An Improved Carrier-based SVPWM Method By the Redistribution of Carrier-wave Using Leg Voltage Redundancies in Generalized Cascaded Multilevel Inverter

  • Kang, Dae-Wook;Lee, Yo-Han;Suh, Bum-Seok;Park, Chang-Ho;Hyun, Dong-Seok
    • Journal of Power Electronics
    • /
    • 제1권1호
    • /
    • pp.36-47
    • /
    • 2001
  • The carrier-based space vector pulse width modulation(SVPWM), which is considered as highly simple and efficient PWM technology, can be also used in multilevel inverters. The method was originally designed for the two-level inverter and developed to the diode clamped multilevel inverter structure. however it may be noted that it also cause bad switch utilization in cascaded multilevel inverter. This paper introduces an improved carrier-based SVPWM scheme, which is fully suitable for cascaded multilevel inverter topologies because it can achieve the optimized switch utilization through the redistribution of the triangular carrier waves considering leg voltage redundancies while having the advantages of the conventional carrier-based SVPWM. Using simulation and experimental results, the superior performance of new PWM method is shown.

  • PDF

ABR 흐름 제어를 위한 효율적인 명시율 피드백 스위치 알고리즘 (An Efficient Explicit Rate Feedback Switch Algorithm for the ABR Flow Control)

  • 김병철;김동호;조유제
    • 한국통신학회논문지
    • /
    • 제24권9A호
    • /
    • pp.1359-1371
    • /
    • 1999
  • 본 논문에서는 기존의 폭주 회피형 명시율 트래픽 (Explicit Rate feedback) 스위치 알고리즘의 단점을 개선하여 버퍼의 수위와 변화율에 따라 동적으로 목표 이용률을 조장하여 링크 이용 효율을 향상시킨 효율적인 명시율 피드백 스위치 알고리즘을 제안하였다. 그리고, 시뮬레이션을 통하여 기존의 대표적인 명시율 피드백 스위치 알고리즘인 ERICA 스위치와 NIST 스위치의 성능을 분석하고, 제안된 명시율 피드백 스위치 알고리즘과 비교하였다. 시뮬레이션 결과 제안된 ER 피드백 스위치는 동적인 목표 이용률의 조정을 통하여 가용 대역폭의 변화에 빠른 전송률의 변화를 보였으며, 스위치의 최대 큐 길이를 줄여 버퍼 범람을 방지하면서도 매우 높은 링크 이용 효율을 보여 성능이 개선됨을 알 수 있었다.

  • PDF

입출력 단에 버퍼를 가지는 ATM 교환기의 손실우선순위 제어의 성능 분석 (Performance analysis of a loss priority control scheme in an input and output queueing ATM switch)

  • 이재용
    • 한국통신학회논문지
    • /
    • 제22권6호
    • /
    • pp.1148-1159
    • /
    • 1997
  • In the broadband integrated service digital networks (B-ISDN), ATM switches hould be abld to accommodate diverse types of applications ith different traffic characteristics and quality ddo services (QOS). Thus, in order to increase the utilization of switches and satisfy the QOS's of each traffic type, some types of priority control schemes are needed in ATM switches. In this paper, a nonblocking input and output queueing ATm switch with capacity C is considered in which two classes of traffics with different loss probability constraints are admitted. 'Partial push-out' algorithm is suggested as a loss priority control schemes, and the performance of this algorithm is analyzed when this is adopted in input buffers of the switch. The quque length distribution of input buffers and loss probabilities of each traffic are obtained using a matrix-geometric solution method. Numerical analysis and simulation indicate that the utilization of the switch with partial push-out algorithm satisfying the QOS's of each traffic is much higher than that of the switch without control. Also, the required buffer size is reduced while satisfying the same QOS's.

  • PDF

ATM망에서 폭주 제어를 위한 스위치 성능의 비교 분석 (A comparative analysis on switch performances for congestion controls in ATM Networks)

  • 조미령;이상훈
    • 한국컴퓨터산업학회논문지
    • /
    • 제2권4호
    • /
    • pp.547-564
    • /
    • 2001
  • 본 논문에서는 EPRCA(Enhanced Proportional Rate Control Algorithm) 스위치 방식과 EMRCA(Explicit Max_min Rate Control Algorithm) 스위치 방식의 성능을 평가하기 위하여 시뮬레이션을 수행하였다. 시뮬레이션의 평가 기준으로 과도상태와 정상상태에서 각 송신원에서의 전송률(ACR)의 변화, 큐 길이, 링크 대역폭 이용률과 전송률의 공평성 여부를 사용하였다. 실험 결과 EMRCA 스위치 방식은 EPRCA 스위치 방식보다 더 안정적이며 스위치의 버퍼 크기도 줄였으며 더 높은 링크 이용률을 보였다. 이 방식은 스위치에서 MACR(Mean Allowed Cell Rate)의 계산을 위한 부동소수점 연산을 제거하여 EPRCA 스위치 방식이나 기존의 다른 폭주 제어 방식들보다 훨씬 낮은 하드웨어 복잡도를 갖는다.

  • PDF

Converter Utilization Ratio Enhancement in the THD Optimization of Cascaded H-Bridge 7-level Inverters

  • Khamooshi, Reza;Namadmalan, Alireza;Moghani, Javad Shokrollahi
    • Journal of Power Electronics
    • /
    • 제16권1호
    • /
    • pp.173-181
    • /
    • 2016
  • In this paper, a new technique for harmonic optimization in cascaded H-bridge 7-level inverters is proposed. The suggested strategy is based on minimizing an objective function which simultaneously optimizes the converter utilization and Total Harmonic Distortion (THD). The Switch Utilization Ratio (SUR) is formulized for both the phase and line-line voltages of a 7-level inverter and is considered in the final objective functions. Based upon the SUR formula, utilization ratio enhancement will reduce the value of feeding DC links, which improves the efficiency and lifetime of the circuit components due to lower voltage stresses and losses. In order to achieve more effective solution in different modulation indices, it is assumed that the DC sources can be altered. Experimental validation is presented based on a three-phase 7-level inverter prototype.

