• Title/Summary/Keyword: Switch mode

Search Result 534, Processing Time 0.027 seconds

Cost-Effective APF/UPS System with Seamless Mode Transfer

  • Lee, Woo-Cheol
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.1
    • /
    • pp.195-204
    • /
    • 2015
  • In this paper, the development of a cost-effective active power filter/uninterruptible power supply (APF/UPS) system with seamless mode transfer is described. The proposed scheme employs a pulse-width-modulation (PWM) voltage-source inverter and has two operational modes. First, when the source voltage is normal, the system operates as an APF, which compensates for the harmonics and power factor while boosting the DC-link voltage to be ready for the disturbance, without an additional DC charging circuit. A simple algorithm to detect the load current harmonics is also proposed. Second, when the source voltage is out of the normal range (owing to sag, swell, or outage), it operates a UPS, which controls the output voltage constantly by discharging the DC-link capacitor. Furthermore, a seamless transfer method for the single-phase inverter between the APF mode and the UPS mode is also proposed, in which an IGBT switch with diodes is used as a static bypass switch. Dissimilar to a conventional SCR switch, the IGBT switch can implement a seamless mode transfer. During the UPS operation, when the source voltage returns to the normal range, the system operates as an APF. The proposed system has good transient and steady-state response characteristics. The APF, charging circuit, and UPS systems are implemented in one inverter system. Finally, the validity of the proposed scheme is investigated with simulated and experimental results for a prototype APF/UPS system rated at 3 kVA.

Analysis and Implementation of a New Single Switch, High Voltage Gain DC-DC Converter with a Wide CCM Operation Range and Reduced Components Voltage Stress

  • Honarjoo, Babak;Madani, Seyed M.;Niroomand, Mehdi;Adib, Ehsan
    • Journal of Power Electronics
    • /
    • v.18 no.1
    • /
    • pp.11-22
    • /
    • 2018
  • This paper presents a single switch, high step-up, non-isolated dc-dc converter suitable for renewable energy applications. The proposed converter is composed of a coupled inductor, a passive clamp circuit, a switched capacitor and voltage lift circuits. The passive clamp recovers the leakage inductance energy of the coupled inductor and limits the voltage spike on the switch. The configuration of the passive clamp and switched capacitor circuit increases the voltage gain. A wide continuous conduction mode (CCM) operation range, a low turn ratio for the coupled inductor, low voltage stress on the switch, switch turn on under almost zero current switching (ZCS), low voltage stress on the diodes, leakage inductance energy recovery, high efficiency and a high voltage gain without a large duty cycle are the benefits of this converter. The steady state operation of the converter in the continuous conduction mode (CCM) and discontinuous conduction mode (DCM) is discussed and analyzed. A 200W prototype converter with a 28V input and a 380V output voltage is implemented and tested to verify the theoretical analysis.

The Analog-circuited Low-loss Bypass Current Sensing Method for Average Current Mode Control (아날로그 회로로 구현가능한 평균전류제어 저손실 bypass 전류센싱방법)

  • Kim, Seok-Hee;Choi, Byung-Min;Park, Joung-Hu;Jeon, Hee-Jong
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.19 no.2
    • /
    • pp.133-138
    • /
    • 2014
  • This paper proposes a low power-loss averaging current mode control using a resistor and bypass switch. Generally, current sensing method using a resistor has a disadvantage of power loss which degrades the efficiency of the entire systems. On the other hand, proposed measurement technique operating with bypass-switch connected in parallel with sensing resistor can reduce power loss significantly the current sensor. An analog-circuited bypass driver is implemented and used along with an average-circuit mode controller. The bypass switch bypasses the sensing current with a small amount of power loss. In this paper, a 50[W] prototype average current mode boost converter has been implemented for the experimental verification.

Full Wave Mode ZVT-PWM DC-DC Converters (전파형 ZVT-PWM DC-DC 컨버터)

  • 김태우;안희욱;김학성
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.6 no.3
    • /
    • pp.243-249
    • /
    • 2001
  • This paper proposes a full wave mode ZVT-PWM boost converter. The converter with the auxiliary switch in a full wave mode makes possible soft switching operation of all switches including the auxiliary switch whereas the auxiliary switch is turned off with hard switching in the conventional converter. Therefore, the proposed converter reduces the turn-off switching loss and switching noise of the auxiliary switch without additional passive and/or active elements and high power density system can be realized.

  • PDF

BPM Design Optimization of Mach-Zehnder Type Tandem Optical Switch and Its Operational Characteristics (2단 종속 접속 마하젠더형 광스위치의 BPM 최적설계 및 동작특성)

  • Choi, Young-Kyu;Kim, Gi-Rae
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.10
    • /
    • pp.1829-1834
    • /
    • 2008
  • An optical switch/modulator is designed and the light propagating characteristics is analyzed by the simplified BPM. The distinctive feature of the switch/modulator is that all the waveguide branches are designed to be single-mode. Principle of the device is based on the coupled mode theory in the Y-junction interconnecting waveguide. In spite of all the waveguides are designed to be single-mode, adjusting the interconnecting waveguide length of the device, the same characteristics as existing device up to date is obtainable. Numerical results show that the switching characteristics periodically depends on the interconnecting waveguide length with a spatial of about 150${\mu}m$ in the Ti:LiNbO3 step index waveguide. The concept of design would be utilized effectively in fabricating the monolithic high density of optical integrated circuit.

