범;유경상;노대석
    • 전기학회논문지
    • /
    • 제60권8호
    • /
    • pp.1485-1491
    • /
    • 2011
  • This paper deals with the technical problems for the protection devices, by simulating test facilities of protection coordination for Photovoltaic systems. In order to analyze the operation characteristics for the protection devices in the case that the Photovoltaic systems with bi-directional power supply are located in the feeder, this paper proposes the test facilities composed of model distribution system, protection device and model Photovoltaic systems. By performing the simulation for operation characteristics for the protection devices based on the test facilities, this paper presents the malfunction mechanism for the protection devices. The test results show that this paper is practical and effective for the technical guideline for the Photovoltaic systems.

A Level Dependent Source Concoction Multilevel Inverter Topology with a Reduced Number of Power Switches

  • Edwin Jose, S.;Titus, S.
    • Journal of Power Electronics
    • /
    • 제16권4호
    • /
    • pp.1316-1323
    • /
    • 2016
  • Multilevel inverters (MLIs) have been preferred over conventional two-level inverters due to their inherent properties such as reduced harmonic distortion, lower electromagnetic interference, minimal common mode voltage, ability to synthesize medium/high voltage from low voltage sources, etc. On the other hand, they suffer from an increased number of switching devices, complex gate pulse generation, etc. This paper develops an ingenious symmetrical MLI topology, which consumes lesser component count. The proposed level dependent sources concoction multilevel inverter (LDSCMLI) is basically a multilevel dc link MLI (MLDCMLI), which first synthesizes a stepped dc link voltage using a sources concoction module and then realizes the ac waveform through a conventional H-bridge. Seven level and eleven level versions of the proposed topology are simulated in MATLAB r2010b and prototypes are constructed to validate the performance. The proposed topology requires lesser components compared to recent component reduced MLI topologies and the classical topologies. In addition, it requires fewer carrier signals and gate driver circuits.

배전선로 고장점 표정 알고리즘 (A fault location algorithm for distribution feeder systems)

  • 이덕수;진보건;이승재;강상희;최면송;안복신;윤남선
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 춘계학술대회 논문집 전력기술부문
    • /
    • pp.251-253
    • /
    • 2001
  • This paper presents a fault location algorithm for distribution feeder systems. Distribution feeders include single phase and three phase laterals. The proposed algorithm achieves a high accuracy by continuously updating voltage and current phasor using the symmetrical components and admittance load model.

  • PDF

Cell cycle regulatory element in the promoter of the human thymidine kinase gene and its binding to factors

  • Kim, Yong-Kyu
    • 한국응용약물학회:학술대회논문집
    • /
    • 한국응용약물학회 1995년도 제3회 추계심포지움
    • /
    • pp.9-15
    • /
    • 1995
  • When quiescent cells ate stimulated to enter the cell cycle, the thymidine kinase(TK) gene is transcriptionally activated at the border of Gl and 5. In this report we show that the human TK promoter contains multiple protein-binding sites. By site-directed mutagenesis, we identified a protein-binding site on the human TK promoter requited for conferring Gl-S-regulated transcription to a heterologous promoter and dissociated it functionally from an adjacent protein-binding domain containing an inverted CCAAT motif requited for high basal level expression. Substitution-mutation of this site results in constitutive expression of the neo reporter gene in serum-stimulated fibroblasts, as well as in cells arrested in mid-Gl by a temperature-sensitive mutation. The regulatory domains for the human TK promoter exhibit interesting symmetrical features, including a set of CCAAT motifs and sites similar to the novel Yi protein-binding site recently discovered in the mouse TK promoter. Thus, components of the hTK complex is important for hTK gene regulation.

  • PDF