• Title/Summary/Keyword: Switching control algorithms

Search Result 102, Processing Time 0.024 seconds

Development of Control Algorithms Considering the Effect of a Control Sampling Period on the Total Amount of Switching for a Switched System (컨트롤 샘플링 주기가 스위칭 시스템의 결합-분리 횟수에 미치는 영향을 고려한 제어 알고리듬 개발)

  • Joung, Jin-Wook;Chung, Lan
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.13 no.4
    • /
    • pp.67-76
    • /
    • 2009
  • Recently, the active interaction control (AIC) system was proposed as a semi-active control system. The AIC system consists of a primary structure and an auxiliary structure. The objective of the AIC system is to control the response of the primary structure through engagement and disengagement between the primary and auxiliary structures. Previous switching control algorithms have been shown to be effective in reducing the response of the primary structure. However, they have the main drawback of requiring an excessive engagement-disengagement frequency and high interaction force. In this paper, the regions in which the switching is activated and the regions in which the switching is deactivated are described separately, to effectively determine the engagement or the disengagement. The general relationship between the switching regions and the deactivated switching regions selected according to the engagement-disengagement conditions is described within the newly-developed comprehensive switching framework. The proposed engagement-disengagement conditions are designed within a comprehensive switching framework, to reduce engagement-disengagement frequency and interaction force. Furthermore, the effect of a control sampling period on the AIC system is explained in terms of the engagement-disengagement frequency. The effectiveness of the proposed algorithms and the effect of the control sampling period are considered for a single degree of freedom model under free vibration. It is observed that increasing the duration of stay by using a large control sampling period prevents the AIC system from activating the possible chance of switching. The proposed algorithms are shown to be effective, both in restricting ineffective switching and in reducing interaction force.

Overload Control Algorithms for the Stored Program Control Switching System (축적 프로그램 제어교환기의 과부하 제어 방식에 관한 연구)

  • 김기석;황희영
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.37 no.11
    • /
    • pp.826-833
    • /
    • 1988
  • In this paper we studied the control of overload which could bring the degradation of performance and threaten the stability of the electronic switching system. In order to get the essential requirement for overload control algorithm, we tried to extract the characteristics of commonly used algorithms by means of simulating overload control alogrithms in numerical stored program control switching model. As the result, we could find that the overload control algorithm which monitored the CPU occupancy had the best call complete rate and good response characteristecs and the algorithm using the offered load as a system state variable had a good grade of service which was represented by a short dial tone delay and 3rd quartile of deal tone delay. however, these control algorithms have no generality and need to get the control parameters by the trial-and-error method. We suggested the guidelines on the design of the overload control algorithm.

  • PDF

Obstacle Avoidance of Three-DOE Underactuated Manipulator by Using Switching Computed Torque Method

  • Udawatta, Lanka;Watanabe, Keigo;Izumi, Kiyotaka;Kiguchi, Kazuo
    • Transactions on Control, Automation and Systems Engineering
    • /
    • v.4 no.4
    • /
    • pp.347-355
    • /
    • 2002
  • Obstacle avoidance of underactuated robot manipulators using switching computed torque method (SCTM) is presented. One fundamental feature of this novel method is to use partly stable controllers (PSCs) in order to fulfill the ultimate control objective. Here, we use genetic algorithms (GAs) to acquire the optimum switching sequence of the control actions for a given time frame with the available set of elemental controllers, depending on which links/variables are controlled. The effectiveness of the concept is illustrated by taking a three-degrees-of-freedom (DOF) manipulator and showing enhanced performance of the proposed control methodology.

Torque ripple reduction in DTC of induction motor driven by 3-level inverter with low switching frequency (3레벨 인버터로 구동되는 유도전동기 직접토크제어의 낮은 스위칭 주파수에서의 토크 리플 저감법)

  • 송중호
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.203-206
    • /
    • 2000
  • This paper presents a torque ripple reduction technique of direct torque control(DTC) for high power induction motors driven by 3-level inverters with the inverter switching frequency limited around 0.5-1kHz level. It is noted that conventional DTC algorithms to reduce torque ripple are devised for applications with relatively high switching frequency above 2-3kHz. A new DTC algorithms especially for low switching frequency inverter system illustrates relatively reduced torque ripple are devised for applications with relatively high switching frequency above 2-3kHz. Anew DTC algorithm especially for low switching frequency inverter system illustrates relatively reduced torque ripple characteristics Simulation and experimental results show the effectiveness of the proposed control algorithm

  • PDF

A buffer readout scheduling for ABR traffic control (ABR 트랙픽 제어를 위한 버퍼 readout 스케쥴링)