Primary Side Current Control Method in Dc-to-Dc Converters for LED Lighting (LED조명을 위한 직류-직류 변환기의 일차 측 전류 제어 기법)

  • Kwon, O.H.;Hong, J.P.;Qu, Wanyuan;Son, Y.S.;Choi, Y.H.;Choi, B.C.
    • Proceedings of the KIPE Conference
    • /
    • 2011.07a
    • /
    • pp.346-347
    • /
    • 2011
  • 본 논문에서는 정전류 LED조명 구동을 위한 일차측 전류 제어의 새로운 기법을 제안한다. 일정한 온-타임으로 동작하는 경계 모드(Critical Mode) 플라이백 타입으로 우수한 역률을 달성하였고, 의사 공진(Quasi-resonant) 동작으로 스위칭 손실을 최소화 하였다. 본문에서 LED전류가 5% 이하로 정전류 제어되는 9W급 플라이백 타입의 일차 측 전류 제어 기법을 실험으로 검증한다.

  • PDF

A 0.13-μm CMOS RF Tx/Rx Switch for Wideband Applications

  • Kim, Jeong-Yeon;Kim, Chang-Wan
    • Journal of electromagnetic engineering and science
    • /
    • v.8 no.3
    • /
    • pp.96-99
    • /
    • 2008
  • This paper describes a $0.13-{\mu}m$ CMOS RF switch for $3{\sim}5$ GHz UWB band(mode 1). It can improve isolation characteristics between ports by using deep n-well RF devices while their source and body terminals are separated. From the measurement results, the proposed T/R switch is comparative to the on-wafer probing measurement results of the series-shunt T/R switches. When the proposed T/R switch operates as Tx mode, measured insertion loss from Tx to output port is less than 1.5 dB and isolation between Tx and Rx is more than 27 dB for $3{\sim}5$ GHz. Return loss for the Tx port is more than -10 dB and input P1dB is +10 dBm.

Design of Multilayer LPF and RF diode switch for GSM (GSM용 적층형 저역통과필터와 RF 다이오드 스위치의 설계)

  • Choi, U-Sung;Yang, Sung-Hyun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.16 no.3
    • /
    • pp.416-423
    • /
    • 2012
  • Using Ansoft HFSS(High Frequency Structure Simulator) and Serenade(circuit simulator), multilayer LPF and RF diode switch for GSM were designed. Diodes were transformed the inductor and capacitor in Tx and Rx for the simulation of equivalent circuit, respectively. In particular, the design of the simulation for multilayer RF diode switch was carried out with considering the variance of device and contraction percentage.

High Power Cavity Type Tunable Filter Using Switch for 1.5 GHz Band (Switch를 이용한 1.5 GHz 대역 고출력 Cavity 기반 Tunable Filter)

  • Ahn, Sehoon;Lee, Minho;Park, Jongcheol;Jeong, Gyetaek
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.27 no.1
    • /
    • pp.1-7
    • /
    • 2016
  • In this paper, the tunable filter based on high power cavity using mechanical switch for 1.5 GHz band is presented. The LPF is inserted to eliminate the spurious wave, coupler is embeded to extract the output power, and then the tunable filter system is configured using mechanical switch. The LPF obtains attenuation over 40 dB between 4 GHz and 12.75 GHz, Coupler is satisfied with coupling value 40 dB and coupling isolation over 55 dB. The tunable filter system using mechanical switch obtains insertion loss 0.88 dB at bypass mode between 1,495.9 MHz and 1,510. 9 MHz, 3.29 dB at fil mode between 1,495.9 MHz and 1,500.9 MHz. It is also satisfied with output power of 132 W at the center frequency 1,498.4 MHz, and switching time below 10 ms.

Ultra-Power-Saving 2 Ports PLC Wall Switch Development (초절전형 PLC 2구 스위치 개발)

  • Han, Jae-Yong;Lee, Sun-Heum
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.44 no.11
    • /
    • pp.51-55
    • /
    • 2007
  • Generally, PLC (Power Line Communication) based home automation devices such as wall switch, walt socket, gas controller, etc, must maintain wake-up status at all time to control other electronic devices and monitor their on/off status whether they are in service or not. In order to reduce the unnecessary energy consumption during the standby mode, the new power-saving PLC 2 ports wall switch has been developed, separating PLC communication part and controller part and introducing sleep mode. In addition, to expand life cycle of PLC product and to reduce the rate of product failure in active mode, the instant controlling method in controlling process is adopted instead of the maintenance controlling method. In comparison to the earlier model, the new 2 ports PLC wall switch has reduced power by 0.95[W] less in standby mode and 3.2[W] less in active mode than the previous one.