포워드 컨버터의 스위치 전압 스트레스 감소를 위한 효율적 클램프 (An Efficient Clamp to Reduce Switch Voltage Stress of Forward Converter)

  • 김만고
    • 전력전자학회논문지
    • /
    • 제21권1호
    • /
    • pp.10-18
    • /
    • 2016
  • In this study, an efficient clamp is proposed to reduce the switch voltage stress of a forward converter. The proposed clamp consists of a conventional LC snubber, a tertiary winding, and a diode. When the switch is turned OFF, the magnetizing inductor energy of the transformer is recovered directly into the flyback output, which is the tertiary winding and diode network, instead of circulating in the LC snubber. Therefore, switch voltage stress and circulating current caused by the magnetizing inductor energy are reduced. This condition improves the efficiency of the forward converter with limited switch voltage stress. A theoretical analysis and the design guidelines of the proposed converter are provided. Experimental results are also reported.

A Novel Stiff Membrane Seesaw Type RF Microelectromechanical System DC Contact Switch on Quartz Substrate

  • Khaira, Navjot K.;Singh, Tejinder;Sengar, Jitendra S.
    • Transactions on Electrical and Electronic Materials
    • /
    • 제14권3호
    • /
    • pp.116-120
    • /
    • 2013
  • This paper proposes a novel RF MEMS dc-contact switch with stiff membrane on a quartz substrate. The uniqueness of this work lies in the utilization of a seesaw mechanism to restore the movable part to its rest position. The switching action is done by using separate pull-down and pull-up electrodes, and hence operation of the switch does not rely on the elastic recovery force of the membrane. One of the main problems faced by electrostatically actuated MEMS switches is the high operational voltages, which results from bending of the membrane, due to internal stress gradient. This is resolved by using a stiff and thick membrane. This membrane consists of flexible meanders, for easy movement between the two states. The device operates with an actuation voltage of 6.43 V, an insertion loss of -0.047 dB and isolation of -51.82 dB at 2 GHz.

An Analysis of Effects of TMN Functions on Performance of ATM Switches Using Jackson's Network

  • 허동현;정상욱;이길행
    • 한국정보처리학회:학술대회논문집
    • /
    • 한국정보처리학회 2001년도 추계학술발표논문집 (하)
    • /
    • pp.1533-1536
    • /
    • 2001
  • This paper considers the TMN system for management of public ATM switching network which has the four-level hierarchical structure consisting of one network management system, a few element management system and several agent-ATM switch pairs, respectively. The effects of one TMN command on the local call processing performance of the component ATM switch an analyzed using Jackson's queueing model. The TMN command considered is the permanent virtual call connection, and the performance measures of ATM switch are the utilization, mean queue length and mean waiting time for the processor interfacing the subscriber lines and trunks directly, and the call setup delay of the ATM switch.

  • PDF

3상 SRM 구동용 4-스위치 인버터 PWM 제어 알고리즘 (Control Algorithm for 4-Switch Inverter of 3-Phase SRM)

  • 윤용호;이병국;원충연
    • 전기학회논문지P
    • /
    • 제58권3호
    • /
    • pp.303-309
    • /
    • 2009
  • Switched Reluctance Motor(SRM) has become popular for industrial application, particularly for low medium drives due to the advantages of SRM over the other ac motors: SRM can be manufactured with low cost because it has a simple structure. But, asymmetric bridge converter that generally is used for driving requires two discrete switching devices and freewheeling diodes per phase, and cause the SRM drives to be complicated and to increase the cost of overall system. Therefore, this paper suggests a new type of 4-switch converter for SRM. 4-switch converter topology is studied to provide a possibility for the realization of low cost 3-phase SRM drive system. For effective utilization of the developed system, a new current control algorithm is designed and implemented to produce the desired dynamic performance. With the developed power conversion circuit and control scheme, it is expected that the proposed system can be widely used in commercial applications with reduced system cost.

IEC60947-4에 따른 전자개폐기 전기적 수명시험설비의 과도현상을 고려한 SCR최적 정격선정에 대한 연구 (The transient analysis for choosing the optimal SCR ratings of AC3 utilization category testing equipment used for electrical durability test for magnetic switch)

  • 류행수;김갑동;한규환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 A
    • /
    • pp.354-356
    • /
    • 2004
  • This paper is the transient analysis for choosing the optimal SCR ratings of AC3 utilization category testing equipment(AC3 TE) used for electrical durability test for magnetic switch according to IEC60947-4 Annex B by utilizing EMTP -ATPDraw. Magnetic contactor closes and opens the motor load with ON/OFF switch of electronic contactor. It is also used for protecting and controlling the load. Magnetic contactor detects the over-current flow in the load with a over-current relay and disconnects the load by opening its control power. The key cost of AC3 TE is the SCR ratings. The more decreases SCR ratings, the more decreased the cost is, but it is impossible to ensure the reliability. On the other hand, the more increases SCR ratings, the more increased the cost is. Thereupon, in this paper after the testing circuit is simulated by using EMTP-ATPDraw the SCR ratings will be applied in order to guarantee the testing reliability of PT&T(Power Testing and Technology institute in LG Industrial Systems Co.,Ltd.).

  • PDF