  • 구창회;이재호
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.34S no.11
    • /
    • pp.25-33
    • /
    • 1997
  • The end-to-end rate-based control mechanism is used for the flow control of the ABR service to allow much more flexibility in ATM switching system. To accommodate the ABR service effciently many algorithms such as EFCI, EPRCA, ERICA, and CAPC2 have been proposed for the switch algorithm. ABR cells and related RM cells are received at the ATM switch fabric transparently without any processing. And then cells received from the traffic source are queued in the ABR buffer of switching system. The ABR buffer usually has some thresholds for easy congestion control signal transmission. Whatever we use, therefore, these can be many ABR traffic control algorithms to implement the ABR transfer capability. The genertion of congestion indicate signal for ABR control algorithms is determined by ABR buffer satus. And ABR buffer status is determined by ABR cells transfer ratio in ATM switch fabrics. In this paper, we presented the functional structures for control of the ABR traffic capability, proposed the readout scheduling, cell slot allocation of output link and the buffer allocation model for effective ABR traffic guranteeing with considering CBR/VBR traffics in ATM switch. Since the proposed readout scheduling scheme can provide more avaliable space to ABR buffer than existing readout scheduling scheme, generation rate of a SEND signal, that is, BCN signal in destination node can be increased for ABR call connection. Therefore, the proposed scheme, in this paper, can be appropriate as algorithm for effective ABR traffic service on output link of ATM switching node.

  • PDF

Digitally Current Controlled DC-DC Switching Converters Using an Adjacent Cycle Sampling Strategy

  • Wei, Tingcun;Wang, Yulin;Li, Feng;Chen, Nan;Wang, Jia
    • Journal of Power Electronics
    • /
    • v.16 no.1
    • /
    • pp.227-237
    • /
    • 2016
  • A novel digital current control strategy for digitally controlled DC-DC switching converters, referred to as Adjacent Cycle Sampling (ACS), is proposed in this paper. For the ACS current control strategy, the available time interval from sampling the current to updating the duty ratio, is approximately one switching cycle. In addition, it is independent of the duty ratio. As a result, the contradiction between the processing speed of the hardware and the transient response speed can be effectively relaxed by using the ACS current control strategy. For digitally controlled buck DC-DC switching converters with trailing-edge modulation, digital current control algorithms with the ACS control strategy are derived for three different control objectives. These objectives are the valley, average, and peak inductor currents. In addition, the sub-harmonic oscillations of the above current control algorithms are analyzed and eliminated by using the digital slope compensation (DSC) method. Experimental results based on a FPGA are given, which verify the theoretical analysis results very well. It can be concluded that the ACS control has a faster transient response speed than the time delay control, and that its requirements for hardware processing speed can be reduced when compared with the deadbeat control. Therefore, it promises to be one of the key technologies for high-frequency DC-DC switching converters.

Optimal control of large scale distributed packet switching system via interaction prediction method (상호작용 예측 방법에 의한 대형 분산 패킷 교환망의 최적제어)

  • 장영민;전기준
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1986.10a
    • /
    • pp.547-549
    • /
    • 1986
  • This paper deals with large scale distributed packet switching system which is modeled by state space form and optimizing routing algorithms and buffer size via a hierachical system optimization method, the interaction prediction method.

  • PDF

Robust and adaptive congestion control in packet-switching networks

  • Shim, Kwang-Hyun;Lim, Jong-Tae
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10a
    • /
    • pp.368-371
    • /
    • 1996
  • In this paper, a feedforward-plus-feedback control scheme is presented to prevent congestion in store-and-forward packet switching networks. The control scheme consists of two algorithms. Specifically, the input traffic adjustment algorithm employs a fairness policy such that the transmission rate of the input traffic is proportional to its offered rate. The control signal computation algorithms to ensure stability of the overall system in the robust sense and to ensure the desired transient behavior in the adaptive, with respect to variations of input traffic, are designed.

  • PDF

Torque ripple reduction in DTC of induction motor driven by 3-level inverter (3레벨 인버터로 구동되는 유도전동기 직접토크제어의 토크리플 저감법)

  • Lee, Kyo-Beum;Song, Joong-Ho;Choy, Ick;Yoo, Ji-Yoon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.5 no.6
    • /
    • pp.620-631
    • /
    • 2000
  • A torque ripple reduction technique of direct torque control(DTC) for high power induction motors driven by 3-level inverters with the inverter switching frequency limited around 0.5-1.0kHz level is presented. It is noted that conventional DTC algorithms to reduce torque ripple are devised for applications with relatively high switching frequency above 2-3kHz. Such conventional algorithms can not accomplish satisfactory torque ripple reduction for 3-level inverter systems with lower switching frequency. A new DTC algorithm, especially for low switching frequency inverter system, illustrates relatively reduced torque ripple characteristics all over the operating speed region. Simulation and experimental results show the effectiveness of the proposed control algorithm.

  • PDF

PMSM Sensorless Operation for High Variable Speed Compressor (고속압축기 구동 PMSM을 위한 센서리스 운전)

  • 석줄기;이동춘;황준현
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.51 no.12
    • /
    • pp.676-681
    • /
    • 2002
  • This paper presents the implementation and experimental investigation of sensorless speed control for a variable-speed PMSM(Permanent Magnet Synchronous Motor) in super-high speed compressor operation. The proposed control scheme consists of two different sensorless algorithms to guarantee the reliable starting operation in low speed region and full torque characteristics using the vector control in high speed region. An automatic switching technique between two control modes is proposed to minimize the speed and torque pulsation during the switching instant of control mode. A testing system of 3.3㎾ PMSM has been built and 90% load test results at 7000r/min are presented to examine the feasibility of proposed sensorless control scheme.